System identifica​tion miso models

Hi,
   I want to know is it possible to identify the MISO and MIMO models using system identification toolkit?
   I m using fieldpoint 2010. The program is running very slow inside the fieldpoint. so is it possible to divide the program in such a way that few compuations(which are less critical)  run inside the  computer and few inside the fieldpoint?
Regards,
Sai

Hi Ruser,
 LabVIEW System Identification toolkit provides SI Convert to Models of CDT VI to convert a model you created in the LabVIEW System Identification Toolkit into a transfer function, zero-pole-gain, or state-space model that you can use with the LabVIEW Control Design and Simulation Module.

Similar Messages

  • Nonlinear system identifica​tion using neural network (black box model)

     Hello, my thesis work is based on "suface EMG- angular acceleration modeling using different system identification techniques"......can anyone help me in doing nonlinear system identification using neural network...

    Well, look at that.  I actually had this problem before--and SOLVED it before!  [facepalm]  I'd forgotten all about it....
    https://bbs.archlinux.org/viewtopic.php?id=140151
    I just added "vmalloc=256" to my linux line, and X started right up!
    [edit] Well, mythtv had the solution, as well:  http://www.mythtv.org/wiki/Common_Probl … _too_small
    Last edited by wilberfan (2012-11-05 19:38:06)

  • System identifica​tion for open loop unstable plant?

    Hello,
    I have been trying to use system identification on labview. My problem is that my plant is open loop unstable and none of the tutorials or examples I have found seem to cover this so I cannot get it to work. Does anyone have any suggestions as to how I should go about it? My plant has an RC servo so it needs a PWM signal to stimulate it.
    Thanks
    Adam

    adamkse wrote:
    I want to control my plant with lead/lag control but I do not know the plant model which makes this very difficult. I cannot theoretically calculate it because the information I need to obtain a numerical transfer function or state space model is unavailable.
    I have it controlled with PID at the moment but this is not ideal.
    I am trying to use the system identification toolkit to obtain a transfer function but I do not know what to do because the examples do not work for open loop unstable plants.
    Adam
    Ok Open loop unstable functions cannot be predictably controlled (hence the terms; open loop and unstable,)  Not being able to model the actions is a bit of a problem too.
    Somehow, someway you need to get some kind of model or some kind of feedback to either provide stability in the plant or close the loop.
    Adding hardware (sensors) is the most likely solution.
    tell me more about the plant, I do this kind of thing for a living, so I could offer some ideas. 
    Jeff

  • System Identifica​tion Assistant Signal Generator

    Hello,
    I am using a GW Instek power source to heat a graphite rod within a vacuum chamber.  I am detecting the temperature with a K type thermocouple connected to a thermocouple input module.  I have written a labview program with a PID and have everything running, yet i force tuned the PID. I would like to use the signal identification tools labview provides to identify the transfer function and model the process.  I have used the system identification assitant in attempting to send a step signal and acquire a response, yet I have been running into difficulties.  The only way I can perform a step function is to manually generate an output of a specified power and then measure the response, as the signal generator within the system identification software is not identifying the GW Instek PSW 30-108 power source. With manual input and importing both input and output data i am able to get a parametric model, yet the transfer function provide me PID values which are 5 orders of magnitude greater then the ones i am currently using. Ideally i would like to use the software to generate the signal and measure the response continuously rather then using data i collect through my program.  If possible, I would also be interested in perhaps directly integrating VI's to perform signal analysis directly into my process program.
    Problems and what I have done:
    I have the drivers for the power source and my process program recognizes the device yet system ident assist cannot find the hardware. I have attempted to creat a task in NI-MAX yet the hardware is also non-identifiable. 
    Port module input works with VISA and this is how my VI is communicating with the power source.
    Goals:
    I would like to use the system ident assist to generate power ouput and collect temperature input, and generate a process model, so that I may tune my PID more accuratly.
    Also, I may be interested in integrating VI's directly into my process program, yet I am new to the LV language...
    I have attached  my Labview program below.  I would like to thank you in advance for your time and look forward to responses.
    Cheers
    Attachments:
    Test1_RT.vi ‏186 KB

    Double post, for further Information see http://forums.ni.com/t5/LabVIEW/System-Identificat​ion-Assistant-w-o-NI-Signal-Generator/m-p/3014731#​...

