Removing Message Interface From Business Service

Hi Experts,
I want to remove one message interface from the Business Service.But, am not able to do so from ID.
Can anyone tell me how can this be done?
Thanks,
Sushama

hi,
>>>Business Service.But, am not able to do so from ID.
if you're talking about business service (not business system)
then just select the message interface and press the minus sign
that's all
if this is not possible you may not have sufficient authorization
Regards,
Michal Krawczyk

Similar Messages

  • Error Message: Data from Business Add-In ME_PROCESS_PO_CUST not transferred

    Hi All,
    I have done a BADI implementation for ME_PROCESS_PO_CUST and when I try to convert a PR to PO using ME59N in ECC u2013 AFS System I am getting below error message.
    Data from Business Add-In ME_PROCESS_PO_CUST not transferred.
    I am trying to populate certain PO fields ( ekko and ekpo ) from PR fields. But the above error occurs when I update the Ex Factory Date manual that is EKPO-J_3AEXFCM.
    I am updating this in the method PROCESS_ITEM and what I found while debugging is in the class CL_PO_HEADER_HANDLE_MM, in the implementation of IF_FLUSH_TRANSPORT_MM~START, the contents of field u2018my_iteration_countu2019 keeps increasing and becomes 10 and raises this error.
    I read few of the related questions raised by others in this forum and understood that this can happen if I try to change the field that is disabled ( greyed) in ME22N. But this field that I am talking about is enabled.
    I also tried to move my code of populating the field EKPO-J_3AEXFCM from the PROCESS_ITEM to the enhancement point just above the user exit EXIT_SAPMMO6E_018 but still it doesnu2019t resolve the error.
    (We donu2019t want to use User Exit and hence we are trying with BADIs or enhancement point.)
    Can anyone please help me with this. I also found an OSS note 1334046 but not sure if that can resolve my issue.
    Thanks in advance.
    Ameesha.

    Hi Ameesha,
    i think u need to implement the BADI ME_PROCESS_PO_CUST in SPRO settings.
    SPRO>Purchasing>Business Add-in Purchasing-->BAdI: Enhance Processing of Enjoy Purchase Order
    try this once.
    All check this link.
    [Error Message: Data from Business Add-In ME_PROCESS_PO_CUST not transferred;
    Hope it helps.
    Regards,
    Raj

  • Creaing Message interface from another software component imported object

    Hi all,
      Will it be possible to creaing Message interface from another software component imported object like i need to create idoc Abstract interface in one software component by using the imported object from other software component
    regards,
    Dhil

    Hi,
    In thise case your SC2 Software Component is dependent on SC1.
    Go  to the SLD, go to the software component SC2 and you will have an option Dependency and as shown in michal's blog make this SC2 dependent on SC1.
    Next, reimport your Software Components SC1 and SC2 in your IR . The old objects will contnue to exists but still clear the SLD cache, and reimport the SC1 and SC2 from the SLD.
    Now in SC2 you will see a new option called BASIS objects under which you can see the message interfaces of SC1.
    Regards
    Bhavesh

  • Call ODI interface from Business Rule

    Hi All,
    Is there any way to call ODI interface from business rule?
    I search the forum and found there is a way to call java code from business rule by CDF.
    ODI provide a dos batch file to invoke the ODI interface. But, how can I call batch file from business rule.
    I am using planning version 11.1.1

    Thanks.
    I can call the JAVA from business rule after assign the security in udf.policy.
    And, I am working on calling ODI scenario. However, I found connection refuse as follows.
    ava.net.ConnectException: Connection refused: connect
         at java.net.PlainSocketImpl.socketConnect(Native Method)
         at java.net.PlainSocketImpl.doConnect(PlainSocketImpl.java:333)
         at java.net.PlainSocketImpl.connectToAddress(PlainSocketImpl.java:195)
         at java.net.PlainSocketImpl.connect(PlainSocketImpl.java:182)
         at java.net.SocksSocketImpl.connect(SocksSocketImpl.java:366)
         at java.net.Socket.connect(Socket.java:520)
         at java.net.Socket.connect(Socket.java:470)
         at java.net.Socket.<init>(Socket.java:367)
         at java.net.Socket.<init>(Socket.java:180)
         at oracle.odi.sdk.invocation.internal.AgentNetworkCmd.<init>(AgentNetworkCmd.java:38)
         at oracle.odi.sdk.invocation.OdiInvocation.<init>(OdiInvocation.java:107)
         at com.gammonconstruction.odi.ODICaller.main(ODICaller.java:
    do I need to add scheduler agent for java request ?
    and, how to add the agent if need?

