OpsMgr 2012 - Alerting question/discussion

Good day all.
I am trying to get community feedback regarding this issue.
I will state right off the bat that I WISH I COULD DO DYNAMIC EXCLUSIONS INSIDE GROUPS!!!! There, I said it :)  I can exclude individual servers, but I cannot exclude dynamically the same way I can include
dynamically.
 (my network is much much larger than this but it works for the description) 
Here is a scenario. I have a Production Network with 10 servers on it.  They are all windows based machines.  5 of them are QA servers which access the live data but are used for other things.  I want to email alert for the Windows servers
but NOT for the QA servers.
Ideally I would like to create 2 groups.  One group would be dynamically populated and contain "Windows Servers" (which would include all 10 systems).
The second group would be dynamically populated and contain only the 5 QA systems.
Then I would take that second group, and place it in the Excluded Members list of the Windows Servers group.  Upon which time I would setup an e-mail alert for Windows Computers and never again worry about another issue being emailed out which is related
to the QA servers.
Unfortunately that's not the case (although, if you have a way I can do this, I'd be grateful).
Thanks for any suggestions you have in advance.
Zach

Hi,
try this:
<Expression>
      <Or>
         <Expression>
             <NotContained>
                <MonitoringClass>$MPElement[Name="UIName.A.Group"]$</MonitoringClass>
             </NotContained>
         </Expression>
         <Expression>
             <NotContained>
                <MonitoringClass>$MPElement[Name="UIName.B.Group"]$</MonitoringClass>
             </NotContained>
         </Expression>
      </Or>
</Expression>
Regards,
Ivan

Similar Messages

  • What is the minimum permission set required to query alert information using OpsMgr 2012 SDK?

    Hi,
    I am using the OpsMgr 2012 SDK to retrieve alert information from SCOM.
    I tried configuring a read-only role for a user account (Group Scope: All, Dashboards & Views: All) but, as I call some of the APIs like Administration.GetAllManagementServers(), Administration.GetAllAgentManagedComputers() etc. I get a UnauthorizedAccessEnterpriseManagementException.
    I need to know what are the minimum permissions required for a user to query alert information and to make calls I mentioned above using the OpsMgr 2012 SDK.
    Warm Regards
    Himanshu Agarwal

    Thanks for the reply.
    Just to give you a context, I am writing a client application where a user can fetch alert information from SCOM using OpsMgr 2012 SDK. There could be many users that would use this application, hence I need to know the minimum set of permissions I can grant
    or add them to a group for easy maintenance.
    I believed Read-Only admin role was intended for that purpose but some of the SDK APIs as I mentioned throw the said exception.
    I would like to know, how can i create such role/group from SCOM 2012 console.
    PS: SDK and Config account is used by SCOM to perform DB operations and I would not like to impersonate this account in my client application. Instead I want to make my clients as admins with just enough permissions to read information. I'll have a better
    control this way.

  • Customize OpsMgr 2012 SP1 Web Console settings

    Hello all, 
    The question I have I've been seaching for days and I wasn't able to find nothing so I decided to ask here and hopefully there's someone
    whose already did it.
    I'm found some divergences on the number of alerts webconsole shows compared to scom console (UI). 
    Due this issue I spent hours of research on blogs and foruns until I find a blog post from Michael Pearson (link below) that list
    a bunch of settings you can add to web.config file, allowing you to choose which interval and which kind of alerts you want to display (critical, critical and errors or critical, errors and information), among others. I tried to make it work on my lab environment
     but these parameters seems to be incompatible with OpsMgr 2012.
    http://blogs.technet.com/b/michaelpearson/archive/2009/11/30/opsmgr-r2-web-console-web-config-settings.aspx
    Does anyone know if similar customization is available on OpsMgr 2012?
    Regards

    You should modify the web.config file under
    c:\program files\Microsoft System Center 2012 R2\operations Manager\webconsole\monitoringview
    Roger

  • SCOM 2012 Design questions?

    While design SCOM 2012 , what are important things to be noticed ? like Environment to be monitored , Budget , Network Bandwith , Application to be monitor ..etc
    Like this any other important things to be noticed. 

