Time pair generation

Hi Gurus,
I want to know, how the time pairs are generated. I have an idea that it considers vaules from PA2011 which are uploaded through PT80 and are written to TEVEN. I know operation FILLP is used to form pairs.I want to know which PCR does it ?
Really appreciate your help in this...
Regards,
Kumarpal Jain

TE30:
F1 help: The personnel calculation rule checks the status STAT1 for each time pair. This status has been set in pair formation and indicates whether it was possible to form an error-free time pair, or if the start or end time could not be delinited. If there are incomplete (open) pairs, TE30 issues an appropriate message. If the clock-out entry could not be delimited, it is completed automatically using times from the daily work schedule by means of operation

Similar Messages

  • Automatic Time Card Generation not generating Time Card

    Hi,
    I am running the program 'Automatic Time Card Generation'. The log file showing the message
    'The process did not generate any timecards for the Payroll, Payroll Period selected'.
    And there is no time card for the given Payroll month.
    Any suggestion for this.
    Many many thanks in advance.
    Regards,
    Subrat

    Please check metalink note 282547.1 to see it is relevant to your issue

  • Time pair on Planned working hours 0

    I want to generate time pair for days where planned working hours is 0.  how can i do that do i have to write a rule to generate time pairs on day with hours 8 (fixed if it is a off day) because if anybody takes PL on off day and CL on off day then i have to generate 8 hours of attendance during time evaluation.  By default system is not generating any time pairs and hence i am not able to generate 8 hours.  Plz guide.

    I can generate time types but the problem is that time type will be a generic time type and will be applicable to all absence classes with operation VARST or OUTTP.  Until I have a time pair on a non working day and if that time pair is generated then it can be read using RTIPA OR PTIPA variables. 
    Otherise for every absence type it will generate 8 hours but I want 8 hours to be generated wtih PL and CL only.  If i give LOP or LWP then also system is generating 8 hours time type which is wrong.  So until I generate a time type for the off day i cannot read 2001 or TIME PAIR TABLE. 
    Kindly guide.

  • Read start time of time pair and compare it in a PCR

    Hi All
    Created following PCR to check if th start time of the time pair is 09:30 or not. If it 0930 than I need to check the end time as well.
    000010            D HRS=PBEG  HRS?0900
    000020 *
    000030 =          D HRS=PEND  HRS?1730
    000040 = *
    000050 = =       HRS=DZ007 HRS-00.50 ADDDBZ007Z
    But the schema is processing only till line 20. As the start time of the time pair is 0930 it should go and check the end time.
    I would like to know if correct operations are used to capture the start time of time pair and compare?
    Any help will be much appreciated.
    Thanks

    Hello;
    Your pcr is wrong.
    000010 D HRS=PBEG HRS?0900
    000020 *
    000030 = D HRS=PEND HRS?1730
    000040 = *
    000050 = = HRS=DZ007 HRS-00.50 ADDDBZ007Z
    This is your rule. It checks whether it is 09:00 or not. If it is 09:00 it checks end time.
    000010 D HRS=PBEG HRS?09.50
    000020 *
    000030 = D HRS=PEND HRS?17.50
    000040 = *
    000050 = = HRS=DZ007 HRS-00.50 ADDDBZ007Z
    Beside you can not check it as 17.30 it should be out of 100.
    I mean 17:30 is 17.50 and 17:15 is 17.25
    Regards;
    Okan

  • TIP, TOP, Time Types, Time Balance and Time pair

    Hi Friends,
    This is Neehar.
    I am new to SAP HCM.
    Please can someone help me in explaining me about TIP, TOP, Time Types, Time Balance, Time Pair and Internal Tables.
    Please let me know, how Internal Table works and which values are stored in Internal tables.
    Please explain me with a Scenario.
    Thanks
    Neehar

    Hi Neehar,
    Please go through the below documents which will answer your questions.
    Time Types - The DNA of Time PCRs
    Function TIMTP
    Internal Tables in Time Evaluation - Personnel Time Management (PT) - SAP Library
    I hope this resolves your issue.
    Regards,
    Vivek

  • Generate Separate New Time Pair (not split)

