ISU-EDM Profile Value Import

Hi all,
While importing profile values from MS-Excel file (in transaction "Change profile header") the system is giving error "Error Importing Date, Check import file". I would like to know if any specific date format, different than exported file, is to be used. How do we import the profile values for test purposes i.e. without using BAPI/IDoc?

Hi,
If the format in SAP is dd.mm.yyyy, you should also be having format dd.mm.yyyy in your OS. If your OS is Windows, then under Control Panel, you have to make the necessary changes under u201CChange the format of numbers, dates and timesu201D.  This is likely to solve your problem.
With thanks & regards,
Vinodh

Similar Messages

  • EDM Profile values

    Hi all,
    Could someone tell me what is the industry standard of profile values under Profile value Category "Quantity", whether it is readings or consumption.
    As of now when we compute the billed quantity it is calculated as sum of the profile values, indicating the profile values are consumption values.
    Are there also scenarios where meter readings (instead of consumption) are used in profile values. If so what is the procedure to compute the consumption
    With thanks & regards,
    Vinodh

    Profile values are typically consumption (electricity or gas, resp. kWh and m3) or demand (electricity, kW).
    I have not seen a scenario where the profile contained the readings. However if the meter (or metering system) would provide this information on a periodic time basis it would be no problem to store it in a profile.
    Consumption would then have to be derived in the RTP interface from the readings in the period billed.

  • EEDM01 EEDM02 Profile values Enhancement

    Hi,
    I was looking on a way to enhance the EDM Profile values transactions (EEDM01/02) by adding some extra fields in the ALV showing the profile values.
    Since I haven't found any Screen-exits or BAdI, are you aware about any solution to achieve that?
    Regards,
    John

    Check table EPROFVALSTAT that your profile values also have a status for the period you are looking at in EEDM02.
    If they don't then they won't show up.
    If there is no status then something must go wrong in your upload. Check the STAT in the PROFILEVALUES parameter in your BAPI call. Make sure it is translated from external to internal status in customizing.

  • EDM Report to generate profile values (synthetic profile)

    Hi profis!
    I want to create a report to generate synthetc profile values in IS-U/EDM.
    Can you suggest a function modul or an object type and accordingly method/methods?
    thanks a lot!
    regards
    Reiner

    Hello,
    The following function module  ISU_S_SYNPROF_GENERATE_ALL should be of help...however be aware it has status "not released" for customers
    Regards
    Olivia

  • De-allocating EDM Profile of an Interval Meter attached to an installation

    My dear friends, I need sincere help from you .
    This is an ISU requirement on which ABAP/functional  suggestions are required.
    I have an installation with an interval device installed to it.
    We need to do full removal of this installed device by eg32.
    The interval meter is having EDM Profile attached to it. Before doing full removal of the device from the installation using EG32,
    we need to de-allocate the EDM Profile attached to this interval meter. Manually this is done by using transaction code - EEDM04
    but we need to do deallocation of profile using ABAP code.
    We need your help in this regard. Could you suggest ISU function modules that could be used to do the deallocation of the EDM profile from the interval Device/Meter.
    Your help is really needed and appreciated!
    Thanks,
    Rohit

    I think function module ISU_S_PROFASS_CHANGE might be useful.
    Isnt't it an option to prorate the profile allocation on device removal?
    You can set system parameter PRORATEPRO for this in customizing of device management:
    PRORATEPRO (Limit Prof. Alloc. for Rem./Repl./Mod./Chnge to Logical
    Reg.)
    During device installation/replacement/removal or when changing the
    logical register number, you can use this parameter to control
    whether the allocations of the profile to the register are limited.
    Edited by: evolderen on Apr 15, 2010 8:23 AM

  • Remove EDM Profile from Interval Meter of an installation-Device Management

    My dear friends, I need sincere help from you .
    I have an installation with an interval device installed to it.
    We need to do full removal of this installed device by eg32.
    The interval meter is having EDM Profile attached to it. Before doing full removal of the device from the installation using EG32,
    we need to de-allocate the EDM Profile attached to this interval meter. Manually this is done by using transaction code - EEDM04
    but we need to do deallocation of profile using ABAP code.
    We need your help in this regard. Could you suggest ISU function modules that could be used to do the deallocation of the EDM profile from the interval Device/Meter.
    Your help is really needed and appreciated!
    Thanks,

