Conversion Problem in Unit of measure 1PAC=100,000 EA

Hi Experts,
I am facing the problem in conversion of Unit of Measures.
If some material has the conversion unit when we order to Vendor.
The Unit of measure is EA, the Order unit is PAC.
The conversion is 1PAC=100,000 EA
But the System is allowing as 1PAC=10,000 EA only and it is not allowing to enter 100,000 EA and throughing the error
Entry too long (enter in the format __,___)
Message no. 00089
How can we increase the characters of the Unit of measure. Like this we have some 50 Materials, I need to increase the length of the conversion spaces. How to do it, Please guide me.
rgds
Swamy

Hi
you can check this out the denominator factor is Stored in structure - SMEINH - field UMREN.
Best option is to maintain decimal place for the UOM , which is more easier to mainatin.
Even if you go through the note the same is explained. Please read below for Too large numerators and denominators
When 120000 CM3 = 0,2 tons (TO), you can no longer save numerator and denominator of conversion ratio 600000 CM3 = 1 TO as numerator and denominator may have maximally five digits.
Here, you must either select a larger volume unit or a smaller unit of weight: With DM3 the conversion ratio would be 600 DM3 = 1 TO, with KG the conversion ratio would be 600 CM3 = 1 KG.
Generally, the alternative units of measure and the base unit of measure should result in quantities that are in the same dimension since the conversion factors may not be larger than 99999/1 and not smaller than 1/99999.
Thanks & Regards
KK
Edited by: Kishore Kumar Chiluka on Apr 22, 2008 8:25 AM

Similar Messages

  • Problem with Unit of measurement

    Hi,
    I am having problem with Unit of measurement with different languages.
    Eg:
    In SPRO, I am able to see the unit of measure T3 Description: (Trading unit).  in SAP 200 client .the logon language is EN(english).
    But if I logon into same client(200) with different language DE(german) version, I am not able to see the description in German, the description field is blank.
    Kindly give me a solution for this problem as it is very urgent.
    Thanks in advance.
    Regards,
    Shankar

    Hi Aishwarya,
    I can think of 2 possibilities:
    1. You need to verify passing the Target UoM with the ISO Code as well as the update flag in the 'X' structures.
    2. The material that you are trying to pass some UoM does not have the conversion maintained in the Material Master. (Base UoM --> Target UoM conversion in Material Master, contact Functional Consultant).
    Also, if you can verify by performing the action manually and check if the Sales Order is getting created manually with the Target UoM .
    Regards,
    Pranav.

  • Problem of unit of measurment in production system

    Hi Friends,
    I'm facing a peculiar problem of unit of measurement like error in all quantity and curreny fields in report output after transporting a query from quality system to production system but this query is generated from multiprovdier. what might be the problem.   
    Regards,
    Srinivas.

    Hi Dave,
    Thanks for ur reply. but to trace in monitor it is not showing any error message.
    My Mail ID is [email protected]  Please the send the document
    Regards,
    bharat

  • Pricing Record Problem (alternative Unit of Measure)

    I am facing a problem in Pricing i.e that the Price is mainly maintained in Base unit of measure(CRT) but the selling is both in Crates and Bottels and the bottels is alternate UOM and Crate is the main unit of measure 90 % sales in crates. but when i enter the qty in alternative uom i.e is bottel price is not calcuated propery
    Example
    1 crt 24 bt
    Price of one crate =216
    when i enter bottels as uom the price should be 9 but system is showing 9.07

    Hi
    Litres is the Base unit of measure and Bottles and Carats are Sales unit of Measure in Ur case and u have maintained wrong figures
    Please maintained in this fashion
    1) 1 bottle  =  x litres
    2) 1 carat  = y litres
    in this way when u enter the 1 carat in Sales order system will go here and take the price of  1 litre and then multiply by ( This conversion factor in ur case y units)
    so u will get price as 1*y rs .
    In pricing please check what condition record u have maintained . Generally condition records are maintained in Base unit of measure i.e the condition record will say 1litre cost Rs  11 .
    Hope this calrify .
    Please reward -

  • Conversion in Alternate Unit of Measure

    Hi All,
    I have a report in which i report data in both base and alternate units of measure, the report has three filelds Material , Quantity (BUOM) and Quantity (AUOM). The problem is for a certain material; say Mat_1, the unit in which it is entered can be Carton or EA, i am using Carton to litre conversion, but my query fails when the material has EA as its unit. Is there a way by which i can convert the unit to litres be it in Cartons or EA???
    Kindly suggest a solution anyone pls pls help
    Thanx in advance
    Regards,

    Hi,
    You can define your own Unit Translation using Tcode RSUOM in such a way that it takes a dynamic unit from each source record with fixed target unit as Litres.
    Refer http://help.sap.com/erp2005_ehp_04/helpdata/EN/1b/325d4217139041e10000000a1550b0/content.htm for Unit Translation creation.
    You would need to ensure that unit translations are available in T006 table.
    --Priya

