Project Server 2010 - PDP updates not triggering Project Server Events

Hello,
We're experiencing an issue whereby when a user updates a Project PDP, no update is triggered and reflected in the reporting database.
My question is, which Server Side Event Handler is responsible for picking up PDP changes (i.e. Changes to Enterprise Custom Fields)?
Can someone please assist?
Thanks in advance.
What we have configured and is working as expected...
Event: Reporting
Event Name: ProjectChanged, ProjectCreated, ProjectDeleted

There may be multiple reasons for this.
1. SharePoint timer Job is malfunctioning:
For this try restarting SharePoint timer Job. through SP Powershell:
Stop SPTimerv4 , Start SPTimerv4
 2: SharePoint Cache is full:
Reset SharePoint Cache by deleting all XML files ( except cache.ini
)  in SharePoint Cache located in System Drive\ProgramData\Microsoft\SharePoint\Config\<GUID>
3: Check if Microsoft Project Server Event Service is running in Services.msc, try restarting it.

Similar Messages

  • Unable to launch project schedule in project pro 2010 via the icon in project center on project server 2010

    Unable to launch a project in project pro 2010 via the icon in project server 2010 project center.  Nothing happens.  The pull down "open" menu doesn't do anything either.  Can't open the schedule in project pro in read-only or edit mode.
    This is happens to a handful of project managers.  Can't find a common thread.
    Janice Weaver

    Hi Brian - the latest 'weight on my shoulders' was vacation :) - so just catching up - first day back.  We do have a fix coming in August CU for a problem that sounds very similar - but we would need to see your data to confirm if this is the case
    or not.  So the choices at the moment are to wait until we release the week after next, or open a support incident - but we would likely need assistance from your DBA to either run some queries or get us a copy of the DBs.
    Best regards,
    Brian.
    Blog |
    Facebook | Twitter | Posting is provided "AS IS" with no warranties, and confers no rights.
    Project Server TechCenter |
    Project Developer Center |
    Project Server Help | Project Product Page

  • 1 new update have been added to the project would you like to close the project and apply these updates message in project 2010

    1 new update have been added to the project would you like to close the project and apply these updates message  in project 2010.
    One of the PM is getting above message and not any recent changes happened?

    Hi,
    This message appears when an update has been sent for his approval and is pending. It could happen while opening the project plan, or when clicking on something like "retreive tasks updates" from the backstage menu of MS Project Pro.
    The PM should go to his approval center and check for any approval pending.
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, P-Seller |

  • BizTalk Server 2010 Cumulative Update 6 - Compatibility with BTAHL7?

    We recently installed BizTalk Server 2010 CU 6 in a development environment for testing. After the installation, the error below was generated when an HL7 message was submitted through an MLLP adapter to a request response receive location
    with the BTAHL7ReceivePipeline receive pipeline and BTAHL7SendPipeline send pipeline. These pipelines are supplied in the BTAHL7 and have not been customized. We applied the udpate in an environment with our current state BizTalk Server
    2010 CU5 and Biztalk Adapter Pack 2010 CU2 and in one with BizTalk Server 2010 CU5, Biztalk Adapter Pack 2010 CU3 and BTAHL7 Accelerator hot fixes 2564013, 2607536,2702143,2713884,2732905,2758524. In both cases, the same error was encountered. Has anyone else
    experienced this issue?
    "A pipeline component in the receive pipeline:"<pipeline info - version, culture and public key token>" is using the message context properties "BTS.MessageDestination" or "BTS.SuspendMessageOnRoutingFailure" in a
    unsupported fashion. The pipeline processing is being terminated."

