Measuring Point BDC error

Hi,
When I am uploading data for IK01(Create Measuring Point), Lower Range limit value in additinal data is always showing zero. During uploading(with processing mode A),whatever data given in flat file it's showing on the screen. But after saving and checking in IK02  the Lower Range limit value in additinal data is showing 0. Please help in resolving this issue.
data: begin of record occurs 0,
data element: IMRC_MPOTY
        MPOTY_001(003),
data element: IMRC_MPTYP
        MPTYP_002(001),
data element: EQUNR
        EQUNR_003(018),
data element: IMRC_PSORT
        PSORT_004(020),
data element: IMRC_PTTXT
        PTTXT_005(040),
data element: ATNAM
        ATNAM_006(030),
data element: IMRC_DESIC
data element: IMRC_DECIM
        DECIM_011(002),
        DESIC_007(022),
data element: IMRC_PSORT
       PSORT_008(020),
data element: IMRC_PTTXT
       PTTXT_009(040),
data element: ATNAM
       ATNAM_010(030),
data element: IMRC_DECIM
       DECIM_011(002),
data element: IMRC_DESIC
       DESIC_012(022),
data element: IMRC_MRMAC
        MRMAC_013(022),
data element: IMRC_MRMIC
        MRMIC_014(022),
data element: IMRC_UNITM
        UNITM_015(006),
data element: IMRC_PSORT
       PSORT_016(020),
data element: IMRC_PTTXT
       PTTXT_017(040),
data element: ATNAM
       ATNAM_018(030),
data element: IMRC_DECIM
       DECIM_019(002),
data element: IMRC_DESIC
       DESIC_020(022),
      end of record.
LOOP AT RECORD.
perform bdc_dynpro      using 'SAPLIMR0' '1110'.
perform bdc_field       using 'BDC_CURSOR'
                              'IMPT-MPTYP'.
perform bdc_field       using 'BDC_OKCODE'
                              '/00'.
perform bdc_field       using 'RIMR0-MPOTY'
                              record-MPOTY_001.
perform bdc_field       using 'IMPT-MPTYP'
                              record-MPTYP_002.
perform bdc_field       using 'EQUI-EQUNR'
                              record-EQUNR_003.
perform bdc_dynpro      using 'SAPLIMR0' '5110'.
perform bdc_field       using 'BDC_CURSOR'
                              'IMPT-ATNAM'.
perform bdc_field       using 'BDC_OKCODE'
                              '/00'.
perform bdc_field       using 'IMPT-PSORT'
                              record-PSORT_004.
perform bdc_field       using 'IMPT-PTTXT'
                              record-PTTXT_005.
perform bdc_field       using 'IMPT-ATNAM'
                              record-ATNAM_006.
perform bdc_field       using 'RIMR0-DESIC'
                              record-DESIC_007.
perform bdc_dynpro      using 'SAPLIMR0' '5110'.
perform bdc_field       using 'BDC_CURSOR'
                              'RIMR0-DESIC'.
perform bdc_field       using 'BDC_OKCODE'
                              '=ADPT'.
perform bdc_field       using 'IMPT-PSORT'
                              record-PSORT_004.
perform bdc_field       using 'IMPT-PTTXT'
                              record-PTTXT_005.
perform bdc_field       using 'IMPT-ATNAM'
                              record-ATNAM_006.
perform bdc_field       using 'IMPT-DECIM'
                              record-DECIM_011.
perform bdc_field       using 'RIMR0-DESIC'
                              record-DESIC_007.
perform bdc_dynpro      using 'SAPLIMR0' '6110'.
perform bdc_field       using 'BDC_CURSOR'
                              'RIMR0-MRMIC'.
perform bdc_field       using 'BDC_OKCODE'
                               '=BU'."'=NEXT'.
perform bdc_field       using 'RIMR0-MRMAC'
                              record-MRMAC_013.
perform bdc_field       using 'RIMR0-MRMIC'
                              record-MRMIC_014.
perform bdc_field       using 'RIMR0-UNITM'
                              record-UNITM_015.
perform bdc_dynpro      using 'SAPLIMR0' '5110'.
perform bdc_field       using 'BDC_CURSOR'
                              'IMPT-PSORT'.
perform bdc_field       using 'BDC_OKCODE'
                              '=BU'.
perform bdc_field       using 'IMPT-PSORT'
                              record-PSORT_004.
perform bdc_field       using 'IMPT-PTTXT'
                              record-PTTXT_005.
perform bdc_field       using 'IMPT-ATNAM'
                              record-ATNAM_006.
perform bdc_field       using 'IMPT-DECIM'
                              record-DECIM_011.
perform bdc_field       using 'RIMR0-DESIC'
                              record-DESIC_007.
perform bdc_transaction using 'IK01'.
endloop.
Thanks
K Srinivas

Do the recording again for the data you have, and see whether the data is being written again after some screen navigation (i.e lower range values written again ) in the recording .
Check whether any navigation takes place from the point you write data to another place and you return back to the same place ,if that is the case you need to write the data again

Similar Messages

  • Measuring Point Downloading Error

    Hi
    I'm getting error in downloading Measurment Points data.
    When I'm executing the report "RALM_ME_MEASP_FULL_DOWNLOAD_SD", it is shown  that "5 Measurement Points have been transferred", but in table "MEREP_DELTABO", no new record is displayed.
    In SM37, in Log its showing ->waiting-> "Frontend unavailable".
    What steps to follow?
    Regards.