    For SCOM Design, you can check below links
    http://technet.microsoft.com/en-us/library/jj593271.aspx
    http://blogs.technet.com/b/momteam/archive/2012/04/13/opsmgr-2012-design-guide.aspx
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • OpsMgr 2012 R2 environment, reports in newly imported MPs not deploying to reporting services

    We have an OpsMgr 2012 R2 environment that has been up and running for several months now. Recently we attempted to import a new MP with reports (the Veeam Report Library) - the import was successful, but the Veeam folder and reports never appear in the
    OpsMgr reporting console or in the report server web page, even after waiting several hours and even overnight.
    We have deleted and reimported the MP with no luck. We have restarted the SRS server with no luck. We have scoured the logs of the servers and found no events that appear to be related, and there are no health states or alerts in OpsMgr indicating any issues.
    We also tried importing a new, different management pack with reports (Windows Logical Disk extension pack) and those reports also have not shown up.
    Note that for both MPs the associated rules/monitors show up as expected, it is only the reports that are an issue. Also, all the previously imported reports are still available and functioning normally, it's only newly-imported reports that are failing
    to show up.
    We previously imported dozens of MPs with no issues and there have been no configuration changes to the environment. With no OpsMgr alerts or health issues, and no seemingly related event log entries we're not sure where to check next to see the progress,
    status, and issues with report deployment, any help in pointing us in the right direction is appreciated.

    Hi,
    Would you please restart data access service and system center management configuration service to check the result?
    In addition, have you checked the operation manager event logs with event viewer, we may find helpful information there to troubleshoot this issue.
    Regards,
    Yan Li
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Adding Company Knowledge with OpsMgr 2012 Console - "Failed to launch Microsoft Word"

    Hi everyone!
    I'm trying to add company knowledge using the OpsMgr 2012 console (32-bit) on Windows 7 Ultimate (32-bit) using the guidelines provided at the following link...
    http://technet.microsoft.com/en-us/library/hh212900.aspx
    I'm using Office 2010 Pro Plus SP1 (32-bit) with the .NET Programmability feature and the Microsoft Visual Studio 2005 Tools for Office Second Edition Runtime installed, but I get the dreaded "failed to launch Microsoft Word" error...
    ...any help or guidance would be greatly apprecaited!
    Regards,
    JJ

    Thanks Andres!
    I have confirmed that the following instructions does allow you to use Word 2010 32-bit running on Windows 7 64-bit or Windows Server 2008 R2 to edit company
    knowledge...
    1. Go to the directory where the OpsMgr console is installed (example: C:\Program Files\System Center\Operations Manager 2012\Console )
    2. Make a copy of Microsoft.EnterpriseManagement.Monitoring.Console.exe.config
    3. Edit Microsoft.EnterpriseManagement.Monitoring.Console.exe.config using Administrator rights
    4. Search for “</dependentAssembly>” and remove the “<publisherPolicy apply="no" />” line immediately following the “</dependentAssembly>” line
    Hope this helps!
    Regards,
    JJ
    Well, firstly I have to agree with other people's comments along the lines of "It shouldn't be this hard!", but I can happily say that the solution above (by IM5FOOTNOTHIN)
    worked for me...once I noticed this crucial footnote: "Do this for
    ALL instances of the
    <publisherPolicy apply="no" /> line that immediately follow the </dependentAssembly> line"

  • Monitoring SAN through OpsMgr 2012 R2

    Hello All..................I am trying to monitor SAN through OpsMgr 2012 R2.
    1.  What would be required for such a configuration?  I have following
    -   Management Pack for SAN
    -   IP Address
    -   User Name and Password
    2.  WHat would be high level steps?  Any step by step guide would be appreciated.  THanks.

    You have to share more information...
    What storage?
    What tapes?
    What switches/directors?
    To monitor your devices as network devices you just need SNMP ports (161/162) and ICMP enabled. Minimum requirement is SNMP get for the discovery and monitors/rules that poll the device.
    Cheers,
    Patrick
    Please remember to click “Mark as Answer” on the post that helped you.
    Patrick Seidl (System Center and Private Cloud)
    Website: http://www.syliance.com
    Blog: http://www.systemcenterrocks.com

  • SCOM 2012 alerts fine tuning

    Hi,
    How to fine tune SCOM 2012 alerts we are getting huge amount of alerts , to stop unwanted alerts and how to customised what is being monitored ?
    Thanks.