    Hi rpara,
    We can use BizTalk Server 2010 Cumulative Update 6 with HL7.
    This cumulative update package for Microsoft BizTalk Server 2010 contains hotfixes for the BizTalk Server 2010 issues that were resolved after the release of BizTalk Server 2010.
    For this issue, it's recommended to uninstall Update 6 first, and reinstall it again, and check whether it has same issue.
    Cumulative update package 6 for BizTalk Server 2010
    Service Pack and Cumulative Update list for BizTalk Server 
    Please let me know if there is anything that I can do to help.
    Best regards,
    Angie
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • Connection Error - Server BUSOBJ-JF00:6400 not found or server may be down

    Good afternoon.
    We have a Business Objects 3.1 installation on Windows 2003 that was running fine up until recently.  While trying to log on to any BOBJ function the error Server BUSOBJ-JF00:6400 not found or server may be down (FWM 01003) null is seen.
    I am unable to logon to the CMC or any Admin function with the Administrator user either.
    The SIA is up and running yet no service is listening on port 6400 when I do a netstat.
    In services it says that the BOEMySQL is running.
    It is a 3.1 upgrade using MySQL DB.  Any hints as to what to look for?
    I do have an OSS open for this right now, but no response yet.

    Hello,
    try the following:
    1. Connect remote to the Server using RDC and try to log into InfoView there
    2. Can you connect with any Client?! Like Designer or something
    3. Ttry to LogIn to InfoView using IP_ADRESS:6400
    4. Can you ping the Server ?
    5. When you say you did an upgrade did you used the "Update Objects" function in the CCM after migrating the Repository ?
    Regards
    -Seb.

  • How to install and configure Exchange Server 2010 DR (disaster recovery) on Windows server 2012.

    We need to install and configure Exchange Server 2010 with DR(disaster recovery on Server 2012.
    Pls suggest step by step.
    Pankaj Kumar

    Hi,
    Here is an article which may help you for your reference.
    Deploying High Availability and Site Resilience
    https://technet.microsoft.com/en-us/library/dd638129(v=exchg.141).aspx
    Besides, there is a related thread here.
    https://social.technet.microsoft.com/Forums/exchange/en-US/577c9433-a20b-442e-8ce7-be59aea35855/preparation-for-deploying-exchange-2010-servers-at-remote-site-dr-site?forum=exchangesvrdeploylegacy
    Hope this is helpful to you.
    Best regards,
    Belinda Ma
    TechNet Community Support

  • Setting Up Earned Value Reporting in Project Server 2010, Using Hours Not Dollars

    Hello All,
    Are there instructions for setting up Project Server 2010 for Earned Value data capture and reporting?  I'm not certain that we are capturing the correct data to report EVM (i.e., Physical % Complete), and I was unable to find any videos on YouTube.
    Also, I noticed that Project Server 2010 defaults to reporting EV in Dollars.  Can we set it up to report in Hours instead?
    Julie  

    Hi Julie,
    If you allow to jump in to complement Dale's excellent reply and comment some of your concern...
    5. The status date is a fundamental parameter while talking about the EVM (it is ANYWAY a key setting for tracking projects with MS Project). The EV field will take into account actuals up to this date. Meaning that if your project plans have been updated
    by the PM on tuesday and you are running the analysis on friday, you set the status date to tuesday and the uncomplete work between tuesday and friday will not be considered as late work since you are running the analysis as of tuesday. The status date can
    be set from the "project" tab either in the project information dialog box or directly in the project tab, status group.
    6. MS Project proposes 3 EVM tables by default. A table is a predefined set of column which composes a view, together with a Gantt chart or a timephased grid. If you go to the view tab, click on "tables" then "more tables",
    you will find EV, EV cost indicators and EV Schedule indicators tables which will display the out of the box EVM fields calculated by MS Project based on the costs, actuals, Baseline, status date.
    Then about the cumulative data, you might be refering to S-curves which are a representation allowing you showing the cumulative values of the EV. To do that, you'll have severals ways:
    Use the cumulative calculated field in the visuals reports
    Create
    Dashboards from the report tab using the cumulative data (actual, Baseline, cost)
    Create
    MDX mesures in the OLAP cubes for cumulative data and create excel reports
    Develop custom SSRS reports
    Buy a 3rd-party addon
    Finally please let me give you an excellent reference for the EVM in MS Project with EPM Central blog articles:
    http://www.epmcentral.com/msproject/evintro.php
    http://www.epmcentral.com/msproject/evprereq.php
    http://www.epmcentral.com/msproject/evterms.php
    http://www.epmcentral.com/msproject/evexplain.php
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, P-Seller |

