Infotype Screen control - change field from display to change

Hello,
I have a field in a custom infotype, which is showing up as only display. I want to change it so that values can be input. I checked the screen layout in se51 and found that the field is checked as input possible field. There is no entry for this infotype in T588M. I am not sure, where else should I look so that i can change to field to take the input. Please suggest.
Thank you very much !
Rush

Hello Everyone,
I checked in Module pool Program. The program is written to check the field for some personnel areas. Now, when i did debug, I found that PSYST-werks is not read correctly. Suppose if there are 3 records in infotype 0001, its getting the first record value, not the recent record value. Any suggestions how to change the code, so that the PSYST get the recent record value?
Sikindar, T588M do not have entry for this table. thank you.
Jayanthi thank you for your help too.
Rush
Edited by: rushi K on May 13, 2008 4:15 PM

Similar Messages

  • Infotype Screen Control (T588M) not working for additional fields to contro

    Hi,
    I have a requirement to enhance IT 0002 with fields LNAMR, FNAMR and CNAME. Also field preferred language.
    I have included LNAMR, FNAMR & CNAME as additional fields in the Include Screen 2040 elements, lay editor and maintained table T582c where i have assigned enhancement to the standard screen. These fields are getting displayed in infotype 0002
    But the issue is Infotype Screen Control (T588M) is not working for these fields to control the display or hide.
    Has any of you come across this issue? what could be the reason for this issue? Please suggest ASAP.
    Thanks in advance.
    Regards

    Hi Experts,
    Please help with your inputs and suggestions.
    Regards

  • Add ifnotype field to an Infotype Screen Control for Infotype 0006

    How do I add an infotype field to an Infotype Screen Control for Infotype 0006. We need to add an additional Field for mobile phones. I have lloked in screen control (V_T588M) with no joy.
    Edited by: Henry Manana on Sep 1, 2010 12:11 PM
    Edited by: Henry Manana on Sep 1, 2010 12:12 PM

    You may copy your current screen into a new screen (e.g. 2099) for MP000600 and add the 2 fields into the element list as well as the screen layout of screen 2099. Then set an appropriate Modification Group 3 to these 2 fields in T588M detail screen for screen 2099. Configure feature P0006 and table T588M to set screen 2099 for molga 16.

  • All fields are not displaying in the infotype screen control

    Hello Everybody,
    All the fields from infotype 2001 and 2002 are not getting displayed in the screen control for these infotypes and
    when I checked the screens for these infotypes, the mod. groups/functions has not been set for field 'Group3' for those
    infotype fields.
    Is there a way I could set this field ' Group3' for these infotype fields also ? Can it be done thru screen exit and if yes could
    anyone tell me what's the screen exit for these infotypes ?
    Thanks
    Alok

    solved it myself.

  • How to make a field from display mode to change mode for a perticular tcode

    hi all,
    my client want to change one field which is in display mode of a material doc in mb02.
    Restrictions in some fields  in MIGO needs to be changed.
    Uploading point in case of issue: While editing the MIGO latter,  this field needs to be edited.
    Goods recipient in case of receipt: While editing the MIGO latter,    this field needs to be edited.

    hi thanks for quick replay,
    my requirement is, supose i post a material doc through migo in 101 mtype, in item detail, where tab i have given the good reciepitant and unloading point. but while i want to change that material doc in mb02, i saw unloading point is in change mode, but good reciepitant field is in display mode. my client requirement is to change that field. so for change that field, the field should be in change mode, so thats what i want.
    i have checked in configuration side, but i didnt get any setting, i think we have to customize that standard screen.
    any comments?
    regards,
    susanta
    Edited by: susanta bindhani on Jun 19, 2008 2:18 PM

  • Master-detail: detail field not displayed after changed by master field

    I want to use the Depends on item with Clear/refresh value functionality in a master detail situation. Within the same group it is no problem to use the setter method of a field to change a second field and then displaying this new value. But in the detail group, I can not select items from the master group as a depends on item.
    In the setter of the master field, the value in a field for each row in the detail (table layout) is updated. The only problem is that this updated value is not displayed, the old value doesn't change. When saving the changes, the displayed value is committed to the database. When de updated field is not displayed at all, the correct value is saved, so I know the detail field is updated.
    How can I make sure the displayed value in the detail is displayed after changeing a master field? I already gave the detail field the correct partial trigger.

