TMS - Buffer check failed
hi Folks,
I am trying to release any request and I get the following error message:
ERROR: Buffer check failed
I've already checked the files permissions, updated the tp, re-configured the Route (my scenario the route is a single one).
Please, please, help me.
Thank you so much
Má
Hi,
Please check the following.
1. Check the profile \usr\sap\trans\bin\TP_DOMAIN_<SID>.PFL, whats the value of TRANSDIR?
2. Check whether Buffer folder is inside the Trans directory .
3. Give full permission to trans directory as well as its sub folders.
4. Looks like a problem with your /usr/sap/trans directory. Maybe authorization issue.
5. Goto STMS >> overview >> system >> double click on SID >> press on Trrasnport tool tab>> press change button and press save button . Do the same for all the SID's available in that system. This is to just re-activate the TP program.
Thanks and Regards,
Vimal
Similar Messages
-
Filesystem check failed, but filesystems are clean
Im running custom kernel and this might be related to it, but Im on my wits' end here and looking for pointers.
The problem is, Im getting filesystem check failed every time I boot my system. And it gives no apparent reason
for it to happen. I have fsck'd my partitions many times and they are clean. My hwclock is in time and rc.conf is set
to 'localtime'. The problem didn't occurs on the previous kernel (2.6.18) I had, so I've been using its running config to
compile the new one (2.6.23). The thing is, the previous kernel works fine, no filesystem check failed in boot. Only
difference between those two is I had to enable HOTPLUG in the newer kernel to get udev working, otherwise it would
complain about failing netlink socket in initscript.
As a temporary solution, I commented out the filesystem check from the rc.sysinit and it boots further. This time
it fails to mount my /boot/ and /home/ directory and fails to activate my swap. Effectively only root is mounted, but
after logging in, "mount -a" works without any problems and I can use my system normally.
I have compiled all(?) the needed modules to the kernel, so initramfs shouldn't be needed, but I've tried it anyway, no
luck there. The system is build with 2009.08 core install disc, no packages updated as far as I recall.
fstab:
#none /dev/pts devpts defaults 0 0
#none /dev/shm tmpfs defaults 0 0
/dev/hdb /media/cdrom auto ro,user,noauto,unhide 0 0
#/dev/dvd /media/dvd auto ro,user,noauto,unhide 0 0
#/dev/fd0 /media/fl auto user,noauto 0 0
/dev/disk/by-uuid/728c65f2-a84f-401f-9899-17020758b829 /boot ext3 defaults 0 1
/dev/disk/by-uuid/2767f772-203a-4fe9-ac4d-7c8754abc4c8 swap swap defaults 0 0
/dev/disk/by-uuid/b0b958c4-5f24-414a-8826-6df956f0815b / reiserfs defaults 0 1
/dev/disk/by-uuid/e83b7114-86fe-4e8f-9e95-0d92b8e50d1a /home reiserfs defaults 0 1
dmesg:
Linux version 2.6.23-xbox (root@xbox) (gcc version 4.1.2) #3 Sat Oct 2 14:20:54 EEST 2010
BIOS-provided physical RAM map:
BIOS-e820: 0000000000000000 - 000000000009f000 (usable)
BIOS-e820: 000000000009f000 - 0000000000100000 (reserved)
BIOS-e820: 0000000000100000 - 0000000003c00000 (usable)
BIOS-e820: 0000000003c00000 - 0000000004000000 (reserved)
60MB LOWMEM available.
Entering add_active_range(0, 0, 15360) 0 entries of 256 used
Zone PFN ranges:
DMA 0 -> 4096
Normal 4096 -> 15360
Movable zone start PFN for each node
early_node_map[1] active PFN ranges
0: 0 -> 15360
On node 0 totalpages: 15360
DMA zone: 32 pages used for memmap
DMA zone: 0 pages reserved
DMA zone: 4064 pages, LIFO batch:0
Normal zone: 88 pages used for memmap
Normal zone: 11176 pages, LIFO batch:1
Movable zone: 0 pages used for memmap
DMI not present or invalid.
Allocating PCI resources starting at 10000000 (gap: 04000000:fc000000)
Built 1 zonelists in Zone order. Total pages: 15240
Kernel command line: root=/dev/hda3 devfs=mount kbd-reset xbox=hdd
Enabling fast FPU save and restore... done.
Enabling unmasked SIMD FPU exception support... done.
Initializing CPU#0
PID hash table entries: 256 (order: 8, 1024 bytes)
Detected 733.370 MHz processor.
Console: colour dummy device 80x25
console [tty0] enabled
Dentry cache hash table entries: 8192 (order: 3, 32768 bytes)
Inode-cache hash table entries: 4096 (order: 2, 16384 bytes)
Memory: 57652k/61440k available (1764k kernel code, 3380k reserved, 470k data, 136k init, 0k highmem)
virtual kernel memory layout:
fixmap : 0xffffb000 - 0xfffff000 ( 16 kB)
vmalloc : 0xc4800000 - 0xffff9000 ( 951 MB)
lowmem : 0xc0000000 - 0xc3c00000 ( 60 MB)
.init : 0xc0332000 - 0xc0354000 ( 136 kB)
.data : 0xc02b90ae - 0xc032ea60 ( 470 kB)
.text : 0xc0100000 - 0xc02b90ae (1764 kB)
Checking if this processor honours the WP bit even in supervisor mode... Ok.
Calibrating delay using timer specific routine.. 1467.98 BogoMIPS (lpj=2935965)
Mount-cache hash table entries: 512
CPU: After generic identify, caps: 0383f9ff 00000000 00000000 00000000 00000000 00000000 00000000 00000000
CPU: L1 I cache: 16K, L1 D cache: 16K
CPU: L2 cache: 128K
CPU: After all inits, caps: 0383f9ff 00000000 00000000 00000040 00000000 00000000 00000000 00000000
Compat vDSO mapped to ffffe000.
CPU: Intel Celeron (Coppermine) stepping 0a
Checking 'hlt' instruction... OK.
NET: Registered protocol family 16
PCI: Using configuration type 1
Setting up standard PCI resources
SCSI subsystem initialized
libata version 2.21 loaded.
usbcore: registered new interface driver usbfs
usbcore: registered new interface driver hub
usbcore: registered new device driver usb
PCI: Probing PCI hardware
PCI: Probing PCI hardware (bus 00)
PCI: Cannot allocate resource region 7 of bridge 0000:00:08.0
PCI: Cannot allocate resource region 8 of bridge 0000:00:08.0
PCI: Cannot allocate resource region 9 of bridge 0000:00:08.0
PCI: Bridge: 0000:00:08.0
IO window: disabled.
MEM window: disabled.
PREFETCH window: disabled.
