Results Recording through QE 11  - Determine one MIC w.r.t another MIC

Hi All,
While doing Results Recording through QE11, one MIC (Say 'T') )needs to be automatically calculated ,whereas it was manually entered until now.
The value for 'T' should be picked from some Z table depending on some key fields , of whiich another manual MIC (say 'A' )value is a key field.
I can create the Function module and assign it to the MIC in formula. But I am not sure how to pick up the value for MIC 'A' at run-time.
Before saving itself, when 'calculate' button near 'T' is pressed, the FM should be triggered and it should use the value for MIC 'A' for picking value for 'T' from Z table.
Please advise if any FMs/BAPIS are there or any other method.
An F1 at 'A' yielded field QAQEE-SUMPLUS in 'Result' field and QAMKR-ORIGINAL_INPUT from 'Orig. Val' filed of which both are structure fields.
Thanks,
Neethu

I'm a maybe little late, but i will try to explain my own problem.
I'm also working for QM.
I want read data from QAQEE-ORIGINAL_INPUT and i cant and i did succed when i going to see inspection report.
I just have to make some marks in field Accessories for report and u will get data from this field.
But, if i want to read the same data in another place in sapscript i have problem.
It simple i cant get data from structure, is this because the program for form is writen for specific point when it must be write out?
Sorry for my english.
Tnx.

Similar Messages

  • Just bought a new iPod touch 16G - I think it's a 5th gen. - I used my old iPod to record rehearsals.  The new one is stating that my Belken mic is not compatible.  Can I record with this new one?  If so, what do I need for a mic?

    Just bought a new iPod Touch 16G - (I think it's a 5th gen.).   I used my old iPod to record music rehearsals.  This new iPod is stating that my old Belken mic (with new adaptor) is not compatible.  Does this new iPod Touch have ability to record audio?     If so, what do I need for a mic??

    Thanks very much!   I found the app, tested it, and it sounds fairly lifelike.    Big help!!

  • Operation Number in Result Recording

    Dear QM Masters,
    We are preparing BDC for result recording through QE11 as inspection lot will be with inspection points. Task list for specification will have same MIC assigned to two operation/phase i.e. phase 40 and phase 60. But as we have to record result for same characteristics twice at seperate work-center with seperate operation/phase number, which field we can take as primary key for operation identification as in QAMV table we dont have operation/phase fied. Can we use VORGLFNR field named as NODE of QAMV and if yes then what can be the logic?
    Please help to find the solution as our developement is stopped because of this issue.
    Any guidence will be great help and will be rewarded.
    Thanks and regards,
    Devang

    Hi,
    Step by step how to find the operation nos and characteristics nos.
    1) From QALS table get the order number (AUFNR) for the field inspection lot no.(PRUEFLOS)
    2) Go to table AFKO and give the input AUFNR (order no) which is got from QALS table. Find the field AUFPL from that AUFNR value from AFKO table.
    3) Go to table AFVC and give the input AUFPL. You will get the AFVC-APLZL which is unique for each operation nos that is AFVC-VORNR. Now you have the APLZL from AFVC table.
    4) Go to table QAMV and give the input inspection lot no (PRUEFLOS) and APLZL value in the field QAMV-VORGLFNR. Meaning AFVC-APLZL=QAMV-VORGLFNR. Fetch the characteristics nos that is QAMV-MERKNR.
    I hope this will solve your problem.
    Regards,
    Manoj

  • Deleting MIC or Characteristics in QE01 or Result Recording(QA32)

    Hi friends
    Any t.code for deleting MIC or Characteristics or Parameter in QE01 or Result Recording(QA32)
    Thanks & Regards
    Gajendranath

    Hi
    while dong the RR you can not delete the char/MIC as while creation of inspection lot only task list gets attached.
    So what you can do the remove the task list from the lot,
    In QA02>enter Inspec Lot->click on Reset sample.--->save.
    This will remove the task list & status of lot will become CRTD from REL.
    Now you can change the task list & attach the task list through QA02>click on Inspec specs->save.
    Regards
    Sujit

  • Multiple result recording against single MIC

    Dear Experts,
    In Case of calibration, for example i have assigned as one MIC to Operation, now after generation of Inspection Lot can we record multiple reading against single MIC. Please guide
    thanks
    DM

    Hi,
    I presume that apart from inspectopn point u have done all necessary steps .
    Is lnspection lot generating .
    1)If it is get generated then while result recording it will ask for identification.
    2)Enter any indentification (for ex a, b, c etc ) and save the result. Don't take UD as u want to take multiple result recording for that MIC
    3)Again go to result recording tab
       Follw step 2  & 3 as long as u want to thak no of results.
    IF not clear clear tell me ur requirement in detail & what u steps u have applied.
    Amol

  • How to see MIC number in Result Recording Screen

    Hi,
    During result recording  (thru QE51N/ QA32 ) in result recording screen we see MIC short text but not the MIC number.
    How to get the MIC number during result recording screen?
    Already we have used Info Field for this & get the MIC number Directly in result recording screen but User like to go for other option.
    Thanks in advance.

