Code under code group disappear after creation

Hi all,
I have two questions on following which are link to each other:
Q1 u2013 Code created inside a newly created code group is disappearing.
>> When I created a code group using QS41 with status of the code group indicated as u201CReleasedu201D. Next I went to create three codes with individual defect class under the code group screen. Lastly, I hits save.
>> Next, I went to QS42 (display) on this code group. However, surprisingly, all the codes created under this code group were disappeared. May I know why?
Q2 u2013 Using defect class to activate a defect record as quality notification automatically during defect recording.
>> I read this section in SAP help portal that I can activate a defect class in customization to automatically activate a quality notification (i.e. so that the defect class can automatically activate a defect record as quality notification during result recording so that the user can continue process the quality notification. How do I do this in system since I keep on getting problem on question 1 on above? Even after question 1 on above solved, what are the relevant steps that I require to configure in order to make this function working?
Thanks
YY

Hi Gajesh,
It is on Quality client.
May I know why the codes created in the group code are diappear after the code were create?
What about question 2.
Appreciate.
YY

Similar Messages

  • All but 1 theme per group disappeared after Premiere Elements 4.0 crashed on start of burn to DVD

    I have a project that is approximately 1 hour in length.  This is the first project I am attempting to burn.  I assigned a theme to the project and then proceeded to burn a DVD.  Before the burn could actually start, PE crashed with a "blue screen" dump.  I rebooted in Windows safe mode, then rebooted back into normal Windows mode.  When I started PE and opened the project, nearly all of the themes were missing!  It appears that only one theme per group remained.
    What would have removed or hid the themes?  I would have also expected all or none of the themes, rather than leaving just one per group.  I was using a template in the "General" group, but the one that remained after the crash is not the one I had assigned to my project.
    Does a reinstall restore the templates?   If so, can I reinstall PE 4.0 from my CD without erasing, distroying, or losing the current projects I have created?
    Thanks in advance for your comments!

    Hunt,
    Before diving into the details of the items in the article, I did a few of the basic things:
    stopped my anti-virus product (doh!)
    stopped the temperature monitor software (doh!)
    did a quick disk cleanup
    turned off all trivial stuff in msconfig
    I rebooted the system and started Premiere Elements.  I had not attempted to reload the templates at that point, so I proceeded to "Burn to DVD".  I selected the minimal quality and started the burn.  That worked!   Next I exited PE and restarted it and then was able to successfully "Burn to DVD"  using the max setting for quality. As expected, it took a while to finish, but it also completed successfully!  The resulting DVD looks and sounds great, so the rendering and burn phases seem to be working fine on my hardware.
    I noticed on the CD that there is an option to load the themes, so I am going to try loading that today.  I'll post more comments after I get the themes reloaded in case there are other steps involved in restoring those within the program.

  • Nokia 6630 - Contacts Groups disappeared after fir...

    Hi! I just made a firmware update to my Nokia 6630. Before that I made a backup of my contacts using the backup function in Nokia PC Suite 6.81.13.0, and on my RS-MMC memory card. After the succesfull update, and restoruing my backup, all my groups have dissapeared, so the ring tones setting of each contact are gone. Is there a way to save the grops ore have I done something wrong? Thanks in advance.

    Hello!
    From which backup did you restore that?
    Andrey
    6150, 8310, 2100, 6310, 6310i, 6230, 6600, 6630, 6700, E60, N80, E61, N93
    N95, E61i, E71, E72,8600, 5800, N8

  • Tab groups disappear after rebooting the operating system

    I've customized some tab groups.
    Then I close the FireFox (FF) in this way: Button FF in the upper left corner - > Exit. Then I open the FireFox - and I can see all my customized tab groups.
    So, the problem is...
    When I reboot my computer and then open the FireFox, all my tabs which were in tab groups are shown only in one window! So that I see only one tab group, where there are all tabs, which were in those groups.