PCI: Failed to allocate mem resource #2:80000@f8000000 for 0000:01:00.0
PCI: Failed to allocate mem resource #6:10000@f8000000 for 0000:01:00.0
PCI: Bridge: 0000:00:1e.0
IO window: disabled.
MEM window: fd000000-fdffffff
PREFETCH window: f0000000-f7ffffff
PCI: Setting latency timer of device 0000:00:08.0 to 64
NET: Registered protocol family 2
Time: tsc clocksource has been installed.
IP route cache hash table entries: 1024 (order: 0, 4096 bytes)
TCP established hash table entries: 2048 (order: 2, 16384 bytes)
TCP bind hash table entries: 2048 (order: 1, 8192 bytes)
TCP: Hash tables configured (established 2048 bind 2048)
TCP reno registered
checking if image is initramfs... it is
Freeing initrd memory: 325k freed
Enabling Xbox eject problem workaround.
fuse init (API version 7.8)
io scheduler noop registered
io scheduler deadline registered (default)
io scheduler cfq registered
xboxfb: nVidia device/chipset 10DE02A0
xboxfb: Detected 64MB of system RAM
xboxfb: Using 4M framebuffer memory
i2c-xbox.o version 0.0.1
i2c-xbox.o: Found nVidia XBOX nForce SMBus controller.
i2c-xbox.o: SMBus bus detected and initialized
xbox-tv-i2c: Using 'SMBus adapter at c000'!
xboxfb: Setting TV mode from EEPROM (NTSC)
xboxfb: detected conexant encoder
xboxfb: Setting cable type from AVIP ID: HDTV (Component video)
xboxfb: RIVA MTRR set to ON
Console: switching to colour frame buffer device 80x30
xboxfb: PCI nVidia NV20 framebuffer ver 0.9.5b-xbox (XboxGeForce3, 4MB @ 0xF3C00000)
Real Time Clock Driver v1.12ac
Linux agpgart interface v0.102
[drm] Initialized drm 1.1.0 20060810
RAMDISK driver initialized: 16 RAM disks of 4096K size 1024 blocksize
loop: module loaded
forcedeth.c: Reverse Engineered nForce ethernet driver. Version 0.60.
PCI: Setting latency timer of device 0000:00:04.0 to 64
eth0: forcedeth.c: subsystem: 00000:0000 bound to 0000:00:04.0
Uniform Multi-Platform E-IDE driver Revision: 7.00alpha2
ide: Assuming 33MHz system bus speed for PIO modes; override with idebus=xx
NFORCE: IDE controller at PCI slot 0000:00:09.0
NFORCE: chipset revision 212
NFORCE: not 100% native mode: will probe irqs later
NFORCE: 0000:00:09.0 (rev d4) UDMA100 controller
ide0: BM-DMA at 0xff60-0xff67, BIOS settings: hda:DMA, hdb:DMA
Probing IDE interface ide0...
hda: WDC WD2500JB-00FUA0, ATA DISK drive
hdb: PHILIPS XBOX DVD DRIVE, ATAPI CD/DVD-ROM drive
hda: host side 80-wire cable detection failed, limiting max speed to UDMA33
hda: selected mode 0x42
hdb: selected mode 0x42
ide0 at 0x1f0-0x1f7,0x3f6 on irq 14
Probing IDE interface ide1...
hda: max request size: 512KiB
hda: 488397168 sectors (250059 MB) w/8192KiB Cache, CHS=30401/255/63, UDMA(33)
hda: cache flushes supported
hda: hda1 hda2 hda3 hda4
hdb: ATAPI DVD-ROM drive, 128kB Cache, UDMA(33)
Uniform CD-ROM driver Revision: 3.20
ohci_hcd: 2006 August 04 USB 1.1 'Open' Host Controller (OHCI) Driver
PCI: Setting latency timer of device 0000:00:02.0 to 64
ohci_hcd 0000:00:02.0: OHCI Host Controller
ohci_hcd 0000:00:02.0: new USB bus registered, assigned bus number 1
ohci_hcd 0000:00:02.0: irq 1, io mem 0xfed00000
usb usb1: configuration #1 chosen from 1 choice
hub 1-0:1.0: USB hub found
hub 1-0:1.0: 4 ports detected
PCI: Setting latency timer of device 0000:00:03.0 to 64
ohci_hcd 0000:00:03.0: OHCI Host Controller
ohci_hcd 0000:00:03.0: new USB bus registered, assigned bus number 2
ohci_hcd 0000:00:03.0: irq 9, io mem 0xfed08000
usb usb2: configuration #1 chosen from 1 choice
hub 2-0:1.0: USB hub found
hub 2-0:1.0: 2 ports detected
USB Universal Host Controller Interface driver v3.0
mice: PS/2 mouse device common for all mice
i2c /dev entries driver
usb 1-3: new low speed USB device using ohci_hcd and address 2
usb 1-3: configuration #1 chosen from 1 choice
input: DELL DELL USB Keyboard as /devices/pci0000:00/0000:00:02.0/usb1/1-3/1-3:1.0/input/input0
usbcore: registered new interface driver usbkbd
drivers/hid/usbhid/usbkbd.c: :USB HID Boot Protocol keyboard driver
usbcore: registered new interface driver usbmouse
drivers/hid/usbhid/usbmouse.c: v1.6:USB HID Boot Protocol mouse driver
TCP cubic registered
drivers/rtc/hctosys.c: unable to open rtc device (rtc0)
Freeing unused kernel memory: 136k freed
ReiserFS: hda3: found reiserfs format "3.6" with standard journal
ReiserFS: hda3: using ordered data mode
ReiserFS: hda3: journal params: device hda3, size 8192, journal first block 18, max trans len 1024, max batch 900, max commit age 30, max trans age 30
ReiserFS: hda3: checking transaction log (hda3)
ReiserFS: hda3: Using r5 hash to sort names
NET: Registered protocol family 1
spurious 8259A interrupt: IRQ7.
udev: starting version 141
df -h after "mount -a":
Filesystem Size Used Avail Use% Mounted on
/dev/disk/by-uuid/b0b958c4-5f24-414a-8826-6df956f0815b
7.4G 2.1G 5.3G 29% /
/dev/hda1 99M 11M 83M 12% /boot
/dev/hda4 226G 39M 226G 1% /home
Ok, something is definately wrong there, only root is by-uuid
blkid:
/dev/hda3: UUID="b0b958c4-5f24-414a-8826-6df956f0815b" TYPE="reiserfs"
/dev/hda2: TYPE="swap" UUID="2767f772-203a-4fe9-ac4d-7c8754abc4c8"
/dev/hda4: UUID="e83b7114-86fe-4e8f-9e95-0d92b8e50d1a" TYPE="reiserfs"
/dev/hda1: UUID="728c65f2-a84f-401f-9899-17020758b829" SEC_TYPE="ext2" TYPE="ext3"
Should I try newer udev? Can I even use the latest with 2.6.23?Mounting Local Filesystems fails
Mount: Special device /dev/disk/by-uuid/728c65f2-a84f-401f-9899-17020758b829 does not exist
Mount: Special device /dev/disk/by-uuid/e83b7114-86fe-4e8f-9e95-0d92b8e50d1a does not exist
so does Activating swap.