  • Project Server 2010 - Assigned tasks not visible in PWA

    Hi,
    When I enter an issue on a project site, the assigned issue is not visible in the PWA under Issues & Risks.
    Based on this link (http://social.technet.microsoft.com/Forums/en-US/f5abd024-3c9a-47f8-a7cb-7743fafebf2b/project-server-2010-cannot-see-assigned-issues-and-risks) I have tried to solve it however without success.
    In the queue jobs I have the following error details:
    General
    Reporting Wss list sync failed:
    ReportingWssSyncListFailed (24018) - 1100. Details: id='24018' name='ReportingWssSyncListFailed' uid='6c8a0779-3c9f-4d25-a81c-04d69d6fce1d' SPListType='2136b7a0-03b9-4547-8b2d-c66497accd08' Error='1100'. 
    ReportingWssSyncListFailed (24018) - 1101. Details: id='24018' name='ReportingWssSyncListFailed' uid='1573855e-b176-44cc-bf92-8959d167f8fe' SPListType='2136b7a0-03b9-4547-8b2d-c66497accd08' Error='1101'.....................................
    Reporting message processor failed:
    ReportingWSSSyncMessageFailed (24016) - RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried.. Details: id='24016' name='ReportingWSSSyncMessageFailed' uid='839ed0b8-6b8c-4bd5-bfbe-540349c1f27a' QueueMessageBody='ProjectUID='2136b7a0-03b9-4547-8b2d-c66497accd08'.
    ForceFullSync='False'. SynchronizationType='All'' Error='RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried.'. 
    ReportingWSSSyncMessageFailed (24016) - RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried.. Details: id='24016' name='ReportingWSSSyncMessageFailed' uid='b0e773af-5cc3-4965-85b3-a4d8050e86f5' QueueMessageBody='ProjectUID='2136b7a0-03b9-4547-8b2d-c66497accd08'.
    ForceFullSync='False'. SynchronizationType='All'' Error='RDS failed while trying to sync one or more SP lists. The RDS queue message will be retried.'............................................
    Queue:
    GeneralQueueJobFailed (26000) - ReportingWSSSync.WSSSyncMessageEx. Details: id='26000' name='GeneralQueueJobFailed' uid='07edaa28-647c-4dee-974e-06f47e4b4e40' JobUID='899bd048-2c19-4176-bd6c-1b45b8379a40' ComputerName='NLHGOL7FPR' GroupType='ReportingWSSSync'
    MessageType='WSSSyncMessageEx' MessageId='1' Stage=''. For more details, check the ULS logs on machine NLHGOL7FPR for entries with JobUID 899bd048-2c19-4176-bd6c-1b45b8379a40.
    As I understand this error could be due to a mismatch between the fields that are 'standard' in the project server and fields that are op the project site.
    If the reporting database could not sync, will consequently also the issues not be visible on the PWA??
    Any suggestions how to solve this?
    Regards,
    Dirk

    Hello,
    Yes, if the Issues & Risks are not being synchronised to the Reporting database then this will impact the issues & risks appearing on the PWA homepage reminders web part. See this post on how the data gets to the Reminders web part in Project
    Server 2010:
    http://pwmather.wordpress.com/2012/07/13/projectserver-active-issues-and-risks-on-pwa-reminders-web-part-ps2010-sp2010-sharepoint/
    The error you are seeing is probably caused by the default Issue or Risks columns being edited or removed from the Issues or Risks lists. It might be worth taking a look at this post:
    http://pwmather.wordpress.com/2011/06/20/project-server-2010-project-site-default-fields/
    Paul
    Paul Mather | Twitter |
    http://pwmather.wordpress.com | CPS

  • Project Server 2010 Active Directory Synchronization - duplicate Windows Name - Event ID 7734