    Which security software (firewall, anti-virus) do you have?
    Some security software has virtualization or sandbox features that may cause problems by protecting and restoring files in the Firefox profile folder.
    App (pinned) tabs and Tab Groups (Panorama) are stored as part of the session data in the sessionstore.js file in the Firefox profile folder.
    *http://kb.mozillazine.org/Session_Restore
    *https://support.mozilla.org/kb/restore-previous-session
    Make sure that you do not use "Clear Recent History" to clear the "Browsing History" when Firefox is closed because that prevails and prevents Firefox from opening tabs from the previous session.
    * https://support.mozilla.org/kb/Clear+Recent+History

  • Workflow is vanishing after creation

    Hi,
    using MDM 5.5 SP6.
    I'm connecting via the rich clients from my desktop pc th the server.
    Visio is installed locally.
    Visio enhancement / plugin is installed.
    I'm just trying to get to know the workflows. So far everything ist fine. Found some nice descriptions and "how-to"s about the topic.
    Nevertheless - the problem I came across today puzzles me now for some hours.
    How come that some of the workflows (in fact most) disappear after creation?
    So what do I do?
    - having a validation rule created
    - adding a new workflow
    - giving name and code and description
    - designing the workflow with viso - refering to the validation rule
    - rule looks like: start - process - validation - approve - stop
    - pressing the save button!
    - closing visio
    - trying to apply the workflow to some records for testing
    - then - the context menu - "add to job" is greyed out - there is no workflow available
    - back to the workflow table - "here it is"
    - pressing the viso button (the trhee dots)
    - visio opens - but empty...
    So what do I do wrong?
    Is the workflow file supposed to be saved at a special place on my hard drive?
    Maybe someone can give a hint...
    Thank you in advance
    Martin

    Hi Martin,
    Your Workflow created in MS Visio is not getting saved correctly thats the reason you are not able to run the workflow.
    - Try creating a very simple workflow say Start->Process->Stop and then check if you are able to execute the workflow.
    - Also make sure you are using the right compatible version of MS Visio ie 2003 with MDM.
    - Also refer the below document to check and see taht you have perform the right settings needed.
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/90990743-91c0-2a10-fd8f-fad371c7ee40
    http://help.sap.com/saphelp_mdmgds55/helpdata/EN/81/13f2753fa44b2f913cb69379130319/content.htm
    Hope It Helped,
    Thanks & Regards
    Simona Pinto

  • SAP QM unable to pick Code group & code in creation of defect in QA32

    Hi every one,
    I am new to QM , can any one guide me to solve this issue.
    In T code QA32 after results recording, am trying to maintain defect document of one of reject MIC. But, i am unable to pick Code group or code. System showing error "Code group QM-Q contradicts the code group of the catalog profile "
    Regards
    Srinivas

    Hello Srinivas,
    Check below path and let me know what settings you have maintained.
    Now, Also check your Catalogs profile, You have to maintain Catalog "Z" for the same catalog profile.
    Amol.

  • Delegate Calendar Entries disappear seconds after creation

    Environment.
    Exchange 2010 on prem. Office 2013. CEO and COO have the same Executive Assistant. This person has Manage Full Access Permissions for both CEO and COO.
    She regularly adds calendar events to either persons calendar without issue for the past 5 months since she started. Until today. Now, on either calendar, as soon as she creates a Meeting or Appointment, it disappears after 3-10 seconds.
    Ran the repair process on Office. Same issue. Removed the Manage Full from both accounts and added it back. Same issue. Had both CEO and COO manually give her delegate access through Outlook. Same issue.
    Any suggestions would be much appreciated.
    Thanks.

