Nexus 1000v lacp "mode active"
Dear all,
today I installed my Lab new with ESXI 4.1 and the newest NX release. Everything fine.
But for my systemuplink I would like to use 2 Ports. I tried to configure a channel with "mode active" on all sites. This was not working only "mode on" was working. The Channel is configured in the "system-uplink" Portgroup. I use a 2960-8 Switch on the other side
Any Ideas?
I found a later discussion but without any solution...
thanks in advance
regards,
Sebastian
Hi Vishnu,
here my config (currently like I told no LACP "mode on"):
SWITCH
interface GigabitEthernet0/2
switchport mode trunk
channel-group 1 mode on
interface GigabitEthernet0/4
switchport mode trunk
channel-group 1 mode on
interface Port-channel1
switchport mode trunk
2960-LAB-1#sh int trunk
Port Mode Encapsulation Status Native vlan
Po1 on 802.1q trunking 1
Port Vlans allowed on trunk
Po1 1-4094
Port Vlans allowed and active in management domain
Po1 1-3,6-7,17-18,20,40,243
Port Vlans in spanning tree forwarding state and not pruned
Po1 1-3,6-7,17-18,20,40,243
Nexus Portchannel, still in "mode active", but seem to work with Switch in "mode on"
Nexus-1# sh port-profile name system-uplink
port-profile system-uplink
description:
type: ethernet
status: enabled
capability l3control: no
pinning control-vlan: -
pinning packet-vlan: -
system vlans: 6,243
port-group: system-uplink
max ports: -
inherit:
config attributes:
switchport mode trunk
switchport trunk allowed vlan 1-40,243
channel-group auto mode active
no shutdown
evaluated config attributes:
switchport mode trunk
switchport trunk allowed vlan 1-40,243
channel-group auto mode active
no shutdown
assigned interfaces:
port-channel1
Ethernet3/1 (member of port-channel1)
Ethernet3/3 (member of port-channel1)
Nexus-1#
Similar Messages
-
Nexus 1010/1000v L3 Mode Through ASA
Hi,
A question regarding the subject line. When deoploying redundant Nexus 1010 hardware appliances (VSM's) on the "inside" and Nexus 1000v's on your ESX hosts in the "DMZ" in Layer 3 mode which is seperated by an ASA, what VLAN's are actually need? Both from the inside and DMZ perspective. Specifically, do you actually need Control and Data/Packet VLAN's configured when using L3 mode. When you configure the SVS domin for L3 Transport you explicitly negate both Control and Data/Packet VLAN's?
Also, when configuring the 1000v in L3 mode is it best practice to have the system vlan the same as your management vlan, and also use the same vlan for the Vmkernal NIC. When setting up the Vmkernal NIC on the ESX host the only option available was to use the management vlan.Hello Aaron,
The Nexus 1010s only communicate in L2 mode so you'll still need control, management & packet vlans between the two appliances. VSMs deployed in L3 mode collapse the control & packet vlans into the management network. Traffic between the VSM and ESX host will be tunneled over IP. Therefore you need to ensure IP connectivity between the VSM mgmt0 interface and the ESX host management vmk.
Yes, you will want to define the ESX vmk vlan as a system vlan on BOTH the vethernet & ethernet port-profiles.
Matthew -
[Nexus 1000v] VEM can't be add into VSM
hi all,
following my lab, i have some problems with Nexus 1000V when VEM can't be add into VSM.
+ on VSM has already installed on ESX 1 (standalone or ha) and you can see:
Cisco_N1KV# show module
Mod Ports Module-Type Model Status
1 0 Virtual Supervisor Module Nexus1000V active *
Mod Sw Hw
1 4.2(1)SV1(4a) 0.0
Mod MAC-Address(es) Serial-Num
1 00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8 NA
Mod Server-IP Server-UUID Server-Name
1 10.4.110.123 NA NA
+ on ESX2 that 's installed VEM
[root@esxhoadq ~]# vem status
VEM modules are loaded
Switch Name Num Ports Used Ports Configured Ports MTU Uplinks
vSwitch0 128 3 128 1500 vmnic0
VEM Agent (vemdpa) is running
[root@esxhoadq ~]#
any advices for this,
thanks so muchHi,
i'm having similar issue: the VEM insatlled on the ESXi is not showing up on the VSM.
please check from the following what can be wrong?