    Environment: SharePoint Server 2010, Project Server 2010, SP2, DEC 2013 CU (Farm Build number: 14.0.7113.5001)
    Scenario: 
    Domain user has been added to the Active Directory group being synchronized with Project Server for the Team Members group.
    That user has participated as a team member in numerous projects, added documents, been assigned tasks, typical project stuff...
    Employee quits.
    AD account is deleted. (NOT deactivated or moved into another OU)
    Time passes...
    Employee gets rehired.  NEW AD account is set up: same display name, SamAccountName, email address, different GUID of course.
    Daily Active Directory job runs again and throws event ID 7734 and the sync ends with a partial fail.
    I understand why this is happening.  Solutions I've found point me to deleting the Enterprise Object resource in Project Server and then rerunning the sync.  Sure, this works BUT won't all of the previous documents, tasks,
    etc. be disassociated from that user?  If so, this is not ideal.
    2 questions:
    Is there a better way to deal with the fixing of the resource in Project Server to somehow link the old resource to the new resource allowing the sync to run successfully while still leaving the association to all old content intact?
    How are other organizations dealing with rehires when they have been added as resources in Project Server?  What is the best practice guidance from Microsoft on this?  Are other companies not actually deleting AD accounts when users leave organizations
    or are they putting them into a "ARCHIVE" OU or something like that? This happens at least half a dozen times a year at my company. We would like to keep our AD as clean as possible, but this appears to change our approach.
    Any suggestion/guidance is appreciated.

    For the question to relink the new account to the account which is already available in Project Server. You will have to update the WRES_AD_GUID to Null for the the Resource in MSP_RESOURCES table in the published database.
    Whenever a users gets synchronized to the PWA his ADGUID, SAMAccountName, Display Name, Email Address and DepartmentName is Synchronized from AD to Project Server. When the user was deleted and recreated the ADGUID got changed. During the next sync, project
    found the user with similar properties but different ADGUID which was updated in WRES_AD_GUID column in MSP_RESOURCES table. Hence it says that there is a duplicate account in the table with the same properties but a different ADGUID
    Nullifying the WRES_AD_GUID column value in MSP_RESOURCES table should get the user synchronized to Project server in the next sync.
    Cheers! Happy troubleshooting !!! Dinesh S. Rai - MSFT Enterprise Project Management Please click Mark As Answer; if a post solves your problem or Vote As Helpful if a post has been useful to you. This can be beneficial to other community members reading
    the thread.

  • Project Online - Schedule PDP disappearing for some Project Owners and Project Server Administrators Group

    Current Project Online environment is currently setup with Project Server Permissions Mode. All projects follow a customized workflow that enables Schedule PDP on Planning Phase/Stage, among other rules. For some users the workflow and
    expected PDPs are working fine, but for other the Schedule PDP just disappears under unknown conditions, even if they are part of the Administrators Group. Has anyone come across these behaviour?
    Saludos!

    As you said they belongs to Admin group it means they have required permission still double check the permission assigned to the users.
    Also ask those users to try to log in form different system then check is issue is occurring. 
    If this issue is occurring for few users then this may be because of Browser. check the following :
    1. Open IE then internet options --> Security --> Trusted Site and add your PWA site. then check
    2. If still issue is occurring then click on F12 button then select browser mode as IE 9 then check.
    kirtesh

  • Proj Server 2010 Dashboard Designer Not Reporting Future Capacity

    With information from Project Server 2010 (PWA) and using Dashboard Designer I’ve designed a time-phased report (by month) to show past effort (Measure - Actual Regular Work) against capacity (Measure – Capacity) which displays accurate information. 
    I’ve designed a similar report to show future planned work (Measure – Remaining Work) against capacity (Measure – Capacity). 
    Planned work reports accurately but for some reason this report does not show future capacity. 
    Resources in the pool have latest available dates.  Can someone please tell me what I need to do to report future capacity in Dashboard Designer? 
    Thanks in advance!

    Resource Capacity Settings are set to:
    Months behind : 1
    Months ahead: 12
    The report uses Portfolio Analyzer Cube. 
    The OLAP cube builds every 24 hours.  Database date range is “Use the earliest project start date and the latest project finish date”. 
    Thank you for your help.

