Saving of different Material code in the system while Creating material

Hi,
Anyone can help me in following .
While creating material number, there should be some User exit which is going to change the logic for saving of material number in the system.
Example:
Division and material Group should be added into the predefined number range.  Number range defined for raw material is 100000 to 199999. If division is 1A, and Material group is M01. The first number generated by system is 100000 , where as during saving into the table NUMBER SHOULD BE saved as 1AM01100000 & we must be able to work on the new number.
If any query pl .revert.
MG.

Hi manish,
This is possible using enhancement.
Use the User Exit MGA00001
and code the below like :
cmara-matnr = cmara-matnr+7(11).
CONCATENATE cmara-matkl cmara-spart cmara-matnr into cmara-matnr.
set PARAMETER ID 'MAT' field cmara-matnr.
CALL FUNCTION 'CONVERSION_EXIT_ALPHA_INPUT'
EXPORTING
input = cmara-matnr
IMPORTING
OUTPUT = cmara-matnr
Hope it will solve your problem.

Similar Messages

  • Error while creating Materialized View step 3 of 6 using wizard

    have oracle 9i Rel 1 on Windows 2000 server. Master Site has been setup. Database links are created at Materialized view site. But while creating Materialized View Group using wizard there is following error on step 3 of 6.
    Statement:----------------
    /*OracleOEM*/ SELECT 1 FROM SYS.dba_constraints@masterdbname WHERE OWNER='username' and table_name='tabname' AND constraint_type='P'
    Stack Trace:----------------
    ORA-00942: table or view does not exist.
    ORA-02063: preceding line from masterdbname.
    All parameters for replication are correct.
    Please help me early.
    Thanks

    Hello,
    In the masterdbname, logging as sys user, you must grant select permission on sys.dba_constraints view to mvadmin_dbname user (where dbname is the replicated database name).
    Regards,

  • Error while creating Materialized View step 3 of 6

    I have oracle 9i Rel 1 on Windows 2000 server. Master Site has been setup. Database links are created at Materialized view site. But while creating Materialized View Group there is following error on step 3 of 6.
    Statement:----------------
    /*OracleOEM*/ SELECT 1 FROM SYS.dba_constraints@masterdbname WHERE OWNER='username' and table_name='tabname' AND constraint_type='P'
    Stack Trace:----------------
    ORA-00942: table or view does not exist.
    ORA-02063: preceding line from masterdbname.
    All parameters for replication are correct.
    Please help me early.
    Thanks

    Hello,
    In the masterdbname, logging as sys user, you must grant select permission on sys.dba_constraints view to mvadmin_dbname user (where dbname is the replicated database name).
    Regards,

  • Bulk Insert Task Cannot bulk load because the file could not be opened.operating system error error code 3(The system cannot find the path specified.)

    Following error i am getting after i chnaged the Path in Config File from
    \\vs01\d$\\Deployment\Files\temp.txt
    to
    C:\Deployment\Files\temp.txt
    [Bulk Insert Task] Error: An error occurred with the following error message: "Cannot bulk load because the file "C:\Deployment\Files\temp.txt" could not be opened. Operating system error code 3(The system cannot find the path specified.).". 

    I think i know whats going on. The Bulk Insert task runs by executing sql command (bulk insert) internally from the target sql server to load the file. This means that the SQL Server Agent of the target sql server should have permissions on the file you trying to load. This also means that you need to use UNC path instead to specify the file path (if the target server in on different machine)
    Also from BOL (see section Usage Considerations - last bullet point)
    http://msdn.microsoft.com/en-us/library/ms141239.aspx
    * Only members of the sysadmin fixed server role can run a package that contains a Bulk Insert task.
    Make sure you take care of this as well.
    HTH
    ~Mukti
    Mukti

  • Windows Server Essentials 2012 error code: 2147942403 The system cannot find the path specified

    Running Windows Server 2012 Essentials with an external usb 3 drive as a backup device.  Using a Vantec hx enclosure with a WD Red drive. Last night the Dashboard saw the drive with about half the 4TB available for backup. A.M., I get "error code:
    2147942403 The system cannot find the path specified".
    Going to the server desktop, I see a message indicating that the usb device malfunctioned.  unplugging it, and plugging it back in, I now have it available via the dashboard.
    This has happened a couple times with two different drives in Vantec hx enclosures.
    A couple possibilities come to mind:
    the enclosures may both be bad...
    there is some problem with the system software and external usb drive.
    Thoughts?
    Suggestions for external enclosures?
    Thanks!

    Hi,
    According to your description, my understanding is that you cannot backup the Windows Server Essentials 2012 and got "error code: 2147942403 The system cannot find the path specified". You found the usb device malfunctioned. 
    Can you backup the server when you unplugged the usb device, and plugged it back in? If you can backup the server when you replug the usb device, you need to engage the vendor to resolve the hard drive issues.
    Best Regards,
    Mandy 
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Different tax codes in the MIRO for single service item

    Dear all,
    Customer wants to enter 2 different tax codes in the MIRO for single service item. How it can be achieved?