    I was faced with the exact similar problem of my COO sharing her calendar with 2 admin assistants whereby one of them was having issues updating
    the calendar as they would vanish within 20-25 seconds after creation whereas the other assistant was successfully able to do so without any problems even though she was also on cached mode.
    After banging our heads with zillion’s of tests of profile, online mode, offline mode, new profiles, New Laptop, New Configuration, Active Sync
    devices such as Apple, BB, Androids and going through lot of hue and cry on forums, I opened up a call with Microsoft and they pointed me to Exchange 2010 registry entries which eventually did the job. I would only like to summarize my solution which is:
    Refer to
    http://technet.microsoft.com/en-us/library/ff477612(v=exchg.141).aspx
    for default values which will be altered in the solution.
    Event ID 9646 was being logged under my application event
    viewer indicating the following error
    Mapi session “ “ exceeded the maximum of 500 objects of type "objtFolder".
    RESOLUTION:
    To resolve this issue, you simply need to create the following registry keys on each of your mailbox servers.
    Navigate to HKLM > System > CurrentControlSet > Services > MSExchangeIS > ParametersSystem. Create a new key in ParametersSystem
    named MaxObjsPerMapiSession. In MaxObjsPerMapiSession, create a DWORD named
    objtFolder with a decimal value of 600.
    Please note that the DWORD keys should have the same upper and lower case combination therefore copy it from the article above and paste
    in your registry.
    The Information Store will pick up these changes after a few minutes; you do not need to restart the Information Store service. If you continue
    to see this error, only this time specifying that the user has exceeded the new 600 object threshold, increase the value of each DWORD by 100 until the errors stop.
    Similarly, you can see Event ID 9646 indicating other objects also being exceeded as per the above Tech Note and similarly registry entries need
    to be keyed in resolve the issue.
    You will also have to see the user side Sync Issue logs under outlook as they keep indicating various error codes which relate to these problems
    and many more. At times we tend to ignore such logs however are very meaningful.
    Sharing this to minimize a lot of headaches for fellow colleagues who should not suffer the way we did.
    Cheers
    Faisal Khan.

  • Error in notification- Wrong Code group displaying

    While creating Notification, we can assign codes for defect loc, def type and causes. After that, If I go in change mode of same notification, code group for defect type and causes are default taking as code group assigned for defect location.
    Also the code group for defect type and causes are not even displaying in screen.
    But the data for defect location is showing everything fine, means code group, codes.
    Summary:
    In QM02- Change Notification
    Defect Location:
    Code group- Correctly displaying whatever assigned during creation of notification
    Defect Loc code: Correctly displaying
    Def Loc description- Correctly displaying
    Def Type:
    Code group- Displaying same code group of def location
    Defect type code: No display
    Defect type description- No display
    Causes:
    Code group- Displaying same code group of def location
    Causes code- No display
    Causes description- No display
    Did anyone faced the same issue before. If so plz ley me know
    Thanks
    Vineeth

    Closed, enhancement done in PM Notification caused this error. Internal error. Solved

  • Code groups & codes -catalog

    hi pm gurus,
    we have customised catalog code for our pm-cs notificatcations.
    we have code groups & codes under catalog.
    we have created lot of code groups & codes in code groups, now we wanted to delete or deactivate or block some of the  code groups & codes. how this is possible ?.
    pl help.
    regards
    srihari

    hi,
    Please note down the path for deactivation of catlogs.
    SPRO --- Plant maintenance & customer services - --- Maintenance & service processing -
    maintenance and service notification -
    notification creation -
    notification conents....Maitain Catalog..
    click on define catalog....
    What u r asking is only about... catalog that's  is the combination of code groups.....
    from here u can deactivate catalog...
    incase of doubt please ask...
    Regards,
    Amit kushwaha

  • Restrict UD code group for Inspection type

    Hi,
    I want to restrict UD code groups for each inspection type.
    Let say : for 01 Inspection type - system has to show only 01 code group.It should not display the remaning code groups(02,03....)
    sridhar.R