    Hi Konchada,
    well, it seems you are missing some config steps. The server driven setup can be a little tricky if you do it the first time. Please have a look into this document, it describes the necessary steps really well:
    https://www.sdn.sap.com/irj/sdn/nw-mobile?rid=/library/uuid/818ac119-0b01-0010-ba8b-b6e3f3490a63
    Hopefully that helps to solve the issue.
    Regards,
    Oliver

  • Functional location in Measuring Point and while creating M.plan or differe

    Hi,
    we found that functional location in Measuring point and M.plan functional location Measuring point are differrent, how to restrict that one ,we need automatically flow of functional location from measuring point to Maintenance plan.
    --Ganesh

    Hi,
    If you created the Measuring Point for the selected FL, then that measuring point will be populated automatically. If you have more than one measuring point, then you can select using Possible entries option.
    In this case, I think its not possible to restrict with configuration.
       IPRM0004 Maintenance plan / item: Customer check for time "SAVE"
    Use this user exit, while saving check for the functional location for the selected measuring point & give error message.
    Use tables IMPTT to get Object Number of FL. Use IFLOT to get the FL.
    Regards,
    Maheswaran.

  • Measuring Point Status.

    Dear All Consultants,
    I have scenario for warranty services, so I define master warranty with to conditions “years - kilometer reading”.
    The problem is while assigning master warranty to equipment master system gives me this error {could not determine the status for measuring point 000000000212 at date 11.06.2007      
    Message no. BG212   } 
    Why this message appears and how to solve it.
    It is only warning message but it assume that the warranty expired.
    Waiting your kindly replay.
    yasser.

    Hi,
    Please refer the link below
    http://help.sap.com/saphelp_46c/helpdata/en/5a/3efb377409bd5ae10000009b38f889/frameset.htm
    as you might have not defined first counter.
    Enjoy SAP…
    Don’t forget to give points if its useful ans.
    Namskar
    Ketan Dave

  • Cannot create "Digital" measuring points on Work Manager 6.0

    Hi All,
    I am attempting to create "digital" i.e. Pass/Fail measuring points in Work Manager 6.0. I can enter readings as shown below but when I execute a sync, the error message below is shown:
    I can use the same measuring point in SAP via IK11 as shown below to create a measuring document using valuation code only. However, the Work Manager requires a numeric characteristic to be added and the "no reading" checkbox to be ticked.
    Any help would be greatly appreciated.
    Thanks,
    Jonathan

    Hi Michael,
    I tried setting it up with just the two values (0-fail and 1-Pass) and I'm still running into errors. If you could take a look I'd be grateful.
    Set up code group with two values:
    IK11 allows just the valuation code to be used:
    On the device:
    As far as I can see this should work but it still creates the same error as previously. Ideally it should work as IK11 and allow the user to select from multiple valuation codes but it appears to still require a characteristic.
    One option I tried is to assign a characteristic in addition to the the valuation code and use a 0 reading. This works but is a "workaround" solution in comparison to IK11.
    Any help would be really appreciated.
    Thanks,
    Jonathan

  • Update Measurement Points on Functional Locations

    Hello Experts,
    I need create a custom program to update (add/delete/change) the measurement point's POSITIONS on functional locations. Basically the users want to clean up the functional locations which have some wrong data in them. Since I am very new to this functionality area, Can anybody please let me know - Is there a FM/Bapi to update the Measurement Point Positions on Functional Locations?
    I appreciate your help.
    Thanks.
    Edited by: sey ni on Mar 7, 2011 4:49 PM

    I think I will have to write a BDC on IK01/IK02 transactions. Not sure, if we have a better solution.

  • Measuring Point Description Change-MassChange

    I have several (hundreds of ) Measuring points which i need to change .The fields to be changed include the Measuring position    and measuring descriptions. Since its a time consuming process to change individual record, can some one suggest any mass change transaction in PM with which i can achieve this changes without much time as in case of individual changes.
    Please suggest some direct method in order to avoid any BDC or LSMW.
    Thanks
    Murad Shaikh

    HI  Murad
    As such there is no standard T code for carrying out mass changes for measuring points except list editing (IK08) through which you can do it by selecting one by one. Since the fields you wants to change are free text type & will vary from one measuring points to other its not logical also. Better to do it through LSMW using recording IK02 its very easy & will take 10min to create one LSMW.
    Shakti

  • Measuring point update by production order confirmation

    Hi friends,
    I created a prt as equipment and assigned it to the routing. I created a production order and when i confirm the same i am getting following error as:
    Document MeasUnit has a different dimension to the characteristic unit
    Message no. IR071
    Diagnosis
    The measurement unit on creation of the measurement document must have the same dimension as the measurement unit of the characteristic of the measuring point.
    In this case, the measurement unit % does not suit the character unit EA of the measuring point 103.
    System Response
    Processing will not be continued.
    Procedure
    Use the possible entries help.
    Please suggest the solution.

