Dear All,
I am trying to measure 4 waveforms from a signal generator, I am
transferring the waveforms through a shared variable on my host.vi from
the target.vi. But the signal is not coming as it is. I am attaching
some screen shots, I have tried changing the parameters of the shared
variable but it does seem to help. I am also confused about the options
that become active when click theI check box  of the "use
buffering" option.
The screen shots are zipped.
Thank you very much.
Sincerely,
Munir Afzal Bhatti.
Attachments:
untitled4.zip ‏168 KB

Dear Nick ,
I am sending the program in zip format including the files of the
waveforms that I have saved. I used the select signal express VI but it
does not seem to select the different waveforms. There are two .dat
files. One contains  all  the  4 channels and the other
contains  1  channel.
Thank you for the really fast response.
Sincerely,
Munir Afzal Bhatti.
Attachments:
munir4channels.zip ‏359 KB

Similar Messages

  • How do I install Shared Variable Engine on a computer not having Labview?

    Hi,
    I am trying to communicate with a real time program running on Compact RIO through shared variables. I have an executable of the host vi that runs on a Windows computer. If I run this executable on the computer that has Labview installed on it, it functions fine. I want to be able to run this executable on a computer with Labview. I learned that I have to first install Shared Variable Engine on this computer.
    How do I do that? Where to install it from? Is that going to be sufficient? Please provide the solution or point me to the right resources.
    Thank you.
    Anmol.

    When you built the installer for the executable, you have a choice to include additional installers. One of them is the "NI Variable Engine". Have you tried including it?
    LabVIEW Champion . Do more with less code and in less time .

  • Shared Variable Engine Error Handling

    I have a HMI system that connects through shared variables to an OPC Server. I have encountered problems with Variable Engine, and a problem with tagger which I don't know anything about. I checked OPC Server to see  ifit's installed properly and the items status is good, and the server's connected. I tried to restart the shared variable engine service but it doesn't reply. When I monitor variables there's no connection. I used Alarm&Event query.vi in my application and then encountering tagger error, server connection failed. How could I handle these errors? 
    I appreciate any help.

    I've created Bindings to OPC items I want to read/write through an OPC Client instance, bound front panel objects to these shared variables, deployed the entire library and run the VI.
    All the connections were true (green PSP-LED. through the Monitor Variables all the variables and OPC items of client instance had good quality and right value.
    All the variables were configured to log data and alarms.
    Configuring the library for a data base through it's DSCsettings:database, I used Historical VIs (Read trace,… ) to retrieve data from citadel and they worked properly. I used Alarm & Event Query.vi to retrieve alarms from citadel, the VI encountered this Error:
            "Some part of tagger encountered a problem and should be closed"
    After that the entire connections failed (PSP-LEDs goes red) and the I/O Engine couldn't be restarted and shows this Error:
                 "Could not stop the National Instruments Variable Engine Service on local computer.
                  Error 1053: the service did not respond to the start or control request in a timely fashion."
    And the variable monitor dosen't show any library and variables.

  • Do I need to set host side shared variables to RT FIFO?

    Hello there,
    in my application a LV host application communicates with compact RIO through shared variables. On cRIO i have some shared vars with RT FIFO enabled. On host side for those vars which are bound to cRIO i did the same. Is that neccessary?
    In general I am confused about shared variable settings on both sides, for example when I want network buffering. Do I set buffering on RT side or on PC side or on both, what is the difference?
    regards
    Thomas

    Dear Thomas,
    thank you so much for your post. The shared variable with RT FIFO enabled works the same as the RT FIFO functions on the RT functions palette. The RT FIFO is for communication between the higher priority loop and the normal priority loop. You can see it like this; if the shared variable with RT Fifo enabled is network published there is a communication loop (hidden) which publishes the shared variable to the network port of the cRIO system. The RT FIFO option is only for the communication between your high priority loop and this hidden loop. The hidden loop is executed when the higher priority loop is idle. Again I speak about hidden loop just to create a clear picture.
    So for your PC side no RT FIFO is needed. Please notice that by using shared variables you can lose data; for example the cRIO publishes the data faster then your PC can read the data; you will lose data points. Shared variables are based on UDB, you can see it like a radio station which is transmitting. It doesn't matter if people are listing to the radio station. Use the TCP functions (for example theSTM library ) or the network stream API if you don't want to lose data.
    Please let me know if you have any further questions,
    Best regards,
    Martijn S
    Applications Engineer
    NI Netherlands