still, ls -la /dev/disk/by-uuid/ gives me:
lrwxrwxrwx 1 root root 10 2010-10-02 22:45 2767f772-203a-4fe9-ac4d-7c8754abc4c8 -> ../../hda2
lrwxrwxrwx 1 root root 10 2010-10-02 22:45 728c65f2-a84f-401f-9899-17020758b829 -> ../../hda1
lrwxrwxrwx 1 root root 10 2010-10-02 22:45 b0b958c4-5f24-414a-8826-6df956f0815b -> ../../hda3
lrwxrwxrwx 1 root root 10 2010-10-02 22:45 e83b7114-86fe-4e8f-9e95-0d92b8e50d1a -> ../../hda4
should I have /boot and /home in /dev?
Full system upgrade gave me the same issue. Even after udev downgrade (udev-142 is the latest I can use with 2.6.23).
Edit:
Changed my fstab back from by-uuid to hdaX, didn't help. Strangely all hdaX are in /dev/ after boot, but the symlinks are missing.
Last edited by TelaKeppi (2010-10-02 21:22:53) -
How can I stop a task sequence if a custom HTA preflight check fails?
In our currently deployment method, we launch an HTA program before initiating the OSD process. This is only when run from the RAP menu, not via PXE. When a user initiates OSD through that menu, they get a message prompting them to close Outlook, and
a countdown of 5 mins, then OSD starts. They also have the ability to click on an 'OK' button to proceed on their own.
I've created a new script which checks WMI if Outlook and/or OCS are open, and if the machine is running on battery, spit out a "Failed" response and stop the HTA. I've also added a "recheck" button to re-do the check, and an 'OK
button if people jsut want to continue.
I'm curious if there is a way to prevent the task sequence from continuing if any of those conditions arent met. Currently it just pops up and says "Failed, Cannot conitue", but if they close the window, the task sequence thinks the program
has run, and the OSD migration starts. I'd like to be able and get the script to cancel the OSD process if a check fails.
Has anyone had success with this, using WINXP? I'd use the MS pre-flight check but it's only for WIN7.Interesting. Thanks for the response. Is there anybody out there that can assist with VBS part of the solution?
Here's the code I'm working with. Currently the battery piece isnt working as it should but I can figure that our, eventually. I'd like to get Jason's proposed solution in the code. If this isn't the right place, I'll take this somewhere
else.
<html xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en">
<head>
<title>OSD Preflight checks</title>
<HTA:APPLICATION
APPLICATIONNAME="OSD Preflight checks"
ID="objOSDPreReqChecks"
SCROLL="no"
CONTEXTMENU="no"
SINGLEINSTANCE="no"
MAXIMIZEBUTTON="no"
MINIMIZEBUTTON="no"
WINDOWSTATE="normal"/>
<!-- #region STYLEs-->
<style type="text/css">
H1{color:Black;text-align:center;font-family: Arial, Helvetica, sans-serif;font-size: 26px;}
p{font-family:"Arial";font-size:10px;}
fail{color:Red;text-align:center;}
.Version {float:left; font-size:1.0em;font-style:italic;color:#888888;font-weight:bold;}
.Header1 {width: 180px; text-align: right;font-weight:bold;}<!-- '1st column heading -->
H2 {font-family: Arial, Helvetica, sans-serif; text-align: center;}
H3 {font-style: italic;}
.style2 {width: 180px; text-align: left;}
.Header2 {width: 150px; text-align: right;font-weight:bold;}<!-- '2nd column heading -->
.style4 {width: 410px; text-align: left;}
.StatusBar
font-family: Arial, Helvetica, sans-serif;
text-align: center;
.hidden {display: none; visibility: hidden;}
</style><!-- #endregion -->
</head>
<script language="VBScript" type="text/vbscript">
'======================================================================================
' Script
' Version
' Purpose To check a machine is suitable for taking an OS deployment
'======================================================================================
'Features
' Modular design
' Verbose "Debug Mode"
' In-built data validation
' Custom error handling
' Custom error codes - 90x0
' Generic WMI handler
'BUGfix: Change CLng to CDbl to avoid overflow (in GetRAM)
'fixed - moved head section to top to become head > script > body
'fixed - fCheckModel display with leading ,
'fixed - fgetmodels dictionary list
Option Explicit
' #region GLOBAL DECLARATIONS: Persistent fold region
'======================================================================================
'GLOBAL Vars
'Things to just display (in GUI)
Dim strRAM
Dim strCPUInfo
Dim strCPUName
Dim strCPUDesc
Dim iCPUCount
Dim iCPUCoreCount
Dim iRAM
Dim strBIOSver, strBIOSDate, strBIOSInfo
'Time related
Dim TimerInterval 'timer to refresh HTA at start
Dim iTimer 'abort timer
Const iAbortTimeout=300000 'delay before window closes (in milliseconds)
Dim pbTimerID
Dim pbHTML
Dim pbWaitTime
Dim pbHeight
Dim pbWidth
Dim pbBorder
Dim pbUnloadedColor
Dim pbLoadedColor
Dim pbStartTime
'Dictionary
Dim objModelsDict,colKeys,strKey 'models
Dim objApprovedMakesDict
'Misc GLOBAL vars
Dim blnDebug 'set TRUE to trigger debug mode
Dim bAbortBuild 'Boolean flag to abort or not abort
Dim strTemp 'throwaway/scratch
Dim strNamespace 'wmi default namespace for ANY machine
Dim strComputer 'wmi reference to current machine, just .