This is the VEM status:
~ # vem status -v
Package vssnet-esx5.5.0-00000-release
Version 4.2.1.1.4.1.0-2.0.1
Build 1
Date Wed Jul 27 04:42:14 PDT 2011
Number of PassThru NICs are 0
VEM modules are loaded
Switch Name Num Ports Used Ports Configured Ports MTU Uplinks
vSwitch0 128 4 128 1500 vmnic0
DVS Name Num Ports Used Ports Configured Ports MTU Uplinks
VSM11 256 40 256 1500 vmnic2,vmnic1
Number of PassThru NICs are 0
VEM Agent (vemdpa) is running
~ # vemcmd show port
LTL VSM Port Admin Link State PC-LTL SGID Vem Port
18 UP UP F/B* 0 vmnic1
19 DOWN UP BLK 0 vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show trunk
Trunk port 6 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 16 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 18 native_vlan 1 CBL 0
vlan(111) cbl 1, vlan(112) cbl 1,
~ # vemcmd show port
LTL VSM Port Admin Link State PC-LTL SGID Vem Port
18 UP UP F/B* 0 vmnic1
19 DOWN UP BLK 0 vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show port vlans
Native VLAN Allowed
LTL VSM Port Mode VLAN State Vlans
18 T 1 FWD 111-112
19 A 1 BLK 1
~ # vemcmd show port
LTL VSM Port Admin Link State PC-LTL SGID Vem Port
18 UP UP F/B* 0 vmnic1
19 DOWN UP BLK 0 vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show port vlans
Native VLAN Allowed
LTL VSM Port Mode VLAN State Vlans
18 T 1 FWD 111-112
19 A 1 BLK 1
~ # vemcmd show trunk
Trunk port 6 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 16 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 18 native_vlan 1 CBL 0
vlan(111) cbl 1, vlan(112) cbl 1,
~ # vemcmd show card
Card UUID type 2: ebd44e72-456b-11e0-0610-00000000108f
Card name: esx
Switch name: VSM11
Switch alias: DvsPortset-0
Switch uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
Card domain: 1
Card slot: 1
VEM Tunnel Mode: L2 Mode
VEM Control (AIPC) MAC: 00:02:3d:10:01:00
VEM Packet (Inband) MAC: 00:02:3d:20:01:00
VEM Control Agent (DPA) MAC: 00:02:3d:40:01:00
VEM SPAN MAC: 00:02:3d:30:01:00
Primary VSM MAC : 00:50:56:ac:00:42
Primary VSM PKT MAC : 00:50:56:ac:00:44
Primary VSM MGMT MAC : 00:50:56:ac:00:43
Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
Management IPv4 address: 10.1.240.30
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 111
Card packet VLAN: 112
Card Headless Mode : Yes
Processors: 8
Processor Cores: 4
Processor Sockets: 1
Kernel Memory: 16712336
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: False
PC LB Algo: source-mac
Datapath portset event in progress : no
~ #
On VSM
VSM11# sh svs conn
connection vcenter:
ip address: 10.1.240.38
remote port: 80
protocol: vmware-vim https
certificate: default
datacenter name: New Datacenter
admin:
max-ports: 8192
DVS uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
config status: Enabled
operational status: Connected
sync status: Complete
version: VMware vCenter Server 4.1.0 build-345043
VSM11# sh svs ?
connections Show connection information
domain Domain Configuration
neighbors Svs neighbors information
upgrade Svs upgrade information
VSM11# sh svs dom
SVS domain config:
Domain id: 1
Control vlan: 111
Packet vlan: 112
L2/L3 Control mode: L2
L3 control interface: NA
Status: Config push to VC successful.
VSM11# sh port
^
% Invalid command at '^' marker.
VSM11# sh run
!Command: show running-config
!Time: Sun Nov 20 11:35:52 2011
version 4.2(1)SV1(4a)
feature telnet
username admin password 5 $1$QhO77JvX$A8ykNUSxMRgqZ0DUUIn381 role network-admin
banner motd #Nexus 1000v Switch#
ssh key rsa 2048
ip domain-lookup
ip domain-lookup
hostname VSM11
snmp-server user admin network-admin auth md5 0x389a68db6dcbd7f7887542ea6f8effa1
priv 0x389a68db6dcbd7f7887542ea6f8effa1 localizedkey
vrf context management
ip route 0.0.0.0/0 10.1.240.254
vlan 1,111-112
port-channel load-balance ethernet source-mac
port-profile default max-ports 32
port-profile type ethernet Unused_Or_Quarantine_Uplink
vmware port-group
shutdown
description Port-group created for Nexus1000V internal usage. Do not use.
state enabled
port-profile type vethernet Unused_Or_Quarantine_Veth
vmware port-group
shutdown
description Port-group created for Nexus1000V internal usage. Do not use.
state enabled
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 111-112
no shutdown
system vlan 111-112
description "System profile"
state enabled
port-profile type vethernet servers11
vmware port-group
switchport mode access
switchport access vlan 11
no shutdown
description "Data Profile for VM Traffic"
port-profile type ethernet vm-uplink
vmware port-group
switchport mode access
switchport access vlan 11
no shutdown
description "Uplink profile for VM traffic"
state enabled
vdc VSM11 id 1
limit-resource vlan minimum 16 maximum 2049
limit-resource monitor-session minimum 0 maximum 2
limit-resource vrf minimum 16 maximum 8192
limit-resource port-channel minimum 0 maximum 768
limit-resource u4route-mem minimum 32 maximum 32
limit-resource u6route-mem minimum 16 maximum 16
limit-resource m4route-mem minimum 58 maximum 58
limit-resource m6route-mem minimum 8 maximum 8
interface mgmt0
ip address 10.1.240.124/24
interface control0
line console
boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-1
boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-1
boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-2
boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-2
svs-domain
domain id 1
control vlan 111
packet vlan 112
svs mode L2
svs connection vcenter
protocol vmware-vim
remote ip address 10.1.240.38 port 80
vmware dvs uuid "c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78" datacenter-n
ame New Datacenter
max-ports 8192
connect
vsn type vsg global
tcp state-checks
vnm-policy-agent
registration-ip 0.0.0.0
shared-secret **********
log-level
thank you
Michel -
Nexus 1000v 4.2.1 - Interface Ethernet3/5 has been quarantined due to Cmd Failure
Hello,
i get the error message "Interface Ethernet3/5 has been quarantined due to Cmd Failure" when i try to activate the System Uplink ports on the Nexus 1000v VSM. The symptom occurs under 4.2.1.SV1.4 (has been fresh setup, did before tests with 4.0.4). Unfortunately, the link to the 4.2.1 troubleshooting guide does not work (seems it hasn't been released yet).