  • CRIO and ni 9234 modules not working or communicating through fpga with accelerometers, fpga connected to real time application which is also connected to shared variables linked to modbus slave

    Hi,
    I have a compact rio which has a 4 way chassis attached to that chassis is three ni9234 modules they are linked using fpga to a real time application then using shared variables in the low speed loop that are linked to a modbus slave to communicate with dcs, the ni 9234's have accelerometers connected to them with iepe ac coupled option on the c modules, my problem is the real time application seems to be running okay even when power loss occurs it restarts with no problem and the fpga writes to the portable hard drive bin files fine but without a accelerometer connected I get low noise readings as soon as I connect a accelerometer to any one of the 10 outputs it just goes to a fixed number (0.03125) as soon as disconnect it again it reverts back to reading noise, I have run a scan on the modules and only get a spike when I connect or disconnect the accelerometer, I have tested the voltage at the pins of the module and I get 22 volts dc which makes it more likely that the hardware is not the problem but a software is maybe causing this to hang-up, I attach project and files for your perusal. I also carried out a new project which in scan mode directly linked the module input to shared variable and the same scenerio again. Help would be much appretiated. 
    Many thanks
    Jason
    Solved!
    Go to Solution.
    Attachments:
    logger 2plusmodbus2.zip ‏679 KB

    Whren using waveform acquisition with the 9234s we recommend the following FPGA and RT template.
    http://sine.ni.com/nips/cds/view/p/lang/en/nid/209114
    it can be extended as a data logger with:
    http://zone.ni.com/devzone/cda/epd/p/id/6388
    or using shared variables combined with scan engine
    http://zone.ni.com/devzone/cda/tut/p/id/9851
    The FPGA in all of these, as well as the RT framework have been used successfully by 1000s of users.  I would recommend giving these a try. 
    Preston Johnson
    Principal Sales Engineer
    Condition Monitoring Systems
    Vibration Analyst III - www.vibinst.org, www.mobiusinstitute.com
    National Instruments
    [email protected]
    www.ni.com/mcm
    www.ni.com/soundandvibration
    www.ni.com/biganalogdata
    512-683-5444

  • How to use shared variables to measure analog input

    Dear All,
    I am using Real time remote system. I am using PXI-6259 card, PXI-8184RT controller and PXI-1031 Chassis.
    I want to use shared variable to measure and analog Input(voltage) from
    an analog input Channel.  I tried  attaching it  with the physical
    channel using the bind to source option but it idoes not seem to work,
    can any one give me any suggestions?
    Screen shot  of this is available.
    I tried using the Acq and graph example and deployed it to the RT but
    the Sine wave I input in the measurement channel  becomes highly
    distorted when I see it in the host.vi, there is also a Screen shot of
    this also. Is there any other option.
    What am I doing wrong? all suggestion are highly welcome.
    Thank you.
    Sincerely,
    Munir Afzal Bhatti.
    Attachments:
    SV2.jpg ‏2305 KB
    SV3.jpg ‏2305 KB

    You will have to give us the whole picture. What is your client computer; a PAC, desktop etc? What are you running on the client computer; a VI or an executable? Where are you going to deploy your library? On the host machine or the client machine?
    If I assume that you are running a VI on the client machine and are depolying the library on the host, all you have to do is to create another shared variable and bind it to the variable on the host machine. You can do this by checking the Bind to Source option when creating the variable and browsing to the network item in options. Be sure to have the library deployed on the host side before you attempt to do this otherwise you won't be able to find the variable.
    Adnan Zafar
    Certified LabVIEW Architect
    Coleman Technologies

  • Does a network published shared variable drop the waveform attributes?