Dim strService 'WMI service
Dim strQuery 'custom WQL
Dim ErrMsg 'custom error messages
Dim iErrMode 'State machine for error mode
Dim lFlags 'WMI flag
Dim strDisks
'Pre-requisites - things that will cause build to abort if values do not meet spec
Dim strHTAVendor 'Make of hardware
Dim strHTAVendorState
Dim strHTAModel 'Model of hardware
Dim strHTAModelState 'Model state
Dim strHTARAM 'RAM
Dim strHTARAMState 'RAM state
Dim strHTACPUSpeed 'Processor speed
Dim strHTACPUCores 'Number of cores
Dim strHTACPUFullInfo 'CPU + cores
Dim strHTAHDD 'Disk info
Dim strHTAHDDState 'Disk state
Dim strHTACheckRAW 'NTFS check
Dim strHTAArchitecture 'Processor support
Dim strHTAProduct 'Product ID
Dim strHTAOutlook 'Outlook running
Dim strHTAOutlookState 'Outlook state
Dim strHTABattery 'Battery check
Dim strHTABatteryState 'Battery state
'for WQL filters
Dim strWQLPCInfo 'Pre-req - (1) for various inc. domain role (servers)
Dim strWQLRAM 'Pre-req - (2) RAM
Dim strWQLCPU 'Pre-req - CPU speed string (not int)
Dim strWQLBootOrder 'Pre-req - Boot order string
Dim strWQLSATAMode 'Pre-req - HDD mode
Dim strWQLGenericBIOS
Dim strWQLCPUCount 'Pre-req - how many CPUs
Dim strWQLCPUInfo
Dim strWQLFSType 'Pre-req - Check HDD not RAW (i.e. is NTFS)
Dim strWQLDisks 'Disks
Dim strWQLChassis 'Machine type
Dim strWQLID 'Unique code from OEM
Dim strWQLProc 'is Outlook running = False
Dim strWQLBattery 'is on Battery = False
'State
Const cProblem = " Problem!"
Const cRunAgain =" RunCheck: Run System Check Again"
Const cSuccess = " Success!"
Const cPassed=" Pass"
Const cFail=" Fail"
'Pre-requisite to check: SET VALUES HERE vvvvvvvvvvvvvvvv
Const cApprovedOEM="Hewlett-Packard"
Const LegacyOEM1="Dell Inc."
Const LegacyOEM2="IBM"
Const cMinimumMemoryMB = 1000 'RAM in MB
'Const cMinimumMemoryMB = 1000000 'force fail test data RAM in MB
Const cMinFS="NTFS"
' Const cMinFS="HPFS" 'force fail test data
Const iMinCores=1
'Const iMinCores=10099 'force fail cores test data
Const iMinCPUSpeed=2 '20 'in GHz
'Const iMinCPUSpeed=90000 'in GHz
Const iMinCPUArch=32
'Const iMinCPUArch=64
' #endregion
' To hide anything use ID.className = "hidden", to show set to "", e.g. NotFoundArea.className = "hidden"
Sub Window_Onload
Err.Clear
VersionSpan.InnerText = objOSDPreReqChecks.Version 'Get version
self.focus
self.moveTo 100,100 'Move window top left
StatusBar.InnerText="Validating machine..."
document.body.style.cursor = "wait" 'hourglass cursor
'Call PreflightChecks 'use for testing as a VBS only, otherwise HTA timer will call below
TimerInterval = window.setInterval("PreflightChecks",10)
End Sub
Function PreflightChecks
' #region HEADER NOTES: Persistent fold region
'Version history
'ver 5 OCTOBER 2011 - added error handler
'ver 3rd Nov - removed HPonly queries
'// Solution: Custom Script for use with MDT - Adapted from hardwareinfo.vbs Mikael Nystrom – http://deploymentbunny.com
'Typical BIOS content
'Processor Speed = 2133/1066 MHz
'Boot Order = Network Controller,ATAPI CD-ROM Drive,USB device,Hard Drive,Diskette Drive,PnP Device #2,PnP Device #3,PnP Device #4,PnP Device #5,PnP Device #6,PnP Device #7,PnPe #8,PnP Device #9,PnP Device #10,PnP Device #11
'SATA (disk) mode: *IDE,--,RAID,-- or IDE,*AHCI,RAID
'On Error Resume Next
' #endregion
' #region CONSTANTS: Persistent fold region
'======================================================================================
'Fields available in HP BIOS
Const sAsset = "Notebook Asset Tag"
Const sOwner = "Notebook Ownership Tag"
Const sMan = "Manufacturer"
Const sNoteModel = "Notebook Model"
Const sCPU = "Processor Type"
Const sCPUSpeed = "Processor Speed"
Const sRAM = "Memory Size"
Const sModel = "Product Name"
Const sBIOSName ="System BIOS"
Const sBIOSVer = "BIOS Version"
Const sBIOSDate = "BIOS Date"
'Other BIOS stuff you could use too
'Const sOwnerTag = "Enter Ownership Tag"
'Const sBIOS = "PCID"
'Const sBIOS = "Define Custom URL"
'Const sBIOS = "Set Alarm Time"
'Const sBIOS = "PCID Version"
Const TextMode="1" 'text case sensitive for dict obj
'WMI core constants
Const wbemFlagReturnImmediately = 16 'wmi - Causes the call to return immediately.
Const wbemFlagForwardOnly = 32 'wmi - Causes a forward-only enumerator to be returned.
'Forward-only enumerators are generally much faster and
'use less memory than conventional enumerators, but don't allow calls to SWbemObject.Clone_
'Advisory config values - as in "you want to the change these"
Dim strHTABootOrder
Dim strHTASATAMode
'Dim strHTACPU
' #endregion
'======================================================================================
' #region WQL: Persistent fold region
lFlags = wbemFlagReturnImmediately + wbemFlagForwardOnly
'Queries of things to check (HP)
strWQLBootOrder = "select Name, value from HP_BIOSSetting where Name='Boot order'"
strWQLSATAMode = "select Name, value from HP_BIOSSetting where (Name='SATA emulation' or name='SATA device mode')"
strWQLDisks ="SELECT * FROM Win32_DiskDrive where mediatype like 'Fixed%hard disk%'" 'win32_disk only avail after W7
strWQLFSType ="SELECT * from Win32_LogicalDisk where DriveType='3'" 'only bother with HDDs
'Generic WMI query strings
strWQLGenericBIOS="SELECT Manufacturer,SMBIOSBIOSVersion,ReleaseDate FROM Win32_BIOS WHERE PrimaryBIOS = True"
strWQLCPUCount= "SELECT NumberOfProcessors,NumberOfLogicalProcessors from Win32_ComputerSystem"
strWQLCPUInfo="SELECT Name,DataWidth,description,MaxClockSpeed,NumberofCores,NumberOfLogicalProcessors from Win32_Processor"
strWQLPCInfo="SELECT Domain,DomainRole,SystemType,Manufacturer,Model,TotalPhysicalMemory FROM Win32_ComputerSystem"
' strWQLPCInfo="SELECT Domain,DomainRole,SystemType,Manufacturer FROM Win32_ComputerSystem"
strWQLChassis="SELECT ChassisTypes from Win32_SystemEnclosure"
strWQLID="SELECT IdentifyingNumber,UUID from Win32_ComputerSystemProduct"
strWQLRAM="SELECT * FROM Win32_PhysicalMemory"
strWQLProc="SELECT * FROM Win32_Process"