    I  think  you wont get MIC no instandard SAP

  • An MIC is accept and reject at the same during result recording

    Hi,
    If I have a checked sign on both of the Acceptance checkbox and Rejection checkbox (status:2, and valuation: yellow thunder sign icon) during QE51N, what does it mean in term of result recording, defect, and notification, and usage decision?
    I am stuck as I don't know how to treat this MIC.
    thanks
    YY

    Hi Herment,
    There is no such message you mention and the system allow me to save with status 2. However, the valuation field display a Yellow Lightning icon.
    Now that I press the lock button (i.e. close) and clicked the save button, the system does not allow me to make any changes to this MIC, and which means there are two check sign on the Accept and Reject checkboxes now.
    How to deal with it?
    Thanks
    YY

  • Unplanned MIC during result recording

    Dear Gurus,
    Can anybody tell me what is means by Unplanned MIC.
    How do I create the same in Inspection Plan and make result recording.
    Srinivasan.

    Dear Srinivas,
    Normally all MICs are copied from the task list.
    The business requirement may arise to include new MIC in the result recording screen.
    Any number of MICs can be inserted in the result recording screen.
    But deletion is not possible.
    As these Master Insp. Char. are not in the original task list,
    They are called unplanned MIC.
    To add a MIC,in general tab  "+" sign --> you can click.
    or Edit --> craete additional Characteristic or F5 in the key board
    You will get a pop up window.
    Name of the window --> Master Insp. Char. selection
    The window contains three line items
    1. Master Inspec. Charac. -
    2. Plant -
    3. Version -
    Ex.: MIC : MR001004
    Plant :1000
    Version : 1
    Enter.
    We get the next popup window
    Name of the window :Change the specification of unplanned char.
    Normally you have to mention the "SAMPLING PROCEDURE".
    Click "CHECK" BUTTON.
    Click "COPY" BUTTON.
    We get the message as "Inspection characteristic was created with number 8000"
    Similarly next MIC serial number will be 8010.
    ie 8000, 8010, 8020, and so on.
    8000 series clearly indicates that these MICs are created manually in the Result Recording Screen.
    When ever you want to check the new requirement ie thro the MIC, create it manually in RESULT RECORDING SCREEN.
    This is called "UNPLANNED MIC".
    Hope that this is clear.
    Raghu Sharma

  • I can record and hear me recording through the computer's built in mic, but can't get the external mic and headphones to work., The preferences are set for the external mic and headphones...

    I can record and hear me recording through the computer's built in mic, but can't get the external mic and headphones to work., The preferences are set for the external mic and headphones...

    What operating system are you using? Is it on a Mac or a PC? Which preferences are set for external mic/headphones, Audition's or the computers?

  • Recording through the Mac Audio Tracks rather than through the Mic.

    I figured this would be very handy since I'm just recording the sound from a YouTube video, I don't want to have to use the mic to record the sound, If it's possible to save the Mac Audio Tracks, which is basically anything that comes out of the speaker, to a file to be used by Garageband later? Or is there a way to record, not through the mic, but using the Mac Audio Track through Garageband? It would help because I realized when I recorded through the mic that I had to worry about everyone around me being quite for a few seconds only to realize that the fan was running full boar which made the quality terrible. Just looking for an alternative. Maybe a program that records the Mac Audio Tracks? Sorry for the long-winded post.

    I know a way around this as I had the same problem once. I bought a small lead with stereo mini jack to stereo mini jack which enabled me to connect the headphones socket to the line/mic in socket. This means that any sound your computer makes can be recorded directly using any recording application, including Garageband. No fear of extraneous noise as it is a direct connection not microphone. There may well be a purely 'software' method also but I can confirm that this does work anyway.

  • I have an Irig but sound still records through mic on my ipod. How do I know if my iRig works??