    I have the analog input source for a waveform on one NI chassis. The trigger to begin the trend is on another NI chassis. Both of them feed data to a remote Windoze host. I would like to know how I can pass the waveform attributes, ie. Plot Names from the source machine to the Windoze host using a network published shared variable. I am using LV8.0. My two remote chassis are both running RTOS.
    I can see that when I set up the DAQ assistant and named my aquired signals, that these names are passed to a waveform chart on the same block diagram. I can use them to update the Plot Names on my front panel. However, when I create an "Array of Double Waveform based" network published shared variable, and then read that variable from the Windoze host there are no attributes attached. The waveform shows up just fine.
    I would like to be able to have the attributes update the plot name when I change the plot. I will have about 20 plots and I only want to display them a few at a time. I also want the user to be able to select which one they want to look at.

    Hello,
    I think you posted the same question to another thread, received an answer, and have now moved on.  Anyway, the workaround to the problem is to peform flatten to string and unflatten from string operations on the waveform before and after sending it to the shared variable respectively.  See the attached screenshot for the specifics.
    I hope this helps!
    Best Regards,
    JLS
    Best,
    JLS
    Sixclear
    Attachments:
    Workaround Screenshots.JPG ‏206 KB

  • Shared Variable through the internet

      We have a remote site that is running LabView to record some data.  Currently we can log on to the computer using VNC (remote control software), we use a static IP address with a port number that connects to a gateway that uses port forwarding to get to the machine of our choice.  Doing that we have control of the whole computer, but the transfer of anything is slow and the screen refreshes about every 5 seconds or so using a low (64) color setting, using full color is almost painful.
      So the latest idea is to be able to send data from the remote system and display it or save it on a local system.  The idea would be that only data is being sent which should be faster since we would not have to worry about transfering graphics and other stuff.
      I have been playing with shared variables all day and searching the forums.  From what I have read it sounds possible, but I have not been able to do it yet.  I am wondering if there is a problem with the port forwarding.  I have tried tools > shared variables > register computer, but it has not helped.  Is there any good detailed instructions on how to use shared variables over the internet?  I do not have any VI's to share because I have been using the help vi's.

    Bryan,
    Let me know if I understand your problem.  You are trying to remote into a computer using VNC over some sort of network to gain access of a VI that is running on that machine.
    The problem is that the computer you are looking at is updating slowly.  Is the VI collecting the data returning the correct values at the correct rates?
    Have you thought about using Remote Front Panels?  If you are just trying to access another VI on a computer on the network, I would try this.  You may also want to check out the Web Services, which is new for 8.6.
    Have a great day,
    Justin Parker
    National Instruments
    Product Support Engineer

  • Shared Variable Engine on Windows PC w/o full install of LabVIEW

    I have the NI Developer Suite (8.20) and need some conformation before I get too deep in a project. 
    First of all, it is my desire to become very efficient on develop compiled executables with LabVIEW 8.20 as my NI Developer Suite license allows me to deploy these programs to any number of machines without facing copyright infringement.  I have been successful with this to a certain degree, but am still having problems in the testing stages of my application especially in cases where the hardware I am trying to target does not exist on my developing station.  If anyone can point me to white papers that would help me get the mindset to develop in this way, I would appreciate it.
    Onto the topic of this post:
    I am just scratching the surface of the shared variable interface that is available in LabVIEW 8.2.  My project involves two computers where both of them need to share variables back and forth from each other.  I've been reading everything I can get my hands on and I am having a hard time answering my unlying question: Is it possible for both of these machines to be running compiled LabVIEW programs and still manage the shared variables between them?  That is to say, can one of the machines have the Shared Variable Engine running on it as a Windows service, or compiled into my application executable.
    I've read that I can access shared variables from my compiled LabVIEW application through NI-PSP.  I am wondering what my limitations would be sans-LabVIEW installation other then the troubleshooting head ache you get from developing applications without direct access to the hardware.
    Thank you for your time and submissions.
    -Nickerbocker

