Migrate switches from different networks to a single network

Hello, I have a question on migrating C3750 switches between networks.
Our current situation is that we have two networks.
We control the cores on both networks but do not controll all the edge devices on both networks.
We can not access the IOS and configuration on a number of switches because we don't have the login information for those.
In the future if we are to take control of those edge devices how can we modify the IOS and configuration settings for multiple switches at one time?
Within the core we can modify vlans, destroy and recreate to suit our purposes, so that's easy enough.
We would rather not have to visit each and every switch and do this manually as there are over 40 switches and only 2 admins.
Manually doing this requires using the password recovery option method to change the IOS.
Once done we should be able to update the config via CISCOWorks on all the devices,
Or we could do it the other way around and update the config and then update the IOS via CISCOWorks.
Our wish is to attempt to do both via CISCOWorks or some other automated method.
ej

Hi,
Can this be acheived by normal TMS configuration (without Extended Transport Control)? If yes how?
Yes.
Understand the following basic relationship behind transporting chagnes using TMS
....Repository Objects ->are assigned to-> Package ->are assigned to->Single Transport Layer ->is assigned to-> Single Transport Route -> Target System.
The basic concept behind standard Transport Control is that every repository object in Source System (e.g Dev-System) is assigned (via a package) to a certain transport layer, it follows that a change request can only have one target system. So, you can transport change requests from multiple clients of Development System, which you can import into QUA system's clients upon release.
With the standard Transport control program, it is not possible to create two transport routes with the same transport layer from one SAP System. Thus, The extended Transport Control program is used for transporting the changes based on Client specific Transport Routes by using the concept of Transport Group. Using this, one can transport changes to multiple systems, multiple clients using the same transport layer.
Regards
Bhavik G. Shroff

Similar Messages

  • How to manage dell-2816 switch from remote network..?

    Hi,
    According to below diagram how can i manage the dell-2816 switch from other network. It has management ip only worked on default vlan and default vlan is not editable also not routed ,we can only access the switch to connect laptop directly to switch port and if the port has default-vlan id-1 .
    switch to switch trunk doing problem but when using the pvid as a access vlan ID then trunk is working between dell to juniper hope so cisco also work. But the major issue is remote manageability and also snmp , If switch does not getting ping from remotely then how the snmp will work ..?
    Thanks
    Mamdud
    <ADMIN NOTE: Email id removed per privacy policy>

    You would need a layer 3 device on the network that would route between the different networks/VLANs. Without a device performing VLAN routing, your only other option is to be on the VLAN 1 network.
    If you have a client with dual nic ports, you may be able to assign 1 port the VLAN 1 network. The other port would be on the network with the rest of the devices.

  • How to end RDP sessions remotely from different network?

    Hi
    How to end RDP sessions remotely for windows 2008r2 server from different network?
    not from local LAN
    Thanks

    Hi
    what ports need to be open to successfully connect to server behind firewall?
    from WAN to LAN using :
    net use \\servername_or_IP /USER:username “password“
    or
    qwinsta /server:ServerIP
    Thanks

  • Unable to log in from different network same domain.

    Hi, I am having difficulties with sharepoint at a different location.
    Our main site and network that our sharepoint server is on, is 10.1.0.1
    Our second site is part of our domain, and has its own DC with the ip 10.2.1.1
    Our main site and second site are connected through VPN.
    Our users at our second site can't log into sharepoint. They will browse to
    http://intranet and the windows security window asks for credentials. Users will enter their credentials but it will not accept them and keeps asking for them. They do not receive any error messages, just a blank screen.
    I have also tried adjusting the "trusted sites" options with NO SUCCESS. As well as clearing the "Enable Integrated Windows Authentication" option under advance in internet options.

    So we have two domains, DomainA and DomainB.
    You have tested your DomainA user account, which works fine from Site A, on Site B and it fails. All users from Site B also fail to authenticate.
    Can you test a user from DomainB on a machine in Site A?
    Are you able to add users from Domain B to your SharePoint sites through the people picker? That will confirm that you have AD connectivity between your SharePoint farm and the Domain B ADDS servers.
    Next time you test the login process from Domain B use a hosts file to bypass any load balancers and target a single server, then make a note of the time. That will help you to try to identify the login requests in both the windows event logs and the
    SharePoint ULS logs.
    From first impressions this sounds like an inability to authenticate from their network rather than a domain trust issue, although that may still be possible.

