Where is "Immediately Goto Cleanup on Sequence Failure" stored?

1. When I set "Immediately Goto Cleanup on Sequence Failure" on the Station Options dialog, where is that property stored? I want to have the process model set it and not let operators set it.
2. If I am running the Batch model, and one socket fails, what is a good way to terminate the other socket(s), or make the other socket(s) jump to their own cleanups?
Thanks,
cc

Hello cc,
For your first question, you can use the TestStand API to set the Engine.StationOptions.AlwaysGotoCleanupOnFailure property to True.  This has the same affect as setting the Station Options manually.
You second question is more tricky.  One way that you can have the other TestSockets go to their clean up is by sharing a FileGlobal.  If one TestSocket fails, then it would set this variable to true.  Then all of the other TestSockets would check this variable before each step to see if there is an error; if so, then they would branch to clean-up of that sequence.  You will most likely want to use the ProcessModelPreStep and ProcessModelPostStepFailure Engine callbacks in your process model.  They will fire at the appropriate time in your client sequence file (not in the process model where you defined them).  I hope this helps.  Have a greay day!
Best Regards,
Software Engineer
Jett R

Similar Messages

  • Reading Configure- Station Options- Immediately Goto Cleanup on Sequence Failure Checkbox Setting

    In TestStand 3.5, how do you programatically read the status of the Configure->Station Options->Immediately Goto Cleanup on Sequence Failure checkbox?  How would you programatically set this value?
    Solved!
    Go to Solution.

    Thanks for the reply, but I tried your suggestion and it cannot resolve the reference.  When I typed in Engine. it was immediately replaced by RunState.Engine. so I used RunState.Engine.StationOptions.AlwaysGotoCleanupOn Failure.  When the step was executed, there was an error stating "Unknown variable or property name RunState.Engine.StationOptions".  When I go to the context tab, I see the Engine object, but I cannot expand to see what elements it contains.  Any further suggestions?   How does one find out what "Engine" contains anyway?

  • Several executions in parallel : goto cleanup of another sequence

    Hi guys,
    My test sequence has this architecture : it launches 2 executions in parallel and for them to finish. In these 2 executions are placed several subsequences and test to verify my UUT (see image attached).
    My test sequence should follow this behavior : some of my subsequence are crucial to my test, so any step failing inside these sequences (and only these ones) should stop the UUT test. These sequences are set to 'go to cleanup on step failure'. Then my first idea was to add a post-expression to these sequences in order to terminate my 2 executions.
    => It works fine but I'm running into this issue : http://www.ni.com/white-paper/14067/en#224640_by_Category . I need to have the correct status of my test sequence, I can't accept that it returns 'Passed'. 'Terminated' or even better 'Failed' status in mandatory for me (reporting purpose).
    So the second idea was to go to the cleanup of my two executions when one of this critical sequences have a fail status... But I can't find a way to set the PostAction to target a step (group) outside of the current step's sequence.
    Any idea ?
    Attachments:
    Architecture.png ‏25 KB

    There is a way to detect that the execution was terminated. You can do the following:
    1) Specify an object reference variable to store a reference to the execution when creating the sequence call.
    2) After the wait step for the execution (i.e. after the execution has stopped), do something like:
    Locals.myExecution.AsExecution.GetStates(Locals.runState, Locals.termState)
    If the execution was terminated then Locals.termState == 2.
    Hope this helps,
    -Doug

  • Step failure causes sequence failure Option

    Hi !
    I need some clarification about the Step failure causes sequence failure Option , I'm using TS 4.2 Under Win XP .
    Lets say i have a Seq with 4 steps in all of then Step failure causes sequence failure Option is Checked .
    Record Result in all of the3 steps is Checked , If the first step will fail will it perform the next steps ? and will it record the result for this steps ?
    Thank U . 
    Kobi Kalif
    Software Engineer

    Record Result in all of the3 steps is Checked , If the first step will fail will it perform the next steps ? YES
    and will it record the result for this steps ? YES
    What this is signifying, is if a Step fails then when the Sequence has completed and returned back to the caller the status of this step will be FAILED.
    If you need to jump to Cleanup then you will need to set the Post Action.
    regards
    Ray Farmer
    Regards
    Ray Farmer

  • How to terminate on Sequence Failure?