  • ACCESS_VIOLATION at AdobeOwl.dll when call Indesign com interface from windows service

    ACCESS_VIOLATION at AdobeOwl.dll when call Indesign CS3 COM interface from windows service application.
    Does anyone know how to workaround this issue ?

    As AdobeOwl.dll file is missing or corrupted, you need to get a new dll file. Here are the steps to replace setup.dll file
    Step 1. You can download missing AdobeOwl.dll here:
    http://dllcentral.com/AdobeOwl.dll/1.0.92/download/
    Step 2. Paste this file into your system32 or SyWOW64 folder.
    Step 3. Navigate to your System32(32Bit OS) or SyWOW64(64Bit OS) Folder.
    Note: The location of System32 and SyWOW64 is
    C:Windows\System32 (If you are using 32Bit Windows)
    C:\Windows\SysWOW64 (if you are using 64Bit Windows)
    Step 4. Paste the AdobeOwl.dll file into this folder.
    Step 5. Try to run it. It might work now. If not, restart your computer to restore it effectively.

  • Cisco Prime 2.0 Infrastructure-how to remove unneccessary interfaces from monitoring

    Hello all,
    We have Cisco Prime 2.0 Infrastructure and I would like to know how to remove certain interfaces from monitoring?  For example, I do not need monitoring on some ISDN and FXS/FXO ports.  I am receiving email alerts for ISDN channels going up/down for example.   Thanks.

    take a look at:::
    http://www.cisco.com/en/US/docs/net_mgmt/prime/infrastructure/2.0/user/guide/setup_groups.html

  • Payload from Two diff Outbound interfaces and Business Service

    Hi All:
    I created a scenario....where messge is coming from two diff outbound message interface..and have only one inbound inteface...
    Message_One is coming from one OA interface.
    Message_Two is coming from other OA interface.
    I am using only one Inbound interface...
    Message Mapping
    Source Message:
    MessageOne
    MessageTwo
    Target Message:
    Message.
    Now for this I cretaed one IP
    <b>Fork</b> (two receive steps..for message one and mesage two)
    <b>Transformation</b> (Interface Mapping between (Message one, Message Two) and Message
    <b>Send.</b>
    Here is the source from the Test Tab of the IR tool.
    <?xml version="1.0" encoding="UTF-8"?>
    <ns0:Messages xmlns:ns0="http://sap.com/xi/XI/SplitAndMerge">
       <ns0:Message1>
          <ns1:MT_Message_One xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
             <CutomerName>Gillette</CutomerName>
             <CutomerID>AA123</CutomerID>
             <ProductName>PN</ProductName>
             <ProductID>1234</ProductID>
          </ns1:MT_Message_One>
       </ns0:Message1>
       <ns0:Message2>
          <ns1:MT_Message_Two xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
             <ProductCost/>
             <ProductManufaturingDate/>
             <ProductExpDate/>
             <ProductID/>
          </ns1:MT_Message_Two>
       </ns0:Message2>
    </ns0:Messages>
    Now below information is coming from first File
           <CutomerName>Gillette</CutomerName>
             <CutomerID>AA123</CutomerID>
             <ProductName>PN</ProductName>
             <ProductID>1234</ProductID>
    This infromation is coming from second file
             <ProductCost/>
             <ProductManufaturingDate/>
             <ProductExpDate/>
             <ProductID/>
    Question how my input message looks for both??
    I am using HTTP client to send the two diff message from two diff Business Service to same BPM.
    Is it like
    <b> <ns1:MT_Message_One xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
             <CutomerName>Gillette</CutomerName>
             <CutomerID>AA123</CutomerID>
             <ProductName>PN</ProductName>
             <ProductID>1234</ProductID>
          </ns1:MT_Message_One></b>
    <b>      <ns1:MT_Message_Two xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
             <ProductCost/>
             <ProductManufaturingDate/>
             <ProductExpDate/>
             <ProductID/>
          </ns1:MT_Message_Two>
       </ns0:Message2></b>
    Thanks & Regards,
    Farooq Farooqui