  • Combine Accounts from different Generations into a single Table Prompt

    We are on OBIEE 11.1.1.6.2 and using an ASO (11.1.2.1) cube as a datasource.
    I wish to make a drop down menu of only ten accounts in OBIEE. These ten accounts do not all belong in the same generation. The desired Accounts are from Gen6, Gen5 and Gen4. How do I make a single drop down list with these ten accounts when the members belong to different generations ? I have tried building this custom list of ten accounts via Selection Steps but it seems that I cannot cross different generations of the Account dimension.
    Any help would be appreciated.

    Thanks for the reply Christian. I literally tried at least 100 possible iterations of the Evaluate statement and none of them will compile in OBIEE. Before posting, I scoured the Internet for days hoping someone else has had this issue resolved. I had no luck. If you know of anyone that has actually been successful with the EVALUATE statement to make a list of dimension members from different generations, please post the exact code snippet so that I can leverage off of somone else's knowledge.
    I have tried dozens of possible iterations of: with no luck at all.
    EVALUATE('Intersect(%1.dimension.members,{[Account1], [Account2]})',"Account"."Gen1,Account")

  • Problem using Tuxedo from different network

    We are using Tuxedo (7.1) with Clarify eFrontOffice.
    We are trying to access Tuxedo from a different network. We have a NAT address and opened the port for WSL (48800) and also a range (specified in the ubbconfig and compiled) specified for the WSH. When the Clarify client is started, it is connecting to the WSL on port 48800. When tuxedo returns the WSH port to the Client, it is also returning the IP of the server. Since the IP is not recognized in the 2nd network the communication is failing. Is there a way to retun server name instead of IP or a different IP?
    Thanx

    Raju,
    When using Network Address Translation with /WS you should specify the -H
    option to WSL (after the -- option) so that the address of the WSH can be
    mapped back to an address that the client will understand. A bug related to
    the WSL -- -H option was fixed at Tuxedo 7.1 rolling patch level 165, so you
    should obtain the latest 7.1 rolling patch if you are running at an earlier
    patch level.
    The description of the -H option at
    http://e-docs.bea.com/tuxedo/tux71/html/rf537.htm is as follows:
    [-H external-netaddr]
    Specifies the complete network address to be used as a well known address
    template of the WSH process. The address will be combined with a WSH network
    address to generate a well known network address used by the Workstation
    client to connect to a WSH process. It has the same format as the -n option
    except that it substitutes the port number with same length of character M
    to indicate the position of the combined network address will be copied from
    the WSH network address. For example when address template is
    0x0002MMMMdddddddd and WSH network address is 0x00021111ffffffff then the
    well known network address will be 0x00021111dddd dddd. When address
    template starts with "//" network address type assumes to be IP based and
    the TCP/IP port number of WSH network address will be copied into the
    address template to form the combined network address. This feature is
    useful when Workstation client needs to connect to a WSH through a router
    which performs Network Address Translation.
    <Raju Vatsavayi> wrote in message news:[email protected]...
    We are using Tuxedo (7.1) with Clarify eFrontOffice.
    We are trying to access Tuxedo from a different network. We have a NATaddress and opened the port for WSL (48800) and also a range (specified in
    the ubbconfig and compiled) specified for the WSH. When the Clarify client
    is started, it is connecting to the WSL on port 48800. When tuxedo returns
    the WSH port to the Client, it is also returning the IP of the server. Since
    the IP is not recognized in the 2nd network the communication is failing. Is
    there a way to retun server name instead of IP or a differen
    t IP?
    Thanx

  • How to migrate files from different databases to sharepoint 2013?

    Hello everyone,
    I need to migrate files of various formats from two databases to SharePoint 2013 ? How should I pursue? Please explain..
    Scenario : Two different databases on different systems have loads of files. I need to migrate them to SharePoint?
    Any suggestions/ Answers

    Hi,
    You need to copy the database into your network shared folder or SharePoint Server where you wanted to attach this content DB to your newly created web application.
    Hope and Afraid,
    Same Domain has been used. I mean if you move the content db from the server 1 which using the AD1 for authenticate the users,
    So your new server 2 and web application must have configured to authenticate the AD 1 users.Otherwise user not found exception will be thrown. 
    If not  still you can change the site collection administrator for the site which is migrated from the server 1.
    Murugesa Pandian., SharePoint 2010 | MCPD | MCTS |Configure

  • How to switch from different views when a common button is clicked on using View states concept