    I think function module ISU_S_PROFASS_CHANGE might be useful.
    Isnt't it an option to prorate the profile allocation on device removal?
    You can set system parameter PRORATEPRO for this in customizing of device management:
    PRORATEPRO (Limit Prof. Alloc. for Rem./Repl./Mod./Chnge to Logical
    Reg.)
    During device installation/replacement/removal or when changing the
    logical register number, you can use this parameter to control
    whether the allocations of the profile to the register are limited.
    Edited by: evolderen on Apr 15, 2010 8:23 AM

  • IDOC date interval for Profile values during Summer/winter change

    Hi SDNers,
    I have a Mail-to-IDoc Scenraio, where I need to import profile values with 15 min time intervals. Everything is OK except for the date of Summer/Winter change. For example the normal day has 96 intervals where the Day during which Summer->Winter time change occurs must contain 100 intervals. I tried the combination in various ways but in vain. I recieve SQL dup rec error or Invalid date error. Any suggestions how to implement this in an efficient manner.
    Thanks in advance
    regards
    satish

    Sachin,
    No offence intended, but , it would be helpful if you can also tell us how you arrived at the soltuion.
    Regards,
    Bhavesh

  • EDM profile uploading

    Hi,
    I Ihave developed a report to upload edm profile at an interval of 15 minutes.I am fetching installatiion number ,date ,unit of consumption and the consumption values at 15 mins interval from a text file.My report is inserting values to the database table EPROFVAL15,but while iIam trying to see the profile values through the transaction EEDM02(by giving the installation number and selecting a profile) then m unable to see the values.Can anyone tell me the cause of the above problem .
    I have used the function module ISU_DB_EPROFVAL15_UPDATE  to insert values.Is this problem related to the time zone.actually in the database the profile values should  get inserted for a profile 5.30 hours before(for example: on 30.06.2010 for profile no:50
    consumption value for time 00:00:00 should get stored on 29.06.2010 at 00:18:30).
    regards.
    pratibha

    need to  ask  some other  question  so  winding up things replies are always welcome

  • EDM profile header

    hi friends
        i have got an  issue in  profile creation in  edm
    when i  tried to  create profile header t code eedm06 i  selected the interval length as price but  its asking  for unit  of measurement..actually  it must  ask only  for currency..
    but its asking  for both currency  and unit of measurement
    can any 1 help me with this????
    regards
    prince

    hi friends
      atlast the error has been  solved.for this error u  need to  assign the energy and price in  sproedmprofile managementdefine units of menasurment
    here v  need to  maintain the diviosn  and profile value category  with kwh
    in my case it was
    electricity  price and energy  was the data entered in that  screen
    and it  worked
    thanks and regards
    prince

  • EDM Profile upload and Timezone

    Hi friends
    When importing profile values using std BAPI, I am facing a problem, my time zone is EST ( UTC-5) but the data from interval (CMEP format) meter is in UTC thus a value of 05:00:00 in the file is actually 00:00:00 in the system. Now it is becoming difficult to match the data against the local time ( EST) both in Table and in display during profile value upload
    I have tried changing the time zone in the system and in user profile. can you please help
    Thanks
    joy

    Hi Roy,
    Use FM ISU_DATE_TIME_CONVERT_TIMEZONE. On table TTZZ, you have the all existing Time Zones.
    Here a Test for you case with FM test interface.
      Import Parameters               Value      
      X_DATE_UTC                      02.10.2008 
      X_TIME_UTC                      05:00:00   
      X_TIMEZONE                      UTC-5                                                                               
    Export Parameters               Value      
      Y_DATE_LCL                      02.10.2008 
      Y_TIME_LCL                      00:00:00   
    Hope that this is exactly what you mean.
    KR,
    AAL!

