Selection screen disappeared from CRM_UI

Hi All,
When I click on reporting link in CRM_UI, it is taking me directly to result of the report. No selection screen appears for pre-filter.
I executed particular report on Bex analyzer as well as on Java portal, its working fine there. I'm getting selection screen for per-filter in Bex analyzer and Java portal. I dont know why selection screen is not coming on CRM_UI.
Does anyone have any comment on this? Why this is happening only on CRM_UI?
Thanks and Regards,
Alok

Hello Vijay,
In general, please note that the Enterprise Portal URL is not supposed to be called in an <IFRAME> and it should be the top container in the browser, otherwise EPCM (Enterprise Portal Client Framework) will not work correctly.
Please check for SAP Note #1738027 - Embedding Enterprise Portal content in another webpage to see how it should be done correctly.
BR, Gilad B.

Similar Messages

  • When selecting playback from itunes library on Mac (purchased album from itunes!) i get random song played from that album and my selected song disappears from view. Nothing to do with shuffle.Mac OSX 10.6.8. Help, doing my nut in!!

    When selecting playback from itunes library on Mac (purchased album from itunes!) i get random song played from that album and my selected song disappears from view. Nothing to do with shuffle.Mac OSX 10.6.8. Help, doing my nut in!!

    What is your iTunes version?
    If iTunes 11, have you checked the "Up Next" list? If it is not empty, try if clearing "UP Next" will help:

  • Selected images disappearing from compiled CHM

    I've got a project that I'm trying to get compiled into a CHM file from RoboHTML 8. Everything seems to have gone fine, except that four of the images I added to the project prior to compilation don't show up in the CHM. They seem to be fine when viewed from RoboHelp, they're where they're supposed to be, and the source code of the compiled CHM refrences them correctly. And yet... they don't actually show up! I have tried renaming them, and reimporting them into the project, but these tricks didn't work. I'm hoping someone out there has some suggestions!

    I've had this happen a few times.
    I deleted the image from the topic and then inserted it again from the
    RoboHelp project files  (from the "Images in Project Folders" section on
    the left side - not from the open folder icon).
    This solved the problem for me; hope it helps you as well.
    Debbie
    Debbie Sarig | Documentation Manager | Magic Software Enterprises Ltd
    Tel.03-538-9386 | Fax. 03-538-9333
    Email. [email protected] | www.magicsoftware.com
    (Embedded image moved to file: pic19072.jpg)Magic Software Logo
    DISCLAIMER. Information in this message and its attachments may be
    privileged or confidential. It is for the exclusive use of the intended
    recipient(s). If you are not one of the intended recipients, you are hereby
    informed that any use, disclosure, distribution, and/or copying of this
    information is strictly prohibited. If you receive this message in error,
    please notify the sender immediately and delete all copies of this message.
    We recommend that you scan your incoming Emails. We cannot accept
    responsibility for any transmitted viruses.
                                                                                    From:       elemonated <[email protected]>                                                                               
    To:         Debbie Sarig <[email protected]>                                                                               
    Date:       06/17/2009 05:56 PM                                                                               
    Subject:    Selected images disappearing from compiled CHM                                                                               
    I've got a project that I'm trying to get compiled into a CHM file from
    RoboHTML 8. Everything seems to have gone fine, except that four of the
    images I added to the project prior to compilation don't show up in the
    CHM. They seem to be fine when viewed from RoboHelp, they're where they're
    supposed to be, and the source code of the compiled CHM refrences them
    correctly. And yet... they don't actually show up! I have tried renaming
    them, and reimporting them into the project, but these tricks didn't work.
    I'm hoping someone out there has some suggestions!

  • How to remove spaces at selection screen coming from logical database

    Hi Experties,
    When we hide some selection from the logical database.  The spaces still occupied and this make our selection screen looks awkward.
    How to remove the spaces left by hidden selection ?
    Regards
    Nislina

    Hi,
    I came across your un-answered question while searching for a solution on the similer problem. Though I couldn't fine a solution on SDN, but figured out one myself. Thought its a good idea to share it.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF screen-group4 = '003'.
          screen-active = 0.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
    Here screen-group4 contains the sequence number of the select-options field starting from 000 onwards.
    You may like to assign points and close the question.
    Kind Regards,
    Khalid Mustafa

  • Get selection screen parameters from sap query

    Hello. I use SAP Query Reporting, so I added a report assignment for detailing (sq01 ->  Change button -> Goto -> Report Assignment -> Insert row -> Other type row -> Abap Report Program)
    and put there ABAP program.
    When I run query and press CtrlShiftF1  (or double click) It calls my abap program.
    So the question is: how to get selection screen parameters in my program ?
    to be more precise I want to get date parameter (begda, endda)
    Thanks a lot.

