WAAS Network Module IP address question

I've read the instructions for configuring a WAAS Network Module but I don't understand what IP space I'm suppose to use.
https://www.cisco.com/en/US/docs/app_ntwk_services/waas/waas/v403/module/configuration/guide/wsnmecfg.html
My 2821 has g0/1 as the LAN connection and s0/1 as the WAN link
g0/1.1 - 10.1.1.1 /24
g0/1.4 - 10.1.1.4 /24
s0/1 - 192.168.1.1 /30
Do I need to allocate a new subnet for interface service-engine1/0?  Or can is be an IP address in my 10.1.1.1/24 subnet?  What's the best practice? 
If it's a new subnet then I assume I need to add it to eigrp, right?
Here is the sample from the Configuration Guide...
interface service-engine1/0
ip address 10.0.0.20 255.255.255.0  <--- does this have to be it's own subnet, what's best practice?
service-module integrated-service-engine ip address 10.0.0.30 255.255.255.0 <-- this has to be in the same subnet as above, right?
service-module integrated-service-engine ip default-gateway 10.0.0.20 <-- is this always the "int service-engine1/0" IP?
Sorry for the shotgun question approach.  Thank you in advance.

Hi Tod,
The most common scenario is to allocate a new subnet for the module.  Since the module will need IP connectivity to the Central Manager, you should advertise it via EIGRP (or whatever routing protocol you are using).
Here are the answers to your command specific questions:
ip address 10.0.0.20 255.255.255.0  <--- does this have to be  it's own subnet, what's best practice?
> See above.  The most common scenario is to allocate a new IP subnet.
service-module  integrated-service-engine ip address 10.0.0.30 255.255.255.0 <-- this  has to be in the same subnet as above, right?
> Yes.  This is the IP address that is assigned to the NME-WAE.
service-module  integrated-service-engine ip default-gateway 10.0.0.20 <-- is this  always the "int service-engine1/0" IP?
> Correct.
Regards,
Zach

Similar Messages

  • WAAS network module and 2821 router?

    What WAE network modules will work in a 2821 router? This 2821 has a dual-T1 Multipoint connection back to our data center and I know that the users will benefit greatly from WAAS, but I'd rather not have to upgrade the router to a 3800 just to install a WAE module

    NME-WAE-502 will give you full functionality with the enterprise licence. This is the NME that is the most widely used for WAAS.
    NME-WAE-302 is available, but only supports the transport license which give you TCP optimizations only (no application AO support).
    NME-WAE-522 is only supported in the 3800 series routers.
    Hope that helps,
    Dan

  • Content Engine Network Module for Caching File Server Objects

    We have a content engine network module for a 2821 router located at a branch office that we'd like to use for clients to obtain locally cached file objects from a Windos server located at our headquarters or corporate office. I've been looking for some sample configs or documentation that will show me that this is possible and on how to do it since this is my first time ever doing. All I was able to find so far was the link below under "Support of Preloading of NTLM Authenticated Objects", but it seems incomplete in providing configuration tasks that most CCO doc's usually provide. Has anyone else had any luck finding some useful doc's or sample configs to get this accomplish? Thanks in advance.
    http://www.cisco.com/univercd/cc/td/doc/product/webscale/uce/acns55/55ldg/urlfiltr.htm#wp1158213

    You can't cache Windows Files using the Cache Engines.
    You CAN do this using WAFS though. I'd suggest looking at the WAFS (or upcoming WAAS) products, which use WCCP like the Cache Engines to transparently redirect Windows File Sharing requests.

  • How to find password of the network module when targetting vi to FP 2000?

    or how to target refined vi to the same ip addressed FP 2000.?. Please provide me is there is anyway i could find the password or targetting another vi on the same network module ...

    Hi,
    Can you explain in more detail what you are trying to do ? I would need to better understand your final goal to suggest something.
    Regards
    Andre

  • Cisco 4-Port ISDN-BRI Network Module

    Cisco 4-Port ISDN-BRI Network Module
    what does the BRI mean?
    I have this module in a 2600 series router. Can it be used for basic LAN connection (like a hub)?

