Connecting two error out wires to one error in wire

Ok, here's my problem, i'm programming an application and want to send two error out wires from two different daq assistant inputs into the error in of one daq assistant output.  I've tryed to merge the signals but Labview doesnt let you merge together the two signals.  I tryed to convert the signals but i couldn't find anything that would let me convert them.  If you could give me any advice, it would be greatly appreciated.  If i have to, i will attach an example of my application and give a explanation of what im trying to do.  Thank-you.

When you refer to "error wires" I assume you are talking about error clusters. Yes? If so see the attached VI to merge two error streams. Whatever you do, do not use the Merge Errors VI that NI wrote as it can throw away error data. The attached VI preserves all the data it gets.
To use it, wire one error chain to the left terminal, the second one to the middle terminal and the output is the right terminal.
Mike...
Certified Professional Instructor
Certified LabVIEW Architect
LabVIEW Champion
"... after all, He's not a tame lion..."
Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps
Attachments:
Error Fork Stacker.vi ‏55 KB

Similar Messages

  • Final Cut Pro Error: 'out of memory'/'general error' on export

    I'm trying to export a simple timeline from FCP but keep getting Final Cut Pro Error: 'out of memory'/'general error'. Exporting 5 sec timeline (yes, just a short trailer) via Quicktime conversion H264 at 1080. Strangely, if I export exactly same timeline at 720 its fine. Original media ProRes422 1080.
    Have exported at 1080 before ok. No nested files involved; re-connected all media; no JPEGs involved; plenty of memory (all of which i have heard can be issues).
    Any advice please as i've read all of the FAQs and nothing helping so far?!
    Spec: New MacPro 12-core; 12 MB ram; 2TB drive; FCP7

    Thanks for workflow clarity Shane, but when you export as self-contained QT movie, what do the 'Current Settings' refer to? Is this the current settings of your (source media in) timeline (ie in my case Pro Res 422) or the last settings used by the export? Apparently 'If you deselect the Recompress All Frames option and choose Current Settings from the Setting pop-up menu, Final Cut Pro simply copies frames from existing media files into the new file with no recompression.' But when i did this I got a 994.1 MB QT movie, which, when i got 'more info' told me MPEG-2 Video (?!) Apparently a compressed file when its supposed to be uncompressed (?!) When i exported manually setting to Pro Res I got 6.77 GB. Clearly uncompressed Apple ProRes 422 (HQ). Do i have to manually set settings to Pro Res to match my source media and ensure i get an uncompressed file? Im searching boards to get some clarity on this too: all references so far advise using 'current settings' but dont actually say what they are.

  • Connecting two BW systems to the one R/3 source system

    Hi all!
    I have to connect two BW Systems to one R3 system. In our last tests we have had problems trying to connect two BW  servers simultaneously with R/3 source system because it allows only a logical system name for each R/3 client, and (We guess that we need to define tow diferent logical system name, one for each connection). This has been generating errors when we try to load data from R/3 to BW because, we guess, R/3 does not recognize the BW source system in the ALE connection for someone BW systems at transfer data. In this moment I have one connection active (BW1-R3). The BW2-R3 connection is already inactive. Does anybody know how perform this? we need solve the transfers problem as soon as possible.
    Thanks!  Judi

    Ah...
    please don't post twice the same question...in these forums we are always the same !!!
    You can close this thread to avoid to look in two different posts...
    Bye,
    Roberto

  • Connecting two Mac minis and using one monitor

    I am thinking about getting two Mac minis to run concurrently, accessing both on the same Thunderbolt Display (also to be acquired) using screen sharing and connecting the two Macs via firewire (or thunderbolt).
    I have certain programs I need to run in Windows (Bloomberg terminal and MS Excel in Windows version) but don't want to run them in parallel on one computer as (in my experience) the performance is very slow.
    By running two computers at the same time, I'm hoping that can avoid the entire system griding to a halt. I also think it will allow me to upgrade more cheaply as the Mac mini is improved over time.
    Is this a completely daft idea? Would I be better off with a new iMac or a refurbish Mac Pro?
    Any feedback is welcome, even of the abusive variety.