    Hi
    i have  made a single form for both Login Screen and Registration screen with two states :
    1. BaseState which is the curret state of  state of My application
    2.registrationstate 
    I have a common button for changing from one view to another view .(Not related to any of the state)
    At first the Login screen is loaded , and when the common  button is clicked , i want to switch to Registration Screen .
    <?xml version="1.0" encoding="utf-8"?>
    <mx:Application xmlns:mx="http://www.adobe.com/2006/mxml" layout="absolute">
    <mx:Script>
        <![CDATA[
    // Logic for common button needed .
        public function handleMe(event:MouseEvent):void
        ]]>
    </mx:Script>
        <mx:states>
            <mx:State name="registrationstate">
                <mx:SetProperty target="{formitem1}" name="label" value="Email"/>
                <mx:SetProperty target="{button1}" name="label" value="Change state to Login"/>
            </mx:State>
        </mx:states>
        <mx:Form x="248" y="158">
            <mx:FormItem label="User Name" fontWeight="bold" id="formitem1">
                <mx:TextInput/>
            </mx:FormItem>
        </mx:Form>
    <!-- This is my coomon button-->
        <mx:Button
            click="handleMe(event)"  
            x="297" y="261" label="Change state to Registration" id="button1"/>
    </mx:Application>

    Originally I could not get that to work, but now I have it working:
    <?xml version="1.0" encoding="utf-8"?>
    <mx:Application xmlns:mx="http://www.adobe.com/2006/mxml" layout="absolute">
      <mx:Script>
        <![CDATA[
          import mx.controls.Alert;
          public function handleMe(event:MouseEvent):void{  
            trace(this.currentState); 
            if(currentState=="" || currentState == null){
              mx.controls.Alert.show("base state");
              currentState = "registrationstate"; 
            }else if(currentState=="registrationstate"){
              mx.controls.Alert.show("registrationstate");
              currentState = ""; 
        ]]>
      </mx:Script>
      <mx:states>
        <mx:State name="registrationstate">
          <mx:SetProperty target="{formitem1}" name="label" value="Email"/>
          <mx:SetProperty target="{button1}" name="label" value="Change state to Login"/>
        </mx:State>
      </mx:states>
      <mx:Form x="248" y="158">
        <mx:FormItem label="User Name" fontWeight="bold" id="formitem1">
          <mx:TextInput/>
        </mx:FormItem>
      </mx:Form>
      <mx:Button click="handleMe(event)" x="297" y="261"
        label="Change state to Registration" id="button1"/>
    </mx:Application>
    If this post answers your question or helps, please mark it as such.
    Greg Lafrance - Flex 2 and 3 ACE certified
    www.ChikaraDev.com
    Flex / AIR Development, Training, and Support Services

  • Switching from internet network to printer network to print

    I have a Macbook Pro that I use and also a new Macbook that my grandparents use. We share an HP printer. I was wondering if there was a way to adjust snow leopard so that when i decide to print i don't have to go to the airport menu and change to my printer network and then when i am ready to continue browsing the internet i have to switch back to my internet network which is my dsl box which is wireless to be able to browse the internet. I hope i have explained this clear enough but if not write me back and i will try and explain it better this is my first time on here. Any help would be much appreciated
    ElijahBlue

    You need to connect the printer to the dsl modem/router if possible.
    This way both of you can use the printer.
    There only needs to be one network for all devices.

  • A bug after switching from three-finger-drag to single finger move

    After I three-finger-drag a section of text, I want to move the mouse cursor to other place to select other things. So I quickly change to single finger after the drag and move. Then I either double click or tap to drag to select something. But hey, the mac thinks it is still in the drag lock state of the three-finger-drag, so the first tap will be consumed and it MUST be a failure.
    I understand there is some delay to automatically release the drag lock but in this case a single tap is REQUIED no matter how long I wait. Then I tried three-finger-drag followed by three-finger-drag for the second selection, yeah, it works. Only when I use single finger for the second selection have this problem, and when the swiching is quick.
    For precise selection, I switch quite often, but this problem annoys me a lot. Anyone experience this?
    The trackpad options are Enable dragging without Drag Lock. Thanks.

