Hello
I've got a question about CGI and OWS (or OAS, it's the same problem)
I've got a C compiled program which intercept signals (especially SIGUSR1) and execute a task (for exemple a simple "printf" and exit
The program do an infinite loop
program. When i execute this program in a shell window, the program loop infinitely which is logical. In a second shell window i send signal SIGUSR1 (with a "kill -USR1") to the process of the program. Immediatly, the program execute the task and exit. The program works perfectly.
Now, i put the program in a cgi directory configured in a Web listener
I execute the program in a navigator (Netscape) with an url likes http://my_server/my_cgi_directory/my_program
The program loops
I creates a cgi program (a shell) which gets the id process of the program which loops and send the USR1 signal. I put this cgi program in my cgi directory.
In a second navigator, i launch the cgi program which normally send USR1 signal, and the program which loops should execute the correctly task and exit as it does.
And now, the program don't exit, in fact it doesn't launch the task.
I've got the same problem with OWS 3.02, OAS 4.08, linux, aix platform.
I've tried to send the USR1 signal in a window shell but no action, the signals are blocked.
The only two signals KILL and STOP works properly, in a window shell AND in an URL with navigator.
Have you got this problem too ?? Which is the solution ??? I'have open a call to ORACLE SUPPORT but no response, they say the problem perhaps will never be solved (for them, it may not be a BUG)
Thanks in advance
null

Regarding to issue #1,
I would suggest to the change your virtual path to physical path mapping setting in OAS. The OJSP engine will lookup pages relative to your physical path (not the default doc root).
Regarding to issue #2,
Unfortunately, the information you provided is rather limited. It's difficult to do some definite diagnositic based the brief description. Sorry.
null

Similar Messages

  • I am using an apple TV to show a slide show which is sent via WiFi from a mini computer.  The slide show repeats for a few hours and then stops and shows "no signal".  What's going on- and how do I get the show to cycle indefinitely?

    I am using an apple TV to show a slide show which is sent via WiFi from a mini computer.  The slide show repeats for a few hours and then stops and shows "no signal".  What's going on… and how do I get the show to cycle indefinitely?  (I have set the server to NEVER sleep)

    Welcome to the Apple Community.
    Have you also set the Apple TV not to sleep.

  • OAS and Linux and Apache

    I have successfully installed OAS 4.0.8.1 on Linux RedHat 6.1. The default (oracle) http listner runs fine, after setting it to port 81. I did this because the default http server for Linux (Apache 1.3.9-4) is on 80. I would like to use Apache as my http listner, and have found some documentation on how to do this at http://www.olab.com/doc/books/admin/thirdp.htm, but am a little confused with the instructions. It states that Apache must be compiled with mod_so support. I have verified that this is so with the "httpd -l" command. Before that, it mentions that...
    "libapadp.so must be linked into the Apache HTTP Server." Can anyone tell me how this is done, and with which version of Apache should be used? 1.3.6 seems to be a popular one and is mentioned in the Oracle Application Server Installation Guide for Release 4.0.8.1 in Certified Software.
    I have tried to move libapadp.so and ndwfapd.so into the /modules subdirectory my Apache install (once again 1.3.9-4) and adding "LoadModule ows_module ndwfapd.so" in my httpd.conf file, but when the server tries to start, I get the error message...
    "Cannot load /etc/httpd/modules/ndwfapd.so into server:libapadp.so: cannot open shared object file:No such file or directory"
    Has anyone run into this problem? I imagine many people have done this. As I am new to Linux and OAS and Apache, maybe I'm missing something fundamental that I haven't learned yet, but hey, isn't this what learning is all about?
    If anyone can help me with this hurdle, I would greatly appreciate it.
    Thanks in advance,
    Kirby

