User quota update bug on Iomega StorCenter ix4-200d - 2.1.42.189​67

Hi everyone,
my device is Iomega StorCenter ix4-200d running firmware version 2.1.42.18967
Last week user X on my device exceeded his personal folder's default quota (2 GB): I told him to move exceeding data away from the storage device and he did so.
Now he only has 300 MB under his folder, but the the device's web interface is still complaining about userX using 50 GB of space and therefore exceeding his quota. Furthermore, user X is not allowed to put more data into his personal folder, even if only stores 300 MB of data...
I tried the following solutions:
reboot the device
disabled quota on user X's personal folder and then re-enable it again
but none worked. How can I fix the issue?
Any help/hint would be appreciated. Thanks in advance

Hello sanzso
I highly recommend you contact LenovoEMC PX12 support in your region regarding this issue. 
a quick suggestions though.  If media server is enabled, in some situations there can be an issue causing a data usage mis-match.  Usually this would only show the  "others" listing to show as having a strange usage level.
To correct this, media server would need to be turned off, copy the share data to a new share or external storage device, delete the existing share(s) then restore the data to the new share(s).
LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
US and Canada: https://lenovo-na-en.custhelp.com/
Latin America and Mexico: https://lenovo-la-es.custhelp.com/
EU: https://lenovo-eu-en.custhelp.com/
India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
http://support.lenovoemc.com/

Similar Messages

  • Iomega StorCenter ix4-200d iSCSI performance

    Hi there, just looking for some help here, we have an Iomega StorCenter ix4-200d device that was not in use and I tried to make a drive for storing media files and moving them from the file server. I have created an iSCSI disk and connected to a Windows 2008R2 using an iSCSI Initiator, the Iomega box comes with two network interfaces that were previously bonded, the connection was quick and easy to setup, the problem that I am having is performance. When transferring small file/s the transfer is quick and effective, but if the file/s pass more than 1GB windows explorer crashes and the OS get frozen, I have been monitoring the disk use and is horribly high when transferring those files, taking more than 10min for a 1.5GB to transfer, the LAN is 1GB speed. I read about creating specific VLANS only for iSCSI transfers, but we did not have that before and the drive was previously used as iSCSI backup solution, before another solution now in place replaced it Any help or thoughts are more than welcome Juan

    GUS_Lenovo, Really helpful your coment, please can someone else let us know if it is having this problem. The setup is very simple a VMware ESXi 5.5 virtual machine, OS 2008R2, connected using passtrough native windows iSCSI initiator to an external Iomega StorCenter ix4-200d drive. I disconnected the target from the troubled server and connected the iSCSI disk to a test server, same setup VMware 2008R2 connected to the pysical iSCSI uing the windows native initiator, no roles on it. I double checked that only the test server was connected into it, same symptom, transfers files up to 500MB are quick and effective, if the file/s to transfer pass 1GB or more the transfer halts and the explorer process on the VM crashes, not very effective for now. Bandwith?? any help very much appreciated

  • Iomega StorCenter ix4-200d replace all disks

    REPLACED DISKS: 4 Hard Drive SEAGATE 1 TB with code ST31000520AS.
    Before the replacement, had carried out the firmware upgrade for CC38 as executable: DriveFWUpdater-1.8.exe
    Successfully finalized.
    After the replacement of 4 discs, the procedure would make a boot by USB to reinstall the OS, right?
    But when holding the reset for more than 60 seconds, does not appear on the LCD panel USB image >> Network, does not find the boot from USB.
    Is there any other procedure?
    Thanks.
    Solved!
    Go to Solution.

    Hello estaile
    The "DriveFWUpdater-1.8.exe" utility is just for updating the Seagate firmware to cc38 in the ix4-200d / ix4-200d CE.
    to replace all the disks you would need to follow the disk upgrade guide here.  Basically if you still have at least one original disk with the Lifeline OS firmware, then you can boot the unit with that disk and 1-3 blank disks, after booting the unit will copy the firmware over.  if the web interface requests overwrite,  allow the overwrite.  after that has finished you can power down, install the 4th disk and boot up the unit.  the previously installed disk(s) would then be able to copy the firmware over to the last disk.
    If you do not have any original disks with the firmware intact, it will limit your options as some of the legacy firmware imagers are no longer available.  I recommend contacting LenovoEMC support in your region at that point to see what options might be available.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Replacement drive for IOMEGA StorCenter ix4-200d

    Hi
    One of my four Seagate ST32000542AS 2TB drives in my NAS needs to be replaced, but it seems that that drive has been discontinued.
    Which compatible drive should I choose instead?
    Soren

    It looks like the ST2000VN000 is 5900 RPM, which would work. You could also try ST2000DL003, ST2000VM003, ST2000VX002, or ST2000DL001.
    Have questions and need answers?
    Search the database for answers to FAQ's, software/driver downloads, tutorials, news, features and more!
    LenovoEMC Support & Downloads
    LenovoEMC North America Support Contact Page

  • Iomega Storcenter ix4-300d stuck at 95% after firmware upgrade

    Hi,
    I upgraded my device after I got an email that there is a new firmware:
    An update to version 3.2.10.30101 of the Iomega StorCenter ix4-200d software is now available
    I installed the update but now it is stuck at 95% after rebooting.
    Never had any problem before the firmware upgrade. 
    Any advice?

