Problm tih unit measure conversion

Hello Sdn,
I am facinga problem while changing the Purchase Info Record (ME12) via BDC. I am getting 2 errors and record is not getting updated.
1) Conversaion problem with unit & Measure
2) field KONP-NBETR value longer then screen field.
I was user conversaion function module for unit measure value, still iam getting this error. Could you please any body help me out from this issue, so that I can move a head. Appreciate for your immediate response.
Regards,
Kumar.

Its closed

Similar Messages

  • Report on material code, description and all unit of measure conversions

    report on  material code, description and all unit of measure conversions ?
    any ideas?

    Material Number MATNR
    with this key and SPRAS (the desired Language key)
    from MAKT you can get the descriptions..
    and with MATNR from MARM you can get alternative UOM and the conversion rates.
    If you need help on MARM how to get the conversions please notify.
    Hope it helped
    Please reward if found useful
    Best Regards

  • Unit of measure conversion for CIN is not relevant for pricing

    During creation of Ad item type order, when we enter the planned ad size e.g. A CO (Columns) x B IN (Inches), the system is showing a message "Unit of measure conversion for CIN is not relevant for pricing" and pricing is not determined in the Billing Data Set. However if the planned ad size is maintained as A CO (Columns) x B MM (Millimeters), there is no impact to pricing conditions.
    Any light how to fix this issue?
    Thanks,
    Suseela. V

    Dear Suseela,
    You need to maintain Unit of conversion using transaction code JH51. You have to follow the path Logistics-Advertising Management-Master Data-Conditions-Order/Billing Document-UM for Pricing.
    Here you can maintain combination using Booking Unit, Content Component, Design type and assign Unit of Measure to get relevant pricing into billing set conditions.
    Hope it will help. Thanks!
    Regards
    Indra

  • Error in units of measurement conversion  "BOM"

    hello gurus gudmorning everybody
    i have problem in  project regarding the units   of  measurement conversion BOM
    this is the scenario: 1000 ft2(  BASE UNIT MEASUREMENT)  = 1ea (    SALES UNIT) ( 2bed room flat) it is a higher level item
    sub items are in EA  base unit measurement ex: like  one sofa one air conditioner etc instead of taking sale unit measurement of higher level item , its taking base unit mesurement of higher level item , .i.e instead of taking 1EA  2bhk = 1AC, 1 SOFA,   but is calculating 1000ft2( 2bhk)   = 1000ac, 1000sofa , plz help out to rectify the conversion
    thank you in  advance
    venkat

    Dear Venkat,
    Try with this
    Please maintain the alternative unit of measure in sub itemes master data at Additional tab like this
    in AC master data 1EA = 1AC and 1AC = 1EA 2BHK
    in Sofa master data 1EA = 1 Sofa and 1Sofa = 1EA 2BHK
    Now you try
    I hope this will help you,
    Regards,
    Murali.

  • Unit of Measure Conversions.

    Hi All, I have Unit of Measure Conversion requirement in my reports, I would like to create a variable and user has an option to choose the Target UoM.
    For this I have referred RSUOM T-Code and got an option to create Target UoM Variable (Specifying Target UoM using a variable) but here my proble is, have to do conversion across dimensions as below.
    Unit of Measure conversions that I have across dimensions (all conversions both ways):
    tonne to kilotonne
    1000 GJoule to Million GJoule
    kilotonne to Million tonne
    tonne to Million tonne
    kilogram to tonne
    tonne to barrel
    kg to liter (spill)
    tonne to gallon
    Could anyone tell me, is it possible to do conversion Across dimensions? (i.e Mass to Volume), if itu2019s possible where we need to maintain the conversion values.
    I am not able to see any table which holds the values of Unit of Measure, I saw T006 but could not able tofind any info.
    Thanks in Advance.