strWQLBattery="SELECT * FROM BatteryStatus Where Voltage > 0"
' #endregion
' #region MAIN algorithm
'=====================================================================================================
' MAIN
'Algorithm
'1) Check make (vendor)
'2) Check model (in list)
'3) Check RAM >x
'4) Check HDD TYPE (HDD is not RAW)
'5) Check CPU architecture
'6) Check outlook
'7) Check battery
'=====================================================================================================
'Initialise
window.clearInterval(TimerInterval) 'Reset timer to 0
' blnDebug=True
blnDebug=False
bAbortBuild=False 'default to DON'T abort
' bAbortBuild=True
'Build list of approved vendors
Set objApprovedMakesDict = CreateObject("Scripting.Dictionary")
objApprovedMakesDict.comparemode=VBTextCompare
objApprovedMakesDict.add cApprovedOEM,"OK"
objApprovedMakesDict.add LegacyOEM1,"OK"
objApprovedMakesDict.add LegacyOEM2,"OK"
objApprovedMakesDict.add "Lenovo","Testdata"
If blnDebug Then Stop
'1) all machines check make
strHTAVendor=fCheckVendor(strWQLGenericBIOS) 'check vendor in BIOS - if vendor not approved ABORT without proceeding
If bAbortBuild=True Then
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "FATAL ERROR - goodbye cruel world"
iTimer = window.setTimeout("Abort", iAbortTimeout, "VBScript")
Else
StatusBar.InnerText="Vendor: " & strHTAVendor & vbTab & " " & strHTAVendorState
'2) Discover current Model
strHTAModel=fGetModelName(strWQLPCInfo) 'get model name from WMI
strHTAModel=fUniversalCheckData(strHTAModel,"'Discover Model - fGetModelName'") 'validate
Call fGetModels 'get list of all valid models (from text file)
strHTAModel=fCheckModel(strHTAModel)
'2a) Model number (optional)
strHTAProduct=fGetComputerSystemProdIDNumber(strWQLID) 'manufacturer's product ID
strHTAProduct=fUniversalCheckData(strHTAProduct,"'Discover ID - fGetComputerSystemProdIDNumber'")
' StatusBar.InnerText=StatusBar.InnerText & VbCrLf & vbTab & "Product Code: " & vbTab & strHTAProduct
'3) Check installed Memory
strHTARAM=fGetRAM(strWQLRAM) 'find RAM size
strHTARAM=fUniversalCheckData(strHTARAM,"'Detect RAM - fCheckRAM'")
strHTARAM=fCheckRAM(strHTARAM) 'check RAM meets req
If strHTARAMState=cFail Then Exit Function
'4) Disk format IS NTFS
strDisks=fGetDrives(strWQLFSType) 'Get formatting info for all drives
strHTACheckRAW=fUniversalCheckData(strDisks,"'Detect filesystem - fCheckNTFS'") 'Validate data
strHTACheckRAW=fCheckNTFS(strDisks) 'Check FS format is acceptable (not RAW)
If strHTACheckRAW=cFail Then Exit Function
'Generic CPU calls
strHTACPUFullInfo="CPUs:" & fGetCPUInfo(strWQLCPUInfo) & " with CPU cores:" & iCPUCoreCount
strBIOSInfo="BIOS version: " & strBIOSver & ", dated " & strBIOSDate
'5a) CPU Speed check (info from http://www.robvanderwoude.com/wmiexamples.php)
strCPUInfo=WMI(strWQLCPUInfo,strNamespace) 'Get CPU details
strTemp=split(strCPUInfo,"@"): strHTACPUSpeed=strTemp(1)
strHTACPUSpeed=fUniversalCheckData(strHTACPUSpeed,"'Check processor - fCheckCPUSpeed'") 'Validate data
strHTACPUSpeed=fCheckCPUSpeed(strHTACPUSpeed) 'Check CPU clock speed
'5b) cores check
strHTACPUCores=fUniversalCheckData(iCPUCoreCount,"Check core count - fCheckCores") 'Validate data
iCPUCoreCount=fCheckCores(iCPUCoreCount) 'pass or fail?
'5c) CPU address width
strHTAArchitecture=fUniversalCheckData(strHTAArchitecture,"Check core count - fCheckCores") 'Validate data
strHTAArchitecture=fCheckCPUArch(strHTAArchitecture)
'6) Check outlook
strHTAOutlook=fCheckProcess(strWQLProc)
'7) Check Battery
strHTABattery=fCheckBattery(strWQLBattery)
'end checkss
document.body.style.cursor = "default"
'Display hardware values in GUI (in table)
Vendor.innerhtml = strHTAVendor 'Use str...var..STATE if you want Pass/fail text instead
Model.innerhtml = strHTAModel
Product.innerhtml = strHTAProduct
RAM.innerhtml = strHTARAM
CPUspeed.innerhtml = strHTACPUSpeed
CPUInfo.innerhtml = strHTACPUFullInfo
HDDFS.innerhtml = strHTACheckRAW
CapableArchitecture.innerhtml=strHTAArchitecture
BIOSversion.innerhtml = strBIOSver
BIOSDate.innerhtml = strBIOSDate' CPUName.innerhtml = strCPUDesc 'GetCPUName
End If
'======================================================================================
' #endregion
End Function
'generic WMI queries, by field and namespace
Function WMI(strQuery,strNameSpace)
'Aim: generic WMI calls
'return value of BIOS
On Error Resume Next
Dim colItems,objItem
Dim objWMI
Const strService = "winmgmts:{impersonationlevel=impersonate}//" 'binding to WMI
Const strComputer = "." 'this machine
Set objWMI = GetObject(strService & strComputer & strNamespace) 'GLOBAL wmi
Set colItems = objWMI.ExecQuery(strQuery,,lFlags)
For Each objItem In colItems
If Err Then
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "WMI query: " & strQuery & " in " & strNamespace & objItem.Name
Call ErrHandler("WMI error " & strQuery,1)
Else
WMI=objItem.Name 'Return value
End If
Next
End Function
Function fGetModelName(strWQLPCInfo)
'Aim: Get model name from BIOS - WMI field sometimes varies if laptop, so try two
'Return STRING: Model string from BIOS or "UNKNOWN" if null
On Error Resume Next
Dim colPCInfo,objPCItem
Dim strModel
Set colPCInfo = GetObject("winmgmts:").ExecQuery(strWQLPCInfo,"WQL",lFlags)
If Err Then
Call ErrHandler("fGetModelName: Error querying WMI " & strWQLPCInfo,2)
Else
For Each objPCItem In colPCInfo
If Not IsNull(objPCItem.Model) Then
strModel=objPCItem.Model
' iRAM=objPCItem.TotalPhysicalMemory
Else
If (strHTAVendor=cApprovedOEM And IsLaptop = True) Then ' resort to HP specific query for older laptops
'Notebook
strModel=QueryHPBIOS(sNoteModel)
if strModel="" then strModel=QueryHPBIOS(sModel) 'try alt value
Else
strModel=QueryHPBIOS(sModel)
End If
End If
Next
End If
If strModel = "" Then
fGetModelName = "UNKNOWN"
Model.style.visibility="hidden"
Else
fGetModelName=strModel
End If
End Function
'====================================================