    There is a Z query which I can see in sq01. I set reporting period and run the query; when I run it, it gives me the employee list.
    So I wrote the abap report to get an employee details, customized query as I mentioned above.
    The query calls my report and I need to get parameters.
    SELECTION-SCREEN BEGIN OF BLOCK frm1 WITH FRAME TITLE text-001.
    PARAMETER :  p_pernr LIKE p0001-pernr OBLIGATORY MATCHCODE OBJECT prem.
    PARAMETER : p_date LIKE sy-datum.
    SELECTION-SCREEN END OF BLOCK frm1.
    Parameter
    p_pernr
    passes normal. ALV Query contains it, but I'd like to get one more parameter from selection screen of the query and don't know how to get it.

  • Selection Screen Disappearing on error

    Hi
    I am new to ABAP.
    Below is the driver program for Smartform,
    after:
    Step-1 Entering data at selection screen
    Step-2 Pressing Execution Button
    An error is displaying 'Document no. not found' but the problem is, as soon as the error appears, selection screen goes blank, its not staying.
    Please suggest correction.
    With warm regards.
    Yogesh.
    *& Report  Z_MM_GPASS
    REPORT  Z_MM_GPASS.
    tables: MSEG,ADRC,T001W,MAKT .
    data: FM_NAME TYPE RS38L_FNAM.
    *& Selection Screen
    Selection-screen: begin of block b1 with frame title t1.
    Parameter:   Docno   like      MSEG-MBLNR ,
                 YEAR    like      MSEG-MJAHR .
    selection-screen: end of block b1.
    *& Comment on selection screen
    At selection-screen output .
    t1 = 'Selection-Screen' .
    *& Data validation at selection screen
    At selection-screen .
    select single * from MSEG where MBLNR = docno and MJAHR = YEAR .
    if sy-subrc <> 0.
    message 'Document no. not found' type 'E'.
    endif.
    CALL FUNCTION 'SSF_FUNCTION_MODULE_NAME'
      EXPORTING
        FORMNAME                 = 'Z_MM_PASS'
    *   VARIANT                  = ' '
    *   DIRECT_CALL              = ' '
    IMPORTING
       FM_NAME                  = FM_NAME
    EXCEPTIONS
       NO_FORM                  = 1
       NO_FUNCTION_MODULE       = 2
       OTHERS                   = 3
    IF SY-SUBRC <> 0.
    *  MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    *          WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    CALL FUNCTION FM_NAME
      EXPORTING
    *   ARCHIVE_INDEX              =
    *   ARCHIVE_INDEX_TAB          =
    *   ARCHIVE_PARAMETERS         =
    *   CONTROL_PARAMETERS         =
    *   MAIL_APPL_OBJ              =
    *   MAIL_RECIPIENT             =
    *   MAIL_SENDER                =
    *   OUTPUT_OPTIONS             =
    *   USER_SETTINGS              = 'X'
        DOCNO                      = DOCNO
        YEAR                       = YEAR
    * IMPORTING
    *   DOCUMENT_OUTPUT_INFO       =
    *   JOB_OUTPUT_INFO            =
    *   JOB_OUTPUT_OPTIONS         =
    * EXCEPTIONS
    *   FORMATTING_ERROR           = 1
    *   INTERNAL_ERROR             = 2
    *   SEND_ERROR                 = 3
    *   USER_CANCELED              = 4
    *   OTHERS                     = 5
    IF SY-SUBRC <> 0.
    *MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    *WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    Code Formattted by: Alvaro Tejada Galindo on Jan 7, 2009 2:30 PM

    *I have replaced
    if sy-subrc <> 0.
    message 'Document no. not found' type 'E'.
    endif.
    with
    IF sy-subrc 0.
    MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
    INTO mtext
    WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
    write:/1 mtext.
    ENDIF.
    *Program sintactically correct.
    *but still I'm facing the same problem, for your kind knowledge I don't know what is return code
    Edited by: Yogesh Pathak on Jan 7, 2009 9:45 AM
    Messege posted more than one time due to "SERVER ERROR" while posting., sorry for inconvenience.
    Code Formatted by: Alvaro Tejada Galindo on Jan 7, 2009 2:34 PM

