Port Channel 5548 with 6509

My company just purchased a Nexus 5548.  I've been fooling around with the configurations and just getting familiar with this equipment.  I've already configured a port channel using 2 10gig ports on our 3850 and its working fine.
Now, I'm trying to configure a second port channel with our 6509 1gig ports. Ports comes up. But I cannot communicate between these 2 devices.
Show CDP Neigh shows the other devices. Show Etherchannel summary is blank
This is the config on the 6509
interface Port-channel22
 switchport
 switchport trunk encapsulation dot1q
 switchport mode trunk
interface GigabitEthernet9/7
  switchport
 switchport trunk encapsulation dot1q
 switchport mode trunk
 channel-group 22 mode on (I also tried using Active and desirable)
Config on 5548
Inteface Port-Channel 2
switchport
 switchport mode trunk
 speed 1000
interface ethernet1/32
 switchport mode trunk
 speed 1000
 channel-group 22 mode on
I also have feature Lacp , interface vlan and vlan dot1q tag native enabled
Any ideas why I cannot communicate between these devices? 

This is what is showing on the 5548
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-SPEED: Interface Ethernet1/32, operat
ional speed changed to 1 Gbps
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/32, op
erational duplex mode changed to Full
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Etherne
t1/32, operational Receive Flow Control state changed to off
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Etherne
t1/32, operational Transmit Flow Control state changed to off
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-SPEED: Interface port-channel2, opera
tional speed changed to 1 Gbps
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_DUPLEX: Interface port-channel2, o
perational duplex mode changed to Full
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface port-ch
annel2, operational Receive Flow Control state changed to off
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface port-ch
annel2, operational Transmit Flow Control state changed to off
2015 Mar 18 08:18:09 DC-5548-01 %ETH_PORT_CHANNEL-5-PORT_UP: port-channel2: Ethe
rnet1/32 is up
2015 Mar 18 08:18:09 DC-5548-01 %ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel2:
first operational port changed from none to Ethernet1/32
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_UP: Interface Ethernet1/32 is up i
n mode trunk
2015 Mar 18 08:18:09 DC-5548-01 %ETHPORT-5-IF_UP: Interface port-channel2 is up
in mode trunk
My 6509 does not show anything. Now when I do  a show etherchannel summary on the 6509, the protocol is lacp.

Similar Messages

  • 8Gig Port Channel between two 6509s

    Hey all,
    I have two 6509s that I'm trying to configure an 8 Gig trunk/port channel. I have an 8 port fiber module in slot 3 on both switches. When I use the following command: "set port channel 3/1-8" on it seems to take the command, but if I do "show port channel" it shows two groups:
    3/1-4
    3/5-8
    Is there a limit as to how many gigs a port channel can be? If not, why does it split it like this?
    I should also note I'm using dot1q for the trunks using Auto mode on one switch and Desirable on the other.
    Thanks,
    Scott

    I did a show port cap on the interfaces and I didn't see any sort of restriction. I decided to run the command again 'set port channel 3/1-8 on' and for some reason it seemed to work this time. Not sure what changed, but it's working now.
    Thanks for your help!

  • Port channel configuration with VMware

    Hi everyone, I have dual 6120 interconnects, each of which have two uplink ports. I also have two Catalyst 4900M switches to uplink to. So I plan to configure both 802.1q and 802.3ad on each of the 6120 uplink pairs. My question relates to the physical cabling, bearing in mind ESX will be running on the blades.
    Would you cable both the uplink ports on interconnect 1 to switch 1? Or would you cross-connect them to both switch 1 and switch 2?
    As per this article I see ESX does not support splitting a port channel across two switches, but I am unsure how the presence of the 6120s affects this. Can anyone suggest the best way of doing the cabling based on the kit I have? Thanks.
    http://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=1001938&sliceId=1&docTypeID=DT_KB_1_1&dialogID=14912551&stateId=1%200%2014916516