    I have an Irig but sound still records through mic on my ipod. How do I know if my iRig works??

    Does Settings > GarageBand > Crosstalk Protection > On help?
    tt2

  • QM-Result Recording transfer from one material to another material

    Dear QM masters,
    I have following scenario:
    Material A has Material B as a component and Material B has Material C as component. Material A is batch managed. Material C has in-process inspection with partial lot using inspection point functionality. Last result recorded for this in-process inspection should be used for quality certificate of Material A.
    Thanks a lot in advance for any help extended and will be rewarded with maximum points.
    Thanks and regards,
    Devang

    Since you are in ECC 6.0 you can also use batch derivation to have the components values copied to the next material being made.  In this way, batch values for Material C get copied to material B batch and material B batch values get copied to Material A batch. 
    Then on the cert, you only need to report the value from the material A batch.  No need to set up the result from production chain in the COA profile.
    Craig

  • Recording Dates in Results Recording

    Hi.
    I have an inspection with a task list.  Several samples will be tested each time an inspection lot is created.  I have a number of MICs that are quantitative / calculated to determine results of lab testing - this is all working great.  The problem is that for each of my samples I need to be able to document general information about the sample.  The types of information that needs to be documented are, for example, dates and sample numbers (not serialized using SAP). 
    Primarily these dates need to be used to generate date range specific reports of the lab results.   It is for this reason that I do not want the users documenting dates in the inspection description field in results recording.
    Does anyone know if using the QM_INPUT_PROCEDURE BAdI can the result field of a quantitative MIC be formatted as a date?  Or has anyone had a similar problem that they have been able to solve?  Is Sample Management / Physical Samples the direction to take?
    Thank you very much in advance,
    Cristin

    Ok.  Here's one way around this.
    You can read this post: 
    http://sapfans.com/forums/viewtopic.php?f=27&t=14682&p=43885&hilit=datecharacteristicinspectionlot#p43885
    But basically you use numeric MIC and the date is recorded in the form yyyymmdd. So for today it would be 2010622.  You can even set a spec range at the begining of each year.  So the range would be 20100101 to 20101231.  This could help cut down on typos as well.
    This number then gets copied to the batch record to a linked hidden numeric characteristic.  A dependency is used to convert the number to the appropriate date.  The dependency then updates a second characteristic with the date.  It is this second date characteristic then that you can use in your reports.  If you want to make sure the date formatted characteristic is changed due to additional testing or sampling you can include an  IF NULL or an IF INITIAL statement in the dependency so once the characteristic has a value, it wouldn't be updated if the dependency was called again.
    I am guessing each blood donation is being set up as a separate batch number.
    FF

  • RESULT RECORDING PROBLEM

    Dear Gurus,
    I am facing problem I have maintained formula for paricular MIC,e.g Zn-for this MIC i have to calculate the percantage as 100 minus balance of the remaining MICs eg i  have maintained in this form--1
    100-(C9010C9020C9030C9040C9050C9060C9070C9080C9090)
    Please note i have maintain the folowing parameters in control indicators for the MICs from 10 to 90 in the Inspection plan
    1) Sampling procedure
    2) Required chara
    3) single results
    4) Fixed scope
    5)Record measured values
    6)print
    7) documentation
    and only for the MIC which formula is maintain i have maintained CAL CHAR.
    when i creat a purchase and do migo an inpsection lot is gnerated.
    when go to t.code QA32 to record results in RECORD RESULTS CHARACTERISTICS OVERVIEW
    I HAVE NOTICED THE FOLLOWING PROBLEMS
    1) FORMULA IS NOT BEEN CALCULATED.
    2)INSPECTED COLCUMN NEXT TO SINGLE VALUE IS AN INPUT SCREEN.i.E-Number of Inspected Sample Units--(WHAT I MEAN ITS NOT GREY FEILD-THE VALUES HERE SHOULD BE 1 AND GREY )
    3)ALSO THE SINGLE VALUE TAB IS GREY NOT USUAL-IF CLICK ON IT THE TAB DROP DOWN.
    I HAVE RUN THIS SCENRIO IN MY DEVELOPMENT SERVER AND IT WORKED PREFECTLY,BUT MY CLIENT SERVER I AM GETTING THIS PROBLEM
    WHAT ARE SETTING I AM MISSING.
    Regards
    Ram
    Edited by: RAMKUMAR WARIYAR on Feb 24, 2009 4:41 PM