  • System identifica​tion error 41263

    hi...
    can somebody please explain why i am getting an error "41263-The System Identification Toolkit cannot retrieve the data in system model because the model type you wire in is incompatible with the system model requirements. " while using model simulation vi to simulate an arx model i created using estimate arx model vi?

    Hi ajaleelp,
    Sorry for the delayed response on this, but I have a few questions for you.  Are you just receiving this error at run-time? Meaning you have no broken wires or anything, but the VI stopsat the model simulation VI?
    Also, have you tried our example for model simulation? You can find it here:
    C\program files\national instruments\labview [version]\examples\System Identification\Getting
    Started\General.llb 
    This actually uses the estimate arx and model simulation VIs. So, you should be able to see if that works, and then compare it to your system.
    Hope this helps!
    Chris Van Horn
    Applications Engineer

  • RLS for system identifica​tion: problem in creating a signal + noise input.

    i have successfully implemented the RLS algorithm in labview, but i am having alot of trouble generating an input. at first i used a ptbypt sine input and wired it to my FIR Filter (win coeff ptbypt) and to my data queue (ptbypt) to generate U(n). When i plot the adjusted weights they give a perfect Sinc Function. 
    So, after this i add in a gaussian White noise VI (ptbypt) and add it's output with the output of the sine wave VI (ptbypt) and like before wire the output of the summation to the FIR Filter and the data queue point by point. The problem that is occurring is that my tap weights after becoming constant do not change. they are the same for when i enter the sine wave alone and when i enter the sine wave with the gaussina white noise, tap weights are same. they only change when i change the low cutoff of the FIR FIlter.
    its would be very much appreciated if someone may help me solve this problem i am having. I made the RLS (for system identification) as Final Year Engineering Project.

    the input is a sine wave , the sine wave passes through a system which incorporates a noise in it (we say the noise incorporated by the system is the Gaussian white noise) the corrupted input enters the system , the filter weights are adjusted by the algo, and a sine waveform is extracted filtering the noise.
    what kind of LTI system. Can you please elaborate? and i cant switch to LMS my project is RLS.

  • System identifica​tion for power converter

    Dear All,
                i am working on system identification  for the buck converter . for this i generated variable duty cycle with 20KHz switching frequency on analog output AO1 of usb 6221, now i want to introduce perturbation PRBS in steady state. now my problem is to add perturbation on analog output. please suggest me how to do this on analog output.
    thanks
    with regards
    gurpreet singh

    Do you want to mix some signal to your PWM signals? You can use normal add function to add your AO PWM signals with the PBRS perturbation signal.

  • Can i install mountain lion operating system in Macpro 2014 model.

    Hello,
    can i install mountain lion operating system in Macpro 2014 model?
    and currently operating system is mavrick.

    Yes, if you've a DVD of mountain lion you can install it else download it and you can make a DVD...
    If you want to downgrade or Install Mountain Lion, hold Command, Option (Alt) and R keys while your computer is starting up
    Then open Disk Utility
    choose Macintosh HD in the sidebar
    go to Erase tab and erase the drive.
    Done

  • Dv9500t system board identifica​tion

    I need to replace the system of my HP Pavillion dv9500 t laptop. the service manual provides two possible part numbers viz. one for a board "with 256MB of videp system memory for laptops with discrete video system memory" and a second where the 256MB is replaced by 128MB.  I have a 512MB Nvidia GeFore8600M GS graphics card. So, which one is right for my system the part number with "256MB" of video system memory" or the the one with "128MB".  System information tell me tha the board manufacturer is Quanta, system  ID is 30CB and version is 79.2E
    This question was solved.
    View Solution.

    neveo wrote:
    I need to replace the system of my HP Pavillion dv9500 t laptop. the service manual provides two possible part numbers viz. one for a board "with 256MB of videp system memory for laptops with discrete video system memory" and a second where the 256MB is replaced by 128MB.  I have a 512MB Nvidia GeFore8600M GS graphics card. So, which one is right for my system the part number with "256MB" of video system memory" or the the one with "128MB".  System information tell me tha the board manufacturer is Quanta, system  ID is 30CB and version is 79.2E
    You need the 8P PM Intel system board. It is the 
     (14) With 256 MB of video system memory for use with computer models
    with discrete video system memory HP p/n 447983-001
    Best regards,
    erico
    ****Please click on Accept As Solution if a suggestion solves your problem. It helps others facing the same problem to find a solution easily****
    2015 Microsoft MVP - Windows Experience Consumer

  • Changing Default logical system names of a model.