  • Table for EDM Profile with Installation or Device numbers

    Hi
    Can anybody answer Table for EDM Profile with Installation or Device numbers?
    Thanks in advance.
    DGR

    Hello,
    You allocate the profile to a register so you want to have your logical register number.
    If you have the equipment number you could go to table ETDZ or call FM ISU_DB_ETDZ_SELECT and fetch the registers.
    If you want to see the table of profile allocations you can check table EPROFASS.
    If you use IS-U-EDM the tables which contains informations about profile values are EPROFVAL*...
    Hopefully some of this infomation is useful for you.
    Regards
    Olivia

  • ISU EDM cookbook

    Hi,
    Where can I find ISU-EDM cookbook ? Does anyone has the link?
    Thanks in advance.
    w
    Moderator note - thread locked - no research.

    HI,
    What is EDM?
    EDM is a special module part of SAP Utilities Industry Solution to manage the energy data of a utility company such as load shapes and standard load profiles. Based on this data we can make Real Time Pricing and Settlement.
    What is EDM Repository?
    EMD has a Repository where all types of energy and energy-related data can be managed especially measurements in euidistant time interval ( 15 minutes, 30 minutes, 1 hour, 1 day).
    What is Real Time Pricing?
    Real time pricing is special type of billing based on load shapes. Basically we can bill each time interval (15 mins, 30 mins, 1 hour, etc) with a different price, for example the spot price. This type of billing is used for really big customers which have huge energy consumption.
    What is Settlement?.
    Settlement in EDM means settlement of energy quantities. All input data required for settlement comes from EDM Repository. For example we can calculate the total load of a grid and send it to a market partner.
    EDM module is implemented by all big utility companies to help them achive better energy data management, to forecast the consumption and to settle the energy quantities supplied trought a utility network.
    Regards
    Sreedhar Reddy

  • How to change the profile value in the pl/sql code without making change in the database

    How to change the profile value in the pl/sql code without making change in the database.

    I have program ,where if the profiles 'printer and nunber of copies ' are set at the user level, by default when the report completes the O/p will be sent to the printer mentioned in the set-up. but what user wants is
    if these Profiles are set for the user running this program automatic printing should not be done.

  • How to create a profile value at user level programatically

    Dear all,
    I want to create a profile value at user level programatically, I refer to the developer guide and try to use fnd_profile.put() to create a new value.
    But I find out the value is just created in session level, not be inserted into base table.
    So is there anyone know how to realize this function in PL/SQL?
    Any idea is appreciated.
    Best Regards,
    Kenny

    Check Note: 364503.1 - How to Set a System Profile Value Without Logging in to the Applications
    https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=364503.1

  • Partner profile value for XI system

    I got a outbound message with partner profile value as
    <SAP:SNDPOR>XIDEV</SAP:SNDPOR>
      <SAP:SNDPRN>XiALE01</SAP:SNDPRN>
      <SAP:SNDPRT>LS</SAP:SNDPRT>
    Where do I go and change the SNDPRN value in SLD? or is it SLD I change it. SAP R3 is looking for sender partner profile in caps. How to change this value in XI
    thanks

    Hi,
    Please update few things.
    1. Since it is an outbound from XI into another R/3 machine, I would first suggest you to check IDOC posted in R/3 which has an error message tagged to it. This is applicable only when Message went from XI into R/3 and we see an error in the SXMB_MONI as RFC destination not found etc.,.
    In such a case, IDOC error message with 53/51 etc, will post an error message like "SENDER NOT IDENTIFIED". This SENDER and RECEIVERs can be seen in the CONTROL RECORD of the IDOC.
    From R/3, use transaction WE02/WE05 and locate your IDOC (normally in the OUTBOUND folder on left, look at last few messages which have RED TRAFFIC SIGNAL and match the partners).
    To resolve this, create the RFC PORT first. XIDEV using WE21 referring to your XI client. The prerequisite for this is to have a RFC destination already created to port XI and a logical system (BD54 transaction).
    Create a Logical System (Business Partner) of type LS using WE20 and (Logical system you have created or identified in BD54) should be configured as you want.
    This should resolve your issue.
    2. If the issue is with XI and message is not seen in R/3, make sure you have assigned proper logical system in the SLD for your technical landscape. If this is pointing to a different logical system, then probaboy you may want to change to suitable logical system.
    Suggest you to look for the definitions using SM59 and IDX1 in R/3.
    Hope this answers, please let us know your findings.
    Thanks,
    Srini.

Maybe you are looking for