    I am trying to get the "Shared Variable Client - Server" project example compiled so that both the server and client vi's can be run as executables on a standalone machine.
    I have created 3 build specifications:
    1. "My Server" which is the compiled EXE of the server.lvib.  Added that entire library to the source.
    2. "My Client" which is the compiled EXE of the client.lvib.  Added that entire library to the source.
    3. "My Installer" which is the installation package of the vi's and NI supporting software.  In the additional installers I have added:
     * NI DataSocket
     * NI LabVIEW Run-Time Engine 8.2
     * NI Measurement & Automation Explorer 4.1
     * NI Variable Engine
     * NI Variable Manager
     * NI-DAQmx 8.3
    Some of those are added for future needs.  Installed the package on my target machine and run the server executable it appears to run fine but I get various error messages from my client.exe package (which I won't go into detail here, yet).  Upon stopping the server I get the message "LabVIEW: (Hex 0x8BBB0005) Unable to locate variable in he Shared Variable Engine.  Deployment of this variable may have failed."
    I check the services running and see that the "National Instruments PSP Server Locator" and the "National Instruments Variable Engine" are both in the list and "Started."  I open up the Variable Manager that has been installed on my target machine and manually add the "waveform" and the "command" variables under a process I call "server" and start the process.  After that I start my server.exe that I have compiled from the server.lvib library.  The process gives no error messages until the stop button is pressed, and then I receive the message "LabVIEW: (Hex 0x8BBB0011) The connection to the server was disconnected."
    The compiled programs run fine on my development machine as well as the uncompiled VIs within the LabVIEW development enviornment.  Something tells me that I simply do not have the Variable engine properly configured on my target machine.  Also, the process and variables should automatically be populated under "Local System" in the Variable Manager, right?  I do not need to add them manually, or do I?
    Thanks for your input!
    -Nickerbocker

  • Shared Variable VI development on machine other than server

    I'm about to do my first shared variable code, I read the white paper
    http://www.ni.com/white-paper/4679/en
    Something that isn't immediately clear to me is the expected work flow in actually creating ALL the VIs using the shared variables.  I tried creating the project and the variable as per instructions, easy.  But I'm going to have one of those VIs running as the server of the data and one as the client.  Would these be two seperate project files with the same variable name and type?  One project file with seperate builds for server and client executables?
    Actually, SV might not even be the best way to do what I need.
    I have a PXIe machine with a slot 0 controller that has a mux (a pxi-2503) and dmm (pxi-4072) for getting measurements from multiple channels.  Rather than calling via VI server every time I want to grab a measurement I'd rather have an application running waiting on commands.  I was thinking of creating a crude command/acknowledge data avail/acknowledge scheme to synchronize the PXI slot 0 with the client that will be requesting the data, but I can imagine there is probably a more suitable framework that someone else has no doubt tackled?
    I just need to guarantee that the rack takes the measurement when I want it to (ie, after some other action I've triggered the system to perform) and that the data I get back from it is identifiable.
    Ideally, I'd have a MXI controller and this gets really easy but I won't be able to get ahold of one for months if at all so I'm going this route for now.

    Hi Marcus,
    When I drag a shared variable from the project window into the block diagram and then left click it and go to browse, I'm only presented with variables on my local machine to choose from.  If I switch into programmatic access and then go to browse I'm presented with a nice list and am able to browse to the remote shared variables and select it for my constant/control.  This works fine and I'll remember to do this from now on, I just wonder why the two different behaviors.
    I have this working quite well provided I go ahead and start the VI running either with a built exe or through the vi.  As these instruments are going to ultimately be sitting in a headless (no monitor/mouse/keyboard) PXI with slot 0 rack, I am now trying to figure out how to either start these VIs running remotely.  I thought I'd just be able to drop the .exe into a windows scheduled task and have it run on start up.  This works fine but my client VI doesn't communicate.  If I go ahead and log in to the machine I can see the exe running in the Task Manager.  If I kill that exe and start a new one then I'm able to communicate with the VI though with some initially odd behavior, almost as if when I was running it on the client the SVE had changed the states of the variables locally and then when the new process was started it latched those states and causes me to have race-like conditions.  If I then kill that exe and start another one everything is in its expected "default" state and I don't have race like conditions or get into unexpected states.  I can probably add some code on the client side to avoid this weird behavior but I'd rather understand why things aren't working.  My guess is the SVE and other NI processes on the headless box aren't starting properly until I actually log in?

