Open loop with nestedLineStyle

Hi,
Could someone confirm, that InDesign will go into open loop if
app.findTextPreferences.appliedCharacterStyle = charStyle;
and in some story, some paragraph(s) has this charStyle set as a nestedLineStyle further then from 1st line
(from 2nd and next)
i.e setting looks like:
[None]          for     1     line
charStyle       for     2     lines
My ID CS5 gone out of memory with that...
Only way to run is place mouse insertion point somewhere inside "charStyle" range of text.
Did you notice that also?
rgds
PS
I mean when story.findText() is run from script not  from UI
Message was edited by: Jump_Over

Thank you Jasper S.
I think you understand me well.
I tell you more informations.  
1) The computer is working in Windows XP Professional (Just Theme).
2) It happens also at low velocity and acceleration.
3) I think when the motor stops moving, it fails to translate into hardware steps.
  Because when the motor stops, "Current Trajectory Position" and "Encoder Counts" are equal.
4) I checked status registers on the card when it works abnormally, but can't find any error message and flgs.
5) To make matters worse it happens occasionally, so it's difficult to find out the reason.
6) Strange as it may sound, when I touch the motion connector correctly,  the abnormal behavior frequency decrease.
  So I tried to exchange a new motion b/d and a motion cable but it was just same error situation.
  I can't understand because I just use "OPEN LOOP",  it is no matter whether servo driver works well or not.
7) Do I have to change PC? I already tried to exchange PCI Slot position.
I need more information about this.
I'm in trouble because this system is operating at foreign country.
It is fatal error  even if it happens once per day....
Please help me once more. Thank you.

Similar Messages

  • Safari opens in loop with macbook - trojan message win32xepcj

    Safari opens in loop with macbook - trojan message win32xepcj
    I can only close Safari

    It's not a virus. It's a JavaScript scam that only affects your web browser, and only temporarily.
    Some of those scam pages can be dismissed very easily. Press command-W to close the tab or window. A huge box will pop up. Press the return key and both the box and the page will close. If that doesn't happen, continue.
    From the Safari menu bar, select
              Safari ▹ Preferences... ▹ Security
    and uncheck the box marked Enable JavaScript. Leave the preferences dialog open.
    Close the malicious window or tab.
    Re-enable JavaScript and close the preferences dialog.
    If the Preferences menu item is grayed out, quit Safari. Force quit if necessary. Relaunch it by holding down the shift key and clicking its icon in the Dock. From the menu bar, select
              Safari ▹ Preferences... ▹ Privacy ▹ Remove All Website Data
    to get rid of any cookies or other data left by the server. Open your Downloads folder and delete anything you don't recognize.

  • Difference between open loop and closed loop mode when finding the index on a stepper motor axis.

    I have a test system which uses a PXI-7352 motion controller with a MID-7602 stepper motor drive to position a 200 step/revolution stepper motor with an attached 1000 line encoder.  The MID-7602 is configured for 64 microsteps per step, giving 12,800 microsteps and 4000 encoder counts per revolution.  The system is controlled using LabView 7.1 and NI-Motion 6.13.  To home the motor, I've defined a sequence in MAX which first finds the reverse limit switch and then moves forward to the encoder index pulse.
    When finding its reference in open loop mode, the system its reference at the same microstep each time.  When findings its reference in closed loop mode, the system finds its reference somewhere within about a 20 microstep wide range.
    I hope somebody out there with more experience with this controller can describe the difference between finding the encoder index in open loop mode and finding the encoder index in closed loop mode. 
    Thanks,
    Mark Moss

