Measurement and Automation Explorer (MAX) configuration export and import fails, files missing

<I don't see a board for MAX so I posted it here.  I hope you don't mind.>
I am trying to migrate to a new computer and have successfully moved the LV code but it relies on the configuration setup in MAX to operate.  There are many configuration items includes hardware configurations, scales, etc. I have LV 6.1 on Windows XP and MAX v 3.1.1 on both machines.  When I export all data from computer 1, I end up with an NCE file.  This file is binary.  I've tried exporting to text format but have not succeeded.
When I try to import on computer 2, first MAX reports "Can not find RTE directory: C:\WINDOWS\system32\cvirte".  This seems weird since I didn't install LW/CVI when I installed LV.  I click OK.  I then get "Unable to open c:\program files\national instruments\max\bin\cvirte.rsc".  I click OK.  I then attempt to import the data from the NCE file but get "This wizard does not recognize the specified configuration file."
I tried installing NI System Configurator v5.5.1f0 but get the same results.
How can I safely migrate the MAX configuration data?

Yes, MAX is also installed with the motion controller driver.
NI-DAQ 6.9.2 is over 10 years old. I simply don't remember what issues it had, sorry. Version 7.4.4 was the latest for XP. Perhaps that works better.
And the cvirte was required for some of the MAX features. It should have been installed automatically.

Similar Messages

  • Measuremen​t and Automation Explorer (MAX)

    where does Measurement and Automation Explorer (MAX) store virtual channel names

    They are in the ivi.ini file, typically located in the \VXIpnp\WinNT\niivi directory. Substitute your OS name for "WinNT".

  • How do I increase the field of view in Measurement and Automation Explorer (MAX) Version 3.1.1.3003

    I am using Measurement and Automation Explorer Version 3.1.1.3003 to view pictures on a pc that are being sent from a video camera looking through a microscope.  The image I see in the viewfinder of the microscope is MUCH smaller than the image that is displayed on the pc screen.  Looking through the viewfinder of the microscope, I can see ~20 mm across the object, but the display from the camera in NI-MAX shows ~4.5 mm across the object.  How can I change how much of an object is displayed on the screen in NI-MAX?
    The camera is attached to the microscope with a camera adapter on the top of the microscope.  The lenses the camera "looks" through and the lenses used when one looks through the viewfinder are the same, so theoretically, there should be no difference in what is displayed on the pc and what is seen through the viewfinder.  We have ruled out the microscope and camera as the cause of the problem, which narrows it down to the NI-MAX software itself.
    I saw in the forums that you can zoom out on an image; however, this does not change the distance across an image that is seen, just makes the picture of the same ~4.5 mm across the object smaller in size.
    Any ideas or suggestions?

    I have attached a picture of the object's image being displayed on the pc monitor.  Where the field of view (FOV) in the microscope is almost 30 mm, the FOV displayed onscreen is about 7 mm.  After contacting companies various times I discovered there was a reducing lens that goes in the C-mount adaptor, but it is over $300. 
    I thought maybe that the FOV could be changed in in NI Measurement and Automation Exploer (NI-MAX).  Any ideas? 
    Attachments:
    field of view.png ‏2437 KB

  • Problems with Measurement and Automation Explorer (MAX)

    Hello LabVIEWers,
    I have been having a serious problem getting MAX to start and to remain stable. Here are the specifics:I am running LabVIEW 8.5 Full Development System on a Dell PC with 1GB of RAM and plenty of hard drive space. The OS is XP Pro and I also have McAfee Enterprise Virus Scan software.  MAX will start-up and appear to run for a few minutes and then the software bombs out. I get a "Measurement and Automation Explorer has encountered a problem and has to close" pop-up message. To fix the problem, I have uninstalled all NI software using MSI Blast. I have wiped the registry clean of NI keys as per instructions in previous posts. I have deleted any remaining NI software on teh hard drive including C:\program files\national instruments and C:\Documents and Settings\All Users\Application Data\National Instruments. I have then restarted the machine and did a complete fresh install from CD's, DVD's, and the harddrive (CD's written to hardrive and DVD written to harddrive first). I installed first the LabVIEW and then I installed the Device Drivers. I restarted the machine between installs. I have even installed the updated NIDAQ 8.6. After which I set protections on the NI directories to read/write. Ok, basically I have done all these things numerous times and I still cannot get things to work correctly.
    I was able to get into MAX for a little while (it is somewhat stable immediately after a fresh reinstall). I defined 4 Simulated DAQmx devices and none of them acted like they were simulated. I received various errors saying that the device was not found or could not be started. So I basically could not run my software with the simulated devices. LabVIEW sometimes seems to work ok but just now, I got a "Error loading nidmm_32.dll, initialization routine failed" error. I also get the same error for nilvaiu.dll. Both of these DLLs are in the C:\Program Files\IVI\Bin and  c:\windows\system32 directories respectively and prior to the last time I started the software, all worked ok with LabVIEW.
    Is my computer failing? Are there any other options to getting this installed without probems?
    Please help.
    Michael Froehlich

    Duplicate Post
    Keep discussion here
    National Instruments
    WSN/Wireless DAQ Product Support Engineer

  • How can I get all the options of Field Point Explorer 3.0.2 in Measuremen​t and Automation Explorer 3.1?