Has anyone an idea what the root cause could be?
The VSM and VEM run on a GP DL3xxG7 with 2 x Dual Port 10Gbit CNA Adapters.
Nexus 1k config:
vlan 1
vlan 260
name Servers
vlan 340
name NfsA
vlan 357
name vMotion
vlan 920
name Packet_Control
port-profile type ethernet SYSTEM-UPLINK
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 1,260,301,303,305,307,357,544,920
spanning-tree port type edge trunk
switchport trunk native vlan 1
channel-group auto mode active
no shutdown
system vlan 1,357,920
state enabled
port-profile type ethernet STORAGE-UPLINK
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 340
channel-group auto mode active
no shutdown
system vlan 340
state enabled
When i do a no shut on the physical ports i get:
switch(config-if)# no shut
2011 Feb 24 11:43:55 switch %PORT-PROFILE-2-INTERFACE_QUARANTINED: Interface Ethernet3/7 has been quarantined due to Cmd Failure
2011 Feb 24 11:43:55 switch %PORT-PROFILE-2-INTERFACE_QUARANTINED: Interface Ethernet3/5 has been quarantined due to Cmd Failure
The other etherchannel (Port Profile STORAGE-UPLINK) does work pretty well...
The peer switches are two Nexus 5k with VPC.
config:
port-profile type port-channel VMWare-LAN
switchport mode trunk
switchport trunk allowed vlan 260, 301, 303, 305, 307, 357, 544, 920
spanning-tree port type edge trunk
switchport trunk native vlan 1
state enabled!
interface port-channel18
inherit port-profile VMWare-LAN
description CHA vshpvm001 LAN
vpc 18
speed 10000!
interface Ethernet1/18
description CHA vshpvm001 LAN
switchport mode trunk
switchport trunk allowed vlan 260,301,303,305,307,357,544,920
channel-group 18 mode active
switch# show port-profile sync-status
Ethernet3/5
port-profile: SYSTEM-UPLINK
interface status: quarantine
sync status: out of sync
cached commands:
errors:
cached command failed
recovery steps:
unshut interface
Ethernet3/7
port-profile: SYSTEM-UPLINK
interface status: quarantine
sync status: out of sync
cached commands:
errors:
cached command failed
recovery steps:
unshut interface
kind regards,
andySean,
thank you !
"show accounting log" helped me - i had the command spanning-tree port type edge trunk in the config which i somehow didn't realize that we hadn't this command in the 4.0.4 lab setup...so it was a copy/paste error (i copied the port-profile config from the N5k down to the N1k).
Fri Feb 25 07:20:32 2011:update:ppm.13880:admin:configure terminal ; interface Ethernet3/5 ; spanning-tree port type edge trunk (FAILURE)
Fri Feb 25 07:20:32 2011:update:ppm.13890:admin:configure terminal ; interface Ethernet3/5 ; shutdown (FAILURE)
As the N1k doesn't do STP at all (or does it? ) it's no wonder that the cli was complaining ...
Maybe this command should get more attention in the tshoot guide as it seems to be a very helpful one.
Cheers & Thanks,
Andy -
Nexus 1000v VEM module bouncing between hosts
I'm receiving these error messages on my N1KV and don't know how to fix it. I've tried removing, rebooting, reinstalling host B's VEM but that did not fix the issue. How do I debug this?
My setup,
Two physical hosts running esxi 5.1, vcenter appliance, n1kv with two system uplinks and two uplinks for iscsi for each host. Let me know if you need more output from logs or commands, thanks.