  • Conversion fator for Unit of Measure in BI 7.0

    Hi Experts,
    Cud you pls tell me how Unit of measure conversion works in BI 7.0. I am getting dialog box of UOM conversion in the properties of BEX but not able to convert Conversion for Unit of measure?
    Thanks in advance!
    Sapna

    Hi,
    Better define Units of measure in that KF.
    Hope it helps.
    Regards,
    Tulasi

  • Conversion of alternate unit of measurement

    Hi,
    System will not allow to enter conversions of unit of measurements in decimal points. But is there any configuration or method, we can force system to accept conversions of unit of measurements in decimal points only? (For example 2.5kg = 1pc, base unit of measurement is 'PC' and alternate unit of measurement is 'KG')
    Regards,
    Sattuj

    Hi,
    For the given example of Alternate conversion you can use the following setting :
    2.5 Kg = 1 Pc
    Put the Values as :
    25 Kg = 10 Pc
    With this the objective of Decimal is achieved.
    Please check the following posts for more info :
    [Re: variable order unit]
    [Re: Base Unit of Measure]
    [Re: Issue in unit of measure]
    Hope it helps,
    Best regards
    Amit Bakshi

  • Function module for conversion in basic unit of measure....

    Hi,
    Can someone give me a function module, which will convert the Unit of measure into basic unit of measure
    Say a a material has 3 CA (Cases) in a PO and the conversion factor(UMREZ in table MARAM) for CA for that material is 4 and converison for MP (Master pack) is 12,then
    3CA =  9 PC = (9/12) MP
    But I want a function module which will do this conversions ?

    Hi,
      Use MD_CONVERT_MATERIAL_UNIT
    Thanks,
    Naren

  • Round off problem in unit of measurement

    Dear Experts
    We are in SAP 4.7 , we are having more than 12 plants using same client.
    One of our plant requirement we were changed the UOM 'Nos' with 3 decimels allowed.So where ever we not useing decimel places we have to use UOM as 'EA' (each).This is dont have any decimel places.
    Now we are in implementation project for our one more new plant in same client. But for them we are going to introduced Batch specific unit of measurement. Base unit of measurement is KG and Batch specific UOM is EA.
    All sale material have both unit of measurement , inward or production posting in KG and we will create batch number. We will enter the coversion value of how many quantity per kg for each batch.This will be in 'EA'
    While i'm doing transfer posting or consumption or sales for the material in UOM 'EA' , it is coming with 3 decimel places.
    If the same UOM 'EA' in normal condition (without batch specific UOM) it is working correctly.It is getting roundoff correctly.
    Please help me out on this.I need the consumption should not be decimel places for UOM 'EA'.
    Suresh

    Hi Senthilkumar SD,
    You have not read the thread before posting.
    It quite clearly states that the UOM EA already has NO DECIMAL PLACES.
    Quote "<b>we have to use UOM as 'EA' (each).This is dont have any decimel places."</b>
    It is good to see lots of people trying to help and so I am pleased to see you trying, but it really doesn't help if you haven't read the question before posting the answer.
    Steve B

  • How to model a conversion table for unit of measures?

    Hi
    I am looking for some input on how to model a many-to-many relationship.
    The situation:
    A fact table with columns:
    Product
    Unit of Measure
    Date
    Value
    1 product is stored with 1 and only 1 unit of measure - e.g. Product = Oil, unit of measure = m3
    The fact contains several products, each having its own unit of measure.
    A dimension 'Unit of measures' with columns
    Unit Of Measure
    Unit Of Measure Name
    Measure System
    While reporting on the facts it should be possible to chose the unit of measure I want to see my facts in. E.g. I want to be able to show Oil-production in m3 or barrels or liters, etc.
    My challenge:
    How to model this requirement?
    Right now I tend to go for a bridge table between the fact and the dimension.
    But I was wondering:
    a) are there other ways to model it
    b) are there pitfalls in using Bridge tables?
    c) Can I re-use the bridge table in combination with other facts as the model grows?
    c.2) do I need to create an alias on the bridge table to re-use it?
    Thanks for your help
    regards
    Andy

    Hi Kart,
    ok let's say my model looks like this (columns below the tables names, sample in brackets) - again ignoring a date dimension:
    Dim_Product --- 1:n --- Fact ----- n:1 ----- Dim_UOM
    Id (1,2) Prod_id Id (1,2,3)
    Name (Oil, Gas) UOM_id Name (m3, Barrel, Litre)
    Value
    So the products are coming from the Dim_product, Unit_of measures coming from Dim_UOM.
    Fact values would look like this
    Prod_id UOM_id Value
    1 1 10
    1 2 84
    1 3 10000
    etc
    If I need to report in a new measure, I would be forced to add a new record to the fact table
    Prod_id UOM_id Value
    1 1 10
    1 2 84
    1 3 10000
    1 4 150
    with 4 being the new measure id.
    What I am looking for is a way to be more flexible when it comes to converting values to different measures.
    Thanks
    Regards
    Andy