    Hello Mark,
    I suspect that the behavior you are experiencing has today
    with the resolution difference between your encoder and your
    microstepping.  Let me illustrate with an
    example:
    Example Setup
    Stepper
    Motor
    NI
    Motion Controller
    10
    steps per encoder pulse (Every 10 steps the controller gets an encoder
    pulse, therefore positions 0-9 all appear to be 0 to the controller)
    The
    system has a maximum of 3 pull in moves set
    Open Loop Scenario
    The
    system is commanded to go to position 9.
    The
    controller sends out 9 pulses.
    The
    motor moves to position 9.
    Closed Loop Scenario
    The
    system is commanded to go to position 9.
    The
    controller sends out 9 pulses.
    The
    motor moves to position 9.
    The
    controller checks its position and sees that it is still at position 0
    because it has not received an encoder pulse.
    Because
    the controller thinks it is still at position 0, it sends another 9 pulses
    as its first pull in move.
    The
    motor moves to position 18.
    The
    controller checks its position and sees that it is at position 10 because
    it has only received one encoder pulse.
    Because
    the controller thinks it is still at position 10, it sends1 reverse pulse
    as its second pull in move.
    The
    motor moves to position 17.
    The
    controller checks its position and sees that it is at position 10 because
    it has only received one encoder pulse.
    Because
    the controller thinks it is still at position 10, it sends and additional
    single reverse pulse as its third pull in move.
    The
    motor moves to its final position of 16.
    I believe something similar is happening with your
    application as it looks for the index pulse. 
    Because the controller does not compensate for what it perceives as
    position error in open loop mode, the motor always goes to the same commanded
    position.  In closed loop mode, the motor
    is bouncing around inside the single index encoder pulse trying to find a
    certain position.
    There are several recommendations I can make towards
    correcting this behavior.  These
    recommendations are in order of effectiveness:
    Setup
    your system so that there are more encoder counts per revolution than
    steps per revolution.
    Turn
    off pull-in moves by setting them to 0 in MAX.
    Use an
    open loop configuration.
    Play
    around with the pull in window in MAX.
    Regards,
    Luke H

  • Open Loop Problem of PCI-7344

    Dear Partners
    I have a big trouble....
    Any suggestion would be appreciate!
    Here is the hardware and software that I am using
     S/W : MAX 3.1.1
               LabVIEW 7.1
               NI Motion 7.0
     H/W : PCI-7344
               UMI-7764 
                YASKAWA Servo Driver
    I've tested my motion B/D step by step
      1) Start Max3.1.1 / MySystem / Devices and Interfaces /NI Motion Devices /
           PCI7344(1)/Interactive/1-D Interactive
      2) Slect "OPEN LOOP"
      3) Input steps : Velocity, Acceleration, Deceleration
      4) Input steps : Target Position = 100000
      5) Click  "Apply"
      6) Click  "Start"
    But sometimes it stops generating steps.
    it occurs very very irregularly.
    I can't understand because I use "OPEN LOOP"
    and "Current Trajectory Position" must increase until "TargetPosion" whether the asis move or not.
    Also there is no limit signals..
    Please see the image file attached.
    It's very simple I control motion b/d with OPEN LOOP MODE.
    and, I think the servo Driver works well because command steps and encoder pulses are equal.
    Please Help me!!!
    Crane
    Attachments:
    7334error.GIF ‏117 KB

    Thank you Jasper S.
    I think you understand me well.
    I tell you more informations.  
    1) The computer is working in Windows XP Professional (Just Theme).
    2) It happens also at low velocity and acceleration.
    3) I think when the motor stops moving, it fails to translate into hardware steps.
      Because when the motor stops, "Current Trajectory Position" and "Encoder Counts" are equal.
    4) I checked status registers on the card when it works abnormally, but can't find any error message and flgs.
    5) To make matters worse it happens occasionally, so it's difficult to find out the reason.
    6) Strange as it may sound, when I touch the motion connector correctly,  the abnormal behavior frequency decrease.
      So I tried to exchange a new motion b/d and a motion cable but it was just same error situation.
      I can't understand because I just use "OPEN LOOP",  it is no matter whether servo driver works well or not.
    7) Do I have to change PC? I already tried to exchange PCI Slot position.
    I need more information about this.
    I'm in trouble because this system is operating at foreign country.
    It is fatal error  even if it happens once per day....
    Please help me once more. Thank you.

  • Why are my steppers misbehaving in closed loop mode, but work fine in open loop