    Hi,
    To achieve this you need to create separate Selected Sets.
    Run QS51----> Create a Selected set with Catalog type "3 - Usage decisions"  E.g. Z01 is created for Inspection type 01.
    Here you assign only Code 01 (Don't assign the un necessary codes)
    Now Follow the Customizing path....
    SPRO->Quality Management->Quality Inspection->Inspection Lot Creation->Maintain Inspection Types Execute========>
    Select inspection type 01 and assign the previously created selected set (Z01) here at the field "UD selected set"
    Now system will populate only those codes that are covered under the selected set Z01.
    Do the same for rest of all inspection types.
    Regards,
    Shyamal

  • Budgeting at company code & group level

    Hi,
    I am working on ECC 6.0. Client requirement is to create budgeting from lowest level till company code level. After that the budgeting is also needs to be reflected at the group level as a combined for all the group companies.
    Kindly let me know how can I do that in R/3 or any additional module will solve the requirment
    Regards,
    Ajay

    Hi Eli,
    Thanks again for your inputs.
    If I assign the same FM area to all the company codes. What steps do I need to carry out. Can sugges me some links where I can find the details of the same.
    Regards,
    Ajay

  • QS41 and QS51- code group error

    Hi,
    I am trying to create new code groups in QM. i have maintained the defect classes and the catalog types. then in QS41 I have maintained the code groups for the catalogs along with the codes. All the code groups are in released status. In the next step in QS 51 I am trying to edit the selected sets but when I enter the catalog, plant and the set the error message qs204 comes which says 'Selected sets are not defined for these catalog types'. and the performance assistant recommends maintaining the table TQ15so that selected sets are allowed for the catalog type.
    Why is this error coming? after I have maintained all the required catalogs. Kindly help me with the solution as soon as possible as it is quite critical.
    Thanks,
    Ariel.

    Hi,
    This is the correct community regarding your subject. please let me know what is the type of catalog your creating selected for. SAP allows you in standard for creating selected sets only for some of the catalogs namely Usage decision, Character attributes
    If you need to maintain selected for other catalogs you have to do the customisation
    SPRO > QM > Quality Planning > Basic Data > Catalog > define Catalog Type> choose the catalog > maintian  Selected sets allowed
    Hope this helps
    Regards
    Gajesh

  • Selected set assignment to code group

    I have maintained a catalog " S", under which i have maintained code groups and codes in QS41, but here the usage indicator is deactive. I cannot select it.
    Now when i use QS51,i am unable to view the codes. the selected set is empty. In this case how to assign the code groups and codes to seleccted set.
    any help, i am new to qm

    There is some confusion you have in code gr & selected set.
    In simple words -->in QS41  you create defect codes & code gr for catalo types like 1,3,9 etc.
    But in QS51 you combine different codes from code grs to form selected sets.Practically selected sets are only used for   Characteristics attributes(1) and Usage decision(3) and by default they carry valuations.
    For catalog defect type (9) I would suggest to add and create your own codes and code groups as per business requirement in QS41.You should not actually create selected set for catalog 9.
    for more details  refer :
    http://help.sap.com/saphelp_40b/helpdata/en/2d/3508f6448c11d189420000e829fbbd/content.htm

  • Catalogs, code groups and codes not available in service order in Web UI

    Hi,
    I have created and maintained a subject profile for the service orders that i am using for my business scenarios. The same is visible under the objects tab in transaction data of the service order business transaction in the SAP GUI.
    However the same are not visible anywhere in the Web UI (they are not available in the list of available fields as well in BSP_WD_CMPWB for BT116H_SRVO).
    Can some1 pls advice me with the steps so as to make the catalogs, code groups and codes in my service orders available in the Web UI screen as well.
    Will really appreciate if detailed steps are provided since I am new to Web UI technology.
    Warm regards,
    DP

