BW Load Failed at Source system

Hi Experts,
I have situation where my extraction in the source system was terminated(Job termination log is below).
i would like to know the steps to re-execute the extraction process in a particular chain
as the repeat button is not available.
( Can i go to the particular infopackage and reschedule the package in schedule >)
Waiting for reply.....
Date        Time      Message                                                                               
31.03.2009  03:11:58  Job started                                                                      
31.03.2009  03:11:58  Step 001 started (program SBIE0001, variant &0000000059428, user name BWALEREMOTE)
31.03.2009  03:11:58  DATASOURCE = ZEXTRACT_ACTUALS                                                    
31.03.2009  03:11:58  *************************************************************************        
31.03.2009  03:11:58  *           Current values of selected profile parameter                *        
31.03.2009  03:11:58  *************************************************************************        
31.03.2009  03:11:58  * abap/heap_area_nondia......... 2000000000                              *       
31.03.2009  03:11:58  * abap/heap_area_total.......... 2000000000                              *       
31.03.2009  03:11:58  * abap/heaplimit................ 40000000                                *       
31.03.2009  03:11:58  * zcsa/installed_languages...... E2                                      *       
31.03.2009  03:11:58  * zcsa/system_language.......... E                                       *       
31.03.2009  03:11:58  * ztta/max_memreq_MB............ 64                                      *       
31.03.2009  03:11:58  * ztta/roll_area................ 6500000                                 *       
31.03.2009  03:11:58  * ztta/roll_extension........... 2000000000                              *       
31.03.2009  03:11:58  *************************************************************************        
31.03.2009  03:11:58  1 LUWs confirmed and 1 LUWs to be deleted with FB RSC2_QOUT_CONFIRM_DATA         
31.03.2009  11:47:24  ABAP/4 processor: DBIF_RSQL_SQL_ERROR                                            
31.03.2009  11:47:24  Job cancelled

Hi Veeru,
              Check here......
DBIF_RSQL_SQL_ERROR error
Re: Shortdump with Runtime Errors  'DBIF_RSQL_SQL_ERROR'
Re: error in data loading
Thanks,
Vijay.

Similar Messages

  • Error Occures while loading data from Source system to Target ODS

    Hi..
    I started loading Records From source system to target ODS.while i running the job i got the following errors.
    Record 18211 :ERROR IN HOLIDAY_GET 20011114 00000000
    Record 18212 :ERROR IN HOLIDAY_GET 20011114 00000000
    sp Please help me in these following Errors..
    Thanks in advance,

    Hello
    How r u ?
    I think this problem is at the ODS level, ZCAM_O04 is ur ODS Name.
    Could u check the ODS Settings, and the Unique Data Records is Checked or Not ?
    Best Regards....
    Sankar Kumar
    +91 98403 47141

  • DS-BW:Data load called from BW failed after Source System program_id change

    Hi,
    In my BW 7.0 instance I have Data Services 3.2 as source system.
    Some time ago I have changed instance of Data Services I am connecting to - I just changed PROGRAM_ID in RFC connection parameters for that source system.
    Since that time when I am trying to execute infopackage to call a job I am getting following error:
         OCI call <OCISessionBegin> for connection <xxxxxxx> failed: <ORA-01017: inv
    where <xxxxxx> is Oracle database connection name for Data Services instance I connected originally.
    What can be reason for that?
    Regards,
    ak

    In Data Services Server Manager on DS box there were configurations for job server I connected originally and for the other job server. After removing original config it works fine.
    ak

  • Extraction failing after source system and client copy

    Hi all,
    We refreshed our source QA system with a copy of production.  And basically tried to "restore" the connection from our BW QA system.  Some of the datasources can be extracted from BW, others fail with an error of "No transfer structure is available for InfoSource 0COSTCENTER_ATTR in the source system".
    Trying to do the same thing with RSA3 in the source system, works fine.
    The strange thing is it works for some objects but not others.
    here's what we did:
    1. System copy from R3 Prod to R3 QA
    2. Client copy with R3 QA client 300 -> 200
    3. Restore connectivity in BW QA to the R3 QA system (Using RSA1 -> Source  System -> Restore)
    4. Now some objects can be extracted in BW, others fail as I mentioned above.
    I have regenerated the transfer structures in BW and R3. 
    All of these objects that don't work seem to work in RSA3 on the R3 system but not in RSA1 on BW.
    All the SAP documentation is geared to copying the R3 source system and then restoring connectivity between BW and R3.  I don't think any of it involves copying the client in the R3 source system - which might be causing our problems.
    We are using an SAP delivered PDF and note 886102 mainly for direction.
    SAP PDF is "How to... System Copy in SAP Business Intelligence System Landscapes".
    Does anyone have any ideas?
    Thanks,
    Kevin