    Send Apple feedback. They won't answer, but at least will know there is a problem. If enough people send feedback, it may get the problem solved sooner.
    Feedback

  • Displaying views from different componets in a single view

    HI gurus,
    I want to assemble all the views in a single view by using layout
    1. i have 2 DC's, DC1 has 3 components and each component has 4 views
    2. DC2 has 5 Components each has some 6 views
    My requirement is to display all these views in one view of DC1, depends on the condition
    I displayed all DC1 views successfully by using plugs to interface views
    but i want disable this entire viewcontainer and display other view container to display DC2 views at same place
    I thought by doing this when user clicks on that view every time all the views will load, is it the bestprectice to work, if not please suggest me best solution
    Thanks in advance
    Anu

    Dear Anusha,
    Use the component interface > interface view to integrate other DC2 view in the DC1.
    then use the Viewset or Viewcontainer to embed the DC2 view using interface view.
    Search for the communication between dcs.
    Best Regards
    Arun Jaiswal

  • HT5554 How can I tell if an iPhone 5 is locked to a network ( without having to try different network sims)

    How can I tell if an iPhone 5 is locked to a network - without having to try different sims from different networks?

    you can't.  If you really want to know, call Apple Care.

  • Join Nodes from different XML strings

    Hi,
    Please can you help me in joining 2 similar XML documents such that required nodes are appended.
    Need to combine the nodes of XML (input source:String) A and B as below:
    A:
    <?xml version="1.0" encoding="UTF-8"?>
    <ns0:MSG_Cont xmlns:ns0="http://xmlns.sample.xml.com/Xref">
        <ns0:Header>
            <ns0:ProjectName>Services-1</ns0:ProjectName>
            <ns0:TimeStamp>11-05-2007 08:24:08</ns0:TimeStamp>
        </ns0:Header>
        <ns0:Body>
            <ns0:MID_INTER_XREF>
                <ns0:INT_ID>0</ns0:INT_ID>
                <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
                    <ns1:PERS_TITLE>MGR</ns1:PERS_TITLE>
                    <ns1:PERS_FIRST_NM>BUY</ns1:PERS_FIRST_NM>
                    <ns1:PERS_LAST_NM>INT</ns1:PERS_LAST_NM>
                </ns1:CDS_Person>
                <ns0:CLS>48</ns0:CLS>
                <ns0:COM>410</ns0:COM>
                <ns0:SW>P</ns0:SW>
                <ns0:ALT_ID>  </ns0:ALT_ID>
                <ns0:ACTV_CD>I</ns0:ACTV_CD>
                <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
            </ns0:MID_INTER_XREF>
            <ns0:MID_INTER_XREF>
             <ns0:INT_ID>96</ns0:INT_ID>
             <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
              <ns1:PERS_TITLE>MGR</ns1:PERS_TITLE>
              <ns1:PERS_FIRST_NM>TEMP</ns1:PERS_FIRST_NM>
              <ns1:PERS_LAST_NM>GRT</ns1:PERS_LAST_NM>
             </ns1:CDS_Person>
             <ns0:CLS>48</ns0:CLS>
             <ns0:COM>935</ns0:COM>
             <ns0:SW>D</ns0:SW>
             <ns0:ALT_ID>F$</ns0:ALT_ID>
             <ns0:ACTV_CD>A</ns0:ACTV_CD>
             <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
         </ns0:MID_INTER_XREF>
        </ns0:Body>
    </ns0:MSG_Cont>B:
    <?xml version="1.0" encoding="UTF-8"?>
    <ns0:MSG_Cont xmlns:ns0="http://xmlns.sample.xml.com/Xref">
        <ns0:Header>
            <ns0:ProjectName>Services-1</ns0:ProjectName>
            <ns0:TimeStamp>11-05-2007 08:24:08</ns0:TimeStamp>
        </ns0:Header>
        <ns0:Body>
            <ns0:MID_INTER_XREF>
                <ns0:INT_ID>0</ns0:INT_ID>
                <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
                    <ns1:PERS_TITLE>TECH</ns1:PERS_TITLE>
                    <ns1:PERS_FIRST_NM>BUY</ns1:PERS_FIRST_NM>
                    <ns1:PERS_LAST_NM>INT</ns1:PERS_LAST_NM>
                </ns1:CDS_Person>
                <ns0:CLS>98</ns0:CLS>
                <ns0:COM>910</ns0:COM>
                <ns0:SW>P</ns0:SW>
                <ns0:ALT_ID>  </ns0:ALT_ID>
                <ns0:ACTV_CD>I</ns0:ACTV_CD>