  • Exchange Server 2010: Incoming mail not delivered

    I have an Exchange Server 2010 Standard with all recent patches and updates. 
    -It has been in service for 3 years without any issues. 
    -There is plenty of hard drive space for the logs and the data (over 100GB in each)
    -The current size of the mail database is 150GB
    -There is no registry entry in place limiting the size of the database ([url="http://technet.microsoft.com/en-us/library/bb232092.aspx"]Database Size Limit in GB as outlined here[/url]
    Starting a few days ago, incoming mail is reaching the server but not being delivered to user mailboxes. Internal mail works fine when this happens. Looking at the Queue Viewer doesn't show anything abnormal. The Submission Queue shows nothing.  
    It is only after I reboot the Exchange Server that the Submission queue will show all the messages waiting to be delivered and they will all be delivered successfully after the reboot. The event logs do not show any error messages.
    The server will continue to run fine for a few hours and then the problem starts all over again.
    What could be causing this?

    Any 3rd party antivirus/anti-spam software installed on the server? If so, disable and test.
    Twitter!: Please Note: My Posts are provided “AS IS” without warranty of any kind, either expressed or implied.

  • Project Lite Users - My Apps not showing Project

    I have a handful of Project Lite licenses. When I assign users to the Project Lite license, they do not get the Project Web App icon in their portal. They only way of accessing the project is to the direct link: https://domain.sharepoint.com/sites/pwa/default.aspx
    How do I add that link or the Project Web App icon to the users (with Project Lite Licenses) Office 365 portal?
    Thanks in advanced,
    -Genesis

    Hi,
    for licensing Information, Project Lite
    is not a stand-alone product. It can be used only for  projects managed
    with Project Online or Project Server.
    thanks
    diramoh

  • Microsoft Exchange Server 2010 SP3 update to Update Rollup 8-v2 for Exchange Server 2010 SP3

    i have Microsoft Exchange Server 2010 SP3 and i would like to update to Update Rollup 8-v2 for Exchange Server 2010 SP3. 
    what is the best way to do so?
    my current env:
    Name                : xxxxxxxx
    Edition             : Standard
    AdminDisplayVersion : Version 14.3 (Build 123.4)
    ServerRole          : Mailbox, HubTransport
    Site                : domain/Configuration/Sites/xxx
    Name                : yyyyyyyy
    Edition             : Standard
    AdminDisplayVersion : Version 14.3 (Build 123.4)
    ServerRole          : Mailbox, ClientAccess, HubTransport
    Site                : domain/Configuration/Sites/yyy
    Name                : cccccccc
    Edition             : Standard
    AdminDisplayVersion : Version 14.3 (Build 123.4)
    ServerRole          : Mailbox, ClientAccess, HubTransport
    Site                : domain/Configuration/Sites/ccc
    Name                : dddddddd
    Edition             : Standard
    AdminDisplayVersion : Version 14.3 (Build 123.4)
    ServerRole          : ClientAccess
    Site                : domain/Configuration/Sites/ddd
    Name                : iiiiiiii
    Edition             : Standard
    AdminDisplayVersion : Version 14.3 (Build 123.4)
    ServerRole          : Mailbox, ClientAccess, HubTransport
    Site                : domain/Configuration/Sites/iii
    thanks
    Mayson

    Consider referring to the articles below and that explains it all.
    Install the Latest Update Rollup for Exchange 2010 - https://technet.microsoft.com/en-us/library/ff637981.aspx
    Applying Service Pack and Rollup Updates on Exchange Server 2010 (Part 1) - http://www.msexchange.org/articles-tutorials/exchange-server-2010/management-administration/applying-service-pack-and-rollup-updates-exchange-server-2010-part1.html
    Pavan Maganti ~ ( Exchange | 2003/2007/2010/E15(2013)) ~~ Please remember to click “Vote As Helpful&quot; if it really helps and &quot;Mark as Answer” if it answers your question, “Unmark as Answer” if a marked post does not actually answer your
    question. ~~ This Information is provided is &quot;AS IS&quot; and confers NO Rights!!