    Hi Guys,
    I am pulling my hair out with this one too.
    I tried to link the library "libapadp.so" to
    apache using the Makefile in the source directory by adding the path and libapadp.so to the EXTRALIBS variable. It works in the
    sense that it tried to link the lib but fails because there are a bunch of unresolved dependencies. As somebody else stated, Oracles documentation sucks. I ask for support and got sent here, I guess that they don't know how to make it work either.
    Will let you know if I have any success.
    Brett.
    [email protected]
    <BLOCKQUOTE><font size="1" face="Verdana, Arial">quote:</font><HR>Originally posted by Jason Gerry ([email protected]):
    I've been working on this problem as well. I haven't got it to work YET, but I'm trying.
    Your error message is relating to Apache not being able to find the shared module. You can fix this by telling it explicitly where to find it since it doesn't seem to be in the PATH.
    LoadModule ows_module /opt/app/oracle/product/8.0.5/ows/4.0/lib/ndwfapd.so
    Your directory structure may be different. In any case, this SHOULD work, my Apache listeners start up, but they don't actually respond to requests and they freeze the machine. Oh well.
    Still working on it!
    jason
    <HR></BLOCKQUOTE>
    null

  • I have a problem with a vi that crash and stops the signal generation​.

    I want to control several pumps and valve at the same time. Three of them are comanded by a board installed in other computer, so that I have to comunicate with them by a TCP/IP comunication. The others one are controled by signals sent by a PCI-6024 E board which is installed in my computer. The problem is that I want to create a vi that controls every equipment at the same time. I did a Vi that is in attach, but the problem is that when I run the vi it works during a certain time, but after 10 minutes (more or less) it stops to send the signals to the pumps. Could someone help me?
    Attachments:
    controlo_bombas_caudais.vi ‏98 KB
    valvula.vi ‏53 KB

    You did not include your subVIs so not much can be inferred. Several points of poor programming jump out
    1. Use time delays in your loops to keep them from racing
    2. Put the Open Application Ref and Open VI Ref before the start of the loop and the Close Ref after the loop

  • Noise from DAQ signals sent through a 2532 switch

    Hello,
    I may have a hopeless case here, but it's worth a shot....
    I am trying to send DAQ analog voltage time traces through a 2532b switch, and then to my DUT. When I measure the DUT without the switch, my noise level is very low. When I route signals through the switch to the DUT, the noise is increased (as expected) but to a degree that makes this system totally useless for my application. Is the 2532 not designed to route analog signals? Can I hope to send analog signals through my switch with say a doubling in noise instead of a 15x increase in noise?
    I have posted a schematic of how my system is configured. Note that wherever possible, I am using BNCs. I even threaded the 2532 ribbon cables through a 1/2 in. tinned copper braid, so the system is about as well shielded as is possible with this hardware. I've also posted signal sent to the DUT (in this case a dummy 1Mohm resistor) using a 1Mhz sampling rate.
    Thanks, everyone!
    Attachments:
    setup.png ‏23 KB
    no switch.PNG ‏72 KB
    with switch (2).PNG ‏75 KB

    Hi Frank,
    Sorry I should have included more information. The DAQ is outputting a voltage signal, for example a 1Hz 1V sin wave. This signal serves as the external voltage source for a potentiostat, such that the potentiostat sources the signal it receives from the DAQ. The potentistat has hi and low leads (working electrode and counter electrode) which are routed through the switch before going to the DUT. The potentiostat then measures the actual applied voltage and the measured current and outputs them as voltage signals which are fed directly into the DAQ.
    The breakout boxes are all shielded and so are the cables. The DUT is in a faraday cage.
    As far as noise sources, the building ground is not terrific but it is pretty good. 60hz noise is present, but the fft spectrum of the noisy signal also contains prominent signals at 80kHz and higher. The potentiostat is designed for high bandwidth, low current applicaitons and so has very favorable noise. The PXIe is the only computer on in the room, and all electronics are plugged into a isolated power supply (it think it is generically called a UPS). I've turned off all other equipment in the room including the lights.
    Anyways, the noise only shows up when I route the signal from the potentiostat through the switch. When I send the signal from the potentiostat directly to the DUT, the noise is great (see attachments in previous posts). I would blame the extra noise on a ground loop except that as I have set it up, routing the signal through the switch does not introduce any extra paths to ground.
    Thanks for taking a look at this!
    -Gim