    I have a 7344 controlling a 4 axis prototype machine, which is configured with 50,000 steps/rev and linear encoders providing 50800 counts per inch. The physical properties of the machine are less than perfect (prototype!), so there is a considerable amount of backlash in the hardware (about 0.008" - 0.010").
    The observed behaviour is as follows: when repeatedly blending in the X,Y plane using vector space 1 in closed loop mode, an axis will be driven (uncommanded) to the zero encoder reading (home position) occasionally (about 1 move in 600). I have kept a log of the commanded positions being passed to the controller (via the flex_load_vs_position function) and a move to zero is not being com
    manded. The application is single-threaded, so there is no chance of race conditions. The ready state of the board is being confirmed by means of the flex_check_blend_complete function call before any blend is commanded. The programmed relationship between steps and counts/revolution have been independantly confirmed as being correct.
    An A-B-A test with the only change being to initialise the X & Y steppers in open loop instead of closed loop then 'works' - although the physical positioning of the hardware is unsatisfactory due to the physical characteristics of the prototype machine already mentioned, hence the necessity to run closed loop.
    I am inclined to interpret the evidence as suggesting that the 7344 is causing an 'occasional' uncommanded move to zero as a result of some interaction between pull-in moves and commanded position on a system where there is a considerable degree of 'elasticity' between the commanded position and the achieved position allied to a rapid-fire de
    livery of blend moves.
    This problem can be replicated under versions 5.0.1 and 5.2 of the FlexMotion software.
    I can clearly run without bumping into the problem by running open loop, but unfortunately that is not acceptable in this situation. Any ideas, anyone?

    Hi, and thanks for coming back so promptly. I think I need to give you some more information - sorry if it turns into a long post!
    The system behaviour when it 'misbehaves' is that it starts the anomolous behaviour well clear of any home or limit switch (>6"). When it 'goes wrong', it then slews one or both axes to the zero position. Having arrived at the zero position, it then carries on with the next blend without killing the motor.
    The initialisation functions include a seek to home switch, a search for the nearest index point, and a zeroing of the encoder count at the index pulse: hence the zero point is a little displaced from the home microswitch.
    I believe that once the system has 'gone wrong', it is stopping at the zero point *not* the h
    ome switch.
    I have carried out some further tests that may be of help:
    If I place a large (1 sec) inter-blend delay in the calling functions, the anomalous behaviour is not noticed. However, the start/stop nature of each move means that this test is knocking the bejezus out of a rather fragile prototype machine, so I can't do this too often!
    The encoder positions are being read back on each move cycle and monitored, and they are not showing any anomolous behaviour, so I don't think they are the culprit. I have placed a 'scope on the quadrature encoder inputs and the edges are good and sharp with no real indications of noise.
    I could test with a blend factor other than -1 if you think that might be illuminating?"

  • Error -70006 when using stepper motor in Open Loop Mode

    We have a LabView program that runs a test in which a table is rotated. At the end of the test, the table is supposed to rewind. Instead, the following message appears:
    Error -7006 occurred at Read Trajectory status.flx
    Possible reasons: For FlexMotion, an invalid axis number or other resource ID (Vector Space, Encoder, I/O Port, and so on) was used.
    We have the PCI-7344 interfaced with a UMI-7764 and a Zeta4 that is controlling a ZETA83-93 stepper motor. There is no encoder in the system for this motor. The stepper loop mode was originally set to closed loop but the motor behaved erratically (moving multiple times when instructed by MAX to move once). The stepper loop mode was changed to open loop and the m
    otor started behaving properly, but that is when the error message starting appearing. Are there any other configuration settings, such as Primary Feedback (which is now set to Encoder) or ? that I may need to correct to resolve this error?

    First of all I would check a couple of things. The reason why your motor was not behaving properly in closed loop stepper configuration is most probably related to the fact that you don't have the encoder counts per revolution adn the stepper steps per revolution properly configured for your motor. Please follow the instructions found in the following knowledgebase:
    http://digital.ni.com/public.nsf/websearch/29edb56​146f274a386256a1c00624310?OpenDocument
    When you configure an axis in closed loop stepper mode, we use the information of the encoder to generate the adequate velocity profile. If the encoder counts and steps per revolution are not properly matched, then the motor will not execute the moves properly. What you need to do is the following:
    1.-Configure your axis as closed loop stepper in the Axis Conifguration Section in MAX.
    2.- In thbe 1-D Interactive Basic panel, kill the motor and click on reset position.
    3.- Manually rotate the motor one revolution.
    4.- In the advanced panel on 1-D interactive, read the Encoder Value. This is the value you should enter on the Axis Encoder Counts per Revolution under Axis Configuration. Press Apply.
    5.- Go back to the 1-D interactive Basic Panel. Change the bullet selector unbder Stepper Loop Mode from Closed to Open. Run a 10000 step move.
    6.- When the move is finished, read the encoder counts from the advanced panel. This will tell you how many counts you have in 10000 steps. You can now calculate the stepper steps per revolution by the following formula:
    (# of steps per count)*(# counts per revolution) = # steps per revolution.
    Your motor should work fine in closed loop stepper configuration now and the error should not appear. Please make sure you are using the latest version of our driver (Ni-Motion 6.0.1)to avoid older firmware errors and fixed bugs from affecting your system. You can get it from:
    http://digital.ni.com/softlib.nsf/webcategories/85​256410006C055586256BB9002C16DF?opendocument&node=1​32070_US