  • Premiere Pro CS6 Project Manager gives error & will not manage project - OS X Lion 10.7.5

    Premiere CS6 project manager reports  an error and will not manage my project. I have tried several times with both "Create New Trimmed Project" and " Collect Files and Copy to New Location". I have also tried to manage the project with options checked and unchecked (Include Preview Files, Include Audio Conform Files, Rename Media Files to Match Clip Names). Every time I try to manage the project, the process takes a few hours and then gives an error asking me to try again.
    The project is 90 minutes long and uses multiple footage formats:
    Sony FS100
    Sony NEX7
    Sony NEX-5n
    Canon C300
    Canon 5DmkII
    Panazonic HVX200
    My computer is:
    Processor  2 x 2.66 GHz 6-Core Intel Xeon
    Memory  12 GB 1333 MHz DDR3
    Graphics  ATI Radeon HD 5770 1024 MB
    Software  Mac OS X Lion 10.7.5 (11G63)
    Is this a bug, or are there specific things I can do to troubleshoot the problem? I have read of issues with AVCHD. I have confirmed all of my AVCHD folders are intact. Any other Ideas?
    THANKS!

    I have this same problem on a Mac with CS6. I was simple trying to archive a project using the "collect files" option. After five or six hours of troubleshooting (Thanks Adobe) I have narrowed it down to MXF clips that came over in a Final Cut EDL (Projects created in PP with MXF files seem to be fine).  In other words, as I was transitioning from FCP to Premiere Pro, I sent four or five projects out of FCP as an EDL, opened them in PP and continued to edit.  It seemed to work really well until I attempted to archive my media.  If there was a single raw MXF file in the timeline (Not the project panel for some reason) the Project Manager would give me the standard error:"An unknown error occurred during the Project Manager operation. Please save your project and retry the operation.".
    I have found two solutions that seem to work, both of which are a pain in the ax. 
    Option 1: Save the original project file only to an archive folder.  Then delete all the old timelines from the project, and save the project with a new name.  Create a new timeline and just drag all the raw video and audio into it. (Project Manager needs a timeline of some sort to archive) Then use the Project Manager to archive the modified project.  If I need the project in the future, I'll need to open the original PP project and relink all the media from the archived "media only" project folder. 
    Unbelievably, if you were to take this route and then re-edit the project in the future, it looks like you would run up against the same archiving issue AGAIN next time (At least using CS6). You'd have to go through all the steps above to archive it a second time. Depending on the size of your project, you may want to take option 2 and get the pain over with once-and-for-all.
    Option 2: If you only have a couple of MXF files in the timeline (in my case I had mostly renders from AE by the time I was done and THAT raw project had archived in AE just fine) you can export the raw MXF files to another format, then replace the media in your project panel.  Finally, use the Project Manager to archive the project like you should have been able to in the first place if Adobe had written the code well in the first place!

Maybe you are looking for

  • Windows 8.1 & IR C3100 not functioning together

    We have used our IR C3100 for years on our small business network through ethernet cable and wireless with Windows XP and 7.  September of 2013 I purchased a new laptop with Windows 8 (x64).  I set up the appropriate driver and it printed to the C310

  • Sun JSC2 - How to download files to client

    Hi, imagine a document management site. I want to have a list of files with links that users can click to download them. Users can upload files (with handy File Upload component), and they get saved as byte streams to a file or database or whatever.

  • Can't Center SWF image in Browser

    I've designed a website in flash and have inserted the SWF file into Dreamweaver, I can edit everything else I need, but for some reason - no matter what I do or try, I can't center this SWF image in Dreamweaver so the SWF file will rests in the cent

  • In CS6 - how can I un-blur text within a photo taken at a seminar of a powerpoint slide presentation

    Is there a way in CS6 to un-blur or "clean-up" text within a photo taken during a powerpoint slide show presentation at a seminar ?

  • Using the $ to lock a cel in a formula

    Hi there, when i put a string in my formule to block the cel ( so i can draw the formule down) it just works fine. But after saving, closing and re-opening my file the formula has changed and doesn't work anymore! for example; I put an amount in cel