    Hey Simon, let's address this is two parts because there are two layers: server-bound (ESX-6120) and north-bound (6120-Cat4900).
    At the ESX end, use the default srcPort in the vSwitch / port group with both 10GbE uplink ports (vmnic0 and vmnic1) set to active (not active/passive).  There are no loops in this configuration.  On the VNIC (in UCSM) you select trunk port and allow all the VLANs that your vSwitch port groups needs.  If you don't use a VLAN for the Service Console/ESXi Management, then make sure you set Native to the correct VLAN in the VNIC to allow untagged traffic down the right path.
    At the 6120 you can't explicitly configure a trunk for border ports, they are already set so and when you add VLANs they are added to every border port trunk configuration.  You, of course, need to make sure the Cat4900 ports at the other end of the cable have the same trunkport VLAN configuration.
    So in summary - set VLANs in vSwitch port groups, VNIC in UCSM and northbound switch. 
    Now when it comes to port channels, you can only configure two or more border ports as a port channel if they are cabled to the same Cat4900.  If you had Nexus 5k/7k northbound then you could use vPC on them to allow "mesh" cabling (ie. one 6120 connects to both Nexus switches).  But as you aren't using Nexus you will end up with a configuration as Jeremy explained:
    ESX --> vSwitch0 --> srcPort load balancing --> 2 active uplinks --> many port groups
    6120-a --> Cat4900-a
    6120-b --> Cat4900-b
    However, I would still recommend using a couple of border ports in a port channel on each fabric to each Cat4900 because, if you pull out a cable/lose a port, then when that port is re-enabled the existing live traffic is redistributed whereas without the port channel only new traffic will be spread across both links.
    Cheers
    Steve
    Cisco UCS Team

  • Port-channel problem with WiSM

    Has anybody met following similar problem:
    I put WiSM into slot 3(also tried slot 6) of 6506(sup720-3B, s72033-adventerprisek9_wan-mz.122-33.SXH.bin), using following command to setup the port-channel:
    interface Port-channel1
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 5
    switchport trunk allowed vlan 1-1000
    switchport mode trunk
    int range g3/1-4
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 5
    switchport trunk allowed vlan 1-1000
    switchport mode trunk
    channel-group 1 mode on
    I can use "session slot 3 pro 1" to login to the WiSM, but can't ping WiSM's management IP address from 6506, then I find the port-channel has problem, only G3/1 is up and included in the channel, G3/2-4 are up but line protocol is down, then I found from the log that: "AESUT: %EC-SP-5-CANNOT_BUNDLE2: Gi3/2 is not compatible with Gi3/1 and will be suspended (qos-card type unavailable for Gi3/2 or Gi3/1)". It says those GE port are not compatible for qos-card type, but I checked the configuration, all GE using the same configuration. Don't know why, maybe a bug? Appreciate for any feedback

    I have the same problem, but it has something to do with QoS. When you disable "mls qos" on the switch, the port-channel will function normal again.
    It doesn't help when you configure "mls qos trust dscp" on the port-channel!!!!!

  • Port-channel issue with FI-N7k using rate-mode share

    Hi Dears,
    I'm trying to using port-channel between Fabric Interconnect (FI) and N7K. in N7K use rate-mode share and LACP but the port-channel in N7K was suspended.
    I was trying :
    1. I using non dedicated port in Nexus 7010.
          - rate-mode share
          - channel-group 1 mode active
          - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was suspended
    2. I using non dedicated port in Nexus 7010
         - rate-mode share
         - channel group 1 mode on
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was came up, but in Fabric interconnect was failed.
    3. I using dedicated port in Nexus 7010
         - rate-mode share
         - channel group 1 mode active
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was suspended
    4. I using dedicated port in Nexus 7010
         - rate-mode dedicated
         - channel group 1 mode active
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was came up and running well.
    is any other way to configure port-channel in N7K with rate-mode share and LACP ?
    or it's some of limitation in port-channel when using rate-mode share at N7K ?
    nb: fabric interconnect only support LACP and cannot be configurable.
    regards,
    Berwin H

    HI Mark,
    1. Can you please check your ethernet card ...where this port channel connected..on the server.
        may be there are 2 different card.
    2. from cisco websites:
    Error Message
    Explanation
    This port has different port attributes than other ports within the port channel.
    Recommended Action
    Match the port attributes to that of the port channel.
    Regards
    Please rate if it helps.
    Match the port attributes to that of the port channel.This port has different port attributes than other ports within the port channel.
    EC-5-CANNOT_BUNDLE_LACP: [char] is not compatible with aggregators in
    channel [dec] and cannot attach to them ([char])

  • LACP port channel between 6509 and Nexus 7K

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

  • How to configure a port channel with VLAN trunking (and make it work..)