  • Adobe Extension Manager loops with the following message: "The Extension Manager will now launch and

    Hi, whenever I open Dreamweaver CS5 I get this message:
    Adobe Extension Manager loops with the following message:
    “The Extension Manager will now launch and finish updating Dreamweaver”.
    Then the manager starts and I have to wait and click a few buttons until I can close it.
    How can I stop the Extension Manager popping up?
    Thanks for advice.

    Seems to be a lot of this going on. Wondering if we're wasting our time with this??!!

  • System identifica​tion for open loop unstable plant?

    Hello,
    I have been trying to use system identification on labview. My problem is that my plant is open loop unstable and none of the tutorials or examples I have found seem to cover this so I cannot get it to work. Does anyone have any suggestions as to how I should go about it? My plant has an RC servo so it needs a PWM signal to stimulate it.
    Thanks
    Adam

    adamkse wrote:
    I want to control my plant with lead/lag control but I do not know the plant model which makes this very difficult. I cannot theoretically calculate it because the information I need to obtain a numerical transfer function or state space model is unavailable.
    I have it controlled with PID at the moment but this is not ideal.
    I am trying to use the system identification toolkit to obtain a transfer function but I do not know what to do because the examples do not work for open loop unstable plants.
    Adam
    Ok Open loop unstable functions cannot be predictably controlled (hence the terms; open loop and unstable,)  Not being able to model the actions is a bit of a problem too.
    Somehow, someway you need to get some kind of model or some kind of feedback to either provide stability in the plant or close the loop.
    Adding hardware (sensors) is the most likely solution.
    tell me more about the plant, I do this kind of thing for a living, so I could offer some ideas. 
    Jeff

  • Why do I get a Track out of memory error while running open loop frequency response?

    MatrixX Build 61mx1411: I get a "Track out of memory" error when I run the Open Loop Frequency Response from the MatrixX pull down tools. What can I do to prevent this? We are running on an HP B1000 with 768 MB of RAM under HP-UX 10.2.

    In the old days of Mx say Version 5 and prior the user actually selected the amount of memory that would be allocated. Depending on the size of the model etc. you would have to allocate memory. In version 6.0 and going forward there is no need for the user to manually allocate the memory.
    Build {rstack=50000,istack=200000,sstack=50000,cstack=50​0 000}
    If this is a command in a script file that you are running and the error is resulting from that then I would try commenting out everything after the letter d in the word build and then starting it back up.
    i.e. only use Build
    I don't believe that there is a way to manually allocate the initial SystemBuild Stack size.
    I believe initially the stack size is set to 10010.
    However, one way
    you can manually set the initial SystemBuild stack size,is to create a large StateSpace as soon as you start up SystemBuild. This will prevent piece-meal reallocs while using SystemBuild.
    You can created a new SuperBlock in SystemBuild and then drop down a StateSpace Block with 199 inputs and 199 Outputs and 1 State and entered ones(200,200)as the StateSpace Matrix without any problems. This would resize this internal stack to at least 40000.
    You really should not have to do this but if that helps then you might think about doing this in your startup.ms file you could use SBA or load the file then you could delete the superblock and begin working.
    "Bob" gave me this little tid bit.
    Please let me know if any of this is of use.
    Garrett
    Garrett Thurston
    [email protected]
    Phone: 781.993.5540

  • Open file with reference

    Hi
    I want to open files with a reference in hidden mode. Is this possible?
    Because I want to make a program where the user can choose a new test station and then the controls and indicators will be created (or become visible) and the subroutine begins to run.
    Does anybody have a good idea or even an example how to do this?
    Best regards,
    Yves

    Hi Yves,
    You could control your Test- VI with a global variable as shown below. This solution uses two independent while- loops. The Test-VI won't be opened and does the work invisible.
    This is the Main-VI
    And this is the Test-VI
    Greets, Dave
    Message Edited by daveTW on 09-28-2006 03:30 PM
    Greets, Dave
    Attachments:
    Test VI.png ‏2 KB
    Control VI.llb ‏31 KB
    Main VI.png ‏7 KB

  • Is it possible to use software limits on 7354 board when switching control modes from open to closed or closed to open loop?