  • Selection-screen (field from .Include structure)

    Hi all,
    I have a selection screen with several select-options. One of the select-option is
    select-options: s_vornr for afvc-vornr.
    Where 'vornr' is a .Include structure field in the table 'afvc'. Now my question is, in selection screen when I click on the box for this particular select-option I dont see the circle(from where we can select the existing input values) at the end of the box.
    Why is it so and how can get that circle option at the end of the box by sticking to the same table and field(afvc-vornr).
    Waiting for your help.
    Thanks

    hi,
    the field do not have nay value range with it.
    you can put the F4 help by using
    At Selection-Screen on Value-request <select-option>. event.
    e.g.
    DATA :  rt_values TYPE STANDARD TABLE OF type_values,
              rs_values TYPE type_values,
              rt_fields TYPE STANDARD TABLE OF type_fields,
              rs_fields TYPE type_fields.
      CLEAR    : rs_values,rs_fields.
      REFRESH  : rt_values,rt_fields.
    Creation of selection list
      rs_fields-tabname     = 'AFVC'.
      rs_fields-fieldname   = 'VORNR
      rs_fields-selectflag  = ' '.      
      APPEND rs_fields TO rt_fields.
       SELECT vornr form AFVC
                     INTO  TABLE t_vornr.
      SORT t_vornr.
      DELETE ADJACENT DUPLICATES FROM t_vornr.
      LOOP AT t_vornr INTO s_vornr.
        rs_values =  s_vornr-vornr.
        APPEND rs_values TO rt_values.
        CLEAR rs_values.
        ENDLOOP.
    FUNCTION 'HELP_VALUES_GET_WITH_TABLE'                   EXPORTING
          fieldname    = 'AFVC'
          tabname      = 'VORNR
          titel        = 'Counting
        IMPORTING
          select_value = <select-opion>
        TABLES
          fields       = rt_fields
          valuetab     = rt_values.
    amit
    Message was edited by: Amit Khare

  • How can I get selection screen values from outside of program?

    Hi. all.
    Now. I'm developing moritoring systems and I have problems. for getting selection screen values in runtime. Is there any function, methods or structure to know this?
    I'd like to get selection screen values while several programs working in runtime and update these values to table to show current system's status and input values for users in real time.
    For example.
    Now. 3 PGMs are working on systems.
    each PGM is ZAAA01, ZAAA02, ZAAA03.
    and ZAAA01 needs input parameter P01, ZAAA02 needs input parameter P02, ZAAA03 needs input parameter P03.
    In this case, I have to know values of P01, P02 and P03.
    The mornitoring systems will show current working status of PGMs(ZAAA01~03)' and these PGMs' input values.
    As fas as I know, the structure 'SCREEN' can be used in each PGM for runtime. Is there any SAP system structure or something else for this purpose?
    I hope your hopeful repsponse.
    Thanks.

    Umm..I need to explain more about this.
    of course I know  SET, GET PARAMETERS.
    But I'd like to minimize coding for each PGM level.
    I have over hundreds PGMs and I have to develop the PGM(including tables and structures) that mornitor
    all of those PGMs on a report in real-time.
    This PGM is kind of  Process Manager.
    First I should know dialogue job PGM and background job that pass parameters using SAP(ABAP) Memory.
    And then I have to update those PGMs' input values via screens into tables in real-time.
    So, I couldn't use SET,GET PARAMETERS for this PGM.
    I want to know methods that can be used for getting information about runtime PGMs' selection screen field values in SAP systems wide.
    Please help me some one knows this.

  • Selection-screen differ from developement to quality

    Hi All,
    I made one standard report as Z report.In this they used Logical databases.I made the changes in selection-screen by selecting some of the fields as invisible,and i created the request number for the report and i moved it to quality,But there the selection-screen it is displaying the fields which i made as invisible also.I dont want to display these fields.How can i do it. When i check the  screen attributes in developemnt and quality the language only differ.it is 'DE' in development and it is 'EN' in quality.I think this wont be the problem for screen it is displaying now.  Please help me to resolve this problem as soon as possible.
    With Regards,
    R.P.Sastry

    Hi Charlie,
    Thx for this valuable feedback.Just a small question.
    I am in LSMW screen in Developement and with the project/subproject/object entered
    What I understood is that I need to go to Extras>>Export project..Correct ?
    But will it export the entire thing i.e project/subproject/object in the file ? or I need to first goto LSMW workbench menu first then select All project objects which will show me the 3 nodes and then placing cursor on each node I have to export each one..
    I hope I have put up my doubt correctly..
    In short do I need to export/import each node i.e project/subproject/object separately or the action Extras>>Export will export entire thing ?/
    Regards,
    Manoj

  • IPad apps malfunctioning on screen, disappearing from screen

    Hi,
    I updated to iOS6 on my iPad 2 and when i tried to download all my of my earlier apps and moved them around they just disappeared leaving a black space between apps. I tried reseting but still the same problem. Please help.