    HI,
    I would like to terminate the test upon a sequence failure.  However ONLY from sequences called by the MainSequence!!
    I tried to set in the PostAction --> Terminate on Fail, but it didn't stop?!
    Can you recommend a way to accomplish it?
    Also, I would like to see a Failure mark (red FAIL) on the failed sequence (if possilbe)
    Thanks
    Rafi

    Rafi,
    i tested your request and most of the things are working just as you request them:
    - A failing step configured as Post-Action Terminate at Fail will terminate the execution.
    - A sequence terminating by this action will get the result "Terminated"
    What does not work as you (seem to) desire:
    - The execution will never instantly stop, not with termination nor with abort.
    - The result "Terminated" is displayed in a dark blue box within the Sequence Editor. There will not be the result Failed for the subsequence.
    The execution will never instantly stop because TestStand always waits until possible active modules have finished. If you use the default SequentialModel, this method of temination should instantly initiate the termination procedure. Within this procedure though, all steps in the "Cleanup"-stepgroups are called going up the callstack. This is an important feature which cannot be changed.
    Regarding your failure mark: do you use an UI other than the Sequence Editor?
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Activate or skip "Record Results" and "Step Failure Cause Sequence Failure" for all steps of a step type

    Hello all,
    I am using teststand 3.1
    Is it possible to skip or activate ´"Record Results" and "Step Failure Cause Sequence Failure" for all steps of a step type.
    It is very much work to do this for all steps, because I have hundred of steps
    regards
    samuel

    hi,
    here is an example that will change the TS.NoResult. You just have to change this area of the sequence to suit your needs
    I haven't added any fancy stuff, such as adding a filedialog to get the seq file to change, you will find the various variables in the Locals.
    Hope it helps
    There is a version for 3.1 and 3.5.
    Regards
    Ray Farmer
    Regards
    Ray Farmer
    Attachments:
    ChangeStepTypeRunMode.zip ‏30 KB

  • 0x800700002 Tast Sequence Failure

    Hi guy's,
    I'm having a bit of a problem in trying to image a Dell OptiPlex 7020 machine in SCCM. I have downloaded the SCCM CAB & WinPE drivers from the Dell website, split them off so I am only using 32bit drivers, and I have then imported them into SCCM, adding
    the WinPE drivers to our WinPE image and updating the corresponding distribution points.
    The image process appears to go fine, and when it gets to the very very end of the TS, it throws up a 0x800700002 Task Sequence Failure error message when trying to access one of the packages. I did an ipconfig at this stage and the machine didn't have
    any IP address settings......I checked this again at the start of the image process, and the machine DOES have an IP address assigned at the beginning, and accesses this very same package perfectly fine at the beginning when it has an IP address. 
    I have re-imported the drivers a number of occasions, but this hasn't made a difference. All access rights appear to be in place, and older model machines we have image perfectly fine without any issues.
    I tried posting up the log, but the forum here has complained about not allowing images/links until my account is verified.
    Can anyone offer any assistance? I've been testing and trialling for nearly a week trying all sorts without success.
    Thanks  

    Anyone? Any suggestions? :)

  • Tables where the survey questionnaire and response information gets stored

    Dear experts,
    Could you please help me with the information on the tables where the survey and survey responses will get stored in the system?
    Thanks and regards,
    Ranjan

    Hi,
    These are all talbes in SRM relates to Survey.
    ROST_LANG_QSTN        Language Selection for Question 
    ROST_PCAT_QSTN        Assign Product Category and Questionnaire to Lan 
    ROST_SEL_PRODCAT    Product Categories for Regis 
    ROST_WS_QSTN            Web Survey Questionnaire 
    ROS_BP_PC_SURVEY    Assign Vendor, Product Category, Survey 
    CRMD_IC_SCRATTR        Script/Survey attributes (Interactive Script Editor) 
    ROST_WS_QSTN            Web Survey Questionnaire 
    ROS_BP_PC_SURVEY    Assign Vendor, Product Category, Survey 
    TUWS_SURVEY              Survey 
    TUWS_SURVEY_LOG     Survey Log 
    TUWS_SURVEY_PUB      Survey Publishing 
    TUWS_TAROBJ               Survey: Recipients 
    TUWS_TAROBJ_ATTR    Survey: Recipient Attributes 
    Regards,
    yaniVy
    reward if helps

  • Where are stats that are gathered using dbms_stats stored?

    where are stats that are gathered using dbms_stats stored?

    http://docs.oracle.com/cd/E11882_01/server.112/e16638/stats.htm#PFGRF94765

  • Where is the background picture for a window stored?

    Greetings,
    Where is the background picture for a window stored? What is the file called? I am trying to find the image used on a DVD.
    Thanks

    when you set a picture to be a background of some folder that picture is not moved from its original location. instead a record is made in the .DS_Store file of that folder indicating that this picture is the one to be used for the background. in case of the DVD it is likely sitting in some hidden folder right on the DVD.
    run the following terminal command to enable showing hidden files in finder
    defaults write com.apple.finder AppleShowAllFiles 1; killall Finder
    then look on the dvd and the picture should be there somewhere. if you still can't find it open the .DS_store file of the folder in question using Text Editor. a lot of this file will be unreadable but the picture path will be present in plain text.
    when done rerun the above command after changing 1 to 0.

  • Where can I find the WEP password/number stored on my mac

    Where can I find the WEP password/number stored on my mac.?