    There are a number of posts which provide recommendations.
    https://dynamicdatacenter.wordpress.com/tag/scom-alert-tuning/
    http://blogs.technet.com/b/kevinholman/archive/2009/12/21/tuning-tip-do-you-have-monitors-constantly-flip-flopping.aspx
    You could tackle each alert and tune as you get them but if you want to be more productive run some of the alert reports and have a look at where the noise is coming from. You will probably find a handful of culprits.
    Also if your getting a lot of Powershell scrips failing or timing out or wmi failing, these sometimes are just random failures if the server is to busy or backup running or AV.  One of the steps I have taken is to make these alerts informational and
    then have our operations team check once a day for any problematic servers that are reporting multiple issues or specif scripts failing multiple times. 
    http://blogs.technet.com/b/kevinholman/archive/2009/06/29/getting-lots-of-script-failed-to-run-alerts-wmi-probe-failed-execution-backward-compatibility-script-error.aspx
    Its a big task if this hasn't been actively done and will take some time. (Once it has been done keep reviewing regularly)
    Cheers,
    Martin
    Blog:
    http://sustaslog.wordpress.com 
    LinkedIn:
    Note: Posts are provided “AS IS” without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and/or fitness for a particular purpose.

  • [OpsMgr 2012 SP1 RU1] Network Devices disappeared

    Hello,
    I have enabled network monitoring on my OpsMgr 2012 environment.
    I created explicit discovery rules to discover around 20 newtork devices
    There are two CISCO 6506 switches running in pair with IP address 172.x.x.117 and 172.x.x.118
    Both switches are discovered and under monitored successfully, I can monitored the Proccessor usage, ports, etc
    However, after sometime, the 172.x.x.117 switch disappeared from the console.
    I tried to re-discover it, but it eventually disappeared again.
    Please help on this issue, is it a bug or something? the second swtich 172.x.x.118 is being monitored normally without any issue
    Thank you very much

    I have the same problem, but the network device thats disappears for me is a windows server 2008 R2 that I have added as a network device.

  • SCOM 2012 Alerts for Ping Network Device

    Hi
    I have SCOM 2012 and configure Rule for Ping my Network Device.
    My question is, How to Configure Alert for send mail when timeout is detected on Rule?. Step by step documentation? I see tab Alerts on the monitor but Generate Alerts option is greyed out. 
     thanks.

    More info:
    How to test email notification settings in Operations Manager
    https://support.microsoft.com/kb/934756?wa=wsignin1.0
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • HP Expert Day - April 18, 2012: Got Questions? Ask the HP Experts!

    Thank you for coming to Expert Day – the event has now concluded.
    **To find out about future HP Expert Day events, check out this page**
    On behalf of the Experts, I would like to thank you for coming to the Forum to connect with us.  We hope you will return to the boards to share your experiences, both good and bad.
    We will be holding more of these Expert Days on different topics in the months to come.  We hope to see you then!
    If you still have questions to ask, feel free to post them on the Forum – we always have Experts on the HP Support Forum to help you out.
    Do you have questions using or setting up your notebook, desktop PC, or printer?
    We’ll, we’ve got answers.
    Experts will be on the notebook, desktop, and printer and all in ones boards ready to answer your questions from Wednesday, April 18th 7:00am to Thursday, April 19th 7:00am Pacific Standard Time.
    How the day works:
    Come to the Forums and ask your questions. More than 200 experts will be on the Forums and will do their best to answer your questions and help you out. They may need to get some more information from you so please check the box "email me when someone replies."  An online conversation will be born!
    Why should you come to the Forums?
    Whether you own an HP Envy notebook, Photosmart printer, or an HP home desktop computer, there has never been a better chance to learn about your product.
    When do you have a chance to talk directly with the people who designed the product or wrote the manual for it?
    This will be your opportunity to connect with the best and brightest minds at HP for free.
    We’ll share our knowledge on the best ways to:
    Troubleshoot the issue you are having;
    Tweak your product to increase performance;
    Set up a Wireless network;
    Safeguard your PC from viruses and spyware;
    Choose the right power supply, upgrade your video card, or add the right amount of memory;
    Use the tools built into your product that can make it run better and fix common problems.
    And it’s FREE.
    It doesn’t matter how old the product is or what it is connected to. We will do our best to help.
    Expert Day will also be occurring on these forums:
    Enterprise Business Forum (April 18th from 7:00am to April 19th 7:00am PDT)
    French Forum (April 18th – 10am - 8pm Central European Time)
    German Forum (April 18th – 10am - 8pm Central European Time)
    Portuguese Forum (April 18th – 9am - 7pm Brasilia Time)
    Spanish Forum (April 18th – 9am - 7pm Buenos Aires Time)
    Hope to see you on April 18th!
    I work for HP, supporting the HP Experts who volunteer their time and technical knowledge to help others.
    --Say "Thanks" by clicking the Kudos Star in the post that helped you.
    --Please mark the post that solves your problem as "Accepted Solution"