    Wouter,
    I guese you don;t see the changed value when you display the detail item because after the depends on item update changed the detail item, JSF procesing continues and the detail table changes are sent to the server which will override again the detail item attriibute, resetting it to the old, still displayed value.
    So, the trick is to get PPR working. Make sure the partialTYriggers property of the detail item is set to the value of the id property of the master item. If it still doesn't work, try setting the partial triggers property on the table, instead of the individual item.
    Steven Davelaar,
    JHeadstart team

  • Control PO field one user can change

    Hello,
    We are implementing SRM 7 with ECS.
    We want to restrict fields a user can change in a Purchase order. How can we achieve that? For instance we do not want the user to be able to change cost assignment.
    Thanks in advance.

    The visibility and editability are controlled by IMG in SRM 7. In SPRO,
    SRM server >> Cross application basic settings >> Extensions and field controls >> Configure field control >> Configure controls for fields of substructure
    There you can hide or make accounting information display only.

  • Infotype screen control

    Hi,
    Can anyone help me with the difference between the STD and RF screen control option for the fields of an infotype in the table T588M?
    I understand that both STD and RF option makes a field mandatory. Also, 'STD' means standard Setting and 'RF' means required field at the outset.
    But please let me know the exact difference between them.
    Warm Rgds,
    Arun.M

    Hi Arun;
    Actually they are not same. There is difference.
    STD is standard and RF is required field.
    Normally STD is coming with the system standard. I mean if that field is important for every company etc, I mean that field is required for every entry then STD means same thing with RF. But in some conditions some fields are not mandatory in the system standard. So when it is STD in T588M you can leave this fields empty.
    But RF makes the field reuired field anyway and you need to enter a value to save the infotype.
    Hope I could explain it clearly.
    Regards.
    Okan

  • Read contents of changing fields from internal table

    Hi Folks,
    Please help me in my query below:
    Consider there is a Z-table with two fields TABNAM and FIELD having values KNA1 and NAME1 respectively.
    In my report I have fetched entries for customers from KNA1. Now based on the field from Z-table I want to populate a variable suppose V_FREE_VAR with the value from KNA1 table.
    Here V_FREE_VAR is of CHAR200 so that it accomodate all types of values from KNA1.
    The value of Z-table FIELD can change daily i.e next day the value may be PSTLZ.
    So how can I read the particular field from internal table as the field to be read is dynamic.
    Note: using case is not feasible.
    Thanks in advance.
    Regards,
    Shardul

    @Hartmut P
    As Rob said i want to get the value of the field from internal table. the code is something like this.
    I_KNA1 contains records for customers.
    Suppose values of Z-table are in internal table I_TEMP_TABLE.
    Entries in I_TEMP_TABLE are as follows
    TABNAME      FIELDNAME
    KNA1                 NAME1
    The value of FIELNAME in Z-table can be changed
    Loop at I_TEMP_TABLE into WA_TEMP_TABLE.
    Read I_KNA1 into WA_KNA1 with key KUNNR = '0001002234'.
    IF SY-SUBRC EQ 0.
       CASE WA_TEMP_TABLE-FIELDNAME.
            WHEN 'NAME1'.
                 V_VAR = WA_KNA1-NAME1.
             WHEN 'PSTLZ'
                  V_VAR = WA_KNA1-PSTLZ.
    ENDIF.
    But using case is not appropriate as KNA1 contains 176 fields.