    Hi Kalyan,
    To convert from kg to litres you need material specific information like relative density .
    It can not be done with common values in UOM-conversions.
    e.g. the relative density for lead (11.35 kg/ litre) is different from the relative density for water (1 kg/litre)
    1 tonne = 1000 kgs for every material.
    Udo

  • Decimal in Unit of Measure conversion

    Hi Gurus,
    I want to enter decimals in Unit of Measure conversion. System is giving the error that "Decimal not permitted". Actually the scenario is we have a material with KG as a base unit of measure. The ordering unit is "L" litre and the conversion factor is:
    1 Litre = 0.792 KG
    But when I am going to enter the conversion the system is not allowing to enter decimal. What I need to do in the configuration to enable the decimal entry.
    Earliest response will be highly appreciated.
    Thanks

    >
    Imran Khan wrote:
    > I have entered 1000 Litre = 792 Kg, but when I order 1Kg, system is converting it into 12.62 Litres.
    >
    > Thanks
    if 792 kg equal to 1000 ltr,
    then 1 kg equals to 1,263 ltr.
    when do you see this "conversion" to 12,62 litres? in ME21N after you entered 1 KG?
    if yes, then your order unit is probably set to liter, further check if you have a rounding profile in material master or info record, that causes the switch from 1,26 to 12,62

  • Routing - decimal places for unit of measure conversion quantity

    Hello all,
    in the change routing screen in SAP (CA02), when going to a operation detail screen, a unit of measure conversation value can be defined. A value for header and operation can be made.
    Currently we cannot set any decimal values for operations, I get the error message: "decimal places are not permitted."
    Where in customizing can I change that?
    Thanks
    Anne

    Hello,
    thanks for the answers.
    The UoM is LB.
    I've already checked CUNI, but I can not find LB..?
    Also I've noticed other places in SAP, for example the base quantity of some operations in the routing have a numbers with 3 decimal places and the same UoM LB, so this looks like the UoM is setup fine, maybe there are just problems with this special screen?
    Thanks
    Anne

  • Routing unit of measure conversion

    Dear guru ,
    I have a different unit of measure for one operation of my routing.
    Which is the problem if I maintain relation 1 to 1 in the routing unit of measure conversion ?
    Thanks.

    Dear  ,
    One operation of my routing have a different unit of measure (EA for operation , KG for routing).
    I don't know the exact conversion factor between operation and routing.
    This factor is only known after the confermation of the production order.
    Which problem occurs if i maintain relation 1 to 1 (numerator and denominator) in the routing unit of measure conversion.
    Thanks.

  • Conversion automatic unit measure

    Dear all.
    I have a question/trouble with the unit measure.
    I am using a material with Base Unit of Measure = pza and Order Unit = crt.
    When a SC is created; it is with a Base Unit of Measure = pza; but when PO is created, It does not make the automatic conversion of Order Unit = crt
    How can I make this conversion automatic?
    I appreciate your support in this issue
    Thanks in advance

    Any suggestion?

  • Component material costing (Unit of Measure conversion) is not working at S

    Hi,
    Unit of Measure conversion factor (Value) is not working for component materials at Sales order level costing, but the same conversion factor is working fine at Standard cost estimation level.
    Example:
    Conversion Factor for Raw materials (Procurement in Tones, Consumption in Each)
    1 Ton (Rs.1000) = 10 Each (per Each u2013 Rs.100)
    For Manufacturing of 1 pc FG is required 1 each Raw material
    Issue: At sales Order level - Raw material costing is calculated at u201CTonu201D price u2013 Rs.1000 instead of u201CEachu201D price u2013 Rs.100. 
    Regards
    Nagesh

    Hi,
    Pricing (unit conversion) is done different for MM and SD process.
    MM has decided to use the old process which determines the values out of T006. There you have the conversion factors which are used in PO. If you create a sales order or billing document the determination will be different as the material master will be read.
    regards
    Waman

  • Automatically pick material master unit of measure conversion to routing

    I maintain finish goods conversion factor in material master u201CAdditional Data: Unit of measureu201D as M to KG and basic unit of measure for finish good in material master is in KG.
    I attached multiple operations for the finish goods material in routing.
    Some operations base unit of measure is M and others its KG.
    I want to pick material master unit of measure conversion automatically when Iu2019m creating routing for the finish good material in ca01. (Unit of measure conversion for header and operation of the operation)
    Can anyone letme know the SAP configuration for this.