                <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
            </ns0:MID_INTER_XREF>
            <ns0:MID_INTER_XREF>
             <ns0:INT_ID>96</ns0:INT_ID>
             <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
              <ns1:PERS_TITLE>TECH</ns1:PERS_TITLE>
              <ns1:PERS_FIRST_NM>TEMP</ns1:PERS_FIRST_NM>
              <ns1:PERS_LAST_NM>GRT</ns1:PERS_LAST_NM>
             </ns1:CDS_Person>
             <ns0:CLS>98</ns0:CLS>
             <ns0:COM>435</ns0:COM>
             <ns0:SW>D</ns0:SW>
             <ns0:ALT_ID>F$</ns0:ALT_ID>
             <ns0:ACTV_CD>A</ns0:ACTV_CD>
             <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
         </ns0:MID_INTER_XREF>
        </ns0:Body>
    </ns0:MSG_Cont>Combined (desired Output):
    <?xml version="1.0" encoding="UTF-8"?>
    <ns0:MSG_Cont xmlns:ns0="http://xmlns.sample.xml.com/Xref">
        <ns0:Header>
            <ns0:ProjectName>Services-1</ns0:ProjectName>
            <ns0:TimeStamp>11-05-2007 08:24:08</ns0:TimeStamp>
        </ns0:Header>
        <ns0:Body>
            <ns0:MID_INTER_XREF>
                <ns0:INT_ID>0</ns0:INT_ID>
                <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
                    <ns1:PERS_TITLE>MGR</ns1:PERS_TITLE>
                    <ns1:PERS_FIRST_NM>BUY</ns1:PERS_FIRST_NM>
                    <ns1:PERS_LAST_NM>INT</ns1:PERS_LAST_NM>
                </ns1:CDS_Person>
                <ns0:CLS>48</ns0:CLS>
                <ns0:COM>410</ns0:COM>
                <ns0:SW>P</ns0:SW>
                <ns0:ALT_ID>  </ns0:ALT_ID>
                <ns0:ACTV_CD>I</ns0:ACTV_CD>
                <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
            </ns0:MID_INTER_XREF>
            <ns0:MID_INTER_XREF>
             <ns0:INT_ID>96</ns0:INT_ID>
             <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
              <ns1:PERS_TITLE>MGR</ns1:PERS_TITLE>
              <ns1:PERS_FIRST_NM>TEMP</ns1:PERS_FIRST_NM>
              <ns1:PERS_LAST_NM>GRT</ns1:PERS_LAST_NM>
             </ns1:CDS_Person>
             <ns0:CLS>48</ns0:CLS>
             <ns0:COM>935</ns0:COM>
             <ns0:SW>D</ns0:SW>
             <ns0:ALT_ID>F$</ns0:ALT_ID>
             <ns0:ACTV_CD>A</ns0:ACTV_CD>
             <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
         </ns0:MID_INTER_XREF>
         <ns0:MID_INTER_XREF>
             <ns0:INT_ID>0</ns0:INT_ID>
             <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
              <ns1:PERS_TITLE>TECH</ns1:PERS_TITLE>
              <ns1:PERS_FIRST_NM>BUY</ns1:PERS_FIRST_NM>
              <ns1:PERS_LAST_NM>INT</ns1:PERS_LAST_NM>
             </ns1:CDS_Person>
             <ns0:CLS>98</ns0:CLS>
             <ns0:COM>910</ns0:COM>
             <ns0:SW>P</ns0:SW>
             <ns0:ALT_ID>  </ns0:ALT_ID>
             <ns0:ACTV_CD>I</ns0:ACTV_CD>
             <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
         </ns0:MID_INTER_XREF>
         <ns0:MID_INTER_XREF>
             <ns0:INT_ID>96</ns0:INT_ID>
             <ns1:CDS_Person xmlns:ns1="http://xmlns.sample.xml.com/PXref">
              <ns1:PERS_TITLE>TECH</ns1:PERS_TITLE>
              <ns1:PERS_FIRST_NM>TEMP</ns1:PERS_FIRST_NM>
              <ns1:PERS_LAST_NM>GRT</ns1:PERS_LAST_NM>
             </ns1:CDS_Person>
             <ns0:CLS>98</ns0:CLS>
             <ns0:COM>435</ns0:COM>
             <ns0:SW>D</ns0:SW>
             <ns0:ALT_ID>F$</ns0:ALT_ID>
             <ns0:ACTV_CD>A</ns0:ACTV_CD>
             <ns0:LST_UPDT_DT>2006-01-30</ns0:LST_UPDT_DT>
         </ns0:MID_INTER_XREF>
        </ns0:Body>
    </ns0:MSG_Cont>Trying to use the dom document.importNode() and appendChild(). But, looks like appendChild removes any already existing node (in this case - ns0:MID_INTER_XREF).
    Any help appreciated.
    TIA,
    Praveen

    Well, the requirement was to have elements from different XML in a single master XML. The way we achieved this - read from each XML, append to a string buffer and construct the combined XML (which passes on for use elsewhere).
    Hope this helps anyone with a similar requirement.
    Many Thanks for looking.