    We're trying to configure a port channel group with trunked ports to connect a NetApp HA pair. We want to create two data LIFs and connect them to the switch stack.  We are trying to create 2 data lifs, one for cifs and one for nfs that are on different vlans.
    We want the same ports to be able to allow multiple vlans to communicate. (trunked)
    These data lifs should be able to fail over to different nodes in the HA pair and still be able to communicate on the network.
    What this means is that we have to connect 4 ports each for each node in the NetApp HA Pair to the switches and create a port channel of some type that allows for trunked vlans. When we configure the ports, the configuration is as follows (below):
    We are only able to configure an IP on one of the vlans.
    When we configure an IP from another vlan for the data lif, it does not respond to a ping.
    Does anyone have any idea what I'm doing wrong on the Cisco switch?
    interface GigabitEthernet4/0/12
    description Netapp2-e0a
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet4/0/13
    description Netapp2-e0c
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/12
    description Netapp2-e0b
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/13
    description Netapp2-e0d
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    spanning-tree portfast
    spanning-tree bpduguard enable
    end

    Our problem was fixed by the storage people.  They changed the server end to trunk, and the encapsulation / etherchannel.
    I like all the suggestions, and they probably helped out with the configuration getting this to work.
    Thanks!
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    interface GigabitEthernet4/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet4/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active

  • Port-Channel Help

    So, I had some trouble yesterday with creating some port-channels and was wondering if anybody has seen this before. I created a port-channel from my 6509 to a 4506 and tried to add two interfaces in an active mode. A couple things happened:
        1. Received an error " %EC-SP-5-CANNOT_BUNDLE_LACP: Gi4/11 is not compatible with aggregators in channel"  which i can't seem to figure out why.
        2. I do have spanning-tree on the interfaces connecting but what happened was the port-channel came up with one interface in it and the other interface came up...both in a forwarding state. This cause a big loop as these were trunk ports and brought down the network. 
        3. Interfaces went down, but never came back up setting leaf switch all over in an errdisable state.
    Can anybody help with any of these? Thanks

    Hi,
    Check whether flow control is on all ports in module 4.if some of the ports are off.kindly make sure to enable on.
    Use below command to check flow control status:
    switch-a#sh int flowcontrol module 4 
    regards
    Moorthy