    Dear Ram
    1) As the sample size was 1 system was taking this as Summarised recording & that is the reason why the system is showing 3 tabs instead 4
    2) Please do the following setting in Config : SPRO>QM> Basic Setting> maintain setting for plant level>Plant> Result recording  > untick Summ. Recording n=1.
    If you had ticked this means that the results recording will always be summarized if n = 1 (for example when inspecting one unit or 1 ml).
    please do check now whether the formula is working for a new lot and you have 4 tabs in RR
    Was a good question to solve
    Regards
    gajesh

  • I can record midi data from my Mason & Hamlin Piano Disc Pro Record through my MOTU Traveller into Logic but Logic won't send midi data out to the MOTU Traveller to the Piano Disc player

    Hello All,
    I can record midi data from my Mason & Hamlin Piano Disc Pro Record through my MOTU Traveller into Logic Pro 9.1.8  but Logic won't send the midi data back out to the MOTU Traveller and thus to the Piano Disc player. I got it to playback one time but have no idea how and when it did it was looping or something because the velocity was way high coming back in and the damper pedal was slamming down. When I play a key on the piano the midi "in" light on the Traveller lights up. When I play the track back on my computer no lights blink on the Traveller and when I did the apple midi studio test in utilities when I play a key I get the confirmation signal noise and the Traveller blinks when I click on the down arrow of the Traveller in the Apple midi studio test the midi out light on the traveller never lights and the signal light on the piano does not blink either. No outbound signal at all...
    I have messed with every possible parameter I can find and and have had help from one of Piano Disc's premier editors but no luck. The piano was prepped for me on Logic so it would work with my studio.  I'm positive it's my fault and I'm overlooking something really simple and stupid but what!??!
    Somebody please help.  Thank you all in advance for ANY ideas you might have!

    Blues Piano,
    I'm not sure if this will be a help or not.  I'm so Logic Pro wet behind the ears that I make newbies look experienced.  However, I'm not expecting many on the Apple support forums have a PianoDisc system, much less one with the new optical record strip.  While I don't have any record strip on my PianoDisc, I do have a PianoDisc iQ that's only a month old.  I've been playing converted paper scrolls from hundred year old player pianos through it via the MIDI in port of the PianoDisc CPU.  I've found I have to open the MIDI file in Logic Pro (10.0.4) then go to <Track><New External MIDI Track> then copy the existing track to that new external track.  Only then can I see in the Track inspector (defaults left side of screen with the Icon for the instrument) the "Port" parameter.  Then I can select my external MIDI device in that Port selector. 
    I've also encountered problems with the PianoDisc not using enough force on the notes or using too much force.  To get around this problem, until I understand Logic better, I've been setting minimum and maximum volicities.  To do that I right click on the track and select "Select All."  Then I right click again and select "MIDI" then "MIDI Transform"  then "Velocity Limiter."  In the resulting pop up window in the center is a drop down and you can play with the velocity from "MIN" to "MAX" along with "ADD" "SUBTRACT" etc. 
    I hope this helps.  I envy you your Mason & Hamlin.  If you need more help on this just email me at pfleischmann at mac dot com.

Maybe you are looking for

  • JSP does not have visibility of java classes in simple Web Module Project

    Dear Experts I am developing what I thought would be a very simple Web Module Project for a simple webservice to allow a user to logon to Netweaver Portal with a simple logon and password. I have not done this in over 8 years, and am somewhat rusty.

  • Reg Submit command

    I have used the submit command  in my program as follows: SUBMIT rbdapp01 WITH SELECTION-TABLE rspar_tab EXPORTING LIST TO MEMORY  AND RETURN. This is working fine. But I want the updated values present in the program rbdapp01 populated in my interna

  • Windows, Design Premium, & Design Standard CS4 Re-install

    I need to re-install my Windows software. I have a serial number for CS4 Design Premium & CS4 Design Standard. Will I be able to re-install all of these CS4 programs iwthout any "hiccups" once I wipe my slate clean with a new Windows install?

  • HPS Promotion - How i Can do?

    Hello Somone could tell me how using the PROMOTION System of Performance scorecard (9.3.1.0). We try to use but have this message in the log: Hyperion][Oracle JDBC Driver][Oracle]ORA-00942: table or view does not exist while executing SELECT "HPS_EXT

  • Validate form - repeat email address?

    I'm playing around with Adobe's spry system and integrating the validation functions into my online form. Could someone please explain or direct me to a tutorial or guide on implementing a function where the user must insert their email address twice