  • Peculiar behavior of Shared Variable RT FIFO

    I'm trying to "leverage" the enhanced TCP/IP and Shared Variable properties of LabView 8.5.  My application involves (among other things) doing continuous sampling (16 channels, 1KHz/channel) using 6-year-old PXIs (Pentium III) and streaming data to the host.  I developed a small test routine that was more than capable of handling this data rate, even when I had the host put a 20msec wait between attending to the PXI (to simulate other processing on the host).  To do this, I enabled the "RT FIFO" property of the Shared Variable (which was an array of 16 I16 integers) and specified a buffer size of 50 (that's 50 arrays).  Key to making this work was figuring out the "error codes" associated with the SV RT FIFO, particularly the one that says the FIFO is empty (so don't save the "non-data" that is present).
    Flush with success, I started developing a more realistic routine that involves rather more traffic between Host and Remote, including the passing back and forth of "event" data.  These include, among other things, "state variables" to enable both host and remote to run state machines that stay "in sync"; in addition, the PXI also acquires digital data (button pushes, etc.) which are other "events" to be sent to the Host and streamed to disk.  I developed the dual state-machine model without including the "analog data" machine, just to get the design of the Host/Remote system down and deal with exchanging digital data through other Shared Variables.  Along the way, I decided to make these also use an RT FIFO, as I didn't want to "miss" any data.  One problem I had noticed when using Shared Variables is the difficulty of telling "is this new?", i.e. is the variable present one that has been already read (and processed) or something that needs processing.  I ended up adopting something of a kludge for the events by including an incrementing "event ID" that could be tested to see if it was "new".
    Today, I put the two routines together by adding the "generate 16-channels of integer data at 1 KHz and send it to the Host via the Shared Variable" code to my existing Host/Remote state machine.  I used exactly the same logic I'd previously employed to monitor the RT FIFO associated with this Shared Variable (basically, the Host reads the SV, then looks at the error code -- a value of -2220 means "Shared Variable FIFO Read Buffer Empty", so the value you just read is an "old" value, so throw it away).  Very sad -- my code threw EVERYTHING away!  No matter how slowly the Host ran, the indicator always said that the Shared Variable FIFO Read Buffer was empty!  This wasn't true -- if I ignored the flag, and saved anyway, I saw reasonable-looking data (I was generating a sinusoid, and I saw numbers going up and down).  The trouble was that I read many more points than were actually generated, since I read the same values multiple times!
    Looking at the code, the error line coming into the Shared Variable (before it was read) was -2220, and it remained so after it was read.  How could this be?  One possibility is that my other Shared Variables were mucking up the error line, but I would have thought that the SV Engine handling reading my "analog data" SV would have set the error line appropriately for my variable.  On a hunch, I turned of the RT FIFO on the two Event shared variables, and wouldn't you know, this more-or-less fixed it!
    But why?  What is the point of having a shared variable "attached" to an error line and having it return "Shared Variable FIFO Read Buffer Empty" if it doesn't apply to its own Read Buffer?  This seems to me to be a very serious bug that renders this extremely useful feature almost worthless (certainly mega-frustrating).  The beauty of the new Shared Variable structure and the new code in Version 8.5 is that it does seem to allow better and faster communication in real-time using TCP/IP, so we can devote the PXI to "real-time" chores (data acquisition, perhaps stimulus generation) and let the PC handle data streaming, displays, controls, etc.
    Has anyone been successful in developing a data-streaming application using shared variables between a PXI and and PC, particularly one with multiple real-time streams (such as mine, where I have an analog stream from the PXI at 16 * 1KHz, a digital stream from the PXI at irregular intervalus, but possibly up to 300 Hz, and "control" information going between PC and PXI to keep them in step)?  Note that I'm attempting to "modernize" some Version 7 code that (in the absence of a good communication mechanism) is something of a nightmare, with data being kept in PXI memory, written on occasion to the PXI hard drive (!), and then eventually being written up to the PC; in addition, because the data "stayed" on the PXI, we split the signal and ran a second A/D board in the PC just so we could "see" the signal and create a display.  How much better to get the PXI to send the data to the PC, which can sock it away and take samples from the data stream to display as they fly by on their way to the hard drive!
    But I need to get Shared Variables (or something similar) working more "understandably" first ...
    Bob Schor

    Bob,
    The error lines passed into and out of functions are just just clusters with a status boolean, an error code, and an error string, and are not "attached" to a particular function as you describe in your post.  Most functions have an error in input and an error out output, and most functions will simply do nothing except pass through the error cluster if the error in status is True (to verify this for yourself, double click on a function such as a DAQmx Read or Write and look at the block diagram.  If there is an error passed in, no read/write occurs).  This helps prevent unwanted code from  executing when an error does arise in your program.  By wiring the error cluster from your other shared variables to your analog data variable, you're essentially telling LabVIEW that these functions are related and that your analog data variable depends requires that the other shared variables are functioning properly.  The error wire is a great way to enforce the flow of your program, but you must always consider how it will affect other functions if an error does arise.
    Anyways, it's great that you have things more or less working at the moment.  Keep us all updated!