N1KV# 2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 17 18:18:08 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
2013 Jun 17 18:18:09 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 17 18:18:16 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
2013 Jun 17 18:18:17 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 17 18:18:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
2013 Jun 17 18:18:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 17 18:18:28 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
2013 Jun 17 18:18:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 17 18:18:44 N1KV %PLATFORM-2-MOD_DETECT: Module 2 detected (Serial number :unavailable) Module-Type Virtual Supervisor Module Model :unavailable
N1KV# sh module
Mod Ports Module-Type Model Status
1 0 Virtual Supervisor Module Nexus1000V ha-standby
2 0 Virtual Supervisor Module Nexus1000V active *
3 248 Virtual Ethernet Module NA ok
Mod Sw Hw
1 4.2(1)SV2(1.1a) 0.0
2 4.2(1)SV2(1.1a) 0.0
3 4.2(1)SV2(1.1a) VMware ESXi 5.1.0 Releasebuild-838463 (3.1)
Mod MAC-Address(es) Serial-Num
1 00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8 NA
2 00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8 NA
3 02-00-0c-00-03-00 to 02-00-0c-00-03-80 NA
Mod Server-IP Server-UUID Server-Name
1 192.168.54.2 NA NA
2 192.168.54.2 NA NA
3 192.168.51.100 03000200-0400-0500-0006-000700080009 NA
* this terminal session
~ # vemcmd show card
Card UUID type 2: 03000200-0400-0500-0006-000700080009
Card name:
Switch name: N1KV
Switch alias: DvsPortset-1
Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
Card domain: 2
Card slot: 3
VEM Tunnel Mode: L3 Mode
L3 Ctrl Index: 49
L3 Ctrl VLAN: 51
VEM Control (AIPC) MAC: 00:02:3d:10:02:02
VEM Packet (Inband) MAC: 00:02:3d:20:02:02
VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
VEM SPAN MAC: 00:02:3d:30:02:02
Primary VSM MAC : 00:50:56:b6:0c:b2
Primary VSM PKT MAC : 00:50:56:b6:35:3f
Primary VSM MGMT MAC : 00:50:56:b6:d5:12
Standby VSM CTRL MAC : 00:50:56:b6:96:f2
Management IPv4 address: 192.168.51.100
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Primary L3 Control IPv4 address: 192.168.54.2
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 1
Card packet VLAN: 1
Control type multicast: No
Card Headless Mode : No
Processors: 4
Processor Cores: 4
Processor Sockets: 1
Kernel Memory: 16669760
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: True
PC LB Algo: source-mac
Datapath portset event in progress : no
Licensed: Yes
~ # vemcmd show card
Card UUID type 2: 03000200-0400-0500-0006-000700080009
Card name:
Switch name: N1KV
Switch alias: DvsPortset-0
Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
Card domain: 2
Card slot: 3
VEM Tunnel Mode: L3 Mode
L3 Ctrl Index: 49
L3 Ctrl VLAN: 52
VEM Control (AIPC) MAC: 00:02:3d:10:02:02
VEM Packet (Inband) MAC: 00:02:3d:20:02:02
VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
VEM SPAN MAC: 00:02:3d:30:02:02
Primary VSM MAC : 00:50:56:b6:0c:b2
Primary VSM PKT MAC : 00:50:56:b6:35:3f
Primary VSM MGMT MAC : 00:50:56:b6:d5:12
Standby VSM CTRL MAC : 00:50:56:b6:96:f2
Management IPv4 address: 192.168.52.100
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Primary L3 Control IPv4 address: 192.168.54.2
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 1
Card packet VLAN: 1
Control type multicast: No
Card Headless Mode : Yes
Processors: 4
Processor Cores: 4
Processor Sockets: 1
Kernel Memory: 16669764
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: False
PC LB Algo: source-mac
Datapath portset event in progress : no
Licensed: Yes
! ports 1-6 connected to physical host A
interface GigabitEthernet1/0/1
description VMWARE ESXi Trunk
switchport trunk encapsulation dot1q
switchport mode trunk
switchport nonegotiate
spanning-tree portfast trunk
spanning-tree bpdufilter enable
spanning-tree bpduguard enable
channel-group 1 mode active
! ports 7-12 connected to phys host B
interface GigabitEthernet1/0/7
description VMWARE ESXi Trunk
switchport trunk encapsulation dot1q
switchport mode trunk
switchport nonegotiate
spanning-tree portfast trunk
spanning-tree bpdufilter enable
spanning-tree bpduguard enable
channel-group 2 mode activeok after deleteing the n1kv vms and vcenter and then reinstalling all I got the error again,
N1KV# 2013 Jun 18 17:48:12 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:48:13 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 18 17:48:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:48:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 18 17:48:41 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:48:42 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 18 17:49:10 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:49:11 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 18 17:49:35 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:49:36 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
2013 Jun 18 17:49:59 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
2013 Jun 18 17:50:00 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
Host A
~ # vemcmd show card
Card UUID type 2: 03000200-0400-0500-0006-000700080009
Card name:
Switch name: N1KV
Switch alias: DvsPortset-0
Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
Card domain: 2
Card slot: 1
VEM Tunnel Mode: L3 Mode
L3 Ctrl Index: 49
L3 Ctrl VLAN: 52
VEM Control (AIPC) MAC: 00:02:3d:10:02:00
VEM Packet (Inband) MAC: 00:02:3d:20:02:00
VEM Control Agent (DPA) MAC: 00:02:3d:40:02:00
VEM SPAN MAC: 00:02:3d:30:02:00
Primary VSM MAC : 00:50:56:b6:96:f2
Primary VSM PKT MAC : 00:50:56:b6:11:b6
Primary VSM MGMT MAC : 00:50:56:b6:48:c6
Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
Management IPv4 address: 192.168.52.100
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Primary L3 Control IPv4 address: 192.168.54.2
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 1
Card packet VLAN: 1
Control type multicast: No
Card Headless Mode : Yes
Processors: 4
Processor Cores: 4
Processor Sockets: 1
Kernel Memory: 16669764
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: False
PC LB Algo: source-mac
Datapath portset event in progress : no
Licensed: No
Host B
~ # vemcmd show card
Card UUID type 2: 03000200-0400-0500-0006-000700080009
Card name:
Switch name: N1KV
Switch alias: DvsPortset-0
Switch uuid: bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3
Card domain: 2
Card slot: 3
VEM Tunnel Mode: L3 Mode
L3 Ctrl Index: 49
L3 Ctrl VLAN: 51
VEM Control (AIPC) MAC: 00:02:3d:10:02:02
VEM Packet (Inband) MAC: 00:02:3d:20:02:02
VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
VEM SPAN MAC: 00:02:3d:30:02:02
Primary VSM MAC : 00:50:56:a8:f5:f0
Primary VSM PKT MAC : 00:50:56:a8:3c:62
Primary VSM MGMT MAC : 00:50:56:a8:b4:a4
Standby VSM CTRL MAC : 00:50:56:a8:30:d5
Management IPv4 address: 192.168.51.100
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Primary L3 Control IPv4 address: 192.168.54.2
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 1
Card packet VLAN: 1
Control type multicast: No
Card Headless Mode : No
Processors: 4
Processor Cores: 4
Processor Sockets: 1
Kernel Memory: 16669760
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: True
PC LB Algo: source-mac
Datapath portset event in progress : no
Licensed: Yes
I used the nexus 1000v java installer so I don't know what it keeps assigning the same UUID nor do I know how to change it.