    Hi,
    can you isolate somehow the kind of DataSource which works and those who don't?
    Master data / transactional or client dependent and not, delta or full....
    To which R/3 client is your BW connected? when you succeed loading the data, is it coming from the right client?
    RSA3: do you run it specifying your BW client in the target sys field? does it make a difference if yes or if not?
    Are your RFC connections and partner profiles all right?
    Check some IDOCs sent by BW received in R/3 and vice-versa (RSSEND, RSINFO, RSRQST..). Load a hierarchy (via IDOC)... verify that your IDOC have the correct partner settings....
    let us know
    Olivier.
    Message was edited by:
            Olivier Cora

  • Error in Delta load; error in source system

    Hi,
    I'm extracting from 0FI_AA_11.
    Performed a full load.
    Then initialized without data transfer.
    When i run delta (0 records) , it fails with 'error in source system' .
    Strangely, when I run delta again in REPEAT mode, it runs succesfully.
    this is happening everytime i run delta.
    Please help

    FI_AA_11 is sure capable of handling delta.
    It does have some dependencies with master data and these are pretty awkward sometimes.
    I don't know when you are running your deltas (during opening hours from the office?) but in your process chain also the MD objects must be present.

  • Master data load from 2 source system

    Hi all,
            I am working on a project which has 2 source systems.
    Now I have to load master data from 2 source systems without making 0LOGSYS as compunding
    attribute. Because all the objects which i want to use compunding attribute are reference
    objects for lot of other info objects. So, i dont want to change the business content
    objects structure. Please guide me
    Thanks

    Hi,
    I cube there is nothing to do with compounding attribute, it will be handled in MD IO level.  As your requirement to separate the transaction happen in different source system then make add another info object as Zsource and make it as nav. attribute then design your report based on nav. attribute.
    Note that this separation is only possible in Material Related transaction not for others.
    Thanks
    BVR

  • System slow during loading data from source system

    hi,
    I am trying to load master data from r/3 into bw in quality envirnoment by means of a process chain. The problem is it being a master data load is consuming a lot of time. My development and quality environments are maintained on the same server. I doubt about this being something related to memory. If anybody could mention the ways through which memory can be monitored along with the reason for the slow nature of the system would be very helpful.
    Source system: R/3.
    Environment    : Q03(quality)
    Load               : Master data(full load)

    Hi,
    I will suggest you to check a few places where you can see the status
    1) SM37 job log (In source system if load is from R/3 or in BW if its a datamart load) (give request name) and it should give you the details about the request. If its active make sure that the job log is getting updated at frequent intervals.
    Also see if there is any 'sysfail' for any datapacket in SM37.
    2) SM66 get the job details (server name PID etc from SM37) and see in SM66 if the job is running or not. (In source system if load is from R/3 or in BW if its a datamart load). See if its accessing/updating some tables or is not doing anything at all.
    3) RSMO see what is available in details tab. It may be in update rules.
    4) ST22 check if any short dump has occured.(In source system if load is from R/3 or in BW if its a datamart load)
    5) SM58 and BD87 for pending tRFCs.
    Once you identify you can rectify the error.
    If all the records are in PSA you can pull it from the PSA to target. Else you may have to pull it again from source infoprovider.
    If its running and if you are able to see it active in SM66 you can wait for some time to let it finish. You can also try SM50 / SM51 to see what is happening in the system level like reading/inserting tables etc.
    If you feel its active and running you can verify by checking if the number of records has increased in the data tables.
    Thanks,
    JituK

  • Regarding master data loading for different source systems

    Hi Friends,
    I have an issue regarding master data loading.
    we have two source systems one is 4.6c and another is ecc 6.0.
    First i am loading the master data from 4.6c to bi7.0.
    Now this 4.6c is upgraded to ecc6.0.
    *In 4.6c and ecc6.0c master data is changing.
    After some time there is no 4.6c, only ecc 6.0 is there.
    Now if i load master data from ecc6.0 to bi7.0 what will happen.
    Is it possible ?
    Could you please tell me?
    Regards,
    ramnaresh.