    My HP, purchased in June 2012, died on Saturday.  I was working in recently installed Photoshop, walked away from my computer to answer the phone and when I came back the screen was blank.  When I turned it on, I got a Windows Error Recovery message.  The computer was locked and wouldn't let me move the arrow keys up or down and hitting f8 didn't do anything. 
    I'm not happy with HP.  Any suggestions?

  • Hyper-V Server 2012 Migration Questions

    Hello All,
    This is my first post here, but I have used these forums many times for information. Sorry in advance for the long post.
    I have a few questions regarding migration to Hyper-V server 2012 for my production environment. I have done quite a bit of reading, but I have a few direct questions and I would like to get some direct answers.
    My current production environment consists of one PowerEdge 2900 with 2 Xeon X5460 Quad Core 3.16GHz CPUs, 24 GB of RAM and a RAID 10 consisting of 8, 500 GB HDDs for a total of 2TB of storage. I am currently running Server 2008 R2 Enterprise w/ GUI as the
    Hyper-V host OS. I have 4 virtual machines all also running Server 2008 R2 Enterprise. The 4 virtual machines consist of 1 domain controller, 1 Exchange Server with Exchange 2010 Standard, 1 Server running SharePoint 2010 Enterprise and the remaining server
    running IIS with FTP and HTTP.
    The network topology is as follows….
    Hopefully it is clear from my diagram that the Hyper-V host OS is connected to the same physical network as the domain, but is not a joined to the domain. I set it up this way because I had concerns about connectivity and manageability because the domain
    controller is a guest VM. Also, the IIS server is on a completely different physical network independent of the domain.
    What I would like to accomplish is the migration of the above environment to Hyper-V Server 2012 as is. I want to keep my existing guest VMs unchanged and running Server 2008 R2 for now as well as keep the existing network topology intact.
    I have 3 additional servers in a separate test environment that would be able to serve as temporary storage or whatever is needed for the migration process.
    Here are the two main things I would like to accomplish with this migration…
    1. Make the transition from Server 2008 R2 to Hyper-V Server 2012 as a host OS.
    2. Migrate virtual hard disks from .VHD to the new .VHDX format.
    All that being said, I have finally come to my questions regarding this process.
    First and foremost, I would obviously need to back up my current setup in case something goes horribly wrong during the migration. My question regarding the initial backup is would it be better to do a bare metal backup of the Hyper-V host or should I do
    individual backups (bare-metal?) of the Guest VMs from within their operating systems?
    Second, since I plan to use Hyper-V Server 2012, I will have to manage the host OS using the RSAT from a domain joined client running Windows 7 Professional. How much of a pain is it going to be to setup RSAT and manage the non-domain joined host from a
    domain joined client? Is there a better way without using SCVMM or using Server 2012 w/ a GUI as the host OS?
    Third, are there any concerns I should have, precautions I should take or procedures I need to do before, during or after the migration regarding the existing VMs and the new virtualized hardware environment on the same physical host?
    Forth, should I use the trial version of SCVMM 2012 SP1 (or another previous version) to perform the migration? What should I be aware of using SCVMM for the migration and then discontinuing its use after the migration is complete and moving to management
    using the RSAT?
    Fifth, if I don’t use SCVMM for the migration, what is the best procedure for moving the VMs? Should I just copy the VHDs to a temporary storage location, install Hyper-V server 2012, copy the VHDs back, create new VMs and attach the VHDs or should I use
    the export/import process?
    Number six, when is the best time to migrate the VHDs to VHDX format and what would be the best method?
    And finally, do I need to worry about USN rollback with a single domain controller? From my reading, this seems to be a point of disagreement. Some people say it could happen while others say it won’t. Is there any point during the migration process where
    it could occur either during the copying of VHDs or from the switch to VHDX?
    Again, sorry for the long post and thanks for staying with me this far. Any information would be much appreciated