    Deepak,
    I'm 99% sure (although dont quote me as I dont have a developer key so I cant finish my testing) that you're missing the context Nodes - so although you have the assignment block yuo have no link between the code set and the service order header.  You havent referenced them in your comments on this post in any case. 
    Try this:
    Go into BSP_WD_CMPWB
    In the Browser component Structure open folder Component > Views
    Double-click BT116H_SRVO/DetailsOV and in the structure expand to BT116H_SRVO/DetailsOV > BT116H_SRVO/DetailsOV > View Controller  > DetailsOV.do > Context
    Right-click on folder Context Node and click Create
    Follow through the wizard defining a Z context Node (e.g. ZBTSubject) and a Model Node of BOL Entity BTSubject
    Define any Dependencies etc you may wish to have and so on (most of the wizard is optional)
    Repeat the same for the BOL Entity BTSubjectSet
    Now go back in and see if your values are populating.  I'm not a developer (and never have been), so I cant guarantee this will work as I dont have a developer key to test this, but I am quite sure that this needs to be done for you to get your values populating.
    Good luck, Merry Christmas and a Happy New Year (& please award points if useful!)
    Andrew Griffin.

  • Code Groups not visibile in QS41

    He experts,
    I have created catalogs by t-code: QS41.
    After the entering and saving the code groups and codes system is not showing the codes for the code groups.
    Only code groups are visible. However I can see and use the code groups while donig transaction i.e. in notification in filling the history details.
    Please tell me if there is any settings need to be done so that codes are visible in QS41.
    I am working in ECC6.0
    Regards
    Pankaj Verma

    This is a basis problem. install note number 1078292. Read the below summary , you will get the proper information.
    Summary
    Symptom
    This note has been created to correct a bug introduced by the note 1067720. The symptom is related to the Selection Condition for Character fields, where preceding spaces are truncated, in View Maintenance.
    Other terms
    View Maintenance, Selection Condition, VIEW_FILL_WHERETAB, note 1067720, wrong output, QS41, QS42, QS51 QPAC, QPAM, QPCD, Catalogs, Codes
    Reason and Prerequisites
    The error is due to a wrong correction done in note 1067720.
    Solution
    Please apply the attached corrections.
    Header Data
    Release Status: Released for Customer
    Released on: 25.02.2008  13:37:14
    Priority: Correction with medium priority
    Category: Program error
    Primary Component: BC-CUS-TOL-TME View Maintenance Tool
    Secondary Components: CS-CM-SN Service Notification
    PM-WOC-MN Maintenance Notifications
    QM-PT-BD-CAT Catalog
    Affected Releases
    Software
    Component Release From
    Release To
    Release And
    subsequent
    SAP_BASIS 60 620 640 
    SAP_BASIS 70 700 700 
    SAP_BASIS 71 710 710 
    Correction delivered in Support Package
    Support
    Packages Release Package
    Name
    SAP_BASIS 620 SAPKB62065
    SAP_BASIS 640 SAPKB64023
    SAP_BASIS 700 SAPKB70014
    SAP_BASIS 710 SAPKB71004
    Corrections Instructions
    Correction
    Instruction Valid
    from Valid
    to Software
    Component Type *) Last
    Modifcation
    578289 700 700 SAP_BASIS C 26.07.2007  11:43:00
    578290 710 710 SAP_BASIS C 26.07.2007  11:55:27
    943249 640 640 SAP_BASIS C 20.10.2007  12:59:47
    943250 620 620 SAP_BASIS C 20.10.2007  13:01:23
    *) C Korrektur, B Vorarbeit, A Nacharbeit, M noch nicht bestimmte Arbeit
    Related Notes
    1091604 - SM30: Error SV068 on Selection Conditions
    1067720 - SM30: Improper selection of entries in the table/view
    440521 - Overview: Notes for FS-RI
    Print Selected Notes (PDF) 
    Causes - Side effects
    Notes / Patches corrected with this note
    Note
    reason From
    Version To
    Version Note
    solution Version Support
    Package
    1067720   1078292 1