'====================================================
Function fGetRAM(strQuery)
'Aim: get RAM installed. NB Win32_ComputerSystem::TotalPhysicalMemory may not be accurate
'Return integer
On Error Resume Next 'equiv to Err.Clear
Dim colItems, item
Dim iTotalMemory
Set colItems = GetObject("winmgmts:").ExecQuery(strQuery,"WQL",lFlags)
If Err Then
Call ErrHandler("fGetRAM: Error querying " & strQuery,2)
Else
iTotalMemory = 0
For Each item In colItems
iTotalMemory = iTotalMemory + CDBL(item.Capacity)/(1024^2)
Next
End If
If iTotalMemory = "" Then
fGetRAM = "RAM UNKNOWN"
RAM.style.visibility="hidden"
Else
fGetRAM=iTotalMemory
End If
End Function
'====================================================
'====================================================
Function fGetCPUInfo(strQuery)
'Aim: query WMI for CPU info - number and number of cores
'Return: function=CPU count, var for the cores: iCPUCoreCount, strHTAArchitecture, strCPUDesc
On Error Resume Next
Dim colItems, objItem
Dim NumberOfProcessors
Set colItems = GetObject("winmgmts:").ExecQuery(strQuery,"WQL",lFlags)
If Err Then
Call ErrHandler("GetCPUInfo: Error querying " & strQuery,2)
Else
For Each objItem In colItems
If Err Then
Else
If Not IsNull(objItem.NumberOfCores) Then
NumberOfProcessors = Trim(objItem.NumberOfCores) 'NumberOfProcessors
End If
If Not IsNull(objItem.NumberOfLogicalProcessors) Then
iCPUCoreCount = Int(Trim(objItem.NumberOfLogicalProcessors))
End If
If Not IsNull(objItem.DataWidth) Then
strHTAArchitecture=Trim(objItem.DataWidth) & "-bit"
End If
If Not IsNull(objItem.description) Then
strCPUDesc = Trim(objItem.description) 'cpu name
End If
End If
Next
If NumberOfProcessors = "" Then
NumberOfProcessors = "UNKNOWN"
End If
fGetCPUInfo = Int(NumberOfProcessors)
' iCPUCoreCount = Int(NumberOfLogicalProcessors)
End If
End Function
'====================================================
'====================================================
Function fGetComputerSystemProdIDNumber(strWQLID)
'Aim: Get UUID from Win32_ComputerSystemProduct
'Return: great big integer
Dim colSys,objSys
Dim strUUID
On Error resume next
Set colSys = GetObject("winmgmts:").ExecQuery(strWQLID,"WQL",lFlags)
If Err then
Call ErrHandler("fGetComputerSystemProdIDNumber: Error querying " & strWQLID,2)
Else
For Each objSys In colSys
If Not IsNull(objSys.IdentifyingNumber) Then
strUUID = Trim(objSys.IdentifyingNumber)
End If
Next
If strUUID = "" Then
fGetComputerSystemProdIDNumber = "UNKNOWN"
Else
fGetComputerSystemProdIDNumber = strUUID
End If
End If
End Function
'=================================================================================
'=================================================================================
Function fGetDrives(strQuery)
Dim colDisks,objHDD
Dim strDriveType, strDiskSize, strDisk
Dim strDiskFSType
Dim iGBUnits
On Error Resume Next
iGBUnits=1073741824
Dim iRAW
iRAW=0
Set colDisks = GetObject("winmgmts:").ExecQuery(strQuery)
For Each objHDD In colDisks
Select Case objHDD.DriveType
Case 1 strDriveType = "Drive could not be determined."
Case 2 strDriveType = "Removable Drive"
Case 3 strDriveType = "Local hard disk."
Case 4 strDriveType = "Network disk."
Case 5 strDriveType = "Compact disk (CD)"
Case 6 strDriveType = "RAM disk."
Case Else strDriveType = "Drive type Problem."
End Select
strDiskFSType = objHDD.FileSystem
'Find C
If objHDD.Name="C:" Then
If isNull(objHDD.FreeSpace) Then
If blnDebug=True then Call ErrHandler("ALERT!! Volume " & objHDD.Name & "is RAW",1) 'Abort/clean
fCheckDrives="ALERT!! Volume " & objHDD.Name & "is RAW"
End If
End If
strDiskSize = Int(objHDD.Size /iGBUnits) & "GB" 'calc size of disk
strDisk = strDisk & VbCrLf & "Vol " & objHDD.Name & " (" & strDriveType & ") size: " & strDiskSize & " (free: " & Int(objHDD.FreeSpace /iGBUnits) & "GB), " & strDiskFSType
fGetDrives=strDisk
Next
If (Err.Number <>0) Then
Call ErrHandler("WMI Property Query Error: [" & Err.Number & "]",2)
fGetDrives = -1
Exit Function
End If
End Function
'=================================================================================
'=================================================================================
Function fUniversalCheckData(varData,strStage) 'template
'Aim: Check value passed...
'is not blank
'is in range x..y
'spelt OK
'is in a list
'format is text, numeric
'return: string: the original value
On Error Resume Next
Dim Err
if blnDebug Then StatusBar.InnerText = StatusBar.InnerText & VbCrLf & "Validating " & strStage & " data..."
If Err Then
Call ErrHandler("WARNING: Error discovering value in " & strStage,2) '1=Quit,2=Warn
strHTAModel="Unknown"
Else
Select Case varData
Case IsEmpty(varData) Or IsNull(varData)
Call ErrHandler("WARNING: Error in "& strStage,2) '1=Quit,2=Warn
fUniversalCheckData="Unknown"
Case IsNumeric(varData)
If varData<0 Then
Call ErrHandler("WARNING: Value negative"& strStage,2) '1=Quit,2=Warn
fUniversalCheckData="Unknown"
End if
' & varData &
Case IsDate(varData)
Case Else
fUniversalCheckData=varData 'Data OK - return value unchanged
End Select
End If
End Function
'=================================================================================
'Checks - follow if true DO, if false warn/abort
'=================================================================================
Function fCheckBattery(strQuery)
'Aim: Find if battery is running
'Return pass/fail
On Error Resume Next 'equiv to Err.Clear
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Dim colItems, item
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\WMI")
Set colItems = objWMIService.ExecQuery("SELECT * FROM BatteryStatus Where Voltage > 0", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each item In colItems
if objItem.PowerOnline = True Then
strHTABattery=objItem.PowerOnline
strHTABatteryState = cFail
Err.Raise 9010,"fCheckBattery",strHTABattery & " Laptop running on battery. OSD Cannot continue."