  • Port-channel question on 9148

    hey I have a question about  port-channel.
    we have a port-channel 10 which contains 4 interfaces as below.
    my question is how the port-channel associated with the servers?  I mean the output "sh flogi database" as below........
    do we need to add port-channel as a zone member ? I think the answer is no since I don;t see the port-channel as a zone member....
    =================================================================
    tormds01# sh interface port-channel  10
    port-channel 10 is up
        Hardware is Fibre Channel
        Port WWN is 24:0a:54:7f:ee:a0:d5:48
        Admin port mode is auto, trunk mode is on
        snmp link state traps are enabled
        Port mode is F
        Port vsan is 510
        Speed is 32 Gbps
        5 minutes input rate 124316072 bits/sec, 15539509 bytes/sec, 9919 frames/sec
        5 minutes output rate 2205921104 bits/sec, 275740138 bytes/sec, 141424 frames/sec
          43540499847 frames input, 70772376296224 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          237450525827 frames output, 442040501099476 bytes
            0 discards, 0 errors
          0 input OLS, 0 LRR, 0 NOS, 0 loop inits
          0 output OLS, 0 LRR, 0 NOS, 0 loop inits
        Member[1] : fc1/1
        Member[2] : fc1/5
        Member[3] : fc1/9
        Member[4] : fc1/13
        Interface last changed at Tue Apr  8 22:16:49 2014
    tormds01# sh flogi database
    INTERFACE        VSAN    FCID           PORT NAME               NODE NAME      
    fc1/3            510   0x860000  50:06:01:64:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spa0]
    fc1/7            510   0x860100  50:06:01:6c:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spb0]
    fc1/11           510   0x860200  50:06:01:60:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spa2]
    fc1/15           510   0x860300  50:06:01:68:3d:e0:24:d0 50:06:01:60:bd:e0:24:d0
                               [torvnx01_spb2]
    port-channel 10  510   0x860400  24:0a:54:7f:ee:92:3e:80 21:fe:54:7f:ee:92:3e:81
    port-channel 10  510   0x860401  20:01:04:25:b5:3a:00:8f 20:01:00:25:b5:30:00:8f
                               [mcvhes0101hba0]
    port-channel 10  510   0x860402  20:01:04:25:b5:3a:00:9f 20:01:00:25:b5:30:00:9f
                               [mcvhes0102hba0]
    port-channel 10  510   0x860404  20:01:04:25:b5:3a:00:6f 20:01:00:25:b5:30:00:6f
                               [mcvhes0103hba0]
    port-channel 10  510   0x860408  20:01:04:25:b5:3a:00:7f 20:01:00:25:b5:30:00:7f
                               [mcvhes0104hba0]
    port-channel 10  510   0x86040f  20:01:04:25:b5:3a:00:4f 20:01:00:25:b5:30:00:4f
                               [mcvhes0105hba0]
    port-channel 10  510   0x860410  20:01:04:25:b5:3a:00:5f 20:01:00:25:b5:30:00:5f
                               [mcvhes0106hba0]
    port-channel 10  510   0x860417  20:01:04:25:b5:3a:00:2f 20:01:00:25:b5:30:00:2f
                               [mcvhes0107hba0]
    port-channel 10  510   0x860418  20:01:04:25:b5:3a:00:0f 20:01:00:25:b5:30:00:0f
                               [mcvhes0109hba0]
    port-channel 10  510   0x86041b  20:01:04:25:b5:3a:00:bf 20:01:00:25:b5:30:01:bf
                               [mcvhes0110hba0]
    port-channel 10  510   0x86041d  20:01:04:25:b5:3a:00:1f 20:01:00:25:b5:30:00:1f
                               [mcvhes0111hba0]
    port-channel 10  510   0x86041e  20:01:04:25:b5:3a:00:3f 20:01:00:25:b5:30:00:3f
                               [mcvhes0108hba0]
    port-channel 10  510   0x86041f  20:01:04:25:b5:3a:00:ff 20:01:00:25:b5:30:01:ff
                               [mcvhes0112hba0]
    port-channel 10  510   0x860423  20:01:04:25:b5:3a:00:df 20:01:00:25:b5:30:01:df
                               [mcvhes0113hba0]
    port-channel 10  510   0x860425  20:01:04:25:b5:3a:00:ef 20:01:00:25:b5:30:01:ef
                               [mcvhes0114hba0]
    port-channel 10  510   0x860426  20:01:04:25:b5:3a:00:cf 20:01:00:25:b5:30:01:cf
                               [mcvhes0115hba0]
    port-channel 10  510   0x860427  20:01:04:25:b5:3a:00:8e 20:01:00:25:b5:30:01:8f
                               [MCDBWS0200hba0]
    port-channel 10  510   0x860429  20:01:04:25:b5:3a:00:9e 20:01:00:25:b5:30:01:9f
                               [MCDBWS0201hba0]
    port-channel 10  510   0x86042a  20:01:04:25:b5:3a:00:7e 20:01:00:25:b5:30:01:7f
                               [mcvhes0118hba0]
    port-channel 10  510   0x86042b  20:01:04:25:b5:3a:00:af 20:01:00:25:b5:30:01:af
                               [mcvhes0116hba0]
    port-channel 10  510   0x86042c  20:01:04:25:b5:3a:00:6e 20:01:00:25:b5:30:01:6f
                               [mcvhes0117hba0]
    port-channel 10  510   0x86042d  20:01:04:25:b5:3a:00:4e 20:01:00:25:b5:30:01:4f
                               [mcvhes0119hba0]
    port-channel 10  510   0x86042e  20:01:04:25:b5:3a:00:5e 20:01:00:25:b5:30:01:5f
                               [mcvhes0120hba0]
    port-channel 10  510   0x860431  20:01:04:25:b5:3a:00:2e 20:01:00:25:b5:30:01:2f
                               [awotorprodsql01hba0]
    port-channel 10  510   0x860432  20:01:04:25:b5:3a:00:3e 20:01:00:25:b5:30:01:3f
                               [awotorprodsql02hba0]
    port-channel 10  510   0x860435  20:01:04:25:b5:3a:00:fe 20:01:00:25:b5:30:00:ef
                               [dbcactv01n3hba0]
    port-channel 10  510   0x860436  20:01:04:25:b5:3a:00:de 20:01:00:25:b5:30:00:bf
                               [dbcactv01n4hba0]
    port-channel 10  510   0x860439  20:01:04:25:b5:3a:00:ce 20:01:00:25:b5:30:00:8e
                               [mcvhes0123hba0]
    port-channel 10  510   0x86043a  20:01:04:25:b5:3a:00:be 20:01:00:25:b5:30:00:af
                               [mcvhes0122hba0]
    port-channel 10  510   0x86043c  20:01:04:25:b5:3a:00:ae 20:01:00:25:b5:30:00:9e
                               [mcvhes0124hba0]
    port-channel 10  510   0x860443  20:01:04:25:b5:3a:00:8d 20:01:00:25:b5:30:00:6e
                               [mcvhes0125hba0]
    port-channel 10  510   0x860445  20:01:04:25:b5:3a:00:ee 20:01:00:25:b5:30:00:cf
                               [mcvhes0121hba0]
    port-channel 10  510   0x860446  20:01:04:25:b5:3a:00:9d 20:01:00:25:b5:30:00:7e
                               [mcvhes0126hba0]
    port-channel 10  510   0x860447  20:01:04:25:b5:3a:00:6d 20:01:00:25:b5:30:00:4e
                               [mcvhes0127hba0]
    port-channel 10  510   0x860449  20:01:04:25:b5:3a:00:7d 20:01:00:25:b5:30:00:5e
                               [mcvhes0128hba0]