  • Unit of measure relation 1,000,000 to 1

    Hello Guys,
    In the material master data i have the requirement to add an alternative unit of measure. The relation is 1 MIU (mega international unit) = 1,000,000 IU
    The denominator accepts maximum 6 positions (=100,000).
    We dont want to use intermediate UOM (e.g. 1 KUI = 1000 UI and 1 MUI = 1000 KUI). We want to have a direct conversion. Do you know how can i solve this problem?
    Best regards
    Manuel

    Hi Manuals,
    I had similar problem on one of the project ,denominator field length is limited to 6
    lot of communication with SAP
    But no solution ,Finally had to take intermidiate UOM
    You can try persuing SAP
    BR
    Diwakar

  • Problem in Unit of measure

    Dear Guru,
    There is a problem with one material
    One material on jan converion ( material master) should change
    1 to 7.369 to 1 to 6.39
    at the end of feb order is created for that material, Now po will take the old conversion
    at the time of R&D iam deleting the info record from Po, then it will take right conversion
    Please suggest me why it is happened
    Regards
    Kashyap Kumar

    1 to 7.369 to 1 to 6.39 is this convertion maintained info record.if yes ,after deleting inforecord system will pick convertion from material master.Check inforecord what convertion factor maintained.

  • Conversion of large unit of measures

    Dear Experts,
    To implement a critical business scenario i need to implement following conversion -
    245 X = 1000000 Y, but due to limitation of numerical digits to 5 i am notable to do this, if anybody can suggest for the same please.
    I shall be greatfull to all
    thanks in advance. point will be rewarded please.
    Regards,
    Pawan Khurana

    Further digging leads me to believe that the issue is that iOS 7 uses more RAM, and on the iPad 2, this doens't leave quite enough memory to open these 36MP RAW images.
    If I close all background apps, I have been able to get Filterstorm Neue to open and edit these RAW images, while having any app still running in the background will cause a crash. No such luck with Snapseed as I'm guessing it uses a bit more memory than Filterstorm. This would account for why PhotoRaw can open and edit these files -  it uses a virtual memory approach to load large files.
    So unless iOS 7 becomes better optimised for RAM usage, or these apps are updated to use virtual memory, looks like I'm limited in which apps can open 36MP RAW images on an iPad 2.  Wonder if a newer retina iPad would manage? They have more RAM I believe, but probably need more to run the display...

  • Multiple Unit of Measure (No Fix Conversion Formula)

    Dear All,
    Cilnet has given me requirement to book the sales document for the particualr product in unit of mesure 'Nos/PC', and the stock is maintained in Base Unit of Measure 'Qtl' (100 Kg = 1 Qtl). Price is also applicable or calculated on the basis of QTL but there is no fix conversion formula of 1 PC = How Many QTL.
    Please guide me on this point.
    Regards
    Rahul

    Hi,
    I was facing the same Problem  ,well for this you need to define a character and associate the same to a  Class .
    And Finally need to assign Combination of these to material in material master classification view.
    Define Charter :
    http://wiki.sdn.sap.com/wiki/display/PLM/Howtocreateacharacteristic
    Assign the Char to Class :
    Tcode : CL02
    Under Char Tab Give the Charcter Name and Place "S" in Org. Area.
    Thanks.
    Edited by: C.Ankit on Mar 7, 2012 8:18 AM
    Edited by: C.Ankit on Mar 7, 2012 8:18 AM

  • Unit of measure in BOM

    Hi...
    I have one problem with unit of measure in BOM.
    We can maintain item quantity upto 3 decimal point.My problem is with one of material having consumption of  0.01042 for 1pc of header material.
    Due to constraint in maintining decimal point in BOM we maintained it as 0.011 & it leads to undesired result after BOM explosion.
    I know there is one way of going with base qty. of header to be changed.
    Suggest  other else?How to get out of this.....
    Regards
    Tushar

    Hi Brhamankar...Thanx for your valuable i/p.
    We have got solution to the said problem as below(Without increasing the base quantity of header)...
    1)Create new unit of measure say TP
    2)Maintain it as alternate unit of measure with conversion as 1000TP=1042PC in material master of that component
    3)Maintain the quantity in BOM as 0.01TP
    4)Make plan entry for header level say for 50000
    5)After MRP run , procurement proposal for component as 521PC(Previously it was 550PC because restriction of 3 decimal point, in BOM rounded with 0.01042 =0.011PC)
    6)After MFBF, material consumption is also found ok
    Regards
    Tushar

Maybe you are looking for