    "File sharing preferences" is indeed how to do it.  Connect both minis to your router (one by ethernet cable, one by wifi, it doesn't matter.)
    Then turn on "File Sharing" in Sharing Prefs on both minis.  Also, give them both meaningful, different names under "Computer Name".
    Then, when you open a finder window on one mini, the other one should appear under "Shared", like this:

  • CALLING ALL EXPERTS - Connected TWO Actiontec Routers to use one as main and second as GUEST

    Hello Experts-
      I have TWO Actiontec Routers from Fios. I bought the new N one, and I have an old Actiotec that I was previously not using.  So here is what I am trying to do...
    I'd like to leave Router 1 (the New N router) as my primary router (comes from ONT via cat5 wire NOT Coax) and Set-up the second router off the first to be a guest router.  So essentially make it a bridge.
    I can't seem to configure it to work correctly.  
    Can anyone out there give me a step-by-step walkthru on how to configure this second router so I can have them both hooked up, seperate SSID, with one as the Main and the other being the Guest?
    THANK YOU IN ADVANCE!
    Rob
    Solved!
    Go to Solution.

    I'm basically wondering how to change the routers IP address and where the Disable DHCP is within the menus.
    THANKS IN ADVANCE!
    Rob
    To change the IP address of the Local Area network choose:
    My Network
    Network Connections
    Click edit on the row for "Network (Home/)office"
    On the next screen click Settings
    On the next screen you can change the LAN (192.168.1.1) address to something different.
    On the same screen you can disable DHCP too.
    I hope this helps.

  • Connect two 7344 motion controllers in one PC

    Can I use two NI - PCI 7344 motion controllers in one PC. My application requires 6 axis and hence I want to use two PCI 7344 motion controllers. I am already using one. Can I configure another one in the same PC to add more axes to my current system. If yes, then how to configure the other one, so that it acts as the 5th and 6th axes in my system. I'm using LabVIEW 7.1 in my application.
    Regards,
    Giridhar Rajan
    Automation Engineer
    Cruiser Controls
    Mumbai, India

    You can add as many PCI-7344 boards to your PC as you want. The only
    limitation is the number of PCI-slots available. In your software you
    need to control the axes from the second PCI-7344 seperately from the
    axes of the first one. That means that there are no built in methods to
    start the axes on two or more boards synchronously. If this is not a
    feature that you need then everything is quite straight forward. If you
    need tight synchronization you might write an onboard program that's
    running on the second board and that waits e. g. for a breakpoint
    signal to be generated by the first board immediately after the axes
    are started.
    Assumed that you need tight motion synchronization with the additional
    axes a better choice would be to use one PCI-7356 (6 axes) or a
    PCI-7358 (8 axes) instead of two PCI-7344. The 735x boards are pin- and
    software-compatible to the 734x boards. You could return your 7344 to
    NI and buy a 735x board with a fair discount ("hardware upgrade"). If
    this is an option for you please contact your local NI branch.
    Best regards,
    Jochen Klier
    National Instruments Germany

  • Error out problems with measuring frequency VI

    I am having some error out problems with measure frequency VI. The instructions is change error out from indicator to control but does not work. Anyone can help? The VI is attached
    Attachments:
    Measure Frequency VI error.vi ‏27 KB

    This VI does not have an error out. Obviously, you replaced a subVI that did have an error out with this one, otherwise you would not have been able to create this wire.
    Simply remove the wire or save the subVI with another name then modify it to have the error out that you are looking for.
    Hope that this helps,
    Bob
    Bob Young - Test Engineer - Lapsed Certified LabVIEW Developer
    DISTek Integration, Inc. - NI Alliance Member
    mailto:[email protected]