    1) As Jens said below with Windows Server 2012 you can simple copy the configuration files and VHDs from a 2008 R2 server to a 2012 server and import them - they one caveat to this is that any vlan configuration is lost and you have to simply re-create it. 
    Optionally you can also export the virtual machines from Windows Server 2008 R2 and then import them on Windows Server 2012.
    2) Remote management in a workgroup does have some caveat's associated with it - take a look at
    http://blogs.technet.com/b/jhoward/archive/2009/08/07/hvremote-refresh.aspx.  Generally I would recommend joining the Hyper-V management operating system to the domain - not just because of these issues but for a number of other features to work properly
    (see below)
    3) I always recommend validating the hardware and environment after the installation before migrating critical workloads to it - testing networking, backup etc... to make sure they function as expected.  Also ensure that you upgrade the integration
    components in the VM's after the migration.
    4) That is an option - though you might find you like SCVMM
    5) Recreating VM's using existing VHD's has some issues for example the BIOS GUID changes, all of the NIC's are re-plug and played etc... When possible copying the configuration or using export is much better.
    6) The sooner the better - VHDx has a number of significant advantages, you can do the migration using the Hyper-V manager UI (edit disk) or via powershell with Convert-VHD.  Do keep in mind that during the conversation you need 2x the space (for the
    original and the new VHDx).
    7) In the past you could get into trouble if you for example snapshotted an AD virtual machine and than reverted it - taking one offline and then brining it back online was never a problem.  In Windows Server 2012 we addressed this with a feature called
    generation ID's.
    Domain considerations...  A few things to keep in mind regarding the choice to not domain join the Hyper-V server.
    - You can't live migrate virtual machines
    - You can't utilize Hyper-V over SMB
    - Management is more difficult and less secure
    -Taylor Brown -Program Manager, Hyper-V -http://blogs.msdn.com/taylorb

  • WDS & MDT 2012 Integration Questions: Do I need an install image on WDS if I'm multicasting from MDT

    I'm running WDS & MDT 2012 on Server 2012 for my deployment solution.  I have a few questions about what happens when you integrate WDS & MDT.
    Perhaps this is a simple question, but if WDS multicasts the installation image from MDT, do I need to have an image in the installation folder of WDS?  I have the "Enable multicasting" box checked whenever I update my deployment share
    Also, my server is running X64 architecture, so I have the x64 WAIK installed.  but I'm having issues editing the unattend.xml on my server because my images are all X86.  Keeping in mind that I already have the X64 WAIK installed, can i install
    the X86 WAIK tools on my server?

    Sorry, that's two questions you only get one... Just kidding...
    FOr MDT, you don't import the images into the WDS console, you just need to add a Multicast namespace.
    http://keithga.wordpress.com/2014/04/23/multicasting-with-mdt/
    AS for the unattend.xml edit issue, that is known:
    http://blogs.technet.com/b/deploymentguys/archive/2009/08/27/windows-7-waik-and-custom-images.aspx
    Keith Garner - Principal Consultant [owner] -
    http://DeploymentLive.com