    Yes now I achived it...
    It like the same as I mentioned
    <ns1:MT_Message_One xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
    <CutomerName>Gillette</CutomerName>
    <CutomerID>AA123</CutomerID>
    <ProductName>PN</ProductName>
    <ProductID>1234</ProductID>
    </ns1:MT_Message_One>
    <ns1:MT_Message_Two xmlns:ns1="http://t-systems.com/XI/Demo/BPM">
    <ProductCost/>
    <ProductManufaturingDate/>
    <ProductExpDate/>
    <ProductID/>
    </ns1:MT_Message_Two>
    </ns0:Message2>

  • OSB - Content length http header missing from business service out message

    Hi all,
    I am having some diffuclty with a business service in OSB. I created the business service from the wsdl and created a regular proxy service that just routes to the business service. When i run the test console i get the below fault.
    <faultcode>soapenv:Server</faultcode>
    <faultstring>BEA-380000: Length Required</faultstring>
    <detail>
    After some debugging i find that the content length http header is missing from the outbound message the business process creates and sends to the acutal web service which sends back the http 411 fault.
    Does anyone know how to configure the message flow of my proxy service to ensure that the outbound message sent from the business service contains that content length http header or any suggestions on how to fix this issue will be appreciated.
    Thanks

    Disable the "Use Chunked Streaming Mode" property in HTTP Transport Configuration of your business service. By default it remains enabled.
    Regards,
    Anuj

  • I am not viewing message interface for sender service in sender agreement

    Hi Experts,
    Right now we have one interface setup in XI for sending the data to three customers using BPMs.
    Now i want to add to one more customer in to current xi setup and send the data.
    so i have created all the types like message type, message interface and interface mapping.
    Already i have scenario in ID i have created Comm channles.
    so when i create sender agreement i am unable to find message Interface which i have created in IR for sender business service.
    I have not created new scenario but using the same scenario.
    Kindly help me out from this.
    Appreciate for your response.
    Thanks,
    Bhasker

    Hi,
    Make sure to add the inbound and outbound message interfaces in the Business Service so that they will be available in Sender Agreement.
    Hope this helps.
    Thanks and Regards,
    Kalpesh

  • How to transfer Message Interface from Repository to Directory

    Hello,
    I have created a Message Interface (with related Message Type, Data Type) and Interface Mapping from this interface to another in Integration Repository. Then I go to Integration Directory and trying to create Interface Determination. I can select proper Interface Mapping, but it doesn't show my Inbound Interface that I created for this Mapping (means in the popup hat I trigger in the Inbound Interface it shows no entries).
    It seems like some data has not been transferred from Repository to Directory. What should I do to synchronize them?
    Thanks,
    Maxim.

    Hi Maxim,
    If you dont activate the inteface you will not see. Even if you activated if you dont see in ID then you need a cache refresh. You dont need to do cache refresh everytime, because it will be automatically do. Just in case if you dont see then you can refresh manually. Also only for business service you need to add manually. For business system you will pick it up from the list.
    Regards,
    ---Satish

  • Adding Message Interfaces to Business System

    Hi All,
    Can anyone tell me how and why we dont add message interfaces to a business system??..
    The business system corresponds to Tech system which has software component...right?...
    so how do we get interfaces from diff components into the same business system?

    Hi Ravindra,
        The logical relation ship between Business Systems Technical Systems, Product and software components is as follows.
    1) Each business system will be associated with a technical System.
    2) Each SWCV will be a part of a Product.
    3) A Product is Installed on a Technical system.
    4) Multiple Products can be installed on a technical system.
    5) So, multiple SWCVs can be installed in a technical system.
    6) hence a Business system can have Message interfaces belonging to different SWCVs.
    Regards,
    ravi