    Hallo Jim,
    thank you for you answer.
    I mean a app like Quasar, that app is only available only on jailbroken iPads via the Cydia Store (more information found on the Blog http://blog.gsmarena.com/quasar-allows-you-to-run-ipad-apps-in-window-mode/). Because I don´t like jailbreak my iPad device, I´m looking for a apple conform app.
    Best regard,
    -- Gerald

  • Fetching data from a table & displaying it as checkbox in selection screen

    I have a database table which contains report name & report description as fields.based on the number of rows of data present in the table i have to display check box for each entry & the corresponding controls in the selection-screen.
    I got answers like:
    1.Declaring the checkboxes & hiding the same in runtime using user-command,which is not needed...
    2.Declaring the checkbox in screen painter using function code & calling the same,where i need a clear explanation...
    Is there any other method other than this plz let me know...
    Reply is most urgent...

    Hi Vijay...
    The selection screen should look like...
    cb1 -
    variant1 -
    icb1 -
    date1 -
    time1
    cb2 -
    variant2 -
    icb2 -
    date2 -
    time2
    where...
    cb1 - checkbox which indicates the first report(YRTEST) in the table...
    variant1 - textbox for variant which has a help,on clicking should display all the variants of YRTEST report...
    icb1 - checkbox which indicates the immediate background processing...
    date1 - date on which the job should be scheduled...
    time1 - time on which the job should be scheduled...
    If icb1 is clicked then date1 & time1 should not be allowed to enter & vice-versa...
    cb2 - checkbox which indicates the second report(YRTEST1) in the table...
    variant2 - textbox for variant which has a help,on clicking should display all the variants of YRTEST1 report...
    icb2 - checkbox which indicates the immediate background processing...
    date2 - date on which the job should be scheduled...
    time2 - time on which the job should be scheduled...
    If icb2 is clicked then date2 & time2 should not be allowed to enter & vice-versa...
    Its not like what u said...(Based on user entered data fetch the data of report(variant,date,time) and you can submit the data to background job as incase of single record by looping the data)
    Because we have only ReportName,ReportDescription as fields in the table & not variant,date,time...The variant,date,time are all entered in the selection-screen only from which the background job is scheduled...
    I hope the requirement is more clearer...

  • Transporting user defined selection screen from one server to another

    How to transport a user defined selection screen (0100) from one server to another.
    PBO and PAI modules written in PBO and PAI events for the selection screen are
    not transported.
    How to transport the modules in the events for the selection screen.

    Hi,
    Krishna, <b>All</b> the Objects(prms,classes,tables,stru...) will be transported thru Transport Objects only..
    Check Utilities->version->Version Mgt -> Here u will have the Transport number(if it's created under trnasportable obj).If you do not find TP no,then u would hav saved that as a Local Object.
    Then Relase the TP no from SE10 Trnx.
    Rgds,
    Jothi.P

  • How to call one report2 from report1 using report1 selection screen

    hi experts,
    iam presently working in report1.
    now, from my report1, i want to call report2 with report1 selection screen.
    how to call?
    thanks in advance.