  • Changing fields from run() method

    I have some threads in my program. There is one which in his run() method changes field of other class, my problem is that the change appears with some dealay. In my opinion the delay is to long. Is there any way to make it faster??
    Thanks for reply.
    Greg.

    I think can... u can set the timeslice of the thread to run faster... try looking it here...
    http://java.sun.com/j2se/1.4.2/docs/api/java/lang/Thread.html
    Hope it helps!

  • ALV from Display to Change Mode

    Hello,
             I created an application that starts with a selection screen and then the user selects either a Create/Change/Display. Then a call screen is done in which i added an ALV with some editable fields.
    The point is that when the user first selects 'Display' the ALV is all in the display mode. If he makes a BACK then goes to 'Change' the ALV is still displayed in the output mode. and vice-versa.
    Is there a reason for this??
    Please help

    hi emym,
    try this it may be helpful
    Making ALV Grid Editable
    ->To make a column editable, it will be sufficient to set the field “EDIT” in the field catalog. The ALV Grid perceives if there are some editable fields and adds buttons for editing purposes. If you do not need these new buttons, you know how to exclude them.
    ->To make individual cells editable, we will utilize the table we used for making a cell a pushbutton. As you remember, it was of type “LVC_T_STYL”. If you have not added this inner table, add it now. For this procedure; add the name of the field to the field “FIELDNAME”, and pass “cl_gui_alv_grid=>mc_style_enabled” to make a field editable and “cl_gui_alv_grid=>mc_style_disabled” to make a field non-editable, to the field “STYLE”. You can use the one with “disable” when you make an entire column editable and want just a few of cells along it non-editable.
    ps_layout-stylefname = ‘CELLSTYLES’ .
    If we want our column “SEATSMAX” entirely editable except the case “CARRID” is ‘XY’ which is a rare case and we want our cells along the column ‘PLANETYPE’ editable if their respective ‘CONNID’ fields contain the value ‘02’.
    Assume we have added our style table (“CELLSTYLES”) to our list data table and tell the layout structure about it and we adjust the field catalog so that the column “SEATSMAX” has the property “EDIT” set to ‘X’.
    refer this:
    FORM adjust_editables USING pt_list LIKE gt_list[] .
    DATA ls_listrow LIKE LINE OF pt_list .
    DATA ls_stylerow TYPE lvc_s_styl .
    DATA lt_styletab TYPE lvc_t_styl .
    LOOP AT pt_list INTO ls_listrow .
    IF ls_listrow-carrid = 'XY' .
    ls_stylerow-fieldname = 'SEATSMAX' .
    ls_stylerow-style = cl_gui_alv_grid=>mc_style_disabled .
    APPEND ls_stylerow TO lt_styletab .
    ENDIF .
    IF ls_listrow-connid = '02' .
    ls_stylerow-fieldname = 'PLANETYPE' .
    ls_stylerow-style = cl_gui_alv_grid=>mc_style_enabled .
    APPEND ls_stylerow TO lt_styletab .
    ENDIF .
    INSERT LINES OF lt_styletab INTO ls_listrow-cellstyles .
    MODIFY pt_list FROM ls_listrow .
    ENDLOOP .
    ENDFORM
    Conditionally setting fields to be editable or non-editable
    ->As usual, cell based settings override entire column settings. You can dynamically switch between cases in any proper part of your execution. Just fill your inner table as required and refresh table display; for entire column settings, set or unset the property “EDIT” of the field catalog for the column and reset the field catalog using “set_frontend_fieldcatalog”.
    ->As the last condition to be met for editability, you must call the method “set_ready_for_input” passing ‘1’ to the parameter “i_ready_for_input”.
    Using this method you can switch between editable and non-editable mode. As you guess, passing ‘0’ to the parameter while calling the method, switches to non-editable mode.
    rewrad if helpful
    regards,
    sravanthi

  • Cretit control area field - Customer master - mass change

    Hi Gurus:
    I want to use the customer master mass change program (T.code XD99) to assign a default credit control area for all the customers. However when i try to save the mass changes it does not update the credit control area, and shows an information message "0000500004 : No batch input data for screen SAPMF02D 0900" . Did anybody come across such situation ? and how to resolve this ?
    Thanks in advance.