Here is the other output you requested,
N1KV# show vms internal info dvs
DVS INFO:
DVS name: [N1KV]
UUID: [bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3]
Description: [(null)]
Config version: [1]
Max ports: [8192]
DC name: [Galaxy]
OPQ data: size [1121], data: [data-version 1.0
switch-domain 2
switch-name N1KV
cp-version 4.2(1)SV2(1.1a)
control-vlan 1
system-primary-mac 00:50:56:a8:f5:f0
active-vsm packet mac 00:50:56:a8:3c:62
active-vsm mgmt mac 00:50:56:a8:b4:a4
standby-vsm ctrl mac 0050-56a8-30d5
inband-vlan 1
svs-mode L3
l3control-ipaddr 192.168.54.2
upgrade state 0 mac 0050-56a8-30d5 l3control-ipv4 null
cntl-type-mcast 0
profile dvportgroup-26 trunk 1,51-57,110
profile dvportgroup-26 mtu 9000
profile dvportgroup-27 access 51
profile dvportgroup-27 mtu 1500
profile dvportgroup-27 capability l3control
profile dvportgroup-28 access 52
profile dvportgroup-28 mtu 1500
profile dvportgroup-28 capability l3control
profile dvportgroup-29 access 53
profile dvportgroup-29 mtu 1500
profile dvportgroup-30 access 54
profile dvportgroup-30 mtu 1500
profile dvportgroup-31 access 55
profile dvportgroup-31 mtu 1500
profile dvportgroup-32 access 56
profile dvportgroup-32 mtu 1500
profile dvportgroup-34 trunk 220
profile dvportgroup-34 mtu 9000
profile dvportgroup-35 access 220
profile dvportgroup-35 mtu 1500
profile dvportgroup-35 capability iscsi-multipath
end-version 1.0
push_opq_data flag: [1]
show svs neighbors
Active Domain ID: 2
AIPC Interface MAC: 0050-56a8-f5f0
Inband Interface MAC: 0050-56a8-3c62
Src MAC Type Domain-id Node-id Last learnt (Sec. ago)
0050-56a8-30d5 VSM 2 0201 1020.45
0002-3d40-0202 VEM 2 0302 1.33
I cannot add Host A to the N1KV it errors out with,
vDS operation failed on host 192.168.52.100, An error occurred during host configuration. got (vim.fault.PlatformConfigFault) exception
Host B (192.168.51.100) was added fine, then I moved a vmkernel to the N1KV which brought up the VEM and got the VEM flapping errors. -
Cisco Nexus 1000v stops inheriting
Guys,
I have an issue with the Nexus 1000v, basically the trunk ports on the ESXi hosts stop inheriting from the main DATA-UP link port profile, which means that not all VLANS get presented down that given trunk port, its like it gets completey out of sync somehow. An example is below,
THIS IS A PC CONFIG THAT'S NOT WOKRING CORRECTLY
show int trunk
Po9 100,400-401,405-406,412,430,434,438-439,446,449-450,591,850
sh run int po9
interface port-channel9
inherit port-profile DATA-UP
switchport trunk allowed vlan add 438-439,446,449-450,591,850 (the system as added this not user)
THIS IS A PC CONFIG THAT IS WORKING CORRECTLY
show int trunk
Po2 100,292,300,313,400-401,405-406,412,429-430,434,438-439,446,449-450,582,591,850
sh run int po2
interface port-channel2
inherit port-profile DATA-UP
I have no idea why this keeps happening, when i remove the manual static trunk configuration on po9, everything is fine, few days later, it happens again, its not just po9, there is at least 3 port-channel that it affects.
My DATA-UP link port-profile configuration looks like this and all port channels should reflect the VLANs allowed but some are way out.
port-profile type ethernet DATA-UP
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100,292,300,313,400-401,405-406,412,429-430,434,438-439,446,449-450,5
82,591,850
channel-group auto mode on sub-group cdp
no shutdown
state enabled
The upstream switches match the same VLANs allowed and the VLAN database is a mirror image between Nexus and Upstream switches.
The Cisco Nexus version is 4.2.1
Anyone seen this problem?
CheersUsing vMotion you can perform the entire upgrade with no disruption to your virtual infrastructure.
If this is your first upgrade, I highly recommend you go through the upgrade guides in detail.
There are two main guides. One details the VSM and overall process, the other covers the VEM (ESX) side of the upgrade. They're not very long guides, and should be easy to follow.