    First, to answer your question: No, you cannot.
    ISDN is a Telco technology and protocol suite.
    "BRI" stands for "Basic Rate Interface," also described as "2B+D" for two Bearer channels and a "D" channel, which is used for control signaling in some configurations, and additional bandwidth in others.
    Max throughput is either 128K (2 X 56K or 64Kbps per channel) or 144Kbps (2B+16K that may be available in the D channel depending on your config.
    ISDN requires an intermediate telco-style switch between the clients and can't be used back-to-back directly.
    Good Luck
    Scott

  • Using Fieldpoint Explorer, I am having trouble configuring outputs on my RLY-420 and PWM-520 modules attached to an FP-1000 network module

    I have noticed that I can not get my Relay module to turn off all of the channels, also I can only set the PWM modules down to ~4% output.
    I have tried to "Reset" the factory defaults on the FP-1000. I've tried to configure the powerup states of the different modules, all with no luck.
    I have made sure I am running with the latest firmware on the FP-1000
    I did notice this problem before upgrading the firmware. Immediately after doing the upgrade the problem went away for a short while. Now it is back again.
    My system is configured as follows:
    1 FP-1000 network module @address 0
    4 FP-TC-120 modules @1,
    2, 3, 4
    2 FP-TB-10 dual channel bases @ 5, 6
    2 FP-PWM-520 modules @ 7, 8
    1 FP-RLY-420 module @ 9
    Something seems to me to be happening with my .iak file in FieldPoint Explorer, of course I could be completely off base.
    I appreciate any insight anybody might have with this problem
    Kerry Libberton
    TDA Research
    Wheat Ridge, CO

    Kerry,
    There are several different things that may be going on here. First of all, there may be an issue with power consumption. A network module (FP-1000 in this case) is designed to source up to 9 Watts of power to I/O modules. This assumes an average of 1 Watt per module. Certain modules require more than 1 Watt, most require less leaving extra power for the ones that require more. In your configuration, you may be over this depending upon how your FP-TB-10's are populated. Assuming that the TB-10 is unpopulated, your consumption is 4 * 0.35 + 2 * .25 + 2 * 0.6 + 1.7. = 3.8 Watts. Thus, the load from the Dual Channel modules may not exceed 5.2 Watts. If you are using exclusively the Dual Channel Analog Out Current modules, you will overload the power supply.
    Anothe
    r thing to look at is when resetting the network module, check the box that says factory configuration. After the reset, uncheck the box and then configure your channels and power-up values (edit this device on each module).
    Also, there are some times when relays may get "stuck" in an on position due to extremely high inductive loading. I have not seen that happen very frequently, but it does make me wonder, what type of load are you driving on the relay channels?
    The PWM module, has 12 bit resolution, and will accept values of 0% for the output duty cycle. What value for the period have you set?

  • REQ SAP FI MODULE- CERTIFICATION EXAM QUESTIONS AND ANSWERS

    REQ SAP FI MODULE- CERTIFICATION EXAM QUESTIONS AND ANSWERS
    Moderator: We should be thankful that you don't require to solve the exam for you

    Please type "certification" in the search field, you can find many threads regardding this.

  • "Bad quality received from network module."

    My computer has 2 Fieldpoint ethernet banks setup to allow Lookout to interface with mulitple HW peripherals.  Lookout launches automatically when the computer starts up.  And after everything is loaded, one of the ethernet banks will almost immediately log the following alarm, "Bad quality received from network module."  Does anyone know what criteria/logic is behind the triggering of this alarm?
    We have been unable to find any issues that would cause this alarm to go off.

    it is power cycled it works again. We have another FP1600 on same network with no problem. Ethernet drop is 230 feet. Part# is 185690E-01, firmware 4.11. I have swapped it with a spare unit we have of the same part number, 185690E-01 and firmware release.Mike,
    Thank you for using the discussion forums. If possible, please generate a phone support request at ni.com/ask. One of our engineers will be happy to help you resolve this particular issue.
    Regards,
    Michael Shasteen
    Applications Engineering
    National Instruments
    www.ni.com/ask
    1-866-ASK-MY-NI

  • IPS network Module, need help!!!

    Folks,
    I recently installed IPS network module in my 3662 router. I am having problems making the IPS log anything.
    When i access the web interface of the IPS, i see only 1 interface available under virtual sensor, the interface is fast 0/1. and the media type it shows is Backplain.
    I am confused, i thought that fast 0/1 on the IPS network module was the management interface??? on the IPS?
    Why don't i see another interface that is connected to the backplain of the switch???
    Many thanks

    There are 2 interfaces on the NM-CIDS.
    In version 5.0 they are called:
    FastEthernet0/0 and FastEthernet0/1
    FastEthernet0/0 is the external copper interface that you can plug a cable in to. It is the command and control port for managing the NM-CIDS. It can not be used for monitoring (can not be applied to the virtual sensor)
    FastEthernet0/1 is the backplane interface. It receives packets from the router for monitoring. This is the interface that should be applied to the virtual sensor.