    Hello Sir(s)
    i have gone through entire post for the subject related to measuring point auto update from production order confirmation.  I have tried the same but i dont know what i am missing.
    if i put some value like 1 or 2 and appropriate UOM then only my measuring document is being updated with the same value not with the actual confirmed quantity..  i have already maintained standard formulla in prt view.
    my basic requirement is to get actual value of produced quanity as counter update. means if 20 pieces have been produced and confirmed in co11n, then counter must bhe updated with the value of confirmed quantity.
    please advice what value should i put as usage in routing master to get actuall counter update.
    Will Highly appreciate your quick reply.
    Snapshots
    Regards.
    Mohammad.

  • Measuring point as counter mass maintenance

    Hi,
    I have created some 500 equipments through BDC. But I forgot to put a tick (X mark in template) against field u2018Indicator to Show that Measuring Point Is a Counter.
    How to put a tick on that field in mass?? Other wise I will have to go to T code IE02 500 times and put a tick manually.
    Pls guide.
    Regards.

    Hi Dear,
                 You can use the LSMW for the T-Code IE02, Recording Methord.
    That can serve your Purpose.
    Regards,
    Yawar Khan

  • Measuring point  does not exist

    Hi,
    I am facing problem in pi sheet where in co54 while sending the process msg i am getting the error
    "Measuring point  does not exist"
    "Destination YI16 COCI_MEASUREMENT_DOC_CREATE cannot process the message"
    "Message is not sent to any destination"
    Can any body help....
    Rajsekhar

    Hello
    Check the link below for the info you can gather using the Container Variables.
    Creating Alert Categories 
    http://help.sap.com/saphelp_nw70/helpdata/en/d0/d4b54020c6792ae10000000a155106/content.htm
    Regards
    Mark

  • Measuring point External Number range

    Dear Masters,
    I am trying to create the external number range for one of my measuring point type. Is it not possible to do so? If no why? If yes how?
    Thanks to all in advance.

    Hello Vaibhav,
    I have already followed the steps given by you only I cannot find the assignment of measuring point category to the number range. I have also done the number range assignment for equipment and functional location but there it exists here it does not.
    It is also showing me the error of external number while creating the new measuring point. Please do guide about the assignment to the number range.
    Thanks again.

  • BDC error in Upgrade proj.

    Dear all,
                  I am on a upgrade proj. from 4.5 to ECC 6.0. when i check an object I got a kind of BDC error like  'ERROR TYPE  ==> 4      ( SCREEN MISSING IN TARGET SYSTEM )'  along with program name and  screen number. please advice me in solving  this error.
    Thanks.
    Naresh.

    Hi Naresh,
    That one of the task when you go for an upgrade.
    You have to redo the recording part again for all BDC programs
    Try to change it to BAPI if you have suitable BAPI.
    Reward points if helpful
    Thanks
    venki

  • Measure Period with error out.vi

    I am using LV6.0. Can Measure Period With Error Out be found in the functions panel? If not where it is? If not there can it be imported into LV6.0?

    labview1958,
    Are you looking for a specific VI called Measure Period with Error Out.vi or are you asking about any general function that can be used to measure the period of a signal and includes error handling? If you are looking for a specific VI, I'm unaware of it, so I won't be much help there. If you're looking for any function to do it, have you looked at the VIs called Measure Pulse Width or Period.vi or Pulse Width or Period Meas Config.vi? They are located in the Data Acquisition>>Counter palette. The Measure Pulse Width or Period.vi does not include error handling, but it would be extremely easy to add it. The Pulse Width or Period Meas Config.vi DOES contain error handling, but it only configures the counter to measure the period, it doesn't actually measure it. These, of course, are for TTL signals coming into your hardware device. If you are reading waveform data from a file and want to calculate the period of that signal, these won't do much for you. So what exactly are you wanting to take a period measurement on, a physical signal, physical signal data points from a file, or some other method?
    Tyler S

  • Accepting date as a measuring point

    Please guide as to how does one accept date field as an input in measuring points.Have made a characteristic with date format,yet while creating a measuring point with the said characteristic , displays an error
                                     " Only characteristics with a Numerical  format can be used "
    awaiting an early reply,

    Hi pshthecoolest ,
    You cant declare DATE with Date format as Characteristics , as per Std SAP.
    Work around will be Create Char CT04 DATE , with Numeric format with Template  (8), assign appropriate unit of Measurement , that you need to create separately t code CUNI.
    But above all why you required to put reading as a Date in measuring point ?
    Riyaj
    Edited by: riyajmaner on Feb 8, 2011 12:51 PM

  • IE02 not able to display class overview & measuring point/counter tab,

    Hi Dear,
    I am not able to display class overview & Measuring point/counter tab in T-code IE02.
    But it is display in IE01 & IE03.
    Kindly suggest

    Mayursinh Dayatar,
    Its probably an authorisation issue.
    Are there any error messages??
    PeteA

Maybe you are looking for