1000v Upgrade Guide:
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4_a/upgrade/software/guide/n1000v_upgrade_software.html
VEM Upgrade Guides:
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4_a/install/vem/guide/n1000v_vem_install.html
In a nutshell the procedure looks like this:
-Backup of VSM Config
-Run pre-upgrade check script (which will identify any config issues & ensures validation of new version with old config)
-Upgrade standby VSM
-Perform switchover
-Upgrade image on old active (current standby)
-Upgrade VEM modules
One decision you'll need to make is whether to use Update Manager or not for the VEM upgrades. If you don't have many hosts, the manual method is a nice way to maintain control on exactly what's being upgrade & when. It will allow you to migrate VMs off the host, upgrade it, and then continue in this manner for all remaining hosts. The alternate is Update Manager, which can be a little sticky if it runs into issues. This method will automatically put hosts in Maintenance Mode, migrate VMs off, and then upgrade each VEM one by one. This is a non-stop process so there's a little less control from that perspective. My own preference is any environment with 10 or less hosts, I use manual, for more than that let VUM do the work.
Let me know if you have any other questions.
Regards,
Robert -
Nexus 1000v port-channels questions
Hi,
I’m running vCenter 4.1 and Nexus 1000v and about 30 ESX Hosts.
I’m using one system uplink port profile for all 30 ESX Host; On each of the ESX host I have 2 NICs going to a Catalyst 3750 switch stack (Switch A), and another 2 NICs going to another Catalyst 3750 switch stack (Switch B).
The Nexus is configured with the “sub-group CDP” command on the system uplink port profile like the following:
port-profile type ethernet uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 1,800,802,900,988-991,996-997,999
switchport trunk native vlan 500
mtu 1500
channel-group auto mode on sub-group cdp
no shutdown
system vlan 988-989
description System-Uplink
state enabled
And the port channel on the Catalyst 3750 are configured like the following:
interface Port-channel11
description ESX-10(Virtual Machine)
switchport trunk encapsulation dot1q
switchport trunk native vlan 500
switchport trunk allowed vlan 800,802,900,988-991
switchport mode trunk
switchport nonegotiate
spanning-tree portfast trunk
end
interface GigabitEthernet1/0/18
description ESX-10(Virtual Machine)
switchport trunk encapsulation dot1q
switchport trunk native vlan 500
switchport trunk allowed vlan 800,802,900,988-991
switchport mode trunk
switchport nonegotiate
channel-group 11 mode on
spanning-tree portfast trunk
spanning-tree guard root
end
interface GigabitEthernet1/0/1
description ESX-10(Virtual Machine)
switchport trunk encapsulation dot1q
switchport trunk native vlan 500
switchport trunk allowed vlan 800,802,900,988-991
switchport mode trunk
switchport nonegotiate
channel-group 11 mode on
spanning-tree portfast trunk
spanning-tree guard root
end
Now Cisco is telling me that I should be using MAC pinning when doing a trunk to two different stacks , and that each interface on 3750 should not be configured in a port-channel like above, but should be configured as individual trunks.
First question: Is the above statement correct, are my uplinks configured wrong? Should they be configured individually in trunks instead of a port-channel?
Second questions: If I need to add the MAC pinning configuration on my system uplink port-profile can I create a new system uplink port profile with the MAC pinning configuration and then move one ESX host (with no VM on them) one at a time to that new system uplink port profile? This way, I could migrate one ESX host at a time without outages to my VMs. Or is there an easier way to move 30 ESX hosts to a new system uplink profile with the MAC Pinning configuration.
Thanks.Hello,
From what I understood, you have the following setup:
- Each ESX host has 4 NICS
- 2 of them go to a 3750 stack and the other 2 go to a different 3750 stack
- all 4 vmnics on the ESX host use the same Ethernet port-profile
- this has 'channel-group auto mode on sub-group cdp'
- The 2 interfaces on each 3750 stack are in a port-channel (just 'mode on')
If yes, then this sort of a setup is correct. The only problem with this is the dependance on CDP. With CDP loss, the port-channels would go down.
'mac-pinning' is the recommended option for this sort of a setup. You don't have to bundle the interfaces on the 3750 for this and these can be just regular trunk ports. If all your ports are on the same stack, then you can look at LACP. The CDP option would not be supported in the future releases. In fact, it is supposed to be removed from 4.2(1)SV1(2.1) but I still see the command available (ignore 4.2(1)SV1(4) next to it) - I'll follow up on this internally:
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_2_1_1/interface/configuration/guide/b_Cisco_Nexus_1000V_Interface_Configuration_Guide_Release_4_2_1_SV_2_1_1_chapter_01.html
For migrating, the best option would be as you suggested. Create a new port-profile with mac-pinning and move one host at a time. You can migrate VMs off the host before you change the port-profile and can remove the upstream port-channel config as well.
Thanks,
Shankar -
Nexus 5548UP lacp with IBM AIX P740
We are currently working in a lab to configure our first pair of 5548UP(with a 2232PP on each) with FCoE to an IBM p740 AIX server. On the Nexus side I have confugured the physical port e100/1/1 (2232pp) to be in a channel-group that will be part of a vpc with the other 5548UP switch, I am trunking all vlans in the etherchannel with the IBM server. Everything is working, i have the port-channel UP, the vfc and vpc when I use ''channel-group x mode ON'' on the physical ports and on the server side the 803.2ad is not active, it's configured ''roundRobin''.