  • Upgrade to 8.5.1 on all computers using shared variables?

    Hello,
    We are currently using DSC 8.5 and hosting the shared variable engine on one 'server' computer with other computers subscribing to network shared variables.  Some of the computers are Windows XP and others are RT.
    When we upgrade to DSC 8.5.1 can we just upgrade the 'server' computer and leave all other computers at 8.5 or do we need to upgrade all systems to 8.5.1 at the same time?  Will computers running 8.5 be able to read/write network shared variables hosted on the DSC 8.5.1 system?  Is such a progressive upgrade not advised?  Thank you in advance.
       - Chris White
         ThinkG Consulting LLC

    Hi Chris,
    The variables pass through the Shared Variable Engine on your server before they are read by other subscribers. Therefore, you do not have to upgrade the DSC on all your subscribers. I hope that answers your question. For further reference on how network pulished shared variables operate as well as the role of the SVE, please refer to this link.
    Ipshita C.
    National Instruments
    Applications Engineer

  • Problems with communication across a network using shared variables

    I have two programs(projects) running on two different computers connected with a LAN. I am using LabVIEW 8.0, and the DSC-module. The program on one of the computers have measurements that I want to collect and show on the program running on the other computer on the network. I choose the indicator where I want to show the data, select ''Properties'', ''Data binding'', ''Shared Variable Engine (NI-PSP)'', ''Network Items'' and then browse for a Network...but the problem is that in my ''Network Neighborhood'' There is only one computer...and that is the one I am one...not the computer on my Network that I want to communicate with....
    Have anyone any suggestions on how to solve this?
    Kind regards Mari

    Mari,
    Check this link regarding trouble shooting network-published shared variables:
    http://digital.ni.com/public.nsf/websearch/6E37AC5435E44F9F862570D2005FEF25?OpenDocument
    This might be a firewall issue, so I would check that first.
    Frode

  • Shared variables update in QuickClient but not in Variable Manager

    Greetings,
    I am using LV 8.6 Developer with the DSC module installed. Also, I'm using WinXP Service Pack 3.
    I am trying to create a VI that will interact with an OPC server connected to some equipment.
    I've created shared variables to read the value of tags in my OPC server exactly according to the instructions on this page:
    http://zone.ni.com/devzone/cda/tut/p/id/6346
    For some reason though, the value of the shared value never updates to reflect the value on the server.
    When I follow the tag on the OPC QuickClient, it updates just fine, but somehow the value of the shared variable isn't updating. 
    I also tried retreiving this data using the DataSocket method in the "Multiple OPC Items Monitor.vi" example, but running that VI crashes LabView every time. 
    Also, I can create a shared variable and write to tags using a VI, but I can't read them.  
    It seems like I'm *this* close to getting the shared variables to work. Any suggestions?

    Hi Rob,
    To answer your questions...
    DataSocket: NI doesn't give me the option to investigate the error when I restart the program. I did a search for .cpp files, but none turned up. I did collect the error report that Windows generates, and I attached it. I'm not sure if that would be something useful or not.
    SharedVariables: I went to use the Distributed System Manager to take a look at the variables. For both my shared variable as well as the tags on the I/O data source, the data type is listed as "advanced" and the quality is "unknown bad."  I collected the logs from the I/O server and attached them. Oddly, when I look through there, I see some Quality=BAD  and some VT_ILLEGAL flags. The deadband is set to zero, and the update rate is 1,000ms.
    Also, I've configured the DCOM and Local Security Policy settings as described in numerous support articles, and my Windows Firewall is turned off. The OPC server and LabView reside on the same computer. 
    I suppose the confusing thing is why the QuickClient works fine, but the SVE doesn't.  
    I've tried this on three different computers with the same results in all cases. Currently, LV and the OPC server is the only software installed on any machine. The only other OPC server I have access to is the LV server, and it seems to work okay. 
    Thanks,
    Wes
    Attachments:
    a793_appcompat.txt ‏133 KB
    screen.JPG ‏105 KB
    OPC I-O Server Diagnostic Information.txt ‏69 KB