  • V2P Virtual Machine to physical Server migration on IBM x3650 M4 and switch from BIOS to UEFI Boot environment

    Hi there,
    just wanted to share my experience with a manual P2V Migration. The VM became to ressource hungry and it was decided to move it off an ESX 5 Cluster to a dedicated physical Machine.
    V2P Virtual Machine to physical Server IBM x3650 M4 and switch from BIOS to UEFI Boot environment
    Task:
    V2P Migrate a VMware virtual machine to a IBM x3650 M4 with a ServeRAID 5110e RAID Controller or any other LSI RAID Controller without 3rd Party tools.
    This should also work with other RAID Controllers or Servers but be sure to pick the right drivers then.
    Extra Task:
    The VM's boot environment/virtual BIOS is BIOS, not UEFI (as per default VMware Setting). The physical Server is running in UEFI mode.
    The Challenge:
    After restore the Server won't boot or get into a BSOD (7B), because the RAID drivers are missing.
    After restore the VM won't boot because the boot environment has changed from BIOS to UEFI
    Preparations:
    An existing physical Server of the same type and with the same RAID controller and same OS would be nice for troubleshooting and checking the registry.
    An existing DHCP server will make networking things easier.
    Connect the new physical server x3650 M4 to power and network
        create a virtual drive that has at least the size of the existing VM plus the size of the full backup (.vhd). Should be about twice the size of the original vmdk.
    Get a USB Flash stick (I used a 8GB modell so no problem with larger sticks)
    Download and extract LSI MegaRAID Driver on that USB media (I used 6.705.05.00-MR_Windows_Driver directly from LSI website)
    Download and extract INTEL Network Adapter Driver on that USB media (I used 12.11.97.0 of e1r62x64.inf from 19.5 driver release from 2014.09.26 directly from LSI website)
    Step by Step:
    if you have an other physical Server of the same type and same Controller and same OS:
    1.    open regedit and export everything related to SCSIAdapter and megasas2 to .reg files or skip this step and use my files below
        some of this (sub)keys may not be accesible - you will then first take ownership and/or modify permissions to read them
        HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}
        HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\PCI\VEN_1000&DEV_005B&SUBSYS_04121014&REV_05
        HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\megasas2
        this one is more complicated:
        HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase (only relevant are those devices where the service name is megasas2 - export the whole subkey and get the filtering done with tools like notepad++)
        Make a copy of the following files/folders:
        c:\programdata\LSI\
        c:\windows\inf\megasas2.INF
        c:\windows\inf\megasas2.PNF
        c:\windows\system32\drivers\megasas2.SYS
    on the existing VM:
    1.    create a full backup (image) with the built-in Windows Backup Utility and save it in an accessible network location (you will need this one, if anything goes wrong or you want to come back to this point.
        Alternatively you could create a VMware snapshot.
    2.    import the .reg files you created earlier or import my files below.
        Attention: This will make the VM unbootable!
        But it is required to prepare the VM for the new RAID controller when it will be restored on the physical server.
        Do NOT reboot now as this will make the VM unbootable!
    4.    Copy the LSI folder and the megasas2.INF/PNF/SYS files to the appropriate destination folders on the VM.
    3.    again create a full backup (image) with the built-in Windows Backup Utility and save it in an other accessible network location but not where you safed the first backup.
        This will be the "golden" backup if you want, where the RAID controller is prepares. We will rebuild the new machine with this second backup.
    4.    Optional: you could use the Backuputility now to restore the Systemstate of the first backup and reboot or restore the VMware snapshot.
        This will undo the changes we made to the VM.
    on the new physical server:
    1.    boot the physical server from Windows Server 2008 R2 SP1 DVD
    2.    when it is ready to install, press shift+F10 to get command prompt and do not click to install Server 2008
    3.    check driveletter of the USB stick with diskpart list vol (was C: at my Server, so don't wonder about that letter)
    3.    load drivers for ServeRAID SAS controller (this is mandatory to see the volume in diskpart)
        drvload c:\srv_2008_x64\megasas2.inf
    4.    load drivers for INTEL I350 Gigabit NIC's (you will need this to access the backup that is on the network)
        drvload c:\PRO1000\NDIS62\e1r62x64.inf
    5.    wpeinit (will start network. wait ~15 sec to let it start and get IP address)
        check if you have IP connectivity an address with ipconfig, if not, use an other NIC driver and repeat steps 4+5
    6.    create the EFI and BCD
        diskpart
        list disk
        select disk x (where x is the number of the disk to convert)
        clean
        convert gpt
        create partition EFI size=128