  • Mapping error code from Business service to Proxy

    I am trying to get hands on with 11g and following the book Getting started with Oralce 11G soa suite. The example I have described is based on chapter 11 and chapter 14. I have a proxy service and business service. The business service calls a "ValidateCC" composite which validates the credit card information passed and is proxied by the proxy service. The validation of CC is done by a stored procedure, which returns an error ora-20001 if the credit card info is not found in the database.
    Testing PROXY service from OSB console:
    Here is the REQUEST message sent to proxy service:
    <soapenv:Envelope xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/">
    <soap:Header xmlns:soap="http://schemas.xmlsoap.org/soap/envelope/">
    </soap:Header>
    <soapenv:Body>
    <cca:creditcardStatusRequest xmlns:cca="http://www.globalcompany.com/ns/CCAuthorizationService">
    <cca:CCNumber>2234-1234-1234-1234</cca:CCNumber>
    </cca:creditcardStatusRequest>
    </soapenv:Body>
    </soapenv:Envelope>
    Here is the response message received:
    <soapenv:Envelope xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/">
    <soapenv:Body>
    <soapenv:Fault>
    <faultcode>soapenv:Server</faultcode>
    <faultstring>BEA-380001: Internal Server Error</faultstring>
    <detail>
    <con:fault xmlns:con="http://www.bea.com/wli/sb/context">
    <con:errorCode>BEA-380001</con:errorCode>
    <con:reason>Internal Server Error</con:reason>
    <con:location>
    <con:node>RouteTo_validationForCC</con:node>
    <con:path>response-pipeline</con:path>
    </con:location>
    </con:fault>
    </detail>
    </soapenv:Fault>
    </soapenv:Body>
    </soapenv:Envelope>
    Testing Business service from OSB console
    Response received for the same message:
    <env:Envelope xmlns:env="http://schemas.xmlsoap.org/soap/envelope/">
    <env:Header/>
    <env:Body>
    <env:Fault>
    <faultcode>env:Server</faultcode>
    <faultstring>
    Exception occured when binding was invoked.
    Exception occured during invocation of JCA binding: "JCA Binding execute of Reference operation 'validateCC' failed due to: Stored procedure invocation error.
    Error while trying to prepare and execute the VALIDATECC API.
    An error occurred while preparing and executing the VALIDATECC API. Cause: java.sql.SQLException: ORA-20001: UNKNOWN CREDIT CARD
    ORA-06512: at "SOADEMO.VALIDATECC", line 12
    ORA-06512: at line 1
    The invoked JCA adapter raised a resource exception.
    Please examine the above error message carefully to determine a resolution.
    </faultstring>
    <faultactor/>
    <detail>
    <exception>
    ORA-20001: UNKNOWN CREDIT CARD
    ORA-06512: at "SOADEMO.VALIDATECC", line 12
    ORA-06512: at line 1
    </exception>
    </detail>
    </env:Fault>
    </env:Body>
    </env:Envelope>
    What i need:
    I would like to have the exception 20001 populated in faultcode of the response from proxy message. A down stream BPEL process checks the faultcode and processes the message as needed.
    My OSB message flow contains :
    ValidateCredit +> envelope
    PipelinePairNode1
    Request Pipeline
    Report and Validate
    Response Pipeline
    RouteTo_validationForCC
    Service Error Handler
    stage1 with Alert action.
    My question is how to map the actual error occured in the cally be business service handler to the Service error handler in stead of throwing a generic BEA error. Please let me know