    I think what you do is F-Port trunking channeling !
    port-channel as a zone member ? I assume you will do pwwn based zoning; in which case the answer is NO !

  • FC Port Channel & Trunking

    Hi, Cisco Experts:
    Can I have a definitive answer to the following?
    q1.
    EMC mentioned that they do not support FC Port Channel & Trunking with regard to our UCS Fabric Interconnects/MDS/VNX5300?
    Is that any truth in that?
    We are trying a Cisco UCS solutions with MDS and EMC VNX in the mix-SAN Boot basically, ESXi 5.1 and all others.
    q2.
    From MDS all the ways up to EMC VNX, is there such concept too-FC Port Channel & Trunking, assuming we are doing FC Port Channel & Trunking from FInterconnect to MDS?
    Please let me know.
    Appreciate it.
    SiM

    Hi Sim,
    We support FC port channel and trunking between UCS FI and MDS.
    Is EMC saying about the port channel between the MDS and VNX? Is there any document EMC pointed out?
    With respect to booting from SAN, yes, you can boot from SAN with MDS and EMC VNX as long as the OS is supported in the UCS system. You can refer to
    http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html for the supported OS versions.
    Hope this answers your question.
    -Ganesh

  • Write all digitall ports (Channels) with decimal value

    Hi,
    it is possible to write all digital port with a decimal value for a device with 96 channels in the same time?
    I have a USB 6509 device and I want to write each bit whit value 1 in loop (for the first port I write 0,1,2,4,8,16, 32, 64 and 128) with line "Dev3/port0/line0:7", but if I want to write all the ports in the same time how to set the line and the "DAQmx write.vi"?
    Thank you.
    Solved!
    Go to Solution.
    Attachments:
    Untitled 1.vi ‏13 KB

    You can setup reading and writing in 8-bit ports with the 6509.  So you could just write 128 to "Dev3/port0".  If you want to write to all 12 ports, I recommend making a task that is multiple channels on the 6509 module, each channel in the task being a port.  You can then use the Multiple Channel, Single Sample to write your values.  Your values will need to be in an array of U8.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • UCS FI 6248 to Nexus 5548 San port-channel - not working