Suppose I want to use LACP for the connections with the server should I configure the Nexus switch port with ''channel-group x mode active'' or ''channel-group x mode passive''? When the server is configured with ''802.3ad'' enabled and when I have ''channel-group x mode active'' or ''passive'' it doesn't work, the port-channel x does not come UP.
Does anyone have an explenation of how I should be configure?
ThanksHello,
Using LACP passive or active mode should not make much of a difference as long as one of the sides of the port-channel actively negotiates LACP. In most cases, we just configure both sides to be LACP active.
When you say the port-channel is not working when using LACP, what are the symptoms?
Are the physical ports in "I" state?'
'show port-channel summary' will show this
What does the output of "show lacp counters interface port-channel X" show?
This command will tell you if the Nexus 5K/2K is receiving LACPDUs from the IBM device (and if we are sending them). I would suggest to collect the LACP counters to verify that we are receiving the LACP packets from IBM, otherwise Nexus will not bring up the port-channel. Here is an example output from my lab switch:
5548-2019# show lacp counters interface port-channel 500
LACPDUs Marker Marker Response LACPDUs
Port Sent Recv Sent Recv Sent Recv Pkts Err
port-channel500
Ethernet1/15 16401 16399 0 0 0 0 0
Ethernet1/16 16400 16399 0 0 0 0 0
Regards,
Steven -
SCVMM Kicks out Nexus 1000V Uplink NIC Any ideas?
The SCVMM suddenly kicks out the Nexus 1000V Uplink NIC,
thus preventing me from remediating the change.
Also i get this error message
Using Hyper V as virtualization platformHello,
You can use one Ethernet port-profile with a channel-group command (like 'channel-group auto mode on mac-pinning') and assign it to all the vmnic interfaces that need to carry the same set of VLANs
The same port-profile can be used on other hosts too. The N1k would automatically bundle (port-channel) the interfaces that belong to the same ESX host (accomplished through the 'channel-group auto' command)
If you need the interfaces to carry separate sets of VLANs, then you need a different port-profile.
Port-profile is just a container for a common set of configuration that you can apply for multiple interfaces across multiple hosts.
Thanks,
Shankar -
Firewall ports for Nexus 1000v
hi all,
There is firewall between nexus 1000v and vcentre and ESX 4.1i hosts.
Could u pls advise which TCP/UDP ports to be opened for communication among Nexus1000v, vcentre and ESX hosts?
Thank you very much!
Best Regards,David,
Between your VSM & VC you'll need TCP ports 80 & 443 open
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_3/troubleshooting/configuration/guide/n1000v_trouble_5modules.html
Between your VEM & VSM you'll need port this should be layer 2 so no ports need to be open.
If you're using Layer 3 mode then enusre you have UDP 4785 open.
http://www.ciscosystemsverified.biz/en/US/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_3/system_management/configuration/guide/n1000v_system_3domain.pdf
Regards,
Robert -
I'm looking over the deployment guide for 1000Vs, and am not clear on the design. If I have a Nexus 4k connecting to a Nexus 5k, how does the Nexus 1000V fit? What I'm seeing is that typically a vpc is built between the Nexus 1k and a clustered upstream switch, such as Nexus 5ks, or VSS with 6500s. However, if I already have a vpc between a Nexus 4k and a pair of 5ks, what affect does adding 1ks to the configuration have? Or is the idea to move the vpc back to the 1000Vs instead of the between the 4k and 5ks? Or perhaps is using a 1000V more suited when you have blades that are pass through modules where each blade has its own NIC or there are blade switches (non Nexus 4k) in the chassis?
thank you,
Billhi bill
mainly there are two options
first option if to use the N1K with a clustered up stream switches as you mentioned vPC or VSS
in this case all what you need form the N1K/ESXi host is to use a normal portchannel and multihome th eport channel links to both of these switches ( this is a recommended solution if applicable )
option two is to use non-clustered switches like in your case the two 4K switches as the upstream switches with the N1K
and in this case you can use vPC host mode where the N1K with new releases uses mac-pining to chose uplink subgroup within the port channel
see below: -
Hello everyone
I am confused about how works the integration between N1K and UCS Manager:
First question:
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
I tried to read differnt documents, but I did not understand.
ThanksSince you have defined switchport mode access vlan 100 on uplink port-profile of Nexus 1000v, it sends all ethernet frames untagged(without 802.1q tag).
When you include in the vNIC profile the vlan 100 (not as native vlan) ONLY like below screenshot, untagged frames are dropped because UCS expects all frames received on this port as tagged frames.
When you change vNIC template to include default vlan as native vlan ONLY like below screen shot, you basically bridge two vlans (vlan 100 and vlan 1) because UCS FI now puts all untagged frames in vlan 1. and sends untagged frames to other ESXi host and ESXi host again bridge vlan 1 to vlan 100 with switchport mode access vlan 100 on uplink port profile. -
Nexus 1000v UCS Manager and Cisco UCS M81KR
Hello everyone
I am confused about how works the integration between N1K and UCS Manager:
First question:
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
I tried to read differnt documents, but I did not understand.
ThanksThis document may help...