    Thank You Swgt for your reply.
    This is what I did:
    When I'm in Edit mode, in the OSB Web Console, I go to my proxy service, click on the Edit Message Flow icon, in the Map of Message Flow window I left-click on my Route icon (which as you already mentioned routes to my Business Service), select Add Route Error Handler (this option only appears if you're in Edit Mode already), click on the Error Handler icon, Add Stage, click on the Stage icon, Edit Stage, click on Add an Action, Flow Control -> Reply. Here I select the Radio Button "With Failure" and then Save All and Activate the change for the session.
    Is this correct?
    I tried this. I no longer get the BEA-380001 error code. However, the fault returned is not a bindingFault as I would have expected, but rather a remoteFault. hence my fault policy never detects it, doesn't rethrow it, and my BPEL error handling never kicks in.
    Is there a way to change this to work more or less in the sense of the tutorial?
    Does using OSB to connect to the service automatically make it a remote fault, instead of a bindingFault?
    Here's the SOAP message handled by my BPEL Component.
    <messages>
    <input>
    <invokeCCStatusService_execute_InputVariable>
    <part name="part1">
    <creditcardStatusRequest>
    <CCNumber>2234-1234-1234-1234</CCNumber>
    </creditcardStatusRequest>
    </part>
    </invokeCCStatusService_execute_InputVariable>
    </input>
    <fault>
    <bpelFault>
    <faultType>0</faultType>
    <remoteFault>
    <part name="summary">
    <summary>Beim Aufrufen des Bindings ist eine Exception aufgetreten.
    Beim Aufrufen des JCA-Bindings ist eine Exception
    aufgetreten: "JCA Binding execute of Reference operation
    'validateCC' failed due to: Fehler beim Aufrufen von
    gespeicherter Prozedur. Beim Versuch, die VALIDATECC-API
    vorzubereiten und auszuführen, ist ein Fehler aufgetreten.
    Beim Vorbereiten und Ausführen der VALIDATECC-API ist ein
    Fehler aufgetreten. Ursache: java.sql.SQLException:
    ORA-20001: UNKNOWN CREDIT CARD ORA-06512: in
    "SOADEMO.VALIDATECC", Zeile 12 ORA-06512: in Zeile 1 Prüfen
    Sie, ob die API in der Datenbank definiert ist und die
    Parameter der API-Signatur entsprechen. Diese Exception wird
    als nicht wiederholbar betrachtet. Sie ist wahrscheinlich auf
    einen Modellierungsfehler zurückzuführen. Um den Fehler
    stattdessen als wiederholbar zu klassifizieren, fügen Sie die
    Eigenschaft nonRetriableErrorCodes mit dem Wert "-20001" zum
    Deployment-Deskriptor hinzu (d.h. weblogic-ra.xml). Um einen
    wiederholbaren Fault automatisch zu wiederholen, legen Sie
    folgende Eigenschaften von composite.xml für diesen Aufruf
    fest: jca.retry.interval, jca.retry.count und
    jca.retry.backoff. Alle Eigenschaften sind Ganzzahlen. ". Der
    aufgerufene JCA-Adapter hat eine Ressourcen-Exception
    ausgelöst. Prüfen Sie die obige Fehlermeldung sorgfältig, um
    eine Lösung zu finden.</summary>
    </part>
    <part name="detail">
    <detail>
    <exception>ORA-20001: UNKNOWN CREDIT CARD ORA-06512: in
    "SOADEMO.VALIDATECC", Zeile 12 ORA-06512: in Zeile 1</exception>
    </detail>
    </part>
    <part name="code">
    <code>{http://schemas.xmlsoap.org/soap/envelope/}Server</code>
    </part>
    </remoteFault>
    </bpelFault>
    </fault>
    <faultType>
    <message>0</message>
    </faultType>
    </messages>

  • Message Transferred to Business Service, but acknowledgement not possible

    I have an IDoc to Flat File scenario. Flat file communication channel is in a Receiver Agreement for a Business Service.
    The message posts fine, but in the acknowledgement there is the familiar problem:
    "Unable to convert the sender service BSE_XXXX to an ALE logical system"
    I have checked that the Business System has an associated Logical System, and that the Header of the Receiver Agreement has the Sender Service and Receiver Service fields populated. Still I get this problem.
    Any suggestions?
    BR,
    Tony.

    hi,
    u cant send acknowledgement through the file adapter.
    if u r using bpm then only u can do it
    plz rewards points
    vikas

  • Scsm 2012 - SQL reporting from business services

    when i process a report in SQL Reporting Services for Business Services - and many other configuration items - I put a column in the report for priority and when I output the report it appears as a number which is wrong.
    For example, I have in the pruiority field for business services a drop down of High, Medium and Low - when I output the report this value appears as a number rather than the work High, Madium or Low.
    Does anyone know why this is and how it can be fixed?
    tamrep

    It sounds like your Report showing the Priority ID rather than the Priority value.
    You need to add a JOIN Statement in your SQL query to join on the Priority ID from the ServiceDimvw to the Priority ID from the ServicePriorityvw.
    Something like this:
    SELECT DisplayName,
    Priority.ServicePriorityValue
    FROM ServiceDimvw
    LEFT OUTER JOIN ServicePriorityvw as Priority on ServiceDimvw.Priority_ServicePriorityId = Priority.ServicePriorityId
    Cheers
    Alex

  • Message Interface to Business System

    Hi
    Here is my SCenario
    Can anyone let me know how can I add a Inbound Interface to the existing Business System, on the receiver  Tab,
    I have message interface in ESR and needs to add to the business component, Do not see any option to add new message
    Your input is hilgly appreciated
    Thanks
    PR

    Hi...
    If I am not wrong, then you are developing your interface in PI7.1. Correct me if my assumption is wrong.
    You have to add your software components to the business system in the SLD, then only the MI will pop up in the inbound list.
    Till PI 7.0, you could select the "ALL" and any inbound to the BS, but the correct way is to add the S/w component to your business system and then use the message interface in your interface determination/receiver determination.
    Thanks,
    Pooja Pandey

Maybe you are looking for