    Hi
        How could i change the
         Default logical system name for model instances:
         Default logical syatem name for RFC metadata:
        values for existing model? without recreating the model.
         Thanx

    Hi shah kond,
    you can change  rfc destinations of model in 2 differnet ways.
    firs one: right clcik on project
              from the context menu select propeties
              it will open a dialogbox from that select dynpro references then click on jco references tab
    by using add and remove buttons u can add and remove joc destnations
    2.expand ur model class double click output class.now seelct properties view.there u can change the jco destination
    hope this will use ful for u
    Regards
    Naidu

  • Ho to change the mapped System object to the Model to another System object

    Hi All,
    Initially i have created one system object (TestSystemForVC) for testing the VC application. Then i have started completing the whole development in that perticular model object. many data soruce objects are added to the model using the TestSystemForVC system object.
    Now i have created one more system object pointing to Otherclient. in R3. How make use of the same model pointing this new System object for working properly with out doing the complete development of that model.
    I just want to map the existing model to new system object. Can any body tell me how to achieve this.
    Regards
    Vijay

    Hi Vijay,
    therefore you can use the Alias Manager (see attachment). There you can replace all other system aliases.
    Best Regards,
    Marcel

  • Hi I bought a macbook in 2007/2008 and am wondering if it is possible to update the operating system? Here are my system details: Hardware Overview:    Model Name:     MacBook   Model Identifier:     MacBook4,1   Processor Name:     Intel Core 2 Duo   Pro

    Hi, I bought a Macbook in 2007/2008 and am wondering if it is possible to update my system so I can get the new version of iTunes?
    Here are my current system details: Mac OsX Version 10.5.8
    Hardware Overview:
      Model Name:    MacBook
      Model Identifier:    MacBook4,1
      Processor Name:    Intel Core 2 Duo
      Processor Speed:    2.4 GHz
      Number Of Processors:    1
      Total Number Of Cores:    2
      L2 Cache:    3 MB
      Memory:    2 GB
      Bus Speed:    800 MHz
      Boot ROM Version:    MB41.00C1.B00
      SMC Version (system):    1.31f1

    The model 4,1 can run a maximum of 10.7 Lion.  The 10.6 Snow Leopard DVD is in the Apple online store. You can get it for $19.99. After you’ve installed that then download the 10.6.8 combo updater to finish it off. http://support.apple.com/kb/DL1399 You will need to be running 10.6.8 to access the App Store to order Lion. http://store.apple.com/us/product/MC573/mac-os-x-106-snow-leopard
    System Requirements for 10.6:
    Mac computer with an Intel processor
    1GB of memory
    5GB of available disk space
    DVD drive for installation
      Some features require a compatible internet service provider: fees may apply.
    You can upgrade from 10.5 to 10.6 with no problems as long as you have at least 1gb of RAM. Any program that runs under 10.5 should run under10.6. See this list for third party programs compatibility with 10.6: http://snowleopard.wikidot.com/  You might have to upgrade some drivers for printers, etc.... And you will have to install Rosetta if you have any Power PC applications 
    http://www.macobserver.com/tmo/article/snow_leopard_installing_rosetta/  
    Once you are at 10.6.8 Lion is still available from Apple. You will have to call Apple Customer Care 1-800-692-7753 or 1-800-676-2775. to purchase it. Then within 3 days you will get an email with a code which you can use to download Lion from the App Store. Or go to http://store.apple.com/us/product/D6106Z/A/os-x-lion and purchase it there. The price is $19.99.
    Lion will require at least 2gb of RAM but really needs 4gb to run smoothly.
    As for third party programs see this list for compatibility with 10.7 http://roaringapps.com/apps:table
    Also Lion doesn't run any Power PC programs. To see if you have any Power PC programs go to the Apple in the upper left corner and select About This Mac, then click on More Info. When System Profiler comes up select Applications under Software. Then look under Kind to see if any of your applications are listed as Power PC. Universal and Intel will run under Lion.
    Before Mac switched to Intel processors in 2006 they used Power PC processors from 1994 to 2005. Power PC 601 through 604, G3, G4 and G5. Applications written for the Power PC processors need the application called Rosetta to run on Intel processors. This was part of the Operating System in 10.4 and 10.5 but was an optional install in 10.6. With 10.7 Lion Apple dropped all support for Power PC applications.