    Hello BelgianTomas
    I recommend that you first power down the unit if the unit has not completed the boot process.  Then re-seat all disks and try booting the unit again.  Please do not try to access the web interface until the power led is solid white.
    Next would be to try moving the internal disks to different bays to see if a different drive order wil allow the unit to boot. 
    If that does not help, LenovoEMC suppor should be contacted for more advanced options.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Ix4-200d CE locking up on device restart after FW update to 3.2.10.30101

    I updated the firmware on my iOmega StorCenter ix4-200d CE (4TB) to 3.2.10.30101 last night from 3.2.8.30031. After it uploaded to my NAS, it started to do it's normal shutdown, followed by the power up. Everything was going well until the power up, where it has locked up at 95%. There were no messages at all that came up either via the web interface, or on the LCD screen on the front of the device itself. 
    Has anyone else run in to this problem? Does anyone know of a solution? I have powered it off twice, and turned it back on. I get the same results. 
    Can I maybe load the previous version of the firmware on to a USB key, and install that without using the web interface, or losing any data? 
    EDIT: I should add, that it does show up as connected to my network when I look at the connected devices on my router. Upon seeing that, I decided to see if I could access the drives over my network, and oddly I can. I can access them both from my MacBoook Pro running Mavericks, as well as my PS3 which I use to access the Media Server on my NAS. My TimeMachine back ups are also still going to the NAS, and I can copy files too, and from it. 
    So it appears it has fully restarted, but the  device itself on it's LCD screen, the web GUI, and the LenovaEMC Storage Manager keep saying that it is still "restarting", not allowing me to do any managment of the device. 

    Hello SurveyGeek
    If your device did not seem to complete like others did on this forum thread, please try the following.
    - Backup any critical data from the unit if another copy does not already exist. 
    - Power down the unit swap the first and last hard drives so they are in opposite bays and also re-seat the remaining disks.
    - Reconnect power cable and allow unit to boot.  you should close all previous web sessions to help speed up the boot process.
    - If the issue persists please contact LenovoEMC support to review the issue further. 
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Iomega ix4-200d Four drives in RAID 5 Lost Data

    Hi,
    I've Iomega StorCenter ix4-200d with firmware version 2.1.46.30093. The unit has four 1TB drives setup as RAID 5.
    I've been having intermittent issues with drive 4 and IOmega device has been automatically reconstructing the protection in last few weeks. Recently drive 1 showed similar issue and now the whole data became invisible.
    After Login to the device I see this message:
    4 new drives with existing data have been added to your Iomega StorCenter device.
    The Iomega StorCenter device failed and some data loss may have occurred.
    On the Disks page, I see the four disk and If I hover over one of the disk it display this pop help message:
    Disk has been replaced with a disk containing data from another system.
    On one of the page I got this message:
    Disk Overwite Authorization:
    A disk with existing data has been inserted.
    Note that using this disk will permanently destroy all of its previous contents.
    Check this box to authorize overwriting the disk.
    I have not done the overwriting to avoid any data loss. The unit is out of warranty and I need data recovery.
    So far I've found these options online. Just would like to know the your experience, data recovery success and $$ amount you paid for the tool / service for recovery.
    a. http://www.diydatarecovery.nl/irecover.htm - $70 tool
    b. http://freedatarecovery.us/ - Service
    c. http://www.angeldatarecovery.com/raid5-data-recove​ry/ - Service
    d. http://www.krollontrack.com/data-recovery/recovery​-software/windows/ - $499 tool
    e. http://www.freeraidrecovery.com/library/raid5-reco​very.aspx - Free tool
    f. https://www.runtime.org/raid.htm - $99 Tool
    g. http://www.retrodata.co.uk/data-recovery-services/​nas-data-recovery/iomega-data-recovery/ - Service
    h. http://www.drivesaversdatarecovery.com/devices-sup​ported/raid-data-recovery/ - Service
    Please advice.