Call ErrHandler(ucase(strHTABatteryState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1)
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "FATAL ERROR - Laptop on Battery. Please plug into an outlet before proceeding."
iTimer = window.setTimeout("Abort", iAbortTimeout, "VBScript")
Else
strHTABatteryState = cPassed
End if
Next
fCheckBattery=strHTABattery
End Function
'====================================================
Function fCheckProcess(strQuery)
'Aim: Find if outlook is running
'Return pass/fail
On Error Resume Next 'equiv to Err.Clear
Dim colItems, item
Set colItems = GetObject("winmgmts:").ExecQuery(strQuery,"WQL",lFlags)
For Each item In colItems
if item.Name = "OUTLOOK.EXE" Then
strHTAOutlook=item.Name
strHTAOutlookState = cFail
Err.Raise 9010,"fCheckOutlook",strHTAOutlook & " running. OSD Cannot continue."
Call ErrHandler(ucase(strHTAOutlookState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1)
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "FATAL ERROR - Outlook Running, please close outlook before proceeding."
iTimer = window.setTimeout("Abort", iAbortTimeout, "VBScript")
Elseif item.Name = "communicator.exe" Then
strHTAOutlook=item.Name
strHTAOutlookState = cFail
Err.Raise 9010,"fCheckOutlook",strHTAOutlook & " running. OSD Cannot continue."
Call ErrHandler(ucase(strHTAOutlookState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1)
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "FATAL ERROR - Communicator Running, please close OCS before proceeding."
iTimer = window.setTimeout("Abort", iAbortTimeout, "VBScript")
Else
strHTAOutlookState = cPassed
End if
Next
fCheckProcess=strHTAOutlook
End Function
'====================================================
'1 - Make
Function fCheckVendor(strVendor)
'Aim: Check make is one the OS/build is designed For
'Return: STRINGS for "Make", BIOS version and BIOS date (generic): strHTAVendorState pass or fail
On Error Resume Next
Dim colItems,objItem
Set colItems = GetObject("winmgmts:").ExecQuery(strVendor, "WQL", lFlags)
For Each objItem In colItems
strHTAVendor=objItem.Manufacturer
if objApprovedMakesDict.exists(strHTAVendor) then
strBIOSver=objItem.SMBIOSBIOSVersion
strBIOSDate=Mid( objItem.ReleaseDate, 5, 2 ) & "/" & Mid( objItem.ReleaseDate, 7, 2 ) & "/" & Left( objItem.ReleaseDate, 4 )
strHTAVendorState=cPassed
Else
strHTAVendorState=cFail
Err.Raise 9010,"fCheckVendor",strHTAVendor & " found. The build will not work on this make of hardware"
Call ErrHandler(ucase(strHTAVendorState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1)
bAbortBuild=True
end if
Next
fCheckVendor=strHTAVendor
End Function
'=================================================================================
'=================================================================================
'2 - Models check
Function fCheckModel(strThisModel)
'Aim Check target machine is in list of models
'Return string
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking model..." & VbCrLf
If objModelsDict.exists(trim(strThisModel)) then ' if current model in objDict then huzzah
strHTAModelState=cPassed
StatusBar.InnerText=StatusBar.InnerText & vbTab & "Model detected: " & vbTab & strHTAModelState
Else
strHTAModelState=cFail
Err.Raise 9010,"fCheckModel",strThisModel & " found. The build will not work on this model of hardware"
Call ErrHandler(ucase(strHTAModelState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1)
end if
fCheckModel=strHTAModel
End Function
'=================================================================================
'=================================================================================
'3 - RAM
Function fCheckRAM(strRAM)
'Aim: Check installed RAM > x
'Return string digits with units, e.g. 4GB
'use strHTARAM for value
'==================================================================
' Memory Preflight Check (from MDT2012)
'==================================================================
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking RAM..."
If Err.Number <> 0 Then
Call ErrHandler("Error occurred while calculating computer's memory.",2)
End If
fCheckRAM = Int(strRAM/1024) & "GB" 'format in GB
If Int(strRAM) > cMinimumMemoryMB Then
strHTARAMState=cPassed 'Sufficient memory - show whole number in GB"
StatusBar.InnerText=StatusBar.InnerText & vbTab & "RAM installed: " & vbTab & strHTARAMState
Else
strHTARAMState=cFail
Err.Raise 9030 ,"fCheckRAM","Not enough memory in this machine!" & " Required physical memory is: " & cMinimumMemoryMB & " MB."
Call ErrHandler(ucase(strHTARAMState) & ": " & Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1) 'abort build
End If
End Function
'=================================================================================
'=================================================================================
'4 - NTFS disk
Function fCheckNTFS(strDiskFS)
'Aim: Check HDD is NTFS
'Return string
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking file system is not RAW..."
If Instr(1,strDiskFS,cMinFS,VBTextCompare)<>0 Then
fCheckNTFS=cMinFS 'disk format is OK (NTFS)
StatusBar.InnerText=StatusBar.InnerText & vbTab & " File system: " & cPassed
Else
fCheckNTFS=cFail
Err.Raise 9040 ,"fCheckNTFS","WARNING: Disk not correct file-system. Type required is: " & cMinFS & "." & VbCrLf & _
"The deployment will fail unless you reformat the target disk immediately."
Call ErrHandler(Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",2) 'halt build
End If
End Function
'====================================================
'=================================================================================
'5 - CPU checks
'=================================================================================
Function fCheckCPUSpeed(strCPU) 'any HW
'Aim: Check CPU speed
'Return string = number + appropriate units, e.g. 5HGz (strCPU)
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking CPU spec..."
Select Case Right(strCPU,3) 'check units
Case "MHz"
strCPU=Left(strCPU,4)/1000 'reformat to GHz
Case "GHz"
strCPU=strCPU 'unit already OK
Case Else
Call ErrHandler("CPU units are unknown",2)
End Select
'Check clock speed
If Int(Left(trim(strCPU),1))>=iMinCPUSpeed Then
fCheckCPUSpeed=strHTACPUSpeed 'CPU is fine i.e don't change value
StatusBar.InnerText=StatusBar.InnerText & vbTab & "CPU Speed: " & cPassed
Else
fCheckCPUSpeed=cFail 'already in GHz
Err.Raise 9050,"fCheckCPUSpeed","CPU speed pre-requisite failed. Minimum processor clock speed is: " & iMinCPUSpeed
Call ErrHandler(Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1) 'halt build
End If
End Function
'=================================================================================
'=================================================================================
Function fCheckCPUArch(strCPUArch) 'any HW
'Aim: Check CPU width
'Return string
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking CPU bus width..."