  • Problem with the printer or ink system code 0x610000f6 HP model 6700 premium

    Hello, I have recieved an alert for the second time in a week stating that there is a problem with the printer or ink system. The alert prompts me  to turn off, then on the printer. If problem persists, contact HP. 0x610000f6. What could be the cause for this type of alert to appear?

    '0x610000f6' error message appears if there is a 'Paper Jam' or a 'Carriage Jam' in the printer.
    You can experience following issues:
    The product won't print.
    The print job stops unexpectedly.
    To resolve Error code '0x610000f6' follow methods provided in below mentioned link
    http://h10025.www1.hp.com/ewfrf/wc/document?cc=us&lc=en&docname=c01620497

  • WIFI authentica​tion on Photosmart D110A with open system authentica​tion.

    I have moved and am using a new WIFI service. Since I moved, my Wi-Fi works on my Toshipa Laptop, but I am having trouble getting the WIFI to work from my ipad2 to my D110 airprint printer. The printer recognizes my WIFI address but doesnt seem to fully communicate to the network. I log on to my WIFI with a username and a password. My Diagnostic survey says that Authentication type is "Open System" with no encryptation. The printer setup does not ask for authentication during setup. Is there an authentication problem ? All diagnostics indicate that the wireless network is being recognized. Product name is Photosmart D110A.

    I have moved and am using a new WIFI service. Since I moved, my Wi-Fi works on my Toshipa Laptop, but I am having trouble getting the WIFI to work from my ipad2 to my D110 airprint printer. The printer recognizes my WIFI address but doesnt seem to fully communicate to the network. I log on to my WIFI with a username and a password. My Diagnostic survey says that Authentication type is "Open System" with no encryptation. The printer setup does not ask for authentication during setup. Is there an authentication problem ? All diagnostics indicate that the wireless network is being recognized. Product name is Photosmart D110A.

  • CPU identifica​tion number

    I have been unable to register a product key apparently because my touch smart doesn't have a CPU I.D. #

    Hello onfish,
    Welcome to the HP Forums, I hope you enjoy your experience! To help you get the most out of the HP Forums I would like to direct your attention to the HP Forums Guide First Time Here? Learn How to Post and More. 
    I understand that you are looking for the product and serial number to register your computer, and I would be happy to guide you towards a resolution!
    To find your product, model, and serial number for your desktop, please take a look at this YouTube video:
    In addition, you can also register your computer by following this link.
    I hope this helps!
    Have a great weekend!
    MechPilot
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the right to say “Thanks” for helping!

Maybe you are looking for

  • Hard drive died, but do i have a battery issue also?

    Hello, Well, my powerbook has been acting funny for the last few months and I think it finally died today. I've been doing weekly bootable backups on a smartdisk firelite 100GB external hard drive. Yesterday my computer was really slow, so today I up

  • PCI vs. PCI-X nomenclature

    I have read the past couple months of questions & answers re: PCI, PCI-X & PCI Express or "e" card topics and think I have one that hasn't been answered yet...kinda I would like to add a 3-port Firewire 400 card and a 3-port USB 2 card to my G5. My G

  • Idoc - to - JDBC mapping..

    Can any one help me on  step-by-step   Idoc to JDBC  mapping ..

  • How to extend an IDOC step by step

    <b>Howto extend an IDOC step by step</b> Hello, Waiting for become a blogger at sdn.sap.com, i post here a HOWTO for IDOC extension. 1) <b>/nWE31</b> Here will create the segments for extend our idocs. Example: 'ZDUMMY' -> Write a short description a

  • MediaEncoder producing incorrect bitrate H.264 files

    Hi, I'm using Adobe Media Encoder v6.0.1.21 (64 bit) to export a 93 minutes Sequence from Premiere. Since I want to hand this file out to a client on a Blu-ray disk, I used the "H.264 Blu-ray" format. In order for the file to fit on disk with the oth