  • Runtime constant (Filename) errors out in BPM

    Hi,
    I have a BPMCollectTime scenario to collect the Source files. The filename (Message Mapping/Transformation) from the files is captured in TRANSFORM STEP(before sending them out from BPM). The file is sent to SEND step one at a time.
    Question : Filename of the source file is captured through user defined function.
    Following is the code.
    ================
    String  v_result_time;          //test Variable
    DynamicConfiguration conf = (DynamicConfiguration) container.getTransformationParameters().get(StreamTransformationConstants.DYNAMIC_CONFIGURATION);
    DynamicConfigurationKey key =  DynamicConfigurationKey.create("http://sap.com/xi/XI/System/File","FileName");
    if (key == null) { v_result_time= "Create Key Failed";}
    else
    {v_result_time= "Create Key worked";
    String valueOld = conf.get(key);
    v_result_time = valueOld;
    return v_result_time;
    The Mapping gives a runtime error in the BPM. This is a sporadic error. 
    I have selected the Adapter specific attribute(File name).
    The BPM errors out sometimes? I am not sure if I am missing any setting. If I delete the work item and run the same scenario it works.
    Question 1 : What is the cause of the above error?
    Question 2 : Does BPM support Adapter specific attribute such as filename?
    Kindly Advice.
    Thanks,
    Gowri

    Hi Everyone,
    Thanks for all the help.
    DTN will not change the response filename to source filename. This option cannot be used. The correlation id is defined as response file name. Response filename is fixed for invoice file.
    Here is the example.
    For invoice file name HDTN20070430163110.TXT, response file received is nav1_2b5.rsp file. For HDTN20070430163314.TXT , response file is nav1_2b5.rsp
    So my correlation id is dummy fixed value. I have known the fact that it is not possible to use context object filename.
    Bhavesh -  I have defined transform step for accessing filename using dynamic configuration. Following is the code used in mapping.
    ================
    String v_result_time; //test Variable
    DynamicConfiguration conf = (DynamicConfiguration) container.getTransformationParameters().get(StreamTransformationConstants.DYNAMIC_CONFIGURATION);
    DynamicConfigurationKey key = DynamicConfigurationKey.create("http://sap.com/xi/XI/System/File","FileName");
    if (key == null) { v_result_time= "Create Key Failed";}
    else
    {v_result_time= "Create Key worked";
    String valueOld = conf.get(key);
    v_result_time = valueOld;
    return v_result_time;
    ====================================
    BPM errors out sometime with following error
    Component mapping has returned error.
    com/sap/xi/tf/_MM_DTNData_2_DTNFilename_java.lang.NullpointerException.
    Error: Exception CX_MERGE_SPLIT occurred (program: CL_MERGE_SPLIT_SERVICE========CP, include: CL_
    If I delete this workitem and repeat the same scenario, it works. I have still not understood, why the scenario works sometime.
    Kindly Advice.
    Thanks,
    Gowri

  • How to get count of records inserted and errored out in an email

    Hi
    I have following question
    I want to send report statics of scenario i.e Number of rows inserted during the scenario and
    Number of rows in error in the scenario in an email.Here in my scenario I am trying to insert data into Essbase database and when i try to use getNbInserts() and getNbErrors functions of ODI in an email body,its giving zero value even though there 140 records inserted and 10 errored out.Can any one let me know how we get this number of records inserted and number of records errored in email.
    Thanks in advance
    Regards
    Baji

    Hi
    I have following question
    I want to send report statics of scenario i.e Number of rows inserted during the scenario and
    Number of rows in error in the scenario in an email.Here in my scenario I am trying to insert data into Essbase database and when i try to use getNbInserts() and getNbErrors functions of ODI in an email body,its giving zero value even though there 140 records inserted and 10 errored out.Can any one let me know how we get this number of records inserted and number of records errored in email.
    Thanks in advance
    Regards
    Baji