    I am a student using LabVIEW and Compact Field Point to implement a
    senior design project in Electrical and Computer Engineering.  We
    have LabVIEW 7.1 and a cFP-2020 and additional modules.  We are
    trying to use the CTR-500 module to output a pulse train to drive a
    stepper motor.  We have found instructions online of how to do
    this, but they all use Field Point Explorer.  The instructions
    make use of options in Field Point Explorer that are not included in
    Measurement and Automation Explorer (the software included with the
    cFP).
    I have downloaded Field Point Explorer 3.0.2 and followed the
    directions.  Now, in LabVIEW, when I using the newly created .iak
    file, I get a dialogue asking to find the SubVI: 'FP Read (Float Array
    -IO).vi'.  Included with LabVIEW are subvis for FP Read, but not
    with the float array part.  So I figure I cannot use Field Point
    Explorer created .iaks with LabVIEW 7.1.  So how cannot I access
    the same options in Measurement and Automation that I was able to find
    in Field Point Explorer?
    Thanks

    Hi,
    FieldPoint Explorer is no longer used to configure FieldPoint systems. However, I do not think that the configuring your system in FieldPoint Explorer is causing the error.
    FieldPoint systems are now setup in Measurement and Automation Explorer (MAX).  Information on setting up FieldPoint systems in MAX can be found in the MAX help under: Installed Products>> FieldPoint. Also, I recommend upgrading to the latest FieldPoint driver and version of MAX.  The FieldPoint VI's will be slightly different when you upgrade, so there is a good chance that this will eliminate the error.
    Regards,
    Hal L.

  • Error -2147220733 occurred at DAQ Assistant (in Measurement and Automation Explorer)

    Ok!  Just before the weekend I figured out how to make channels in Measurement and Automation Explorer for inputs through a couple different NI input devices (USB-9211A & PCI-6229 DAQ).  Things were going well.  Loaded up the computer today, added a few more channels.  Worked fine.  Now all of a sudden, any channel I make has an error and if I try modifying existing channels and saving, I get same error:
    "This global channel currently has an error.  You can save the global channel, but it cannot be used until all errors have been fixed.  Press "Yes" to save anyway, or "No" to cancel and show the error."
    If I hit yes, the channel is non functional.  After hitting no, I get:
    "Error -2147220733 occurred at DAQ Assistant.  Possible Reason(s): "
    with no possible reasons listed.  I tried restarting the program.  I tried restarting the computer.  I verified connections.  Searched for the above stated error number on ni.com, google.ca, and in the MAX help files, and found absolutely nothing.  I have no clue what to do.  Any help would indeed be very much appreciated.

    Hi there,
    This is my first time on here and I've only been using this software for a couple of days so it's possible I'm making a trivial error but I thought I'd post here anyway as I can't find anything on the net about my problem.
    I also get an error while trying to save:
    Error -2147220733 occurred at DAQ Assistant
    Possible Reason(s):
    Requested Code: -2147220733
    But mine comes about in different circumstances to the one in the original post on this thread by Kahless. I was editting a VI logger task and within that I was trying to edit an NI-DAQmx Task. I was trying to change the clock settings, specifically I was attempting to change the Rate (Hz) from the 1k default to just 20, or 200. I got the error while trying to save so changed it back to 1k, but the error persisted even though I'd set it back to what it was.
    I thought at first it might be simply that I was trying to edit an NI-DAQmx task within VILogger, so I tried making the ammendment directly but the problem was still there. 
    Any ideas?
    Many thanks.

  • Error 70025 in Measurement and Automation Explorer

    After a clean reboot of the system I receive Error -70025 ("Return Buffer is not empty..") in the Measurement and Automation Explorer. When I click on "Clear RDB" which is supposed to solve the problem, it says "Error clearing the return data buffer". In the status tab, all LEDs are flashing (Error Code varying from 0xFFFF to 0x0182).
    First, I simply tried to remove the motion controller (it's a NI PCI-7334) from the MAX tab which did not work. Then, I tried to repair the installation of all NI tools but this didn't help either.
    I'm working with NI Motion 8.4 and MAX 5.4.0f0 on Windows XP.
    Do you have any idea how to solve this problem? Currently, I cannot run the motor at all.
    Thanks,
    Jürgen
    edit: I just realize that the controlller is listed as PXI-7334 in the Windows Device Manager but in fact it is a PCI-7334. Would this explain the problem?
    update: Forcing the installation of the PCI-334 driver does not make any difference.