        format fs=fat32 quick label=EFI
        assign letter=i or any other free drive letter
        create partition MSR size=128
    6.1    Copy EFI bootloader to EFI partition
        i: (where i is the letter of your EFI partition)
        mkdir EFI\Boot
        mkdir EFI\Microsoft\Boot
        copy x:\Windows\Boot\EFI\bootmgfw.efi i:\EFI\Microsoft\Boot (where x ist the default letter of the current Windows PE environment)
        copy x:\Windows\Boot\EFI\bootmgfw.efi i:\EFI\Boot\bootx64.efi (note that the file will be renamed to bootx64.efi)
    7.    create the new partitions
        diskpart
        create partition primary size=100000 (edit the size to your needs. this will later become the system drive of your server)
        format fs=ntfs quick label=Windows
        assign letter=Y or any other free drive letter
        create partition primary size=990000 (this will temporarily store your backup and we need it for the restore process)
        format fs=ntfs quick label=Backup
        assign letter=B or any other free drive letter
        exit
    8.    map network drive and copy the backup .vhd  to the local disk
        net use L: \\networklocation\where\you\saved\the\backup (enter the credentials when asked)
            copy the .vhd file that contains the OS of your VM to the local Backup Partition B. The relevant vhd file is usually the largest file in that fileset.
            Note that the names are very similarly - be sure to get the correct file!
        copy "L:\WindowsImageBackup\VMNAME\Backup 2015-02-03 123456\00e767c6-xxxx-xxxx-xxxxxxxxxxxx.vhd" B:\
            give it time, this is slow and will take some minutes/hours and you will not see any progress! Look at the disk-LED's to see if anything is still happening
    9.    mount the .vhd and copy it's contents to the new system partition
            Note that you can only mount a locally stored .vhd. You cannot mount a .vhd in a network location.
        diskpart
        select vdisk file=B:\00e767c6-xxxx-xxxx-xxxxxxxxxxxx.vhd
        attach vdisk
        select vol 5 (where 5 is the number of the mounted vdisk)
        assign letter=Z or any other free drive letter
        exit
    10. Restore the files from the image
        z: (where z is the letter of your mounted .vhd)
        xcopy * Y:\ /e /c /h /k /o /b /q /y (where Y: is the letter of your new partition with the label "Windows")
            several "Access denied" messages appear, ignore them. Those are SystemVolumeInformation folders.
    11.    Create Boot Configuration Data (BCD)
        bootrec /RebuildBcd
            this will try to repair the missing BCD on the second of the two small partitions we created earlier in and should normally work, otherwise you'll have to create BCD manually (search google for that procedure)
            Note that it may find more than one Windows installation and ask which sould be added to the boot list. Be sure to select only the one that is in the correct Volume (Y:\)
        that's it - exit the DOS command box and close the "Install Windows" Window, after a prompt it will reboot.
        Select "Start Windows Normally", if Windows Error Recovery appears.    
    12. Preparing Windows
        When Windows boots for the first time, DO NOT reboot if you are asked, it won't come back at this stage!
        Install Intel chipset drivers for the Server (I used "intc_dd_inteldp_9.4.0.1026_windows_32-64.exe" from IBM website)
        Open Device Manager, uninstall the "RAID-Controller" with the exclamation mark. You cannot install the correct driver for this Device at this point, it will bring you the error: "Cannot create a stable subkey under a volatile
    parent key"
        Once again, DO NOT reboot!
        In Device Manager select Action>Add Legacy Hardware
        click Next
        select Hardware manually
        select Storage Controller as Type
        LSI should be listed, select "LSI MegaRAID SAS 9281-8E"
        click Next, ignore the error "Code 10" Message.
        Click Done.
        Rightclick the LSI MegaRAID SAS 9281-8E device with the exclamation mark in Device Manager
        select Update driver
        select Browse my computer for driver software
        select let me pick from a list of device drivers on my computer
        select "Have Disk"
        browse to the folder where the extracted RAID driver 6.705.05.00-MR_Windows_Driver is located (e.g. USB Flash stick E:\6.705.05.00-MR_Windows_Driver\srv_2008_x64)
        then unselect "Show Compatible Hardware"
        on the right side, scroll up and select "IBM ServeRAID M5110e SAS/SSATA Controller"
        ignore the Update Driver Warning and click Yes
        click Next, ignore the error "Code 10" Message.
        ignore the exclamation mark on "IBM ServeRAID M5110e SAS/SSATA Controller" in Device Manager but be sure that there is only this controller and no other RAID-Controller or LSI SAS Controller listed under "Other Devices"
    or "Storage Controllers"
        NOW you are safe to reboot
        After reboot you will find two "IBM ServeRAID M5110e SAS/SSATA Controller" in Device Manager
        Rightclick and uninstall the one with the exclamation mark. Do not tick the checkbox to remove the driver as well!
    You're done!! (hopefully)