  • HT4597 Can I have 2 accounts on my iPhone.  I have 2 on my computer and have a signal that 1 email is in my inbox.  It is an iCloud message but I can't access it.  Hope someone can help.  Thanks,  Lorna

    Can I have 2 accounts on my iPhone.  I have 2 on my computer and have a signal that 1 email is in my inbox.  It is an iCloud message but I can't access it.  Hope someone can help.  Thanks,  Lorna

    You can only have one active iCloud account and one iTunes account.  Are you by chance refering to email accounts defined in the mail app?  If so, if one of the accounts (a non-iCloud account) is a POP account, then an email is usually sent to one device.  Once sent, the email is deleted from the server, thus other devices never get copies.  That's how POP works.

  • IPhone 5S lost voicemail and when I tap vm icon the phone diales voicemail and gets busy signal.  No other options show.

    iPhone 5S lost voice mail and when I tap vm icon the phone dials voice mail and gets busy signal.  No other options show.
    started yesterday.  No voice mail at all.  When I tap the voice mail icon the phone immediately dials some number and that number rings busy.  I can't select anything else.   Using Virgin mobile/  I am stumped.
    I have already tried a soft boot... power and home button....
    Help!

    Other than changing the SIM card, you don't mention any troubleshooting you did with your phone.
    If you haven't already, try the following steps as needed:
    Settings > General > Reset > Reset Network Setting.
    Reset phone - press both home and sleep/wake buttons until the Apple logo appears.
    Restore phone in iTunes using a backup
    Restore in iTunes as a new iPhone
    IF the last step doesn't fix it, there is a hardware problem and you should make an appt. with an Apple Store Genius Bar. The fact that you haven't dropped the phone by no means rules out hardware issues.

  • Problem with replies in Maverick's mail.  Originating emails send fine.  When replying to an email (various addresses) the reply is hung up and can not be sent.  Option becomes put in draft, delete, etc.  Any suggestions would be helpful

    Problem with replies in Maverick's mail.  Originating emails send fine.  When replying to an email (various addresses) the reply is hung up and can not be sent.  Option becomes put in draft, delete, etc.  Any suggestions would be helpful.  Mid 2013 iMac.

    I don't know how rare this is.  I went a week or so without a problem, and now it's starting to recur.  Also, in some instances, an email will look unsent (remain in the outbox on the Treo), but it has been sent, and recipients are replying while I'm trying to figure out what is going on.  Further, it will send the same email over and over during this madness.
    This is a show stopper.  If there isn't a software fix soon, I may chuck this phone in the garbage.
    Post relates to: Treo 800w (Sprint)
    UPDATE:  The problem comes and goes.  The next day, no changes to the treo, everything workeds.  Now i'm suspecting the sprint server, and how it/the phone responds from failing to send while roaming.  I've since turned off roaming, and haven't had a problem for several days.
    Message Edited by slrichardson on 12-22-2008 01:12 PM

  • HT4623 i have issue with my iphone5, the phone is open and good network signal, but when some one calling me they cant reach me, like the phone is off

    i have issue with my iphone5, the phone is open and good network signal, but when some one calling me they cant reach me, like the phone is off

    You are as far as you can be with the original iPad; only iPad 2 and greater will update to 7+

  • How to read and display a signal from my a miccrontroller (MCB1700) onto labview connected via a CAN port on a PXI machine

    How do you read and display a signal from my a miccrontroller (MCB1700) onto labview connected via a CAN port on a PXI machine?
    I tried using a DAQ Assistant but the CAN port is not included as one of the supported physical channels even though all its drivers are upto date.
    Please help..
    Thanks.
    Solved!
    Go to Solution.