    Hi ramnaresh porana,
    Yes, its possible. You can load data from ECC.
    Data will not change, may be you may get more fields in datasource at r/3 side, but BW/BI side no change in mappings structures are same. So data also same.
    You need to take care of Delta's before and after upgrade.
    Hope it Helps
    Srini

  • CO-PA Delta load - Errors in source system RSM 340

    Hi,
    We are facing a unique error when we do a CO-PA delta load. The error message is as follows:
    "Errors in source system RSM 340,The selected data source is locked by another process RD 156"
    The load completes successfully with 0 delta records fetched. When we re - trigger this after sometime, the load goes through.
    Can anyone explain as to why this issue occurs ? Basically, looking at the root cause.
    We are pulling data from CE1XXXX table, the delta for which is pulled into BW with the setting of 30 minutes safety delta. Just wanted to understand how is it that in this scenario we are faced with a lock issue ? It is also confirmed that while the delta load is initiated the transactions are being passed into the CE1XXXX table.
    Thanks,
    Amit Mitra

    Hi PK,
    caller 09 error mainly because of source(target system) and destination(bw system) not configured correctly.
    i think you get the error message as follows. file is in the client workstation as like.
    better you contact basis people. they will resolve this.
    hope this help you
    Regards
    Harikrishna N

  • Info IDoc received with status 8 in BI but Data available in source system

    Hello Experts,
    I am loading Budget Period (attributes) into PSA in BI.
    Budget Period data Loading Issue : No data available while loading. But source system ie ECC has data in that data source
    Data source: 0PU_BDGTID_ATTR
    This is full load.
    I checked that whether I am making any mistake during data selection. I could not find any issue. Message while loading data into PSA (Yellow Traffic light)
    No data available
    Diagnosis
    The data request was a full update.
    In this case, the corresponding table in the source system does not
    contain any data.
    System Response
    Info IDoc received with status 8.
    Procedure
    Check the data basis in the source system.
    Already looked this thread and googled also.
    Re: IDoc received with status 8.
    Check points:
    sm58 - NO issue
    BD87 in ECC (RSINFO Idoc status: 03) -sucessful
    BD87 in BI (RSINFO Idoc status : 53)
    ST22 - NO issue
    sm37 - Job is successful (I could see Idoc no in ECC source system in Job log)
    I am not sure if I am missing any thing.
    Thanks
    Rana

    Hi all,
    I've got exactly the same issue with several extractors. I'm inialising the Master Data in a all new system, in the Quality the loads succeeded but in Prod it failed.
    For instance with the basic DataSource "0FUNCT_LOC_TEXT", I've made the following test:
    RS3 (R/3) - > 0 data
    ST22 -> no short dump
    WE05 (Idoc) - > everything is ok
    I reactivated the Datasource in R/3 (RSA5) and then deleted it and replicated it in BW but the same issue occured.
    Any ideas?
    Thanks
    jak

  • Data load fails from DB table - No SID found for value 'MT ' of characteris

    Hi,
    I am loading data into BI from an external system (oracle Database).
    This system has different Units like BG, ROL, MT (for Meter). While these units are not maintaned in R3/BW. They are respectively BAG, ROLL, M.
    Now User wants a "z table" to be maintained in BW, which has "Mapping between external system Units and BW units".
    So that data load does not fail. Source system will have its trivial Units, but at the time of loading, BW Units are loaded.
    For example -
    Input Unit (BG) -
    > Loaded Unit in BW (BAG)
    Regards,
    Saurabh T.

    Hello,
    The table T006 (BW Side) will have all the UOM, only thing is to make sure that all the Source System UOM are maintained in it. It also have fields for Source Units and target units as you have mentioned BG from Source will become BAG. See the fields MSEHI, ISOCODE in T006 table
    If you want to convert to other units then you need to implement Unit Conversion.
    Also see
    [How to Report Data in Alternate Units of Measure|https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/b7b2aa90-0201-0010-a480-a755eeb82b6f]
    Thanks
    Chandran