    Hi all,
    I'm sure I am missing something fairly obvious and stupid but I need several sets of eyes and help.
    Here is the scenario:
    I want to be able to create san port-channels between the FI and Nexus.  I don't need to trunk yet as I can't even get the channel to come up.
    UCS FI 6248:
    Interfaces fc1/31-32
    Nexus 5548
    interfaces fc2/15-16
    FI is in end-host mode and Nexus is running NPIV mode with fport-channel-trunk feature enabled.
    I'm going to output the relevants configurations below.
    Nexus 5548:
    NX5KA(config)# show feature | include enabled
    fcoe                  1         enabled
    fex                   1         enabled
    fport-channel-trunk   1         enabled
    hsrp_engine           1         enabled
    interface-vlan        1         enabled
    lacp                  1         enabled
    lldp                  1         enabled
    npiv                  1         enabled
    sshServer             1         enabled
    vpc                   1         enabled
    interface san-port-channel 133
      channel mode active
      no switchport trunk allowed  vsan all
      switchport trunk mode off
    interface fc2/15
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    interface fc2/16
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    NX5KA# show vsan membership
    vsan 1 interfaces:
        fc2/13            fc2/14          
    vsan 133 interfaces:
        fc2/15            fc2/16            san-port-channel 133
    vsan 4079(evfp_isolated_vsan) interfaces:
    vsan 4094(isolated_vsan) interfaces:
    NX5KA# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)   
    UCS Fabric Interconnect outputs:
    UCS-FI-A-A(nxos)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc1/31(D)    fc1/32(D)   
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int fc1/31-32
    !Command: show running-config interface fc1/31-32
    !Time: Fri Dec 20 22:58:51 2013
    version 5.2(3)N2(2.21b)
    interface fc1/31
      switchport mode NP
      channel-group 133 force
      no shutdown
    interface fc1/32
      switchport mode NP
      channel-group 133 force
      no shutdown
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int san-port-channel 133
    !Command: show running-config interface san-port-channel 133
    !Time: Fri Dec 20 22:59:09 2013
    version 5.2(3)N2(2.21b)
    interface san-port-channel 133
      channel mode active
      switchport mode NP

    !Command: show running-config interface san-port-channel 133
    !Time: Sat May 16 04:59:07 2009
    version 5.1(3)N1(1)
    interface san-port-channel 133
      channel mode active
      switchport mode F
      switchport trunk mode off
    Changed it as you suggested...
    Followed the order of operations for "no shut"
    Nexus FC -> Nexus SAN-PC -> FI FC -> FI SAN-PC.
    Didn't work:
    NX5KA(config-if)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)
    NX5KA(config-if)#
    Here is the output as you requested:
    NX5KA(config-if)# show int san-port-channel 133
    san-port-channel 133 is down (No operational members)
        Hardware is Fibre Channel
        Port WWN is 24:85:00:2a:6a:5a:81:00
        Admin port mode is F, trunk mode is off
        snmp link state traps are enabled
        Port vsan is 133
        1 minute input rate 1256 bits/sec, 157 bytes/sec, 0 frames/sec
        1 minute output rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
          3966 frames input, 615568 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          2956 frames output, 143624 bytes
            0 discards, 0 errors
          46 input OLS, 41 LRR, 73 NOS, 0 loop inits
          257 output OLS, 189 LRR, 219 NOS, 0 loop inits
        last clearing of "show interface" counters never
        Member[1] : fc2/15
        Member[2] : fc2/16
    NX5KA(config-if)#
    NX5KA(config-if)# show int brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc2/13     1      auto   on      sfpAbsent        --     --           --
    fc2/14     1      auto   on      sfpAbsent        --     --           --
    fc2/15     133    F      off     init             swl    --           133
    fc2/16     133    F      off     init             swl    --           133

  • About n1000v with port channel

    there is a n1000v connected to multiple upstream switches in the customer's production environment.
    the following is from the Cisco Nexus 1000V Interface Configuration Guide, Release4.2(1)SV2(2.1).
    You use vPC-HM mode to create a port channel when the switch is connected to multiple upstream switches
    that are not clustered.
    my question is,
    can I use LACP with multiple upstream switches that are not clustered?
    can I use LACP with multiple upstream switches that are stacked?
    if I stack multiple upstream switches,does it mean clustered?
    thanks.

    Hi,
    See some of the guidelines:
    Guidelines and Limitations
    Port channeling has the following guidelines and restrictions:
    •All ports in the port channel must be in the same Cisco Nexus 1000V module; you cannot configure port channels across Cisco Nexus 1000V modules.
    •Port channels can be formed with multiple upstream links only when they satisfy the compatibility requirements and under the following conditions:
    –The uplinks from the host are going to the same upstream switch.
    –The uplinks from the host going to multiple upstream switches are configured with vPC-HM.
    •You can configure multiple port channels on a device.
    •After you configure a port channel, the configuration that you apply to the port channel interface affects the port channel member ports. The configuration that you apply to the member ports affects only the member port where you apply the configuration.
    •You must remove the port security information from a port before you can add that port to a port channel. Similarly, you cannot apply the port security configuration to a port that is a member of a channel group.
    •You can configure ports that belong to a port channel group as PVLAN ports.
    •Any configuration changes that you apply to the port channel is applied to every member interface of that port channel.
    •Channel member ports cannot be a source or destination SPAN port.
    That said LACP should work on switches that are not clustered and meet the conditions above.
    A stack is treated as one unit which means that would be like you have just one big chassis.
    Stacking does not the same as clustering it works different. so if you stack them that would be a stack not a cluster
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4/interface/configuration/guide/n1000v_if_5portchannel.html#wp1270746
    Hope this helps.