  • FTP Adapter Errors out while translating

    Hi,
    I am using a FTP adapter to put a text file using a bpel process. But the FTP adapter errors out with the following error:oracle/xml/parser/schema/XMLSchema
    Is there a way to fix this issue?? Please advise.
    Thanks
    PS

    Hi,
    To do the alert configuration as suggested, please go through the information below.
    From SP 14 on PMI-free alerting was introduced. That means before SP 14 one has to configure and activate the End-to-End Monitoring, and to schedule the report SXMSALERT_PROCESS_DATA_GET in order to extract the alerts from the PMI data. For SP 14 and higher, that's not longer necessary.
    If no alerts are being delivered, please check if "Suppress multiple alerts of this rule" is checked for your rule.
    For SP 14 and higher you could also have a look at the report sxmsalert_logreader. This report shows some information about alerts being created or not.
    You'll find more information about trouble shooting the alerting in SAP Note 913858.
    Also just check if this batch program (RSALERTPROC) is running or not.
    The links below on Alert Management (ALM) will be of good help to you:
    http://help.sap.com/saphelp_nw04/helpdata/en/3f/567ddea69d3d4c93a6aedabd08899e/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/3f/81023cfa699508e10000000a11402f/frameset.htm
    Meanwhile look at these forum threads also:
    Alerts not getting triggered from Adapter Framework
    Alert  Configs...
    Also, In ALRTCATDEF, go to SETTINGS--> CONFIGURATION. By default, the option selected is INTERNAL PROCESSING. Select the option SMTP FORWARDING AS XML and give the email id. This will enable you to send an email alert whenever an error occurs in XI.
    I hope I have answered your queries. If u want help with anything else please do reply back.
    Regards,
    abhy
    PS: AWARD POINTS FOR HELPFUL ANSWERS.

  • PATCH 5903765 Errors out

    Hello:
    While applying the patch one of the worker process errored out with the following error in our development environment:
    Generating report "FNDRSRPS.rdf" with command:
    /u01/dev/appldev/devora/8.0.6/bin/rwcon60 userid=APPS/***** source=/u01/dev/appldev/devappl/fnd/11.5.0/reports/US/FNDRSRPS.rdf dest=
    /u01/dev/appldev/devappl/admin/DEV/out/tmp006.rdf stype=rdffile dtype=rdffile logfile=/u01/dev/appldev/devappl/admin/DEV/out/adrep00
    6.txt overwrite=yes batch=yes compile_all=yes
    /u01/dev/appldev/devora/8.0.6/bin/rwcon60: error while loading shared libraries: libjava.so: cannot open shared object file: No such
    file or directory
    ERROR [code=127] generating report "FNDRSRPS.rdf" from input file
    /u01/dev/appldev/devappl/fnd/11.5.0/reports/US/FNDRSRPS.rdf
    Looks like some thing went wrong with the environment setup in DEV.
    I ran the command on the DEV instance and this is what we got..
    ldd $ORACLE_HOME/bin/rwcon60
    libjava.so => not found
    libXm.so.2.1 => /usr/X11R6/lib/libXm.so.2.1 (0x07245000)
    libXt.so.6 => /usr/X11R6/lib/libXt.so.6 (0x0109d000)
    libX11.so.6 => /usr/X11R6/lib/libX11.so.6 (0x069fd000)
    libXp.so.6 => /usr/X11R6/lib/libXp.so.6 (0x06197000)
    $ echo $LD_LIBRARY_PATH
    /u01/dev/appldev/devora/8.0.6/lib:/usr/X11R6/lib:/usr/openwin/lib
    But when I run the same command in Production instance this is what I got
    ldd $ORACLE_HOME/bin/rwcon60
    libdl.so.2 => /lib/libdl.so.2 (0x00ac2000)
    libm.so.6 => /lib/i686/libm.so.6 (0x011de000)
    libpthread.so.0 => /lib/i686/libpthread.so.0 (0x0138b000)
    libjava.so => /u01/prod/applprod/prodora/8.0.6/network/jre11/lib/i686/native_threads/libjava.so (0x014db000)
    libXm.so.2.1 => /usr/X11R6/lib/libXm.so.2.1 (0x0240b000)
    libXt.so.6 => /usr/X11R6/lib/libXt.so.6 (0x01201000)
    libX11.so.6 => /usr/X11R6/lib/libX11.so.6 (0x01a27000)
    libXp.so.6 => /usr/X11R6/lib/libXp.so.6 (0x00e85000)
    $ echo $LD_LIBRARY_PATH
    /u01/prod/applprod/prodora/8.0.6/network/jre11/lib/i686/native_threads:/u01/prod/applprod/prodora/8.0.6/network/jre11/lib/linux/native_threads:/u01/prod/applprod/prodappl/cz/11.5.0/bin:/u01/prod/applprod/prodora/8.0.6/lib:/usr/X11R6/lib:/usr/openwin/lib
    What went wrong with the environment? Can any one guide me on this?
    Regards,
    Bala