  • LV7.1 DSC tag engine VS LV8.6 DSC shared variables

    I'm currently running LV7.1 with DSC and RT. To handle communications and logging RT variables I'm using the init / read / write publish.vi's on the RT side and datasockets on the HMI side (Windows XP). This has worked out great - new tags can be programmatically created in real time with the publsih vi's and then I go to the the .scf file and use the tag configuration wizard to add them to my scf file and handle data logging. This worked very well - the wizard would organize all of the memory tags into folders by block name used by the init publish vi. I could also select entire groups of tags and add hundreds at a time to the .scf file. Hardware Tag also worked in a similar fashion, organizing tags by controller and module folders. Now - looking at LV8.6.I found I can still use the init / read / publish vi's on the RT side - great. However there is not tag configuration editor as in LV7.1 to let me add large numbers of tags through a wizard. The closest thing I've found is to create a library to represent each block name from the RT init publish.vi then use "create bound variables" option under the library to bind the new shared variables to the RT memory tags. I can browse to the tags on the controller by network items, but when I add them it doesn't bring the block name of the tag as it did in 7.1, only the item name. I use a lot of PID loops that share the same tag names (i.e.: P,I,D, mode, output), so not including the block name represents an organizational problem. The problem with this is, it's very labor intensive compared to the wizard in LV7.1 DSC, especially talking about creating systems with thousands of RT memory tags. Also, there is a similar problem with hardware channels (I'm using compact FieldPoint). To log channels via DSC do I have to create a shared variable for each channel to access the DSC logging capabilities? Again how do I add all of the hardware channels in some organized fashion? I hope I'm missing some tool that is an analog to the tag configuration wizard to bring in these channels and organize them. Any help or suggestions would be appreciated. Thanks,Brad

    Hi lb,
    We're glad to hear you're upgrading, but because there was a fundamental change in architecture since version 7.1, there will likely be some portions that require a rewrite. 
    The RTE needs to match the version of DSC your using.  Also, the tag architecture used in 7.1 is not compatible with the shared variable approach used in 2012.  Please see the KnowledgeBase article Do I Need to Upgrade My DSC Runtime Version After Upgrading the LabVIEW DSC Module?
    You will also need to convert from tags to shared variables.  The change from tags to shared variables took place in the transition to LabVIEW 8.  The KnowledgeBase Migrating from LabVIEW DSC 7.1 to 8.0 gives the process for changing from tags to shared variables. 
    Hope this gets you headed in the right direction.  Let us know if you have more questions.
    Thanks,
    Dave C.
    Applications Engineer
    National Instruments

Maybe you are looking for

  • Error deploying EAR that is a Webservice

    In the SAP NetWeaver Developer Studio, when I select the option "Deploy to J2EE engine" on my EAR file, I get the following error:                      java.rmi.RemoteException: Cannot deploy application sap.com/LDAPManagerEAR..                     

  • HP Color LaserJet 1600 Printer

    I really love my HP Color LaserJet 1600 printer but haven't been able to successfully install it in my brand new MacBook Air 1.7 despite several attempts. I have downloaded the correct Firmware Upgrade 20120928 v2.4 from HP Drivers web page. Unlocked

  • Modify Form Number at Bottom of Every Page

    How do I modify the form number at the bottom of every page of a LiveCycle form that I did not create.  The form number appears to be below the table that contains all of the form fields and form-field labels and is on the same line as the page numbe

  • Flickering of safari pages

    When I have multiple safari pages open on my iPhone 5s and try to open one (bring one to the front for using) the specific page while opening it does a  flickering on the sites of the page, anyone has the same issue/problem? How to resolve it? A soft

  • Enterprise Reporting Interactive Object Model

    <p>Using This <a href="http://devlibrary.businessobjects.com/BusinessObjectsXIR2/en/en/general_doc/SDKOverview_Final_EN.htm" target="_blank" title="Interactive Enterprise Reporting Object Model">Diagram</a> <br />Use this diagram to identify which en