    >
    Milosavljevic Sreten wrote:
    > Just loudly thinking... what can be reason that one service for same invoice is taxable with two different tax codes? 
    >
    It is cross-counties transportation. Part of route outside company country is non-taxable, inside part is taxable. Amounts are proportional to distance and hence become known only at time of invoice receipt.
    Users do not want to create 2 separate invoices. They would like to have ability to enter 2 lines in MIRO. But I need your help to understand, how it can be done? Service receipt is done by single line (because actual taxable / non-taxable amount is unknown at that time). So, is it possible to enter non-taxable amount in MIRO in some additional line?

  • The user '*' preference item in the 'User - 6th Form Students Policy {E03166E7-A848-48B5-AA93-97B848AA9C13}' Group Policy object did not apply because it failed with error code '0x80070003 The system cannot find the path specified.' This error was suppres

    I am looking at an issue with users not getting specific group policies. 
    After searching a number of client computers I found that the following error
    The user '*' preference item in the 'User - 6th Form Students Policy {E03166E7-A848-48B5-AA93-97B848AA9C13}' Group Policy object did not apply because it failed with error code '0x80070003 The system cannot find the path specified.' This error was suppressed.
    I can find the folder in the Sysvol folder on all of the domain controllers. 
    The issue with end users seems to be that the proxy settings for internet explorer is not being applied. 
    Potential problems?
    one folder in sysvol entry is empty 
    \\<server>\SYSVOL\<domain.name>\Policies\{E03166E7-A848-48B5-AA93-97B848AA9C13}\User\microsoft\IEAK\LOCK
    or is this our issue
    The old method of configuring proxy settings  to Internet Explorer 9 has changed?
    https://support2.microsoft.com/kb/2530309?wa=wsignin1.0 
    http://thommck.wordpress.com/2013/11/08/the-new-way-to-configure-internet-explorer-proxy-settings-with-group-policy/

    Hi all 
    In administering this policy I am a little confused. 
    We have a policy that distributes proxy settings in the internet explorer maintenance settings section - however when opening this policy up in GPO editor the internet explorer maintenance section is not present.
    I plan to apply the settings via User/preferences/control panel settings/ internet settings (or registry settings from article) however I am unable to edit the settings for internet explorer maintenance and these will persist. Ideas????

  • What is the tcode for creating material receipt

    Hi,
    what is the tcode for creating material receipt & payment to the vendor

    Hi,
    You recieve your material from the vendor and do a Goods Reciept in MIGO with mvt 101. You can even enter via T-Code - MB1C.
    Once you get your Invoice for this reciept from your vendor, you then do invoice verification in MIRO.
    After verification, if there is no blocking of the invoices and is posted and released, a accounting document is released during the posting of MIRO. These documents are then referred by FI pals, who are responsible for the payment.
    Hope this gives you a clear picture.
    Anand
    Message was edited by:
            Anand.B.K.

  • Settings for the system to create single requisition

    MD04 shows there are two dependent requirements for a material.
    The MRP is creating for every dependent requirement  a new purchase requisition. So two purchase requisitions created for the two dependent requirements.
    But Business wants only one Purchase requisition should be created.
    For your information - The settings in the MRP4 is set on collective.
    Where are the settings for the system to create single requisition?

    >
    Sambit@sdn wrote:
    > Thanks for the reply, I absolutely agree with your clue (I had also proposed the same solution)
    > The lot-size used is lot-for-lot.
    > But the Business is not ready to bring a change in its lot size procedure.
    > Is there any other way to make this possible ? (Keeping lot-for-lot only)
    >
    >
    > Guys, the MRP control paramenter - Planning Mode in MD01 - Can this be helpful ?
    > Or any other suggestion ?
    Dear Sambit,
    In my understanding the above suggested is only way
    Planning mode MD01 will not play any role in this case
    May be some other experts may come into the picture & throw some light
    Good Luck !!!
    Regards
    Madhu

  • Can we create materialized view on the top of another materialized view.

    Hi ,
    can we create materialized view on the top of another materialized view.
    Thanks
    Naveen

    Welcome , Just remember is not good apporch to do that since performance when MV refresh
    Please mark this thread as answered .

  • BPC "The system cannot create the journal template"

    I am trying to create a Journal template in BPC but whatever I do I get the error message "The system cannot create the journal template"
    I am running BPC 5.1 and have tried with service pack 1 and now with service pack 5 installed. The system is on SQL Server 2000.
    Has anyone come past this problem?

    Hi Andy,
    Please check how many sheets are in a default excel workbook on your client. If less than three, BPC fails to create the journal template. If that's the case, try setting default number of worksheets to 3, then retry journal template creation.
    If the above is not the issue, then you'll have to check that reporting services is working correctly. As a first step, go to http://<app server name>/reportserver (or reportserver$<instancename> if you are using a reporting services instance and left it with the default name)
    If that page compiles and shows without error, then try http://<app server name>/ reports (or reports$<instance name>) If that one also compiles/doesn't give errors, then reporting services is working.