  • BI 7.0: Source System upgrade from R/3 Enterprise to ECC 6.0

    Background:
    I am relatively new to BW team and will be going through my 1st source system upgrade.
    We currently have BI 7.0 SPS 17 connected to source system R/3 Enterprise EP1.
    We are upgrading to the source system to ECC 6.0.
    In Development and QA Environments:
    we will have access to both old (R/3 Enterpirse) and the new (ECC 6.0) source systems.
    We have a opportunity to compare the BW Objects, data flow and data loading from
    both source systems.
    In Production, however, we will just upgrade over 3 days downtime.
    One Question that comes to mind in this regard...
    What sort of things, we should be checking for before and after upgrade in Dev/QA and in Prod environments and what tools are available that can help the analysis and validation process ?
    Some of the suggestions that were given to me include following points.
    Before Upgrade:
    1 Check data, taking pre images of it for testing with post upgrade.
    2. Perform proper analysis of Source system related BW objects.
      - A complete listing of actively used Datasources,.. etc.
    3. Make delta queues empty,
    Make sure that all existing deltas are loaded into BW.The last request delta must not deliver any data and must be green in the monitor.
    4. Stop Process chains from BI (remove from schedule) and collection runs from R/3 side
    After Upgrade:
    1 After the OLTP upgrade, refer to note 458305 and other notes that are relevant to the actual upgrade
    (depending on the R/3 system release / R/3 plug-in to BI plug-in compatibility).
    2. Check logical system connections. Transactions SMQS, RSMO and SM59, If no access, then we can use Program RSRFCPIN_NEW for RFC Test.
    3. Check and/or Activate control parameters for data transfer. SBIW ---> General Settings --->
    Maintain Control Parameters for Data Transfer
    http://help.sap.com/saphelp_nw70/helpdata/EN/51/85d6cf842825469a51b9a666442339/frameset.htm
    4. Check for Changes to extract structures in LBWE Customizing Cockpit 
        - OSS Notes 328181, 396647, 380078 and 762951
    5. Check if all the required transfer structures are active. See OSS Note 324520 for mass activation.
    7. Check if all Source system related BW Objects are active - Transfer rules, Communication rules, update rules,DTPs,..etc. 
    Below is a link for some useful programs in this regard.
    https://www.sdn.sap.com/irj/scn/wiki?path=/pages/viewpage.action&pageid=35458
    6. Test all important datasources using RSA3 and check for OLTP Datasources changes .
    As soon as BW notices that the time stamp at the DataSource in the OLTP is newer than the one in the transfer structure, it requests replication of the DataSource and activation of the transfer structure. Transfer the relevant DataSources only if required, and transfer only the ones that have changed (RSA5 -> Delta).
    7. Create Data flow objects (trnasfer rules, infopackages, trnasformations, DTPs) for the Replicate
    new/changed datasources,if needed. 
    8. Check all CMOD enhancements.
    If we are using a customer exit with the extractor in the OLTP, see Note 393492.
    7. Check for unicode (all custom programs or Function Modules for DataSources)
    5.  Check all the queues in RSA7, start delta runs and test data consistency.
    For delta problems:In the BW system, start the 'RSSM_OLTP_INIT_DELTA_UPDATE' program for the DataSource and the source (OLTP) system for which the init selections are then transferred from BW into the ROOSPRMSC and ROOSPRMSF tables in the source system so that the delta can continue.
    9. Take back up of data posted during upgrade for contingency planing.
    10. Run the entire set of process chains once if possible and let it pick up no data or the usual master data.
    Since we have lot of experts in this forum, who have probably gone through such scenario many times, i wanted to request you to Please Please advise if i have stated anything incorrectly or if i am missing additional steps, OSS Notes, important details...

    Thanks Rav for your detailed post and very helpful contribution by posting all the information you had regarding the upgrade.
    We have similar scenario -
    We are upgrading our source system from 4.7 to ECC 6.0. We have our BI system with BI 7.0 at support pack 19 (SAPKW70019).
    Our strategy in ECC deployment  ->
    In development we copied our old DEV 4.7 system DXX to new ECC system DXY (new system ID).
    In production we are going to use same system PRXX upgraded from 4.7 to ECC.
    Now we are in testing phase of ECC with all interfaces like BI in Dev.
    My questions are below ->
    How can we change/transfer mapping of all our datasources in Dev BW system BID to new ECC dev system DXY (Eg. Logical system LOGDXY0040) from Old dev system DXX (Eg. Logical system LOGDXX0040). We donot want to create new datasources or change all transfer rules/Infosources for old BW3.x solutions on our BI.
    Also in new ECC sourcesystem copy  we see all datasources in Red in RSA7 transaction. Do we need to initialize again all the datasources from our BW BID system.
    Is there any easy way for above scenario ?
    Please let me know if you have any further helpful information during your ECC 6.0 upgrade connecting to BI 7.0 system.
    I have found some other links which have some pieces of information regarding the topic -
    Upgrade R/3 4.6C to ECC 6.0 already in BI 7.0
    http://sap.ittoolbox.com/groups/technical-functional/sap-bw/sap-r3-migration-and-sap-bw-version-1744205
    BI 7.0: Source System upgrade  from R/3 Enterprise to ECC 6.0
    Re: ECC 6.0 Upgrade
    Re: Impact of ECC 6.0 upgrade on BI/BW Environment.
    ECC 5.0 to ECC 6.0 upgrade
    Thanks
    Prasanth