     Hello svfm
    As mentioned in another thread, UFS Explorer has been fairly successful, however I have not seen quite as much results from other applications.   iRecover would be the next recommended option other than contacting a data recovery provider that can work with RAID systems.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Problems with user-defined update-process

    Hi.
    I have a small problem in the right syntax in an user-defined updated process.
    The process is called by a button on the page and should update a record in a table.
    BEGIN
    UPDATE wam_mod_allocation SET
    alloc_assessment = V('P2120_ASSESSMENT'),
    last_update_date = LOCALTIMESTAMP,
    last_update_staff = V('APP_USER')
    WHERE username = V('P2120_USERNAME')
    AND module_id = V('P2120_MODULE_ID')
    END;
    This is the code of the process. The line with the problem is marked bold. P2120_USERNAME is a text field in the page and contains the username to be updated.
    The problem is, that the comparison doesn't work. the value "smith" is available in the table and is the same as in the text field. (both in lower case).
    If I replace the part V('P2120_USERNAME') with 'smith' (with single quotes), the update statement works properly.
    How do I have to compare the username with the item value that it works properly?

    1. Stephan
    2 + 3 Well. I enclosed both tags in the TRIM-Operator and it works. First, I thought, a whitespace caused the problems. To determine which value contains the whitespaces I removed the trim-tags on both sides. It works.
    It is quite funny, because,if I remove both tags, it works too? Well. Yesterday it didnt.
    To be on the safe side, I will include the trim-tags.
    Thanks very much.
    Stephan

  • Iomega StorCenter ix2-200 device fails when powered. Best way to retrieve data

    Hi, I'm new here because until now I've been lucky enough to experience no issues with my NAS.
    Unfortunately, as of this morning when I power on the ix2 the '!' light blinks red. I can't connect to it through my computer and the desktop Iomega program, under 'dashboard' everything seems as usual except the pie chart showing space usage is not there. But it does still say the device is operating normally. However, when I click on Users or Shared Storage it says 'Disks Not Ready. The selected function is not available due to the state of the disks. Visit the dashboard for details.'
    Can anyone advise me what to do from here? I keep a backup elsewhere but I would like to get a few little things of that have been added since my last backup if possible though, it's not the end of the world if it's not.
    Many thanks, James.

    Can you create new shares? Some users have been able to retrieve their data by adding the shares back by the same name. Not sure if it will be the same case here. A Linux-based device should be able to read from the drives, so there may be an error on the drive or a bad sector possibly. You may need to use a data recovery service to retrieve the data.
    You could try one other thing by accessing the hidden support page.
    Follow the instructions here: http://www.vmcutlip.com/index.php/2013/04/howto-enable-ssh-root-level-access-on-an-iomega-storcenter...
    Select "Recover Disks". I would only do this as a last resort and are not concerned with losing the data.
    Have questions and need answers?
    Search the database for answers to FAQ's, software/driver downloads, tutorials, news, features and more!
    LenovoEMC Support & Downloads
    LenovoEMC North America Support Contact Page

  • Iomega Storcenter The operation couldn't be completed. (OSStatus error 2.)

    Hi - I sure hope someone is able to help?
    I have just purchased an Iomega Storcenter IX2-200 4TB NAS device.
    I have tried to use it as a TimeMachine device but when I select the TimeMachine disk from the preferences panel I receive the error 'The operation couldn’t be completed. (OSStatus error 2.)'
    I have not created any users etc, the device is as it came out of the box. The TimeMachine disk automatically appeared in the Finder when I connected the IX2
    Is there a 'special' userid/pw I should be using for the TimeMachine? When prompted for those details from the TM preferences I use admin/<password> and receive the above error - any other entry results in a message stating that the userid/password info is incorrect.
    I don't want to return it because I see it as a useful device to back up my three Macs.
    If anyone is able to help they will be my friend for life!!
    Kind regards,
    Dave.

    I have an idea this is going to take some working out.
    What IP is the upstairs TC and what IP is the downstairs one?
    Can you ping them both please by name and by IP address?
    Can you manually mount the share you will use for time machine in the iMac upstairs..
    In finder go, connect to server.
    Type in the name AFP://user@TCname
    You will then be asked for the password and it should be able to be stored in the keychain. Then select that for TM.. if TM still carries on, reset it and try again. See A4 here.
    http://pondini.org/TM/Troubleshooting.html
    The double entry and refusing to join the right disk is a Mountain Lion trait.

  • Address of the user changed updated into sap but still not reflecting at

    address of the user changed updated into sap but still srm shopping has the old
    address .
    what could be the possible reasons of this bug?