    Hi All-
    US SAP_HCm 4.7
    I am trying to generate a separate time pair (in schema TM04) for overtime (M), while keeping the planned working time (S) time pair untouched. I am basically trying to make a copy of a time pair (i.e. hours) except for changing the processing type (S to M).
    Example:
    TIP Table - IN
    0800-1400 --- 8 hours -
    (S) Planned Working Time Pair
    Operation in Time
    Some Clever idea ... or concept
    TIP Table- OUT
    0800-1400 --- 8 hours -
    (S) Planned Working Time Pair
    0800-1400 --- 8 hours -
    (M) Overtime Time Pair
    I have tried using the operation GENTG in a PCR .. but it seems very limited. Is there any SAP Time gurus out there with a clever idea?
    Any help is much appreciated.
    Thanks
    B-

    I can generate time types but the problem is that time type will be a generic time type and will be applicable to all absence classes with operation VARST or OUTTP.  Until I have a time pair on a non working day and if that time pair is generated then it can be read using RTIPA OR PTIPA variables. 
    Otherise for every absence type it will generate 8 hours but I want 8 hours to be generated wtih PL and CL only.  If i give LOP or LWP then also system is generating 8 hours time type which is wrong.  So until I generate a time type for the off day i cannot read 2001 or TIME PAIR TABLE. 
    Kindly guide.

  • Where place set time pair P10 and P20 is one pair at IMG?

    hi
    now I have a question,
    DWS daily work time from 08:00-17:00 
    if one employee time events (IT2011)like this:
    07:51 P10 clock in
    07:52 P10 clock in (repeatedly)
    17:00 P20 clock out
    when the time evaluation ,the system (rule TE30) will give a error message,"missing clock out",
    because the system think P10 and P20 is one pair ,so at this case ,the system think  it missing one clock out.
    so I want to know where place set time pair P10 and P20 is one pair at IMG?
    thanks
    Olivia Yang

    Hi,
    So as per your requirement we need to have a seperate code for intime and outtime else u cannot differentiate it.
    And in time evaluation each clock in should have a clock out.Else the error by TE30.
    Can you please be clear in this question?
    so I want to know where place set time pair P10 and P20 is one pair at IMG?
    Thanks
    Swati

  • Time [ Quota Generation for Part-time employees]

    Hi Experts,
    I need a help.  I have a following issue.
    1] Whenever an employee is marked with a tick '' as Part-time], I want the quota to be generation based on the Weekly workdays [field in SAP WKWDY].
    2]  I used the option of defining reduction rule by selection the radio button on the following option:
                Weekly workdays
                Day by day in accrual period
                Accrual period
                No reduction [defined in To Percentage and From percentage]
    3]  When I execute the PT60, get an error message as "No Standard working time for key 13 5 20100501"  I am running it for the month of May2010.
    Can anyone throw some light, in case I missing something.  I have earlier done configuration of Reduction Rule by using the rule 01 which has the option of Employment Pct. from Plnd Working Time Infotype. and then maintain for the employee the tick on Part-time and reduce the employment percentage.
    Now the client I am working wants it based on the Weekly Work Days and these are all Salaried employees.
    If anyone has faced this problem and has as solution, can you please share.
    Thanks in advance.
    Regards,
    Edociana

    Hi Kathy,
    Yes, i have found the solution to it. I do not know whether it will fit into your situation or not, but i got two solutions for my issue mentioned above, please check it may help:
    1) To use capacity utilization field in IT0008 to get the FTE hours and defining the reduction rule of absence quota based on the capacity utilazation percentage.
    2) There are three user exits available in the standard report RPTQTA00, i have used one of them to write my own rules for the calculations (deduction rule)
    Do let me know if i can help you in any respect. Thanks.
    Regards,
    Sujit

  • New iPod touch. Error message when trying to sync to iTunes first time: "Pairing record missing. Can't sync." Nothing in Support addresses this. Help!

    I havev a new iPod touch 4th gen. When trying to sync to iTunes first time, I got this error msg: "Pairing record missing. Can't sync." Nothing in Support addresses this. Help!

    See if the previous discussions with the same error will help you. Some of those are listed on the right side of this page under the heading "More Like This".