    I have already replied to this in the thread you had opened for this issue, it is not related to OAF, post it in reports forum
    PATCH 5903765 Errors out
    Tapash

  • Connecting Two Power Supplies in one PC

    Hello there  :hypecrite:
    Will someone help me on how to connect two Switching P/S in one PC (If it's possible)?
    I tried using two P/S in my old PC and it's working just fine. However, the problem is that I cannot switch them on simultaneously because the one is connected directly to the motherboard and the other, I just used a simple switch to turn it on.
    Also, please check my P/S for this PC if it's OK.
    Thank you and more POWER!!!
     :hypecrite:

    Hello again :hypecrite:
    Thank you for your support guyz.  I would like to tell you that you are all correct.
    I think it's time for me to stop fooling aroung, experimenting things, too.  And to trust the verdors instead.  I looked for the psu brands that you all mentioned and it turned out my pockets could still handle such a cost, eventhough it costs twice as much as the psu that I have right now, but as long as it's dependable.
    And about the problem with my CPU's temperature that I posted last November 12, 2004 (MSI KT4A-V with S/PDIF out and Core center), AMD support center finally replied to me and told me that my temp is OK but not to go above 70C.
    Below is my inquiry to AMD and their reply:
    My inquiry:
    Dear Sir:
       I would like to ask what is the NORMAL operating temperature of Athlon XP 2400+ FSB 266 model 8?  
       When my PC is at idle, my CPU temp reading is 60C and during full load, it reaches to about 66C. It doesn't have any problems though (such as random reboot) but I'm a bit concerned of the temperature reading.  Some people say that it's a bit TOO HOT  for comfort. Still others say that it is OK.  What do you think?
      I have read your post on MAXIMUM operating temperatures of Athlon XPs but not the recommended NORMAL operating temperatures.
      And also when I turn  the BIOS CPU core voltage to AUTO mode the default is 1.575V. My friends said the minimal operating voltage of 2400+ is 1.650V. Is it OK to just leave it to default?
    Thank you very much
    Sincerely,
    Mark E. Guillem
    Philippines
    My PC Specifications:
    AMD Athlon XP 2400+ (Family 6, Model 8, Stepping 1), FSB266 256L2
    GlobalWin TAK68 CPU fan (dual fan, ball bearing 5200RPM max each)
    MSI KT4A-V (VIA KT400 chipset) BIOS ver. 2.3 date: 09092004 (with MSI Core Center)
    512MB DDR333 mem (2x256MB)
    Inno3D GeForce FX 5200 128MB with AGP8x w/ TV out
    80GB Maxtor 7200RPM 1x133
    40GB Seagate 5400RPM 1x100
    LiteON LDW 411S DVDRW 40x12x40
    LITE-ON XJ-HD166S DVDROM 16x
    Pinnacle PCI PCTV Rave TV tuner/capture card
    OS: Windows XP SP2
    The Reply:
    Dear Guillem,
    Thank you for contacting Asian and Pacific AMD Technical Support Centre.
    I can confirm that the temperatures ranges from 40° - 55° C  in moderate usage and with a higher workload around 65° C, but never over 70° C.
    What the correct voltage is concerned there are three models of the Athlon XP 2400+. If you have the CPU with the OPN AXDA2400DUV3C the
    voltage should be 1.60V otherwise it is 1.65V.
    It seems your system would overheat dangerously when set to the right voltage. I would suggest, you do check if the heatsink /fan is installed
    properly.
    You may find a different reading after upgrading your BIOS.
    * Please make sure to download the right BIOS version for your motherboard.
    Then, please, make sure that your processor Athlon XP 2400+ is configured in BIOS as follows:
    -          FSB speed to 133MHz (It is a bidirecctional bus, the full speed would be 266)
    -          CPU multiplier of 15x
    -          CPU voltage of 1.65V (1.60V if OPN = AXDA2400DUV3C)
    With these settings the clock frequency of the processor should be 2000 MHz.
    And finally you can test the CPU on another system to establish if the processor or the motherboard is responsible for the problem . If no other system is
    available to you then ask your retailer/reseller to test it for you.
    Given the case that the processor is faulty, we inform you that the PIB processors (box processors) have 3 years warranty, whilst OEM processors (tray processors) have only one year. In both cases the first year is given by the reseller and the PIB processors second and third years are served directly by AMD.
    If you have any further questions, please, do not hesitate to contact us again.
    Kind regards,
    Roberto Erler
    Technical Support Engineer
    Spain: 900 99 71 21 (Número Gratuito)
    France: 0800 908 621 (Numéro Vert)
    Germany: +49 89 450 53199
    Italy: 800 877 224
    United Kingdom: +44 1276 803 299
    Yesterday, I increased the CPU voltage to 1.60V (from the default of 1.575) and my temp reading was reduced to 50C at idle (from an idle of 60C) and at full load to 60C (from a full load of 66C).  I was not expecting this though.  I was expecting that my CPU's temp will increase further.  But this is what happened. I guess the RIGHT THING should be the RIGHT THING.
    Tomorrow, I will buy a new psu with the brands that you mentioned and I hope that my PC's stability and performance will increase further.
    Again thank you very much for your support and all.
      :hypecrite:

  • Procedure to Error Out Outbound IDocs

    Hello,
             I have a Requirement in which I am using ORDERS05 IDoc Type and extended it to ZORDER05 to populate Custom Fields and sending the Purchase Order Outbound IDoc to the Vendor from SAP System. Now, my requirement is that if any of the Custom Fields are not maintained in SAP and not populated in the IDoc, I need to Error Out the IDoc with Error Status 26. I am currently working on the SAP ECC 5.0. I have implemented similar Error Handling Mechanism earlier by using Enhancement Framework as I was working in ECC 6.0 environment where I've added the Code by Creating an Enhancement Implementation in the Function Module IDOC_CREATE_ON_DATABASE. But since ECC 5.0 does not have the Enhancement Framework feature,  please let me know how to achieve this.
    Thank You,
    Venkata Phani Prasad K

    Hi
    why don't you try using the standard method for validation of data?
    By implementing the customer-function EXIT_SAPLEINM_002 or BAdI MM_EDI_ORDERS_OUT  you can make checks of completeness of the idoc segments (in your case, additional custom data) and, if they were not complete, report an error message raising the exception DATA_NOT_RELEVANT_FOR_SENDING
    ie
    if <Idoc Custom Field> is initial.
    MESSAGE ID 'S1'
                   TYPE 'E'
                   NUMBER '333'
                   WITH Additional data are incomplete' 
                   RAISING data_not_relevant_for_sending.
    endif.
    Thus you have the evidence of the error in the processing log of the output message while the IDOC is not created.
    The solution works very well and is not invasive.
    Regards.
    Andrea