    Is it possible to use software limits on 7354 board when switching control modes from open to closed or closed to open loop?

    Hello Richard,
    When you say 'open loop' and 'closed loop', are you referring to running the application in position and torque mode? If not, how exactly are your controlling a servo motor in open loop? 
    In closed loop mode, the encoder values will be used as reference and the motion VIs can be used to configure the software limit as required. Are you currently losing the software limits? If so, how exactly are you losing these values? I am not sure I understood what exactly is happening with software limits in your program, so any more information on this would be useful. 
    Vivek Nath
    National Instruments
    Applications Engineer
    Machine Vision

  • Opening files with servlet

    Okay... I'm new to using servlets. Not so much to jsp, just to using servlets. I have one process on our site that is using servlets and I'm trying to mimic how that is using em but am having no luck.
    I am trying to open files with a servlet. I have the class built and compiled, but mainly pulled it from Java World. I evenually will need to pass the servlet the filename and path I want open but in this example it has the file set. My problem is I want to send users to a jsp file where I check user authentication and call the servlet to open the doc, but I don't know how to call the servelet or what to send it. If someone could maybe walk me through this.
    Here's my servlet:
    package cmxx.fileServe;
    import java.io.*;
    import java.util.*;
    import javax.servlet.*;
    import javax.servlet.http.*;
    public class fileServe extends HttpServlet {
    final static String CONTENT_TYPE_DOC = "application/msword";
    final static String CONTENT_TYPE_HTML = "text/html";
    final static String document = "/docs/form_41.doc";
    public void doPost(HttpServletRequest request, HttpServletResponse response)
    throws ServletException, IOException
    doGet(request, response);
    public void doGet (HttpServletRequest request, HttpServletResponse response)
    throws ServletException, IOException
    PrintWriter out;
    out = response.getWriter();
    HttpSession websession = request.getSession(true);
    response.reset();
    response.setDateHeader ("Expires", 0);
    response.setDateHeader("max-age", 0);
    try {
         response.setContentType(CONTENT_TYPE_DOC);
    FileInputStream fileInputStream = new FileInputStream(document);
    ServletOutputStream servletOutputStream = response.getOutputStream();
    int bytesRead = 0;
    byte byteArray[] = new byte[4096];
    while((bytesRead = fileInputStream.read(byteArray)) != -1) {
         servletOutputStream.write(byteArray, 0, bytesRead);
    servletOutputStream.flush();
    servletOutputStream.close();
    fileInputStream.close();
    } catch(Exception ex) {
         throw new ServletException(ex.getMessage());
    } /* end doget */
    } /* end class */

    I'm trying a new servlet. But am getting a few compile errors. Can someone help?
    Here are my Errors:
    43 cannot resolve symbol
    symbol : class URL
    location: class cmis.fileServe.fileServe2
    URL url = new URL(fileURL);
    ^
    43 cannot resolve symbol
    symbol : class URL
    location: class cmis.fileServe.fileServe2
    URL url = new URL(fileURL);
    ^
    57 cannot resolve symbol
    symbol : class MalformedURLException
    location: class cmis.fileServe.fileServe2
    } catch(final MalformedURLException e) { 
    ^
    Code:
    package cmis.fileServe;
    import java.io.*;
    import java.util.*;
    import javax.servlet.*;
    import javax.servlet.http.*;
    public class fileServe2 extends HttpServlet {
    public void doPost(HttpServletRequest req, HttpServletResponse res)
    throws ServletException, IOException
    ServletOutputStream out = res.getOutputStream();
    // Set the output data's mime type
    res.setContentType( "application/pdf" ); // MIME type for pdf doc
    // create an input stream from fileURL
    String fileURL = "http://www.adobe.com/aboutadobe/careeropp/pdfs/adobeapp.pdf";
    // Content-disposition header - don't open in browser and
    // set the "Save As..." filename.
    // *There is reportedly a bug in IE4.0 which  ignores this...
    res.setHeader("Content-disposition", "attachment; filename=Example.pdf" );
    // PROXY_HOST and PROXY_PORT should be your proxy host and port
    // that will let you go through the firewall without authentication.
    // Otherwise set the system properties and use URLConnection.getInputStream().
    BufferedInputStream bis = null;
    BufferedOutputStream bos = null;
    try {
    URL url = new URL(fileURL);
    // Use Buffered Stream for reading/writing.
    bis = new BufferedInputStream(url.openStream());
    bos = new BufferedOutputStream(out);
    byte[] buff = new byte[2048];
    int bytesRead;
    // Simple read/write loop.
    while(-1 != (bytesRead = bis.read(buff, 0, buff.length))) {
    bos.write(buff, 0, bytesRead);
    } catch(final MalformedURLException e) {
    System.out.println ( "MalformedURLException." );
    throw e;
    } catch(final IOException e) {
    System.out.println ( "IOException." );
    throw e;
    } finally {
    if (bis != null)
    bis.close();
    if (bos != null)
    bos.close();
    } /* end class */

