Storage type indicators in Material master
Hi all,
I have created the list of Storage type indicator as follows,
<u><i><b>Storage type Indicator</b></i></u>
A01 A FIF
A01 E ARD
A01 E ATD
A01 E CGD
A01 E LGT
A01 E RSK
For stock removal storagetype indicator is only FIF
For Stock placement storagetype indicator is ARD,ATD,CGD,LGT,RSK
When i create a material in Material master ,for the WM view ,
the fields stock removal & stock placement having list of all the Storage type indicators.
AS per requirement ,The fields stock removal & stock placement (material master )should contain only the relevent storage type indicator.
Please suggest me how to do the same...?
Thanks & regards,
Dhanapal
Hello Dhanapal,
In material master you can maintain only one storage type indicator for putaway and one for removal, now based on this indicator you need to define the putaway storage type search stretagy so it will be optimized to find the storage bin.
For example,
As per the business requirement material ABCD must go to Storage type 001 and material BCDE must go to Storage type 002
so in above case,
Define storaget type indicator ARD and assign it to material ABCD, then in configuration you define putaway storage search as 001 with that ARD indicator.
In the same fashion you can define 002 for the another material.
Hope this helps.
Regards,
Arif Mansuri
Similar Messages
-
Storage type indicator in material master
For a combination of a particaular plant+WH no, a material can have ONLY ONE storage type indicator defined..is it correct?
What if I need multiple storage type indicator for a specific plant+WH combination.
Regards.>
Prajith KP wrote:
> For a combination of a particaular plant+WH no, a material can have ONLY ONE storage type indicator defined..is it correct?
>
> What if I need multiple storage type indicator for a specific plant+WH combination.
>
> Regards.
You can have multiple storage type indicators for a warehouse. However for a particular material, only one storage type indicator may be used for picking and putaway.
You would normally require storage type indicators for different search strategies. You may use an exit for the strategy.
Regards,
Aroop -
'Storage bin field in material master
Can we increase character length of 'Storage Bin' field in material master so that bin details can be accomodated ?
No you cant!
Takehelp of some other field.(text field)
Edited by: uttkarsh agrawal on Jan 30, 2009 3:11 PM -
Default Storage location from the Material master
Can we default the storage location from the material master into the reservation line item in trasaction MB21?
enter the production storage location in material master MRP2 view.
Edited by: Jürgen L. on May 7, 2008 6:52 PM -
Default inspection Type In the Material Master
Hello
We have to assign two -three inspection types in the material master. How to default this inspection types in the material master always .
Thanks
JJDear JJ
This you will have to do by putting validation in the material master. I dont think you have a standard solution for that.
Or esle you can run QA08 wherein you can assign inspection type enmass.
Please let meknow your feedback
Regards
Gajesh -
Please guide me how to include storage location to existing material master
Hi Guru's,
Please guide me how to include storage location to existing material master....
please provide step by step process or provide any documentation that would be helpfull to me...
please let me know of my question is not clear..
Thanks in advance and will give full points....
Srinivas...Hi
First :- You can define the storage loctions in the plant under the customization :- SPRO -> Enterprise Structure ->Definition -> Materials Management ->Maintain storage location
Once defined under the plant, you can create the same storage locations in the material master
Second :- Under SPRO -> MM -> Inventory -> palnt parameters, for your plant check the field " Create Storage locations Automatically" . This will lead to create new storage locations at the time of GR, even if you have not maintained under step 1.
Hope it answers your question.
Regards, -
Storage Condition field in Material Master Grayed Out.
Hi folks,
We are trying to use the Storage Condition field in a Material Master Plant Data/ Storage Location View. However I noticed the filed is grayed Out.
Then I looked at the Configuration in "Field Selection for Data Screen**" and the selection group 87 which is already selected as Optional which means it should let me pick the Storage Condition field.
**(SPRO->Log Gen->Mat Master->Filed Selection->Maintain Field Selection for Data Screen.)
Please note, I have already created Storage Conditions in SPRO. I am not trying to create new conditions now. I am just not able to pick one and enter it while creating or updating a Material Master.
your input is appreciated. Thanks in advance.where exactly you are looking at that you are so certain that is is optional?
In OMSR find your field selection group, then click the button on the right to the field selection group to see in which field reference it is used..
You can probably see many many field references.
There is e.g. a field reference for the transaction, at least for transaction MM03 your field selection should be display only.
there is a field reference for your material type,
there is a field reference for your industry (M, C etc ... the indicator you have to enter in MM01 initial screen)
there is a field reference for your material type,
Are all references (except MM03) are set to optional, or do you see references with display only among them? -
Copy of Storage bin while creating Material master
Hi,
When I am creating a material master by coping a existing Material Master (which has WM view and Storage bin maintained), system does not copy the same Storage bin to the material which is getting created
All the informations are copied except the Storage bin,
We need this for some business reason
Is this possibleHi,
We are creating the Material master copying exisiting material for Plant --> Warehouse --> Storage type -
Mass Storage Location Extention in Material Master
Hi,
Would like to how to do mass extention of material for storage location.