  • CCMS ALERT QUESTION

    Hi,
    I am using XI 3.0, and trying to setup CCMS alert setup...
    I have 2 quesitnos: first
    I done XML alerts using ALRTCATDEF and create alert XDV_XML category, then RWB define add roles in there, all XML messages comes in mail which is good!!!
    but when I goto  RZ20 and find SAP CCMS Monitor Template and double click under "Exchange Infrastructure"  its shows there but empty or disable or white color can't see anyting under that .... WHY?
    2nd question; I am tyring to create CCMS alert goto RZ21 click mothod -> display overview -> select mothod CCMS_Online_Email -> copy this mothod to my name like CCMS_TRAVIS
    In Execution tab -> type of call alerady select funcation module and call selected: SALO_EMAIL_IN_CASE_OF_ALERT
    In Control Tab -> Periodically in dialog process (shot running program) selected
    In Parameter Tab -> SENDER: my user name, RECIPIENT: my eamil address, RECIPIENT TYPE: U
    In Release Tab -> selected 'auto reaction mothod'
    what i do next, what kind of alerts will show there? and how? and when? and if i want show thease alert for more user how do i setup?, and why only CCMS_OnAlert_Eamil only ?,
    Please can you give me answer in your words, I have lot of URL but not help full
    Thanks a lot

    Hi, there
    I already have that doc. thanks a lot anyway!!! ok if I am following this doc.
    /people/sap.user72/blog/2005/11/24/xi-configuring-ccms-monitoring-for-xi-part-i
    Step 3 : Creating a System Group for SAP Exchange Infrastructure
    When I goto Rz21 and click "Technical infrastructure" then "configure central system" then "maintain system group" and click "Maintain gropus" then create Groups" its asking me new entry put "ExchangeInfrastructure_Systems" now how its look like :-
    System Groups for Alert Monitor
    46C_Systems
    620_Systems
    640_Systems
    700_Systems
    <SYSTEMS_WATCHED_BY_4XAGENTS>
    ADABAS D_Systems
    CSM_Known_Systems
    INFORMIX_Systems
    J2EE_Systems
    ORACLE_Systems
       ExchangeInfrastructure_Systems   (This entry has been created but under oracle_system and with not yellow folder)
    Note: when I goto rz20 and click CCMS_Monitor_template it does show Exchange Infrastructure but grayedout nothing display under exchange infrastructure.... WHY?
    please some advised
    Thanks

  • System Center 2012 license question

    Hi all, a general question regarding system center 2012 software assurance (didn't find any appropriate thread hence posting this here as SCCM is the main component in the suite)
    Q: I came across 'software assurance' in the licensing document which is part of system center 2012 suite purchase (STD or DC edition). I wanted to know if we would like to extend the SA period beyond the first 3 years, how it works? Do we need to extend
    the contract for an additional 3 year term (product suite + SA) or an annual basis?
    thanks!

    https://www.microsoft.com/licensing/servicecenter/Help/Contact.aspx
    John Marcum | http://myitforum.com/myitforumwp/author/johnmarcum/

Maybe you are looking for

  • Actual quantity in service tab page becoming zero after updation

    Dear friends, We updated validity start date, end date in header and the field "form.val.2" in service tab page in item details of a service line item(item category D) in a Purchase order using the function module 'BAPI_PO_CHANGE'. After updation we

  • Problem with WS_FILENAME_GET

    I'm using ws_filename_get in my modul-pool application on event PROCESS ON VALUE REQUEST. The point is that i always get SELECTION_CANCEL exception. Has anyone got an idea?? Is there any similar function module???

  • Second list depending on first on when-list-changed

    Hello! I'm having some trouble with 2 poplists. First poplist (:bloc_portar.lista) is generated ok. Second poplist (:bloc_portar.cnp) depends on the values of the first like this: DECLARE      nume_lista1 varchar2(60) := replace(:bloc_portar.lista, '

  • Simplified Chinese characters changed

    Dear sir, We are using SAP 4.6B with code page 8300 (ZF). I know we cannot recognize simplified Chinese characters, but we still can receive them and store them into our table without change any codes when our client transmit data from EDI. But recen

  • Entering HTML Entity Codes

    I haven't been able to find a way to insert HTML entity codes (specifically, to use em dashes, but other needs arise) through the interface. HTML snippets are intended for something entirely different. Apart from opening published output in an editor