Best Practices in Deploying Cisco Nexus 1000V Series Switches on Cisco UCS B and C Series Cisco UCS Manager Servers
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9902/white_paper_c11-558242.html
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
-Yes. Each ESX host with the VEM will have one or more dedicated NICs for the VEMs to communicate with the upstream network. These would be your 'type ethernet' port-profiles. The ustream network would need to bridge the vlan between the two physicall nics.
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
- The N1K port profiles are switchport access making them untagged. This would be the native vlan in ucs. If there is no native vlan in the UCS configuration, we do not have the upstream networking bridging the vlan.
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
- All ports on the UCS are effectively trunks and you can define what vlans are allowed on the trunk as well as what vlan is passed natively or untagged. In N1K, you will want to leave your vEthernet port profiles as 'switchport mode access'. For your Ethernet profiles, you will want them to be 'switchport mode trunk'. Use an used used vlan as the native vlan. All production vlans will be passed from N1K to UCS as tagged vlans.
Thank You,
Dan Laden
PDI Helpdesk
http://www.cisco.com/go/pdihelpdesk -
VM-FEX and Nexus 1000v relation
Hi
I am a new in virtulaization world and I need to know what is the relation between Cisco Nexus 1000v and Cisco VM-FEX?, and when to use VM-FEX and when to use Nexus 1000v.
RegardsAhmed,
Sorry for taking this long to get back to you.
Nexus 1000v is a virtualized switch and as such will require that any traffic coming in or leaving the VM will first need to pass through the virtualization layer, therefore causing a minimum delay that for some applications (VMs) can be catastrophic enough that may mean too much delay.
With VM-FEX you gain the option to bypass the virtualization layer with for example "Pass-Through" mode where the vmnics are really assigned and managed by the OS, minimizing the delay and making the VMs look as if they were directly attached, also, this offloads CPU workload in the mean time, optimizing the host/VM's performance.
The need for one or the other will be defined as always by the needs your organization/business has.
Benefits of VM-FEX (from cisco.com):
Simplified operations: Eliminates the need for a separate, virtual networking infrastructure
Improved network security: Contains VLAN proliferation
Optimized network utilization: Reduces broadcast domains
Enhanced application performance: Offloads virtual machine switching from host CPU to parent switch application-specific integrated circuits (ASICs)
Benefits of Nexus 1000v here on another post from Rob Burns:
https://supportforums.cisco.com/thread/2087541
https://communities.vmware.com/thread/316542?tstart=0
I hope that helps
-Kenny -
Alright folks,
just now messing with one of these...
My VM guy setup the VSM and i'm able to remote into the switch etc...however, I'm wanting to work the GUI magic and all i'm getting when entering the ip into my browser is what appears to be the directory structure
Index of /.
mode links bytes last-changed name
dr-x 3 120 Apr 25 2009 ./
drwx 13 260 Apr 22 21:16 ../
-r-- 1 20 Apr 25 2009 bundle_id.txt
dr-x 3 120 Apr 25 2009 cisco/
-rw- 1 1838 Apr 22 18:06 cisco_nexus_1000v_extension.xml
-r-- 1 229 Apr 22 18:07 index.xml
no nice GUI like the guide shows...
I'm running ver 4.0(4)SV1(1)
Helpppp!!!
thanks...
BruceAlright folks,just now messing with one of these...My
VM guy setup the VSM and i'm able to remote into the switch
etc...however, I'm wanting to work the GUI magic and all i'm getting
when entering the ip into my browser is what appears to be the
directory structureIndex of /.mode links bytes last-changed name
dr-x 3 120 Apr 25 2009 ./
drwx 13 260 Apr 22 21:16 ../
-r-- 1 20 Apr 25 2009 bundle_id.txt
dr-x 3 120 Apr 25 2009 cisco/
-rw- 1 1838 Apr 22 18:06 cisco_nexus_1000v_extension.xml
-r-- 1 229 Apr 22 18:07 index.xml
no nice GUI like the guide shows...
I'm running ver 4.0(4)SV1(1)
Helpppp!!!
thanks...
Bruce
Hi Bruce,
Check out the below link for GUI configuration of Nexus 1000V
http://www.ciscosystems.ro/en/US/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_2/getting_started/guide/n1000v_gsg_2setup.html
Hope to Help !!
Ganesh.H
Remember to rate helpful post
Maybe you are looking for
-
Reinstalling iTunes and getting message "service 'apple mobile device'failed to start.Verify that you have sufficient privileges to start system services"
-
I have not used my Ipod mini in a very long time today I was trying to connect it to the computer to erase/add new songs or "sync" it....I connected it and the do not disconnect logo appears and the computer recognizes new hardware, but when I go int
-
I have this problem with finder and vlc where if I minimize them to the dock I cannot restore them. For vlc the menu bar at the top changes and I have to go to 'Window-Main Window' to get the the window to appear. But for finder the menu bar does not
-
Duplicating format in all columns of table.
In Pages, when I'm working with tables, is there a way to set all cells to have same format? at the same time? opposed to going through EACH cell and changing the font and alignment to be the same in each cell? You can't highlight the entire table.
-
Can't start Thread from modal JDialog.
Hi, this is a part of my code. I can't start the scanThread from the object WaitingDl. But if i close the modal JDialog (WaitingDl) the scanThread starts, please help: Thread scanThread = new Thread() { public void run() { // d