  • PKCS#11 provider - ECDSA key pair generation on token

    Hello,
    I want to generate ECDSA key pair on HSM (nCipher's netHSM) using SunPKCS11 provider and Java 6.
    After generation for all supported curve names (e.g. secp256r1) I try to call getEncoding method from PublicKey object (keyPair.getPublic().getEncoded()) and
    I get RuntimeException
    caused by java.io.IOException: "Point does not match field size"
    at sun.security.ec.ECParameters.decodePoint(ECParameters.java:75)
    at sun.security.pkcs11.P11ECKeyFactory.decodePoint(P11ECKeyFactory.java:61)
    at sun.security.pkcs11.P11Key$P11ECPublicKey.fetchValues(P11Key.java:1002)
    Keys are accessible on HSM.
    Everything is well configured and works fine with RSA keys.
    Using IAIK PKCS#11 provider I got proper values. Is it any bug in SunPKCS11 provider?
    Regards,
    MarcinP

    I recently had a problem with ECDSA and the PKCS#11 library of nCipher. Here's info from one of their engineers about the PKCS11 library:
    "There are two separate issues - one is that our current pkcs11
    release doesn't support ECDSA signature with SHA-2 hashes
    (the v11.00 firmware adds support for it, but the main release version of
    the pkcs11 library hasn't been updated to take advantage of it yet).
    There is a hotfix version that does support SHA-2 hashes with some
    restrictions, talk to [email protected] for details, and V11.10
    should be out soon and have that merged in.
    But the issue with setting CKA_SIGN is that our underlying HSM API
    allows elliptic curve keys to be either key exchange (ECDH) or
    signature (ECDSA) keys, but not both at one.
    At the PKCS #11 level, if you specify CKA_DERIVE=true and let
    CKA_SIGN default, it will default to false, and vice versa.
    If you specify both CKA_DERIVE=true and CKA_SIGN=true, then we
    return CKR_TEMPLATE_INCONSISTENT because we can't do both with
    the same key. (However, the tests using C_GetMechanismInfo will
    show that we can do both mechanisms, because we can - so long
    as you use different keys, even though they have the same PKCS#11
    type.)
    I can't comment on when or how that will be changed."
    I was using the PKCS#11 library through NSS when I ran into the problem, but I imagine Java would run into similar problems also using the PKCS#11 library. I was able to generate keypairs but not create a CSR (which required making a signature, which required SHA-2).
    Can you just use the java classes to speak to the netHSM? I've never directly written code to do so myself, but I have used Corestreet's OCSP product that uses the java classes to speak to the nCipher HSMs (though not using EC). It might work better than going through the PKCS#11 layer. There should be a java directory under NFAST_HOME that contains some jars.
    Please post back if you figure anything out as I'll probably be playing with this stuff myself soon.
    Dave

  • Middleware- Taking long time for generation of Runtime objects- SMOGTOTAL

    Hi Experts,
    I am doing middleware settings for connecting CRM 2007 with R/3 4.7.
    When i am generating all the required objects ( Replication objects, publications....) using the transaction code SMOGTOTAL, system is taking very long time for generating the objects. Generally it takes 4 to 6 hours but in our case it has already took more than 36 hours and still its running.
    Can anybody tell me what i need to do to make the generation process faster.
    Regards
    Nadh

    What I read in the best practice:
    It is not required for a new installation.
    Typically this activity has already been executed during the system installation or upgrade.
    Use transaction SMOGLASTLOG  to check if an initial generation has already been executed. In this case you can skip this activity.
    I checked transaction SMOGLASTLOG, and in our case the initial generation was not yet executed. I also couldn't continue with the next steps.
    That's why I started up the job, it is finally finished after 104 hours..
    Thanks for your fast reply.
    Jasper.