    Attached herewith is a print screen of what is showing on MAX
    The CAN ports are on NI PXI-8461
    Hopefully that clarrifies something.
    Attachments:
    Untitled.png ‏212 KB
    Untitled.png ‏212 KB

  • How to read and display a signal from my PIC Microcontr​oller onto Labview?

    Hi,
    I am doing a project on a Pulse Oximeter and i am trying to read and display the signal from my PIC Microcontroller on Labview? How do i go about doing it? I am using the PIC16F877 and also making use of the USART?
    How do i implement and initialise the USART in PIC16? What are the steps to be taken, please guide me through the process? The link provides information regarding the USART connection, initialisting and stuff? Is it correct to use these codes in my program?Link: http://ww1.microchip.com/downloads/en/AppNotes/007​74a.pdf
    Also, i am using the RS232 serial interface to connect to the PC? The connector i am using is the DB9 Connector. Which template and VI can i use? Am i supposed to use the NI-DAQmx and VISA? Also, for my USART connection, i am using the MAX232 Driver which is applicable for my application as i am working with +5V. So far, i have been reading and trying out on Labview and the steps i have taken are:
    1) Open a New VI and used the Instrument I/O(Read & Display) template?
    2) How do i configure the Instrument I/O Assistant Express VI to read the info from my device connected to COM1?
    3) I was reading the Labview Manual, 'Getting Started with Labview' and i was following the steps under Page 55, Communicating with an Instrument. Am i on the right track?
    4) How do i check and make sure that the port settings of the I/O Assistant and my PIC Micro Match
    Please help me out and guide me through the process. I am student at a polytechnic and i am very new to Labview and the software is used as a development tool for the project. I have a deadline to meet and i hope i can get a response as fast as possible. Your help will be kindly and greatly appreciated. I hope to hear from you guys soon.You can e-mail me all your answers at [email protected]
    Thank You
    Best regards,
    Ashwin
    Ashwin Kumar Mansukhani
    Attachments:
    Getting Started with Labview.pdf ‏901 KB

    Hi Ashwin,
    It is a good idea to first be able to communicate with the microcontroller using some sort of serial communication software such as "HyperTerminal" or "Procomm", etc. Refer to MicroChip's recommendations on this.
    Once that works, then you are ready to use LabView.
    Here is a link which covers many aspects of serial communication. Link - click here
    You probably received a development kit. They usually have a readily available interface. It's been a long time since I played with the PIC, but I seem to remember that you need to program the serial communication driver (as well as at least a bootloader) to get the serial communication going. The driver contains the necessary protocols so that you PC can have a machine conversation with the target (PIC).
    It sounds like a fun & interesting project. Please avoid to have replies to your personal email. By having the answers posted to this thread, you will get much more support and advice.
    Have fun,
    JLV

  • How to read and display a signal from my PIC Microcontroller onto Labview

    Hi,
    I am doing a project on a Pulse Oximeter and i am trying to read and display the signal from my PIC Microcontroller on Labview? How do i go about doing it? I am using the PIC16F877 and also making use of the USART?
    How do i implement and initialise the USART in PIC16? What are the steps to be taken, please guide me through the process? The link provides information regarding the USART connection, initialisting and stuff? Is it correct to use these codes in my program?Link: http://ww1.microchip.com/downloads/en/AppNotes/00774a.pdf
    Also, i am using the RS232 serial interface to connect to the PC? The connector i am using is the DB9 Connector. Which template and VI can i use? Am i supposed to use the NI-DAQmx and VISA? Also, for my USART connection, i am using the MAX232 Driver which is applicable for my application as i am working with +5V. So far, i have been reading and trying out on Labview and the steps i have taken are:
    1) Open a New VI and used the Instrument I/O(Read & Display) template?
    2) How do i configure the Instrument I/O Assistant Express VI to read the info from my device connected to COM1?
    3) I was reading the Labview Manual, 'Getting Started with Labview' and i was following the steps under Page 55, Communicating with an Instrument. Am i on the right track?
    4) How do i check and make sure that the port settings of the I/O Assistant and my PIC Micro Match
    Please help me out and guide me through the process. I am student at a polytechnic and i am very new to Labview and the software is used as a development tool for the project. I have a deadline to meet and i hope i can get a response as fast as possible. Your help will be kindly and greatly appreciated. I hope to hear from you guys soon.You can e-mail me all your answers at [email protected]
    Thank You
    Best regards,
    Ashwin
    Ashwin Kumar Mansukhani
    Attachments:
    Getting Started with Labview.pdf ‏901 KB