    Refer to note 552066, The system is attempting to maintain some ETM data that may not be relevant. May be this applies to you.
    Symptom
    During the start of the mass maintenance with Transaction XD99, the system generates batch input sessions for the import of the data in the background. In the process the system also tries to supply fields RF02D-D0900 and RF02D-D0910 on screen SAPMF02D 101 with data, although these fields do not exist on the screen. Then the batch input processing terminates.
    Solution
    The correction of the source code for the generation of the batch input data is described in the corresponding correction instruction. A solution that allows also the mass maintenance of ETM data with Transaction XD99 is in preparation.

  • Infotype 0041  - Date type field in display mode always

    Hi All,
    Please help in find out solution for the below enhancement
    In infotype 0041 we have date type and date field. We need to make the date type field to be display mode always.
    Thanks for your help in advance.
    Thanks,
    Karthikeyan

    Hi Karthikeyan ,
    Please find the resolution as below :
    Userexit - EXIT_SAPFP50M_001 . In Include ZXPADU01. Write the below code .
    DATA: w_P0041 TYPE P0041.
    IF  ipsyst-massn <> space AND
      ( ipsyst-ioper = 'INS'  OR
        ipsyst-ioper = 'INSS' OR
        ipsyst-ioper = 'COP'  OR
        ipsyst-ioper = 'MOD').
    CASE innnn-infty.
    WHEN '0041'.
    *convert prelp to pnnnn structure
    CALL METHOD CL_HR_PNNNN_TYPE_CAST=>PRELP_TO_PNNNN
    EXPORTING
    PRELP = INNNN
    IMPORTING
    PNNNN = w_P0041 .
    *Here you can have more conditions like for which Action Types you want the
    IT0041 to default .
    w_P0041-dar01 = 'Z1'.
    w_P0041-dar02 = 'Z2'.
    w_P0041-dar03 = 'Z3'.
    *convert pnnnn to prelp structure
    CALL METHOD CL_HR_PNNNN_TYPE_CAST=>pnnnn_to_prelp
    EXPORTING
    PNNNN = w_P0041
    IMPORTING
    PRELP = INNNN.
    *Display mode
    LOOP AT SCREEN.
              IF screen-name = 'P0041-DAR01' OR
                 screen-name = 'P0041-DAR02'  OR
                 screen-name = 'P0041-DAR03'  .
                CLEAR screen-group2.
                screen-input = 0.
                MODIFY SCREEN.
              ENDIF.
            ENDLOOP.
    WHEN OTHERS.
      ENDCASE.
    ENDIF.
    Thanks ,
    Sucharita Das

  • Change email "from" display

    Is there any way for me to change how an incoming email is displayed on my phone? If so, I can't seem to figure it out.
    I have two different email accounts set up, and when an email comes in, I will quickly delete any SPAM or unrecognized email addresses.  Typically, I will delete several at a time first thing in the morning, for the junk that came in overnight. I have accidentally deleted ones I shouldn't have, because I didn't realize it was a work contact.
    Say I have a client, John Smith. His email is [email protected] and when an email comes from him, it will say John Smith or however he's got it set up, I guess.  Sometimes I will get an email from his coworker, Larry Jones, but Larry's email is not [email protected], it's [email protected]
    When I look at that quickly, especially if it's truncated at the end, I don't realize it's not junk.  In my contacts, I have Larry's email, and I have the contact set as Larry Jones. How do I get it to display "Larry Jones" instead of "L123JoJo1941..."
    This works for phone numbers, so it should work for email, right? Like, if Larry calls me, it doesn't display the call as being from "(404) 555-6543," it displays as "Larry Jones."
    If this is easy to do, and I'm missing it, please point me in the right direction. Thanks!