  • Time table generation of computer science department

    hi,
    i santanu need help of the people of this forum on developing the project on generation of computer science department .
    input- the number of teacher,no of class rooms,no of classes rae specified
    output-- the time table is generated witha the help of program
    i got a largr project which is combination of 5 to 6 individual project.so please help me in solving this program.if any one got the code for it or any help will always be appreciated.
    thank you.
    santanu

    Don't crosspost please!
    http://forum.java.sun.com/thread.jspa?threadID=5148535
    http://forum.java.sun.com/thread.jspa?threadID=5148533
    http://forum.java.sun.com/thread.jspa?threadID=5148532
    For ideas, look at this thread:
    http://forum.java.sun.com/thread.jspa?threadID=636835

  • Time stream generation report issue - ZZTSTRREGENERATE

    Hi,
    As per note 1421812 - Report to automatically generate all time streams, we have generated report ZZTSTRREGENERATE for auto generation of time streams.
    But when the report is executed time streams are not getting generated. Rather we get the message ' Timestream (XXXX) not generated for year 2016, Timestream (XXXX) not generated for year 2017'.
    I have checked the associated calendar in the Time stream ID and it has validity till 2020. Not sure why this is happening.
    Has someone faced this ? Any pointers will be of help.
    Thanks in advance.
    Durai

    HI Durai,
    Please refer to this thread:
    800:APO Time stream (TS XXXXX) not generated for the year 2 015
    Kind Regards,
    Mariano

  • Time automatic generation

    Dear Experts,
    i want to know if it possible to make automatic generation of penality for employee who didn't clock OUt/IN
    example :
    while running the time evaluation if the system found that the employee doesn't have clock in , then automatically pass it and calculate this day as absence day without entering absence day in infotype 2006
    Please i need quick answer ASAP.

    while running the time evaluation if the system found that the employee doesn't have clock in , then automatically pass it and calculate this day as absence day without entering absence day in infotype 2006 i think it is 2001
    Hi
    Kathy before going to the issue please check this
    When employee misses out the puch you want it to be an undpaid absence and do not want the absence day in IT2001  (i think this is incorrect since to track no of miss out we need it and also in order to sort out absences unpaid is due to Miss outs of punch in or due to leave for Un authorised we need the records)
    When ever employee misses out the punch  we cannot directly assume that it is absence since there might be problem in puching system in that case wht is the plan of action from SAP and does we intimate the employee that he missed out the punch in etc
    In standrad this is not best procedure as the system throughs error in PCR TE20

  • Time Pair formation - Query

    Hi Sap Experts,
    I am just trying to understand the Time formation query from the table TPT_PAIRSTAT2, V_T705B
    i have one clock in and two clock out in IT2011, when time evaluation runs , TIP entry comes like this
    so the 14.000 will be clock in and 18 and 22.34 are the Clock out,, but i want pair formation to come like this.
    14.0000 to 18.3389
    18.3389 to 22.3406,
    is this possible?
    Thanks
    Sriram

    As mentioned by Vivek Barnwal, It is bit difficult achieve through PCR as well, Since your Clock in is 14:00 clock out is 18:3389 i.e next pair is not having clock in but you wanted to create a P10 which is 18:34 or etc (next after P20) Explore TPT_PAIRSTAT2 you may find any option else need to check with some other alternative  custom developments or enhancements.
    Since PCR does not work with constant's in this case,it varies with each individual we have to write a logic in such a way TIP should get update with previous P20+ 1 minute or etc.
    Regards
    Venkatesh

Maybe you are looking for

  • Error in BIOS v2.0

    In BIOS; If you select "Set Supervisor Password" option, look at help text @ screen botton.. Also select "Set User Password" option, and look at help text. "Set supervisor password" shows "Specifies user password" -in help text- "Set user password" s

  • Group Account Configuration - OBIA 11.1.1.7.1

    Hello, I am setting up Financial Analytics OBIA 11.1.1.7.1, have following questions regarding group account code setup 1. Should we always use Natural Account Segment for mapping to Group Account Codes? I could see a customer is using different segm

  • CS6 Toolbars & Menu Too Small

    I have just got a new laptop with Windows 8.1 and a 3200x1800 screen resolution. When I installed CS6, all the toolbars and menus are too small to even use. I have looked through these forums and, surprisingly, it seems like a common issue that has b

  • In your guys' opinions, which is better? iPhone 5c or iPhone 5s?

    In your guys' opinions, which is better? iPhone 5c or iPhone 5s?

  • IE vs Firefox - Popup rendering bug

    I have a Flex app that uses the PopupManager class to display various objects as popups. When I run the app in IE the popups display just fine. However, running it in Firefox causes the popups not to render fully. I have Flash Player 9 installed on b