Regards,
Vengathi
use trannsaction code MMSC this willbe plant specific
or use MMSC_MASS
regards
kunal -
MRP Type field on Material Master Data
<DELETED>
Duplicate [thread|Message control by Material type;
This thread being locked.
Please do not post duplicate threads
-Paul
Moderator
Edited by: Paul Meehan on Jul 31, 2009 4:22 PMHi,
As per my knowledge, if you want to valuate your account assigned category "E" (Sales Order) order and you want to valuated this differently (other than make-to-stock) you can assign additional (valuation class i.e. EKLAS) in accounting view.
Hope this helps!
Reetesh -
"control data for storage type is missing"
Hi Guys
I am trying to create a goods receipt for an inbound delivery.
I created the inbound delivery VL31N - sucessfully
But when trying to create a putaway LT0F - error
control data for storage type is missing. msg no. L3006
Do i maiantain this control data for storage type in the Material master?
is there anything Im doing wrong?
Can someone help please.
Thanks in advance for the help.
Ahmad YahyaHi,
Check in SPRO > Logistics Execution > Warehouse Management > Master Data > Define storage type, here for your warehouse and storage type check stock placement and stcok removal control is configured.
Regards,
Prabu -
How to delete the material records related to storage type
Dear SAP guru's,
I got a situation that if the material "XXXXXX" exists in two different storage type (let say 001 & 002 ) and the material needs to be removed out of one (Let say 002) to avoid the picking and putaway in future.
Inorder to accomplish an above requirement we tried the below cases
Case 1: By flagged the material "XXXXXX" under storage type 002 in MM06 transaction.But it didn't restrict the system on allocating and removing the stock from /to to the storage type 002.
Case 2:After we flagged the material for deletion under storage type 002 ,we used to MM71 transaction to archive & delete the material record that assocaited with the storage type 002 completely.
I am kind of queiries to know if there is any other method or procedure available to delete the storage type associated material records in SAP.
Please guide me with the other options.Thanks.
Regards,
John.Hi John,
Its very simple, remove the Storage type indicators from the material master - Warehouse View 1 at Stock placement & Stock removal section, with this it won't pickup or place the materials in the concerned storage type.
If you have extended this materials to more than 1 storage type, you need to do the same for all the storage types.
Reward if it is helpful. -
Storage Location required entry in Material Master
Hi
My client requirement is, at the time of creation of Material Master, System will ask for Storage Location.Without Storage Location, Icann't create Material Master.
Even if I'll select Plant and Storage LOcation View & Warehouse View, System is not asking the storage Location.
Can anybody suggest me where I'll set the setting so that system will ask for Storage Location mandatory in Material Master.
Thanks & regards
PKBHi Raja,
Thanks for your reply.Before Posting the thread, I've already checked these Views what you told.But system is not asking me to enter storage location.
You can check in your system.
System only asking for plant not storage location.Even if we select warehouse view, system is not asking for Storage Location view.
Thanks & Regards
PKB -
How to un hide Industry type in material Master - mm01
Dear All Experts
Kindly help to unhide Industry Type field in Material Master .
Regards
AlokEdited by: Sridhar Jayavarapu on Aug 4, 2011 5:17 PM
-
Data for storage type search is not defined (E FC1 ) in WM module
Hi friends,
I m working in Ware house management.I have created material document and using the matertial document number in LT06.
I am getting the following error while creating transfer order for material document in T-code LT06.
Data for storage type search is not defined (E FC1 )
Message no. L3007
Diagnosis
Information on the storage type search has not been defined.
Procedure
Contact your system administrator. Note down the values that are within parentheses in the error message.
Please advise me how to solve this error.
Thanks in advance.
Regards,
WilliamSAP does not know where to put the material.
You usually enable SAP by defining storage type indicators, that you maintain at the putaway and picking indicator fields in material master.
then you setup the storage type search based on this indicators.
SAP can then know in which storage type it shall search for a space to store your material.
As a first step check whether you missed to enter this indicator in your matrial master WM view
Maybe you are looking for
-
Drill Down in Pie Chart not working in IE8 / Mozilla 5
Hi Experts, In my dashboards, drill down feature in Pie charts are not working if the flash is viewed in IE8 / Mozilla Firefox 5. In IE7 it is working. Is there any browser settings required for this ? Pls suggest. Drill down in column chart is worki
-
My Captivate 7 project includes two video demo slides with audio narration. The published mp4 video is vastly different from what it should be and how it shows in a preview in Captivate. I have tried publishing it again twice - once I changed the set
-
PC and Mac compatible email/print forms
I created an email/print from that I am running on my website. The email and print buttons work for my PC using customers but they do not work for my Mac using customers. How do I make the form compatible to both systems?
-
How can I allocate memory at runtime?
Hi, I have declared a an array of objects like. private SampeObject [] channelAccounts = null; How can I allocate the memory at runtime(dynamically) ? I tried with channelAccounts = new SObject(); But its giving runtime null pointer exception. Can an
-
Fetching resultset from SP - mssql
I am calling an SP from MSSQL database. The SP creates a temporary table and pushes data into that table. There is a select query on that temporary table at the end of the SP which retrieves records from that temporary table. The table gets deleted a