    Windows Registry Editor Version 5.00
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase]
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C31115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C38015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C41115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C48015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C51115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C58015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C61115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C68015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C71115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C78015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C81115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C88015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C91115D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_C98015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_D20219E5]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0060&SUBSYS_D20319E5]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0071&SUBSYS_00721137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00011BD4]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00721137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00731137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_008F1137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00B01137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00B11137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00B61137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00B71137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00C21137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_00C31137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_03B11014]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_040015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_040D1014]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_10541000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_11771734]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_14581002]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_1F201462]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_30351054]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_350C8086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_350D8086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_822910F1]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_843B1043]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_84711043]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92211000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92401000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92408086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92411000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92418086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92421000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92431000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92441000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92A01000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0073&SUBSYS_92A11000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0078&SUBSYS_92501000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0078&SUBSYS_92511000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0078&SUBSYS_92701000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_00011BAA]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_00021BD4]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_00791137]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_02001AE3]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_03B21014]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_03B31014]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_03C71014]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_070015D9]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_11761734]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_11B31734]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_30361054]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_350B8086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_84731043]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_84801043]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_8985152D]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92551000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92561000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92568086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92601000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92608086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92611000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92618086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92621000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92631000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92641000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92648086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92671000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92678086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92681000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92688086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92751000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92758086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92761000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92768086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92771000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92801000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92808086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92811000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92821000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92828086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92841000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92881000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92891000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92901000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_92908086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_D20819E5]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0079&SUBSYS_D20919E5]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0409&SUBSYS_10091000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10011000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10018086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10021000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10031000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10038086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10041000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10081000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10088086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_100C1000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_100D1000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10811734]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_10a31734]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_20041000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_20051000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_30161054]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_34908086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_35008086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_35018086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_35048086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_35078086]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0411&SUBSYS_82871033]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"
    [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\PCI#VEN_1000&DEV_0413&SUBSYS_10051000]
    "ClassGUID"="{4D36E97B-E325-11CE-BFC1-08002BE10318}"
    "Service"="megasas2"
    "DriverPackageId"="megasas2.inf_amd64_neutral_8eb95ad00f4c26d7"

  • How to migrate DB from single node 10gR2 to RAC 11gR2 on diff platform?

    How to migrate DB from single node 10gR2 to RAC 11gR2 on different platform with possible minimum downtime? We have a situation of upgrade/migrate oracle 10gR2 single instance DB to 2-node RAC 11gR. The source OS is Solaris 10 on SPARC and the target OS is Linux (the target servers could be changed to Solaris 11 x86 if needed). What is the best solution on that?
    Thanks,

    Technically, can do the following for upgrading and migration?
    1. Create 11gR2 oracle home on the same server and upgrade the database from 10gR2 to 11gR2 by running conversion (2 hour down time?)
    2. Set up Heterogeneous Primary and Physical Standbys by RMAN. The standby is the RAC with ASM. No need down time. (from Solaris Space to Linux - this may be a problem)
    3. At the cutoff time, activate the standby DB from the RAC ASM.
    If feasible, do we have some detail guild line for each step?

Maybe you are looking for