  • "The system cannot create journal template"

    While creating the journal template for my legalapplication using wizard i get the following error
    "The system cannot create journal template"
    am using category, group and time as my header dimension --
    group dimension contains the LC.
    please suggest what steps can be taken. Also while trying to access journal from etools we get the message journal not found.
    Thanks

    Hi Andy,
    Please check how many sheets are in a default excel workbook on your client. If less than three, BPC fails to create the journal template. If that's the case, try setting default number of worksheets to 3, then retry journal template creation.
    If the above is not the issue, then you'll have to check that reporting services is working correctly. As a first step, go to http://<app server name>/reportserver (or reportserver$<instancename> if you are using a reporting services instance and left it with the default name)
    If that page compiles and shows without error, then try http://<app server name>/ reports (or reports$<instance name>) If that one also compiles/doesn't give errors, then reporting services is working.

  • What would cause the screen to swith between backgrounds as if it is being controlled remotely? the system had created 7 new folders on it's own.

    System is currently switching between mutliple screens without me touching it. The system has created several new folders. The system is performing as if it is being remotely controlled.

    How recently did you switch?  If it's less than 60 days, then Verizon simply reinstates your previous account.  The fact that you were on the EDGE plan and mailed the devices back, and they apparently are somewhere in the system, could cause complications, and it might just work out that you just go back on the same plan and they set you up with the same devices.  I'm not sure how it will go - but since you are still being billed for the devices... 

  • [SOLVED] Backing up the system while the system is running?

    Is it ok if I backup the system while it's running? Or does it *have* to be done from a LiveCD?
    I was thinking of using this:
    $ sudo rsync -avx /* /mnt/Backup --exclude={/dev/*,/proc/*,/sys/*,/tmp/*,/run/*,/mnt/*,/media/*,/lost+found}
    Rsync will complain at the end that "some files/attrs were not transferred", but the backup works fine (as far as I can tell).
    Should I add "[...] > sometextfile.txt" at the end, to see which files weren't transfered right? Has anyone else done something like this before?
    Last edited by DSpider (2012-06-14 15:56:03)

    DSpider wrote:Rsync is not necessarily better, but it does the job. I'm planning on transferring the system to a loopback device (a raw .img file) which will serve as a container for chrooting, and later converting to .vdi for use in VirtualBox. It's a fun project I'm working on: "Moving an existing Arch install to VirtualBox" (title in progress). Maybe I'll write a wiki article, since I did it three times already... And it works, even if I back them up while the system is running. I was just wondering what those files were.
    Oh, alright.  Cool.  Yeah, I just wanted to check whether there was any important differences between tar and rsync.  I think I'll check the wiki and do some reading about the two, but from the sound of it, it sounds more like a matter of preference than anything else, which is groovy.
    Last edited by lspci (2012-06-13 15:08:01)

  • Making material short text grade out while creating PR

    dear all
    while making pr for materials,by t-code me51n, the system does not make the material short text diable/grade out.
    eg if i select material from material master say material code 1000055-----& short text is --cement 53 grade.
    then at the time of creating pr i can change the short text cement 53 grade to any off my choice.
    logically this should not happend, as then their will not be any trace of PR in system.
    pls let me know how to come out of this problems.
    as we want that when ever we select the material from MM master, the system should make the short text grade out while creating the PR, so that further complication can be avoided.
    thanks in adv
    regards
    pairkshit

    hi manohar
    this process does not work. beacause with this process the system disable the entire coloumn of short text in ME51N.
    which is not our requirement.
    the system should only grade out the material short text cell while we create the PR for material, so that one could not able to change the material short text which has come from MM master
    is their any other solution for this.
    regards
    parikshit

Maybe you are looking for

  • Action links in OBIEE 11g

    Hi All, Can anyone help to understand all Action Links in obiee 11g. Thank You, Ram.

  • Archived log not applying

    archived logs are not apllying in DR SQL> select max(sequence#) from v$archived_log where applied='YES'; MAX(SEQUENCE#) SQL> SQL> select process,status,sequence# from v$managed_standby; PROCESS   STATUS        SEQUENCE# ARCH      CONNECTED           

  • Exporting from Premiere Pro CS5 and DVD authoring

    I have a reoccuring problem with Premiere Pro and authoring DVDs. This is how it goes. I shoot a video using a Canon 5D Mark III. 1080p 24. I then edit in Premiere Pro CS5, with proper settings on the sequence which are the preset Digital SLR > 1080p

  • PresenceDemo example error

    Hi, When I run the example from the ParlayXdevelper guide, I got error to visit the MyPresenceService.jsp page. This is the error message from OCMS console: 2007-08-09 15:14:10.232 WARNING OWS-03005 unable to connect to URL: http://127.0.0.1:8888/agg

  • When making a phone I can hear the other caller but they can't hear me

    No one can hear me when i make I phone call but I can hear them ??? I've tried the voice memo and that seems to work fine !!! Has Any one got any ideas that could help me please ???