    Hi Ashwin,
    I am not familiar with the PIC Microcontrollers, but I am assuming you mean that you have the microcontroller sending out serial data that you want to read on another computer with LabVIEW. Please let me know if this is incorrect.
    What type of data is coming out of the serial port? Is it ASCII, or binary? The reason I ask this is that the serial communication in LabVIEW is done through a protocol called VISA, which uses ASCII data to send and receive. You can later convert this data into whatever form you need, but this is what it is designed to read and write.
    You can check the settings such as baud rate and data bits in a configuration utility called Measurement and Automation Explorer, or MAX. When you open up the MAX interface, you can expand the Devices and Interfaces entry on the left, and then expand the Ports entry to see your serial port. When you highlight this port, select the Port Settings tab at the bottom of the window, and you can see what the current settings are, and change them if you need to. You can also set these parameters in LabVIEW using the VISA Configure Serial Port VI.
    You can also test communication in MAX by right clicking on the correct port and choosing Open VISA Session. Then choose the Basic I/O light blue tab, and then go to the Read tab. When you click execute, it should read in what is coming from the serial port. This will allow you to verify that the correct information is coming in before even trying to acquire the data in the LabVIEW environment.
    In LabVIEW, the best resource to use the Basic Serial Write and Read example program that ships with LabVIEW. By examining the block diagram of this program, you will be able to see the basic programming flow of serial communication in LabVIEW.
    I hope this information was helpful! Please let us know if there's anything else we can help with.
    john
    Applications Engineer

  • HT201303 how do i associate a different apple ID with my ipad?  I need to do this bc my gmail account was hacked and a hoax email sent out from it. so i opened a new gmail account and want to associate this new email with my ipad

    how do i associate a different apple ID with my ipad?  I need to do this bc my gmail account was hacked and a hoax email sent out from it. so i opened a new gmail account and want to associate this new email with my ipad

    To check if you have a virus, you can download ClamXav
    also, go to Applications>Utilities>Activity Monitor and see if there's anything that you don't recognize, and check your sent email to see if you've been sending emails without your knowledge.

  • Is there an APP to monitor call usage and number of texts sent

    Is there an APP to monitor call usage (in minutes) and number of texts sent etc so I can ensure I am keeping within my contract? I am getting my 3GS on Thursday so do not know if the phone has this facility already inbuilt or whether there is an app I can buy to do this for me?
    Thank you for any help and info to answer my question.

    Unless O2 has an app available via the iTunes app store that provides for this as AT&T does for the iPhone sold in the U.S., I don't believe so.
    The iPhone includes a usage indicator for Call Time and Cellular Network Data usage, which can be reset on a monthly basis based on your billing cycle, but there is no usage indicator for the number of messages sent or received.

  • How can I set up an SMS group so that all group members can dial a group number and have a text sent out to all members of the group

    How can I set up an SMS group so that all group members can dial a group number and have a text sent out to all members of the group
    This would be an SMS group similar to an email listserv but running on the SMS network
    I have seen private individuals offering this service
    It seems strange to me that no internet site like Apple, Yahoo or Google offers this as a free service much as the email group services are free services.
    Steve

    I think the app GroupMe might do what you want. You might also try contacting your carrier. My carrier offered some fancy group texting service for a while but they never really advertised it so, unless you asked, you never would have known. But, GroupMe is available in the app store. There are lots of other apps that also do group texting but it seems to be the one that gets recommended the most.

Maybe you are looking for