    Hi Jürgen,
    you can find the description of occurence and solution for this error here.
    Please try it.
    When it dosen't solve your issue please contact me again.
    Kind Regards,
    Philipp K.
    Applications Engineer | NI-Germany

  • Measurement and Automation Explorer does not recognize two identical USB 3.0 cameras at once. How do I fix this?

    I am running a set up which uses 2 identical USB Point Grey cameras of the same model (FL3-U3-13S2M-CS). Both USB cameras are plugged into the computer (blue USB cables). 
    When I open up Measurement and Automation Explorer and look under "NI-IMAQdx Devices" in the configuration tree, LavVIEW only recognizes one of the two USB cameras. Measurement and Automation Explorer only lists one camera, in which it recognizes it as "Point Grey Camera". Why this is occurring? How can I get LabVIEW to recognize two separate cameras of the same model? 
    Attachments:
    PointGreyCamera.JPG ‏2847 KB
    DualUSB.JPG ‏2932 KB
    MeasurementAutomationExplorer.JPG ‏99 KB

    That's about the old NI-IMAQ for USB cameras. IMAQdx has built in support for DirectShow connected cameras. IMAQdx should be able to use more than one DirectShow camera at the same time, but the Point Grey DirectShow driver may have some issues.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Parallel port not detected in measurement and automation explorer

    I have installed labview 2010 in windows XP.
    The problem what I am facing is I could not find "Serial & Parallel port" option in Measurement and automation explorer.
    After seeing the similar problem in forum I have installed Ni-Daqmx 9.0.2.  But still I can not see the ports in MAX.
    I think i have attached enough document .
    If the parallel port is not detected in MAX can we send digital data to parallel port.
    I have tested parallel port with LED connecting one leg in 1st data line(pin 2) and another in gnd(pin 25).
    And my program is to blink the led for every one second but I cannot see the blinking.
    Can anyone help in this regards
    thank you
    Attachments:
    max.jpg ‏90 KB
    port setting tab1.jpg ‏30 KB
    device manager resource tab.jpg ‏34 KB

    Thank you for ur reply Smercurio
    I have changed the bios setting now 
    but still i cant see the printer port in MAX
    Regarding my vi, now i changed it please see that also 
    I have given values to element of arrays as (1,2&4) 
    Now also it is not blinking instead it is glowing all the time without blinking.
    What i have to do next.
    Attachments:
    device manger.JPG ‏43 KB
    device manger2.JPG ‏165 KB
    port test.vi ‏9 KB

  • I can't find my PCI card using Measurement and Automation Explorer

    I've installed the PCI card.. It's a PCI-DAS08. The PC I'm running is quite slow, took like an hour to install Labview. The Measurement and Automation Explorer can't seem to find the card even though it's shown in the Device Manager. I don't know how to solve this problem. Any help or tips appreciated. THANKS

    Is tha device made by NI?
    MAX only supports NI DAQ devices.
    You will need the drivers and support software from the equipment manufactuer.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Is it possible to change the resolution of indivdual channels in measurement and automation explorer using a VI

    Hi
    I'm acquiring data on 8 analog input channels using a PCI-6052 E card. The data on channels 5 thru 8 is going to be between +1V and -1V. So for greater resolution I'm manually changing the range of these channels to +1V to -1V in the measurement and automation explorer. Is there a way by which I can make these changes directly using a VI ?
    Thanks,
    Shiv

    Hi
    Yes you can, but only if you use the "AI Config" VI. AI config allows different gains for different channels. The "channels" and "input limits" inputs of the VI accepts arrays. The first element of the input limits array corresponds to the first element of the channel array. Check the "cont acq&chart (buffered).vi" in the LV examples. There you see what I mean!
    Regards,
    Luca

  • Measurement and Automation Explorer not installed correctly

    I have a trial version of LabView 8.5.  Upon trying to change the Instrument I/O Assistant, I get "Measurement and Automation Explorer not installed correctly.  Please install from driver CD."  Well, I don't have the CD since this was a trial download.
    Basically, what I am trying to do is this:  I want to pull 4 variables/tags from an Allen Bradley PLC and log them to an Excel spreadsheet.  I am using RSLinx to communicate with the PLC, and LabView to compile the info. 
    Any help would be appreciated.