  • Is it possible to micro step using the Pci7314 (open loop) controller and umi7764 and Labview.

    Is it possible to micro step using the Pci7314 (open loop) controller, umi7764 and Labview. if so how would this be set up. i have searched the valuemotion vi libraries and found no microstepping functions. Please could you offer any advice. cheers JON ROGERS

    Hi Jon,
    Micro-stepping is a property of the motor amplifier (motor drive) rather than the controller. It sounds like you are using a 3rd party drive, since you have a UMI. You want to check with your motor amplifier documentation to see if it's supported. Usually, there will be dip-switches on the drive that sets the microstep factor.
    Hope this helps. Please let me know if you have any questions.
    Thanks,
    Ken Sun
    Applications Engineering
    National Instruments

  • GR/IR:  Open receipts with vendor name

    Hello SAP Gurus-
    I am not sure if we are doing something wrong but we are currently reconciling our GR/IR account and what we noticed is that when we added the vendor name to the report with the help of an OSS note, we noticed that it gives us all transactions that make up the balance however it isn't what we wanted exactly.
    What we were looking for was once we execute MR11 and handle all differences, we want to see only open receipts with the Vendor name.  How can we achieve this?  Is there a report?  Should the GR/IR account be set up as a clearing account?
    Any help/ insight is greatly appreciated!

    figured it out

  • Process.start("winword", filename) can not open file with space in the path and name

    Hi,
    I am trying to write a class which can open file with selected application. for simplicity, now I just hard code the varaibles.
    the problem: if the path or file name has space in it, even it exist, winword still can not open it.
    could someone kindly show me what I did wrong and how to do it properly.
    Thanks in advance.
    Belinda
    public static class FileOpen
    public static void info()
    string path = @"c:\a temp folder\aaa 1.txt";
    if (File.Exists(path))
        // the file I am using in the sample does exist
         MsgBox.info("yes");
    else
         MsgBox.info("no");
    // working
    //Process.Start("winword", "c:\\aaa.txt");
    // not working
    //Process.Start("winword", "c:\aaa.txt");
    // not working
    Process.Start("winword", "c:\\a temp folder\\aaa 1.txt");
    // not working
    Process.Start("winword", path);

    string AppPath;
    AppPath = ReadRegistry(Registry.CurrentUser, "Software\\FabricStudio", "TARGETDIR", value).ToString() + @"help";
    string FileName = "'"+ AppPath + "\\ImageSamples.doc" + "'";
    try
    System.Diagnostics.Process.Start("Winword.exe", FileName);
    can any body please help for this.
    where i am making mistake?

Maybe you are looking for

  • Automatic PO creation during goods receive - free of harge PO item

    Hi, I am trying to automatically create a free of charge PO item during goods receive. Using movement type 511 and activating the "automatic PO"  setting in the customizing does not seem to do the job? Thanks Jens

  • Voice memo won't sync!! and won't let me email either!

    believe me, i've got all settings correct. I've been using voice memo for a long time and now for the first time it just won't sync at all i've noticed lately that sometimes the voice memo doesn't sync, I thought I operated wrongly, synced the iphone

  • I need to send a formal complain to apple. how can i do this?

    Please could anyone gave me an email to contact applec to send a formal complain to them

  • Non-Apple WiFi router

    I am eager to set up a standard WiFi station in my house. I purchased a D-Link $40 DIR 601 Wiresless N Home Router. Using the automatic net setup from system prefs, restarting router and cable modem, the network connection runs for a while but needs

  • Help with formula that is dependent on checkboxes

    Hello - I can't figure out this one for the life of me... In column A there is a list of tasks, column B has check boxes for each task. Column C has the starting day number of each activity, and column D has the duration of each activity. I'd like to