    Hi!,
    Please expalin about the purpose of this requirement, because when you will create a order using that routing, at that time system will definately do the unit conversion automatically.
    Regards,
    Uday

  • Unit of conversion in BW 3.5

    Hi BW Experts,
    I impletented Unit of measure conversion in BW3.5 as same as mentioned in the doc "HOW to........Report data in Alternate Units of measure". When I am executing query in BEX Analyzer it gives Alternate uom as in ERR.
    Please guide me .......
    Full points will be assigned.
    Thanks!
    Sapna

    Hi
    Please check whether your keyfigure is hard coded with any of the unit field...
    Teja

  • PO with New unit of conversion

    Hi,
    We have the situation is PO is not update the new unit of measure conversion. As the PO was created with reference to the contract. The contract donu2019t have the unit of conversion. I know the PO is picking from the contract. Iam not able to change the contract with new unit of conversion. Pl advice how the PO will pick the new unit of conversion.
    Regards,
    Kumar

    Hi
    Thanks for the info.. i did the same but it taking unit conversion from the contract not from material master
    Kumar

  • RSUOM Unit of Conversion in Bex 3x

    Hii,
    Can I use RSUOM (Unit of Conversion) in Bex 3x.
    Best Regards,
    Mehmet

    This transaction is available only as of BI 7.0

  • Unit of measure conversion during backflushing

    Dear All,
    The BUOM for one component in our industry is in KG whereas in Bom it is defined in G(grams) due to very low consumption qty & I have maintained conversion in material master additional data tab already but on backflushing the system is putting this item in COGI such as .350g(which becomes .00035KG in base unit because as per std only 3 decimal places are allowed in BOM ) so the error text qty in stock keeping unit is zero in COGI is generating & the system is not posting this qty in consumption pls. help to resolve this because i can not change my base unit from KG to G.
    Regards
    Rakesh Sehgal

    Hi Sehgal,
    As the KG and Grams belong to same Unit, you need not maintain the alternate unit of measure in Material Master, additional tab screen.
    Only thing which is required to maintain is In Basic View maintain the BUOM as "KG" anh in Work scheduling view maintain the Issue Unit as "G". and Also in BOM you maintain the UOM as "G".
    Your issue will be resolved.
    Do the above and check and let us know
    Regards
    radhak mk

Maybe you are looking for

  • Books for web developement with oracle 10.1.2 Jdeveloper

    I a new to web developement with ADF BC. Steve's toystore is of great help.However to built of my basics and sharpen my knowledge,I want to buy a few books.Can anyone recommend any good books with project oriented approach for webdevelopment. For now

  • Adding field to crmd_order

    Hello All, I want to add a Field in  table control in Crmd_order general tab. Please Let me know it is Possible to add, if Possible Let me know how to achieve this Functionality. Thanks, Feroz.

  • Analytic Privilege : Something went wrong

    Hi folks, I am trying Analytic Privilege on SP08 system(doesn't matter what the system level is, but still ). I created two tables in the schema "SREEHARIV" associated to the user "SREEHARIV". Tables are Products and Desc. Then I created one attribut

  • Should I get a warning!

    Hi, I am working through a document on generics, j-generics-a4.pdf that I downloaded from the IBM site. It says that the following code should produce a warning when compiled. import java.util.*; public class Generics6   static void print(List l)    

  • Can't see my mac in Find My Mac, even with it enabled.

    I have a C2D Macbook Pro, Late 2006 Model. I have successfully upgraded to the newest version of leopard, and have enabled all the settings of iCloud with no error messages. Problem is, when i go to look at my iCloud account in a browser and look for