    Assuming you saved it it will be in your Keychain (Applications > Utilities > Keychain Access)
    Regards,
    Shawn

  • Where is play count and watched/unwatched data stored?

    Where is play count and watched/unwatched data stored?
    Is it on file or somewhere else?

    I don't know where play count is stored, but, when using list view for songs
    Go to menue toolbar item 'View' - on the drop down list that appears choose 'View Options...'
    In the window that opens up check the box next to Play Count
    now iTunes will keep track of how many times you play each song.
    But, if you follow the same menue path while movies are in list view mode, the play count option does not appear to exist for movies, although date last played is an option.
    If you don't check the box in view options, I don't think iTunes will keep track of song play count. The only data from past use of any individual item iTunes can show is probably limited to that items' metadata that you can see using the 'get info' option for any selected item.

  • Where is my signature from Mail/Preview Markup stored?

    I just found out about adding my signature to documents in Mail and Preview (way cool!) and was wondering where the digital file of my signature is stored.
    I was really impressed by the quality of the signature and now I'd like to use it in other places as well
    I'm using a 2013 MB Air with 10.10.1 installed.
    Anyone have any guidance?

    The usual location for iTunes media is indeed <User's Music>\iTunes\iTunes Media however you can set up iTunes so that you can add in media stored in other locations such as an external drive. Check the setting under Edit > Preferenecs > Advanced for the location of the media folder in case you changed it at some point. You can see the location of any individual file by right clicking on it and clicking Show in Windows Explorer.
    tt2

  • Option ReTest Sequence Failure

    Hi All,
    I'm quite new in test stand and I need some help on my test program.
    I have a local sequence created on my main sequence. I shall call this sequence as "tuning".
    This "tuning" sequence actualy tests if the unit is tuned properly.
    In most cases the first tuning always fail. So I want to give them the option to retune it and redo the sequence again.
    I can do a pass fail count on the looping properties for example "Stop after 1 pass or a maximum of 10 Iterations" in which to my understanding
    is the operator can tune it upto 10 ten times before it could be considered a fail unit.
    My problem is that sometimes after one tuning test the operator can tell right away that it is a helpless case and it can not be tuned. So i dont want them
    to wait until ten times before failing a unit since the sequence cycle time is quite long.
    I want to give them an option to fail the unit right away if they think its a failure maybe after trying 4-5 times.
    This where my question goes::: how do i approach it?
    Advise will be gladly appreciated.
    Best Regards,Ray

    This is what I have done.. I don't know where I'm getting wrong..
    Attachments:
    11.seq ‏9 KB

  • Comenting code - style - how to keep coments where you want them - without using sequences

    Silly question maybe about style of commenting.
    Basically i like to use sequence boxes to keep comments on my diagram beside the bits of code that they refere to - otherwise when you use diagram cleanup (which i'm afraid i use all the time) they go anywhere.  This is good - except that i found especially when doing FPGA programming the sequence boxes reduce the amount of parralelism that can go on - since the 'box' needs to finish before any of the outputs can be used.  Is there some other method i should be using instead of sequence boxes to keep text beside elements - without enforcing that a set of elements are fixed in one place?
    Solved!
    Go to Solution.

    I usually use labels of structures (loops, cases, etc) and labels of diagram constants, etc. for comments. In newer versions, we also have wire labels.
    (see also)
    What is your LabVIEW version? Also the LabVIEW 2011 cleanup does a better job keeping diagram comments together with the related code compared to earlier version.
    LabVIEW Champion . Do more with less code and in less time .

Maybe you are looking for

  • Photoshop Extracting seems to have frozen. What do I do?

    I've downloaded Photoshop CC, but the "extracting" process has taken over 2 hours with broadband cable access. What can I do?

  • " Flow control: Entry SAPMV45B, PSTC, P1, *   , *   , * is missing in T185"

    Hi all, I have an order with 5 line items, and all are from same plant. When i try to change some thing for line item 5 system is saying that " No status object is missing for SDI xxxxx/50, where as xxxxx is a sales order number and 50 is line item.

  • Can't boot from Windows 7 DVD

    I'm running OS X 10.7.1 on a Mid-2007 MacBook Pro, and trying to install Windows 7 Professional 32 bit via Boot Camp. The partition went fine, but when I try to reboot off the DVD, I get something very strange. It boots to a grey screen, and flashes

  • Cannot delete mails or rename folders in icloud mail

    Hi evereyone, I lately realized a strange behaviour of my iCloud mail account. No matter where I try to rename or delete a folder (icloud.com, iPhone, iPod touch,2 iPads) I get an error message that it is not possible to do so. If I try to delete a m

  • Display doesnt show anything

    I have iPod nano (2nd generation). It worked fine till yesterday and all of sudden it doesnt show any words on its screen. Normally it shows which music is being played, photos etc. but it has stopped doing so. I tried by restart/restoring without an