  • Source System security Model

    HI,
    We built a datastore object which gets data from two R3 systems. Even master data is loaded from both source systems and compounded with source system. We want to build a security model where each company cannot access other companyu2019s data. For that we built an authorization object with source system ID and created three separate roles. (  one for company A, one for company B and the other for all).
    While building queries, if source system ID is not there in the query, it brings the data of both companies. We would like to model in such a way that other company cannot/should not see the data.
    Can any one suggest a better security model for this scenario.
    Thanks in advance.
    Tony

    Hi Tony,
    What I mean by data elements is things like company code, plant, sales org, etc.  If you are pulling in data from 2 separate systems then these will be key bits of data which will be reported on.  You can then do as Raghu has suggested and base your restrictions against them, assuming that that they are different (i.e. the naming convention for company code is not the same in your 2 source systems).
    You can still have the concept of company1 role, company2 role and combined role, you just list the restriction elements in each role that will give you the segregation of data visibility.

  • Source system deletion

    Hi ,
    We have two R/3 systems as Source systems for our BW.
    Right now,both are in a postion to give data for lot of Data targets.
    And now, we are planing to drop one source system.
    So, kindly give me an idea about the steps to be followed
    to make sure that there will be no problems after dropping
    (like Metadata inconsistency...etc) .
    Kindly provide few notes on this issuse also.
    With rgds,
    Anil Kumar Sharma .P

    Hi Anil!
      i think first you got to remove all the source system assignments for all the InfoSources with this particular source system by deleting transfer rules.  one more thing is about logical system dependency of your data, i mean if there is any data which has 0logsys compounded and the data is loaded from this source system. then determine what you are going to do with this data and how you are going to refer it in future.
    and once you are sure there is no link between this source system and BW. you can then delete this source system by justselecting delete in the context menu of this source system.

  • Error is data loading from 3rd party source system with DBCONNECT

    Hi,
    We have just finished an upgrade of SAP BW 3.10 to SAP NW 7.0 EHP1.
    After the upgrade, we are facing a problem with data loads from a third party Oracle source system using DBConnect.
    The connection is working OK and we can see the tables in the source system. But we cannot load the data.
    The error in the monitor is as follows:
    'Error message from the source system
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.'
    But, unfortunately, the error message has no further information.
    If we look at the job log in sm37, the job finished with the following log -                                                                               
    27.10.2009 12:14:19 Job started                                                                                00           516          S 
    27.10.2009 12:14:19 Step 001 started (program RSBATCH1, variant &0000000000119, user ID RXSAHA)                    00           550          S 
    27.10.2009 12:14:23 Start InfoPackage ZPAK_4FMNJ2ZHNNXC6HT3A2TYAAFXG                                              RSM1          797          S 
    27.10.2009 12:14:24 Element NOAUTHORITYCHECK is not available in the container                                     OL           356          S 
    27.10.2009 12:14:24 InfoPackage ZPAK_4FMNJ2ZHNNXC6HT3A2TYAAFXG created request REQU_4FMXSQ6TLSK5CYLXPBOGKF31G     RSM1          796          S 
    27.10.2009 12:14:24 Job finished                                                                                00           517          S 
    In a BW 3.10 system, there is no  message related to element NOAUTHORITYCHECK. So, I am wondering if this is something new in NW 7.0.
    Thanks in advance,
    Rajib

    There will be three things to get the errors like this
    1.RFC CONNECTION FAILED
    2.CHECK THE SOURCE SYSTEM
    3.CHECK IT OUT WITH Oracle Consultants WEATHER THEY ARE FILLING UP THE LOADS.TELL THEM TO STOP
    4.CHECK I DOC PROCESSING
    5.FINALLY MEMORY ISSUES.
    6.CATCH THE DATA SOURCE FIRST CHANGE IT AND THEN ACTIVATE AND RUN THE LOAD
    7.LAST IS MEMORY ISSUE.
    and also Check the RFC connection in SM59 If  it is ok then
    check the SAP note : 692195 for authorization