  • NetWorker Module for SAP/Oracle

    Legato has NetWorker Module for SAP R/3 on Oracle and
    NetWorker Module for Oracle. Which one is better for a
    large SAP database over 1TB?

    Hi,
    we are using
    Module Name:  Legato NetWorker Module for SAP R/3 with Oracle @(#) Module Vers: 3.0.1
    for SAP R/3 Enterprise 4.7x110 with 6.40-Kernel.
    Regards
    Jürgen

  • Isolation network module

    I have a FP-1000 network module with a FP-AI-100, FP-DI-300 and FP-DO-403. I am using RS-232 serial communication. I have fried both of my computer's serial ports. Nothing happen to the network module or I/O modules. Can any one tell me what happen? How do I prevent this? I think I need an isolation serial board. Can anybody confirm that?
    Yan

    Hello Yan,
    I am not sure how your computer's serial ports got fried, I've actually never run into this before. The only thing I can think of is either a defective (or out of spec) power supply for the computer or a defective (or out of spec) power supply for the fieldpoint controller. If you had a serial isolation board, it's possible that it would help, but I'm somewhat doubtful. The isolation boards provide isolation from port to port. So you could still fry those ports depending on what is currently frying your ports. Perhaps you could give us some more information about your system set up, the conditions surrounding the frying of the computer's com ports, and any other information or troubleshooting you have done that may be relevant.
    Thanks,
    E.Lee
    Eric
    DE For Life!

  • Can C3KX-NM-1G network module run at 100mb?

    When trying to configure the speed setting on the interface I only have the "nonegotiate" option. The access switch on the other end can only run at 10/100mb. It's a vendor switch that I can't replace and must be connected via fiber due to distance. Is there a way for this network module to run at 100mb?
    Thanks 

    Can you please post the following output:
    1.  sh version;
    2.  sh log;
    3.  sh inventory

  • Setting network interface IP address

    Hello everyone,
    Is it possible to change a network interface IP address(eg set my local area connection IP) purely in Java or should JNI be used?
    Thanks in advance.

    I doubt there is a single, cross-platform way in purely Java, but short of using JNI you could probably use something like Runtime.exec() (assuming your user has proper permissions) and a corresponding command-line utility (like ifconfig on Unix/Linux, ipconfig on Windows).
    Edit From a brief look, it looks like ipconfig won't do the equivalent on Windows as ifconfig will do.
    Edited by: endasil on 16-Sep-2009 3:37 PM
    Edit Looks like the netsh command on Windows does some of those things:
    netsh interface ip set address local static 123.123.123.123 255.255.255.0 Source: [Wikipedia: netsh|http://en.wikipedia.org/wiki/Netsh]
    Edited by: endasil on 16-Sep-2009 3:39 PM

  • IDS Network module

    Does anyone can tell me if Cisco IDS Network module (NM-CIDS) can capture the vlan traffic, or it only can capture traffic going through it. If it can, how can I do that?

    Hi Biao,
    The NMCIDS module gets the traffic on its sniffing interface from the Router in which it is housed. The sniffing interface is not connected to switch to use the span configuration.
    You will need to enable the desired interfaces (including subinterfaces) on the router for packet monitoring. You can select any number of interfaces or subinterfaces to be monitored. The packets sent and received on these interfaces are forwarded to the NM-CIDS for inspection. The enabling and disabling of the interfaces is configured through the router CLI (Cisco IOS). So There is no way you capture the vlan traffic of the switch.

  • WAAS network design

    Hi all,
    In enterprise network there are these WAAS devices: several SRE-SM-700-K9 modules (each installed in separate branch border routers) and WAE-674 appliance located at head office. At the head office border router there is no WAE module installed (there is only WAE-674 appliance at head office). Branch sites are connected to Head Office via IPsec tunnels. How all of these devices must come together to optimize traffic flows from branch offices to central servers? Which device mode to select on WAE-674 appliance - application-accelerator or central manager? If application-accelerator mode is selected, where to place WAE-674 appliance assuming that Head Office border router has one inside and one outside interface?

    Hi Stan,
    I guess it comes from the fact that if we save the configuration of a device, it is to restore it at a later time.
    If we saved the IP address of the interface in the output, it would create problems once you would try to restore it as you can see:
    NME-WAE-2(config)#interface GigabitEthernet 1/0 NME-WAE-2(config-if)#ip address 2.2.2.2 255.255.255.0 Specified interface is configured from router.NME-WAE-2(config)#
    I agree it is debatable on whether or not this info should be included in the running config and you can see it as a bug, I see it as an implementation choice
    Regards,
    Nicolas

Maybe you are looking for