  • Cisco MDS port channel with USC FI

    Hello,
    Can anyone help me to configure/troubleshoot Cisco MDS 9148 with Cisco USC ? M stuck in port channel..i have configured but interfaces are not coming UP.It is showing init state.
    My Topology is like,
    Nexus 5000-->USC FI (single FI) -->Cisco MDS 9148
                                                     --> Two Chassis
    Any help would be highly appreciated...
    Thanx

    TMC-UCSFI-A-A(nxos)# sh interface brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/31     1      NP     off     errDisabled      swl    --           --
    fc1/32     1      NP     off     errDisabled      swl    --           --
    Ethernet      VLAN   Type Mode   Status  Reason                   Speed     Port
    Interface                                                                   Ch #
    Eth1/1        1      eth  fabric up      none                        10G(D) --
    Eth1/2        1      eth  fabric up      none                        10G(D) --
    Eth1/3        1      eth  fabric up      none                        10G(D) --
    Eth1/4        1      eth  fabric up      none                        10G(D) --
    Eth1/5        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/6        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/7        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/8        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/9        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/10       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/11       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/12       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/13       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/14       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/15       1      eth  trunk  up      none                        10G(D) 100
    Eth1/16       1      eth  trunk  up      none                        10G(D) 100
    Eth1/17       1      eth  fabric up      none                        10G(D) --
    Eth1/18       1      eth  fabric up      none                        10G(D) --
    Eth1/19       1      eth  fabric up      none                        10G(D) --
    Eth1/20       1      eth  fabric up      none                        10G(D) --
    Eth1/21       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/22       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/23       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/24       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/25       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/26       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/27       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/28       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/29       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/30       1      eth  access down    SFP not inserted            10G(D) --
    output ommitted
    TMC-UCSFI-A-A(nxos)#
    Here it shows that Fc1/31- 32 which are in trunk , status is errdisabled and admin trunk mode is off

  • Win2003 ServerIssues with Port Channel?

    Hello all. I have had 2 different Windows 2003 Servers with Teamed 1000MB NICs have trouble when connecting to a port channel on a 4507. The server is not pingable while connected to the port channel. Once I remove the 2 interfaces from the port channel, communication is back up. I do see that when looking at the mac-address table for one of the interfaces in the port channel it shows both the virtual MAC of the teamed NICs and the physical mac of the NIC. This seems to be an issue but does not happen with any of our Windows 2000 Servers. They only show the virtual MAC when looking at the table.
    Any information on this issue is appreciated. It may be more of a Windows problem than Cisco but I will check both.

    Hello,
    which NICs do you have (brand) ? Not sure if this helps, but what if you configure port security on both ports of the 4507, allowing only the virtual MAC address ?
    Regards,
    GP

Maybe you are looking for

  • Problem in changing the created pdf document

    Hi , My scenario is like this. 1.I have a form with some questions designed for sending it to associates of the company.Each question will have four options.Once the creation of form is done I am sending this to associates inbox(sap).he has to access

  • Various errors, incorrect version of track (from iCloud restore) from an iTunes album

    Sorry for being a bit vague describing the problems but they are too complicated to summarize in 1 sentence. I bought a number of albums from iTunes last December, including LeAnn Rimes "I Need You".  I have a car that allows me to play iTunes music

  • Read 0CALMONTH takes long time

    Hi all, I have a performance problem. When I read some data from a large ODS, it takes a very long time. I noticed that during the reading the system spend a lot of time on 0CALMONTH characteristic (select from sid table). I'd like to know why, and i

  • Availability of System id value in a BPM

    Is there anyway of knowing which system or the SAP system id, the BPM is running on (ex: DEV, TST, PRD) based on context object or any other container variable. If so, how can I access this information. Please let me know as soon as possible. Thank y

  • RAC and ASM with geographically seperated disks

    We are planning to use RAC and ASM with four nodes. The two nodes will be at one location and another two nodes at different location. The ASM disks also will be available locally. Is it possible to configure ASM with geographycally serepared disks.