    Below is an sample example, from where i am calling transaction MB5B (Report-RM07MLBD).
    Here i am using selection screen data from report ZTEST and passing it to RM07MLBD.
    REPORT  ZTEST
    DATA : listtab LIKE abaplist OCCURS 1.
    DATA : listtab_tmp LIKE abaplist OCCURS 1.
    DATA : N TYPE n.
    *DATA mseg_wa TYPE mseg.
    *SELECT-OPTIONS s_matnr for mseg_wa-matnr.
    *SELECT-OPTIONS S_WERKS for Mseg_wa-WERKS.
    PARAMETERS : S_MATNR LIKE MSEG-MATNR,
                 S_WERKS LIKE MSEG-WERKS,
                 S_CHARG LIKE MSEG-CHARG.
    DATA MKPF_WA TYPE MKPF.
    SELECT-OPTIONS S_BUDAT FOR MKPF_WA-BUDAT.
    REFRESH listtab.
    CALL FUNCTION 'LIST_FREE_MEMORY'
    TABLES
    listobject = listtab.
    SUBMIT RM07DOCS using SELECTION-SCREEN '1000'
    WITH matnr = S_MATNR
    WITH werks = S_WERKS
    WITH charg = S_CHARG
    WITH budat-low = S_BUDAT-low
    WITH budat-high = S_BUDAT-high EXPORTING LIST TO MEMORY AND RETURN .
    CALL FUNCTION 'LIST_FROM_MEMORY'
    TABLES
    listobject = listtab
    EXCEPTIONS
    not_found = 1
    OTHERS = 2.
    IF sy-subrc = 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    DESCRIBE TABLE listtab LINES n .
    CALL FUNCTION 'WRITE_LIST'
    EXPORTING
    write_only = 'X'
    TABLES
    listobject = listtab
    EXCEPTIONS
    empty_list = 1
    OTHERS = 2.
    IF sy-subrc = 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.

  • Go back selection-screen from level2 of cl_salv_hierseq_table

    Hi,
    Problem is to go back on selection screen in one go using BACK , CANCEL or EXIT button
    cl_salv_hierseq_table is being called to display output list.
    Same class cl_salv_hierseq_table is being used to display new list if user wants to see.
    All output list goes into ABAP stack.
    Neither a single standard button BACK , CANCEL or EXIT allow me to go back on selection-screen directly from 2 level onwards . it goes one by one level
    Copied GUI-status to use on_user_command and tried to use LEAVE TO TRANSACTION / CALL TRANSACTION but selection screen values in select-options / parameters not retrived
    How to back on selection-screen from level2 onwards and see all values which are entered initially
    Thanks
    ammonin

    Hi,
    No custom screen is created in my program for displaying result.
    Calling METHOD display of CL_SALV_HIERSEQ_TABLE ,
    So every time each DISPLAY method goes into stack .
    In degug , I found FM REUSE_ALV_HIERSEQ_LIST_DISPLAY is being called
    As per your suggestion it happens only when I am on first level of display result
    If I am calling same METHOD display for another output without distroying exsiting one. it stores in ABAP stack
    I do not know how to initializie existing / Kill CL_SALV_HIERSEQ_TABLE session before calling it again
    Standard button BACK/EXIT/CANCEL does
    SET SCREEN 0
    LEAVE SCREEN and goes back to only one level back not on directly on selection screen.
    If it is on first level then only selection-screen comes with values.
    Thanks
    Amy

  • Selection Screen from prog exec and transaction code is coming different

    Dear all,
    The selection screen is coming diffrent from the execution of the transaction S_ALR_87013558 and execution from the program name.
    The program name I found from SYSTEM->STATUS. But when I have checked in TSTC table for the program name for this transaction, it is showing blank in table.
    How can I make the selection screen same from both the executions ?
    Please help....
    Thanks & Regards
    Nrusingha Dash.

    Hi Nrusingha,
    Check with T.Code SE93.
    The transaction S_ALR_87013558 is calling another transaction START_REPORT.
    Just check with SE93 by giving the T.Code START_REPORT as input.
    see whether your program and this T.Code supported program is same or not.
    Regards,
    SB.

Maybe you are looking for

  • The iTunes application could not be opened. An unknown error occurred (-50)

    Today, I downloaded the latest version of Itunes. When it finished installing it came up with the following error: "iTunes was not installed correctly. Please reinstall iTunes. Error 7 (Windows error 127)". I have uninstalled iTunes, and all related

  • File adapter picking up files with wrong content

    Hello, We configured a file adapter to read *.xml files. We also defined the xsd for the files. We expected that the adapter would only pick up files that conform to the xsd. However we found that all *.xml files (even renamed jpeg's) are read. Is th

  • Brightness Issue in my Hp 15-R006TU Note book

    Hi, I have a problem with my screens brightness.Its My HP 15-R006TU notebook.I purchased my notebook on may 31 and it came with DOS OS.So i formatted it windows7 64 bit OS.But now i am having some display problem.When i am switching over any window m

  • Creating a Z output type

    Hai Friends, Please give me the full procedure to create an Z output type for billing. (For Example , ZGF2) in Development Server. Thanks

  • Recommended tool for recording screen, adding audio later

    I need to create a training video on my MAC (new MAC user). I used to use (gasp!) Flash to produce training videos, and that allowed me to add audio files separately. Like the rest of the world, our company is getting more and more MAC users, so I ne