    Any Ideas?  I have the program running right now, and I'm kinda in a bind.  I also tried RSView32 Works to log the info, but there isn't enough flexibility in logging.  I need to log flow rate test results from a large automated machine.  The mahcine does a number of operations, but we are most concerned with these four tags (since it conducts four tests at once).  The problem is, the cycle time varies with the lot of product.  Some products require more time as the process is more delicate.  So, I can't use a time-interval logging method.
    As for variable change, I can't do that either because it records the 4 test results in series; not all at the same time.  That, and if the test is aborted (no tube), the previous test result value stays in the tag until there is a successful test.
    I found a variable that changes once per cycle.  I'd like to log the four tags once per cycle.
    BUT I can't do anything until I get the I/O Wizard working. 

  • Measuremen​t and automation explorer

    Hello,
    In my application, I want modify the offset and the sensitivity in scales of Measurement and automation explorer. Is it possible to do it in a VI and how?
    Because in my application I have a menu in which there is a calibration part. In this, I would like to group all parameters of my sensors (name, sensitivity and offset) and write automatically the offset and the sensitivity located in Measurement and Automation explorer without quit my application.
    Thanks for your help,Franc.

    There might be a way to do this with DAQmx, but DAQmx is not supported in LabVIEW Real-Time 7.0.
    Using Traditional NI-DAQ, you can only read custom scale information with Get Scale Information.vi. This VI is located under Data Acquisition >> Calibration and Configuration >> DAQ Channel Utilities.

  • Id like to be able to initialize my 7344 Motion Controller card from within Labview and not through motion and automation explorer

    Every time I boot my PC , I have to reinitialize my 7344 through Motion and Automation Explorer  in order for it to work. Does anyone have any suggestions as to how to initialize it from within labview itself?
    thanks

    Hi,
    I am sending you a Vi for initializing the controller.The only thing you have to do is that you need to use sequence structure. In the first sequence you need to use the VI which is attached i.e 0 (default). Then the next sequence will be the program itself.
    So that as soon as you run your vi the first thing done will be initialising controller using LabVIEW. Then your program will run.
    Here the led in the front panel will glow green only the first time you are initializing.The next time it will be dim but no doubt your initializing will be taking place.Hope this vi solves your problem.
    Thxs
    Manish Karnik
    Application Engineer
    Cruiser Controls
    Mumbai, India. 
    Attachments:
    Initializing controller.vi ‏42 KB

  • Recognitio​n usb device by measurment and automation explorer

    HI
    I have bought  nrf24lu1-dongle from nordicsemiconductor. this is a
    transciever with usb interface. when i attach that to usb port it will be
    recognized by computer .and in my package there is a driver for that too.so
    i think it must be a USBTMC device. but i can't see this device in measurment
    & automation explorer. i have update MAX driver(install legacy driver support) after ataching my device to
    pc .but no changes occur! this will occur for any kind of usb device like my
    mp3 player(i expect when i attach mymp3 player to usb port it must be accessible in measurment & automation). is this problem related with the kind of usb port that i use? all
    my usb ports are flat type(host) . or maybe my NI-VISA (version 4.5 is not a complete
    package! and don't support USB).
    with best regards

    Hello farashi,
    As noted in this KnowledgeBase article, the hid.dll file is from Microsoft, and you can find more information here.
    I also found this really helpful nugget on programming USB devices that may prove to be helpful.Hope this helps.
    Regards,
    Peter Flores
    Applications Engineer

Maybe you are looking for

  • Error when calling to an screenflow in a process deployed in Websphere

    Hi all, Environment: Solaris SunOS 5.10 (Generic January 2005), Websphere 6.1.0.13, JVM: 1.5.0_07 Product: AquaLogic BPM 6.0.2 for WebSphere We are testing our environment with a very simple process with only one interactive activity that is associat

  • I would like to learn how to make an alias for my "Home" page in Adobe Muse.

    Currently, my homepage is titled "Home."  This works great in the vertical menu at the top of the main pages.  It does not, however, work well if someone wants to bookmark my site in which case their bookmark generates the generic "Home."  Can I crea

  • Problem reading Photos on 6230i

    I have a 6230i and have taken,read and saved photos in the past using Lexmark P6350 printer with MMC slot. This time printer says it cannot find any photos and the card should be formatted. How do I do this? Can it be done without losing the photos?

  • Closing pending sales order

    Hai gurus Please help me how  to close pending sales order with open quantity. So that it cant be never used and partially delivered documents attached to that sales order should nt also be affected With Regards

  • Baffling problems with letter key and erratic keybinds

    I'm not even certain how to explain my issue. I was in the middle of typing an explanation to a friend in IM when I discovered that any attempt to press 'v' key resulted in a copy/paste of the URL I had attempted to send to him before. I checked to s