  • Perl adpreclone.pl dbTier errors out with RC-50013

    Hi all,
    Am performing a clone of an 11.5.10.2 system running on Redhat linux 3.0.
    When i run perl adcfgclone.pl dbTier,it errors out with the following error whenever it gets to 16%.
    AutoConfig is exiting with status 1476
    RC-50013: Fatal: Failed to instantiate driver /home/oracle/teadb/9.2.0/appsutil/driver/instconf.drv
    Raised by oracle.apps.ad.clone.ApplyDBTechStack
    StackTrace:
    java.lang.Exception: RC-50013: Fatal: Failed to instantiate driver /home/oracle/teadb/9.2.0/appsutil/driver/instconf.drv
    at oracle.apps.ad.clone.ApplyDBTechStack.checkInstallDrvErr(ApplyDBTechStack.java:717)
    at oracle.apps.ad.clone.ApplyDBTechStack.runInstallConfigDriver(ApplyDBTechStack.java:622)
    at oracle.apps.ad.clone.ApplyDBTechStack.<init>(ApplyDBTechStack.java:389)
    at oracle.apps.ad.clone.ApplyDBTier.<init>(ApplyDBTier.java:149)
    at java.lang.reflect.Constructor.newInstance(Native Method)
    at oracle.apps.ad.clone.util.CloneProcessor.run(CloneProcessor.java:68)
    at java.lang.Thread.run(Thread.java:479)
    Could anyone be having a clue of how to go about this issue?
    I read the solution on metalink and the solution i was given is to go to Note 307954.1 which tells me to "Modify the target's instconf.drv and remove the offending lines"
    Now,the problem is that the offending lines are too too many....Is there any other way round this problem?????
    Thank you in advance.

    Take a look on :
    Note:463477.1 - "Adcfgclone Failed To Run On DB Tier With java.lang.Exception: RC-50013: Fatal: Failed to instantiate driver"
    https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=463477.1
    Aviad

  • Connect two ECC systems with one SAP CRM 7.0

    Hi Gurus!
    I have to do a customizing for connect two ECC 6.0 and one SAP CRM 7.0, only I need the organizational structure from both systems and they need update when the structure from CRM has changes. The business partner goes to ECCs system by PI interfaces.
    Both organization models are different, so I have to maintain and update depending the changes in the business.
    But I don't know if this is possible, I don't know if we can do this by Middleware, ALE or PI.
    Can you please, give your oppinion about this topic?
    Best regards,
    Eugenia.-

    Hi Eugenia,
    Please see note 1084315 which descriibes the the multiple backend scenario.
    This should be relevant here.
    Best regards
    Christophe

Maybe you are looking for

  • Remove "(More Links...)" from List View Webpart if the list view shows all items

    Hi, I currently have 5 links lists out of which 4 links lists have around 30 odd list items and the rest 1 have just 3 list items. All of this links list are added as ListViewWebPart on a wiki page. All these listview web parts are configured for "Su

  • IPod shuffle not seen on USB

    I have a strange problem connecting my iPod shuffle. If I plug it into the keyboard USB hub, iTunes recognizes it and I am able to load it with music, but if I plug it into the USB ports on the rear of the G4 it is not seen at all on the Bus (System

  • Rewrite in pure html, without flash or embedded code

    I want to rewrite my site, thats now generated with wix.com, in pure html . Can I use something like dreamweaver to do this very quicky ? the sites ( LINKS REMOVED ) are not so difficult, only I know that it is difficult to create something like a ca

  • Burning MP3 CDs to be used on my car's MP3 Radio

    I am looking for an official answer from Apple stating that the songs and audiobooks that I have purchased cannot be burned as an MP3 CD (except for the ones in the "plus" format). The files are generally speaking rather expensive, but I have decided

  • How do I connect my text boxes to allow one to overflow into the next?

    In older versions, you could create a text box on one page and have it flow into a text box into a different page.  How do I do this in the newest version?  It's a pretty important function!