    No, it will appear in your Hub as the user has it formulated in their mail server or setup.
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Change field from read only and override calculation based on radio button

    Hi,
    I have a form in which one of the fields has a simple sum calculation and is set to read only so the user can't change it as it sets a print amount as well.
    But if one of the radio buttons is ticked there is a chance that the print amount needs changing but it can be different based on a few other options so I have managed to set the field so the user can edit it depending on an option but the calculation that sets the value overrides what the user enters. I would like to know if it is possible to change this?
    I use
    this.getField("Quantity_Boxes").readonly = false;
    So the user can edit the field when they select the radio button 'yes' under Mesh_b
    and
    this.getField("Quantity_Boxes").readonly = true;
    So the field goes back to read only when the user selects the 'no' under Mesh_b
    and in the Quantity_Boxes field I use:
    Quantity_Curtains / csn
    Just as a simplified division sum with the decimal places set to 0 so a whole number appears.
    csn is just a hidden field that has an amount set depending on the size of curtain.
    Thanks,
    Bruce

    I have found a solution but caused another problem (well more of an irritation than a problem)
    I have made it so the can field throws a dialogue box asking how many of the item fit into a box, the only problem is that the dialogue box will appear more then once.
    For example I have made a new size know as bespoke and when I select that size and hit return the dialogue box pops up which is fine but when the amount of the product is changed it throws the dialogue box again. I guess this is because the calculation has to be run again but is there anyway of stopping this?
    Here is the code I use in the can field which defines how many curtains are in the box and is used to calculate how many labels need printing out.
    if(this.getField("SizeDrop").value=='LG'){
    event.value = "5"
    } else if (this.getField("SizeDrop").value=='ST'){
    event.value = "8"
    } else if (this.getField("SizeDrop").value=='ME'){
    event.value = "10"
    } else if (this.getField("SizeDrop").value=='SM'){
    event.value = "15"
    } else if (this.getField("SizeDrop").value=='BE'){
    var resp = +app.response("Enter the amount of curtains in a box","","1");
    event.value = resp
    } else {
    event.value = " "
    Thanks,
    Bruce
    EDIT:
    I have found that the dialogue box will appear every time something is changed on the form (even while in the editor as well)

Maybe you are looking for

  • BI Content - Install Roles (ACGR)

    Hi BI experts, I am currently administering security for a BI 7 system and I have a quick question regarding BI Content (Object Types). Recently, I ran the transaction RSA1 -> BI Content -> Object Types and there is a type called "Role - ACGR".  I no

  • Dvdsp build message?

    "The Build Location folder contains a HVDVD_TS folder(HD DVD content).  You must remove the HVDVD_TS folder from the Build Location in order to proceed with Build/Format of a Standard DVD project." ..........any help on how i change this?

  • Acrobat Pro 9.4.5 digital signing, menu gray but properties says allowed

    I have a document that had the signing menu gray/disabled. I tried going to Advanced->Security->Remove Security. The dialogue said "You Cannot change security on this document because the document enables extended features in Adobe Reader. You can sa

  • Dynamic Diretory Configuration

    HI Experts, I have one requirement that i have to sen the Orders data from R/3 to File using Idoc adapter but at receiver side i need to create 3 different directories under one business system i.e IF E1ADHDR/E1STATE/E1PRTOB/ZGPSUB/BULO = '01' THEN c

  • HT2213 Mac Mini (mid 2010) interrupted firmware update. I cant recover

    Mi Mac Mini (mid 2010) only blinks rapidly, no slowly, the apple logo and progress bar show up, the bar blinks twice and the mac mini shuts off. I can eject the CDs turning on and pressing the eject key, so i think some BIOS is there... Im trying Mac