    Hi
    Which SRM version are you using ? <b>We encountered the Same Issue long time back -></b>
    Are you updating the Addresses in Web Transaction or using SAP GUI (SU01 transaction) ?
    <b><u>Please go through the following SAP OSS Notes below, which will definitely help -></u></b>
    Note 930371 - SRM 5.0: BBPUM01 Check Data
    <u>Related Notes</u>
    Note 931556 - SRM 5.0: Hiding the BBPUM01/BBPUM02 button
    Note 923461 - SRM 5.0: BBPUM01 description for position
    Note 885954 - SRM-UME: User synchronization with wrong address data
    Note 884067 - BPartner w/o an private address can't change their settings
    <u>Do let me know.</u>
    Regards
    - Atul

  • Increase Individual Users Quota

    In the past I was able to right click on a Users Home Directory > Properties > Novell Info and change their Quota.
    Now when I do this, even though it says the change was made, it is not updating for the Users. They still cannot save to their Home Directory as it tells them their disk is full.
    There is ample room on the Volume.
    NSM does not report any errors on the Engine or Agent monitor screens.
    NSM 2.5.1 (I know. An upgrade is on our list :)) On Netware 6.5
    Windows 7 User machines
    eDir 8.8.6
    NSS data on OES2 SP3
    Any ideas. This is probably the first request we have had for a quota increase since we went to Windows 7. Could that be the issue?
    Thanks!!

    On 9/10/2012 1:06 PM, kbannister wrote:
    >
    > In the past I was able to right click on a Users Home Directory >
    > Properties > Novell Info and change their Quota.
    >
    > Now when I do this, even though it says the change was made, it is not
    > updating for the Users. They still cannot save to their Home Directory
    > as it tells them their disk is full.
    >
    > There is ample room on the Volume.
    >
    > NSM does not report any errors on the Engine or Agent monitor screens.
    >
    > NSM 2.5.1 (I know. An upgrade is on our list :)) On Netware 6.5
    > Windows 7 User machines
    > eDir 8.8.6
    > NSS data on OES2 SP3
    >
    > Any ideas. This is probably the first request we have had for a quota
    > increase since we went to Windows 7. Could that be the issue?
    >
    > Thanks!!
    >
    >
    kbannister,
    Are you able to increase these users' quota through NSM's Quota
    Management interface? Or through iManager? Or have you only attempted
    this through ConsoleOne?
    If none of those tools work, the problem might be the NSS settings on
    the volume in question. Verify those with NSSMU.
    - NFMS Support Team

  • Iomega StorCenter ix2-200 ver 2.1.44.30050

    Help me...
    Hope there is someone who can help me
    I bought 2 x 3tg WD HD and nestled in my Iomega StorCenter ix2-200
    2.1.44.30050 ..
    How do I get it to work ??
    I hope son body help me

    Hello AllanUrup
    What is the issue you are having when trying to use the ix2-200?
    Have you already checked the ix2-200 Knowledge Base regarding the issue?
    If you are having issues using the WD 3 TB disks with the unit, be sure that you followed the upgrade guide from here.
    Also just a heads up, the ix2-200 did not ship with disd larger than 2 TB.  Some users have been able to use larger disks, however it usually ends up causing RAID instability.  
    The ix2-200 Cloud Edition and higher support disks larger than 2 TB officially. 
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Iomega StorCenter ix2-200 version 2.1.48.30125 - can't browse folders

    Hi, I have a Iomega StorCenter ix2-200.  Everything is working fine, I can browse and access folders using windows explorer.  BUT, as soon as I added it to our domain, if I access it from explorer using \\192.168.3.15\ it will prompt me for a password, and no password is working....so I cannot see any folder. I would like it to work as any NAS do, meaning I would like to see the folders and then set permissions on them. I do not want it to prompt for a password.  What am I doing wrong?  thank you!

    Hello lorenzo_phse,
    Are there any local users stored on the NAS?
    Those credentials should work.
    Have you tried mapping one of the shares from a Domain machine?
    It might also be worthy to note here that the firmware version is fairly old and it is possible that there may just be a compatibility issue.
    Here is a link to the support page for the ix2-200:
    https://lenovo-na-en.custhelp.com/app/cust_alp/p/1031,1071

  • Xsan User Quotas

    I got the official word from Apple regarding a bug in the Xsan User Quotas program: Although the program accurately reports quotas for the users, the program will NOT report quotas for the groups that the user is in. You'll have to use Xsan Admin to check on the group quotas. I'm annoyed that such a simple tool doesn't work, but I'm glad to find out the problem's not on my side.
    Xsan   Mac OS X (10.4.3)   Xsan 1.2

    Hi,
    mess_user wrote:
    Does anyone know if messaging server 6.3 supports mailbox user quotas over 6 Gb?, because in messaging server 5.2 we had some problems using user quotas of 3GbAs Jay said, larger quota's are supported in 6.3. The reason why iMS5.2 was unable to support a quota larger then 4GB is that it didn't support the use of the K,M,G extensions in the mailquota: user attribute.
    http://docs.sun.com/app/docs/doc/819-4437/6n6jckqv5?a=view
    So for iMS5.2 the limit was restricted to the largest value of a signed integer. For MS6.3 "The maximum quota value of the user mailbox is 4096G".
    Regards,
    Shane.