'Check clock speed
If Int(Left(trim(strCPUArch),2))>=iMinCPUArch Then
fCheckCPUArch=strHTAArchitecture 'CPU is fine i.e don't change value
StatusBar.InnerText=StatusBar.InnerText & vbTab & "CPU width: " & cPassed
Else
fCheckCPUArch=cFail 'already in GHz
Err.Raise 9052,"fCheckCPUArch","CPU width pre-requisite failed. Minimum processor width required is: " & iMinCPUArch
Call ErrHandler(Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",1) 'abort build
End If
End Function
'=================================================================================
Function fCheckCores(iCores)
'Aim: Check hardware (CPU) has a minimum number of cores
'Return Integer
On Error Resume Next
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & "Checking CPU cores..."
If iCores>=iMinCores Then
fCheckCores=iCores
StatusBar.InnerText=StatusBar.InnerText & vbTab & "Core count: " & vbTab & cPassed
'StatusBar.InnerText=StatusBar.InnerText & vbTab & "CPU cores: " & cPassed
Else
fCheckCores=cFail
Err.Raise 9051,"fCheckCores","WARNING: Not enough cores on the CPU to support the build. Minimum CPU cores is: " & iMinCores
Call ErrHandler(Err.Description & " (Code: " & Err.Number & " - " & Err.Source & ")",2) 'halt build
End If
End Function
'=================================================================================
'=================================================================================
Function fCheckHPCPUSpeed 'HP ONLY
'Aim: Check CPU speed
'return: string
'Check CPU speed
On Error Resume Next
strWQLCPU = "processor speed"
strTemp=QueryHPBIOS(strWQLCPU,"")
Select Case Right(strTemp,3)
Case "MHz"
strTemp=Left(strTemp,4)/1000 'reformat to GHz
Case "GHz"
strTemp 'is OK
Case Else
Call ErrHandler("CPU is unknown",2)
End Select
'Check clock speed
If strTemp>=iMinCPUSpeed Then
fCheckCPUSpeed= strTemp & "GHz"
Else
Err.Raise 9050,,"CPU speed pre-requisite failed"
Call ErrHandler("CPU is too slow",1)
fCheckCPUSpeed=cFail 'already in GHz
End If
End Function
'=================================================================================
'=================================================================================
Function fGetModels
'Aim: Read external text file
'return: dictionary object - models as key, integer as value e.g. Dell Optiplex,12
'On Error Resume Next
Dim objFSO
Dim objFile
Dim strFile
Dim strEntry
Dim n
Dim strfilepath
Dim iLineCount 'count lines to avoid listing first item with ,.
Set objModelsDict = CreateObject("Scripting.Dictionary")
set objFSO=CreateObject("Scripting.FileSystemObject")
Const ForReading=1
strfilepath = Left(window.location.pathname,InStrRev(window.location.pathname,"\"))
strFile=strfilepath & "Models.txt"
set objFile=objFSO.OpenTextFile(strFile,ForReading)
iLineCount=0
'read in each line of data until you reach the end of the file
do While objFile.AtEndOfStream<>True
strEntry=objFile.ReadLine
'you can now do what ever you want with the line as referenced with the strEntry variable such as
'echoing it back (e.g. wscript.Echo strEntry) or passing it as a variable to a function of subroutine (e.g. MyFunction strEntry)
objModelsDict.comparemode=VBTextCompare
objModelsDict.Add strEntry,iLineCount
iLineCount=iLineCount+1
If blnDebug then
If iLineCount=1 Then
StatusBar.InnerText=trim(strEntry)
Else
StatusBar.InnerText=StatusBar.InnerText & ", " & trim(strEntry) 'list models
End If
End If
Loop
objFile.Close
End Function
'=================================================================================
'=================================================================================
'====================================================
Function ErrHandler(strErrorMsg,iErrMode)
'Aim: to handle error states
' 1 = Abort
' 2 = Warn
'Return 'Appropriate text message explaining the error
'====================================================
Const msgTitle="SCCM Deployment Preflight Checklist"
'On Error Resume Next '< don't use that as we want to KEEP the error properties
'Abort=1
If iErrMode=1 Then
StatusBar.InnerText=strErrorMsg 'overwrite status with Error message
' StatusBar.InnerText=StatusBar.InnerText & VbCrLf & " " & strHTAOutlook & " " & strHTAVendor & " " & strHTAVendorState & _
' VbCrLf & " " & strHTAModel & strHTAModelState & _
' VbCrLf & " " & strHTARAM & strHTARAMState & _
' VbCrLf & " " & strHTAHDD & strHTAHDDState
iTimer = window.setTimeout("Abort", iAbortTimeout, "VBScript") 'Abort (close) after n seconds
'MsgBox strErrorMsg,vbExclamation,msgTitle
'ErrBar.class=""
ElseIf iErrMode=2 Then
'Warning
StatusBar.InnerText=StatusBar.InnerText & VbCrLf & strErrorMsg & " " '& "(" & Err.Description & " :" & Err.Number & ")"',vbExclamation,msgTitle
Err.Clear
End If
End Function
'====================================================
Sub Abort
'Aim: Quit gracefully
window.close()
End Sub
</script>
<!-- #region BODY -->
<body>
<br />
<div>
<span style="version"> <span id="VersionSpan"></span></div>
<div style="text-align: center;">
<H1 style="font-family: Arial, Helvetica, sans-serif; font-size: large; text-align: center; color: #000000; text-transform: capitalize">System information</H1>
<span>
<table border="1" cellspacing="0" cellpadding="0" style="width: 912px"
id="SysInfoTable">
<tr class="h1">
<td align="right" class="Header1" style="width: 76px; height: 18px">
</td>
<td align="right" class="Header1" style="height: 18px"><em id="VendorCaption">Vendor</em></td>
<td align="left" class="style2" style="height: 18px"><span id="Vendor"></span></td>
<td align="right" class="Header2" style="height: 18px"><em id="ModelCaption">Model</em></td>
<td align="center" class="style4" style="width: 400px; height: 18px"><span id="Model"></span></td>
</tr>
<tr>
<td align="right" class="Header1" style="width: 76px">
</td>
<td align="right" class="Header1"><em id="ProductCaption">Product ID</em></td>
<td align="left" class="style2"><span id="Product"></span></td>
<td align="right" class="Header2"><em id="RAMCaption">Memory(in MB)</em></td>
<td align="left" class="style4" style="width: 400px"><span id="RAM"></span></td>
</tr>`
<tr>
<td align="right" class="Header1" style="width: 76px">
</td>
<td align="right" class="Header1"><em id="CPUCaption">CPU speed (in GHz)</em></td>
<td align="left" class="style2"><span id="CPUspeed"></span></td>
<td align="right" class="Header2"><em id="CPUInfoCaption">No: CPU\Cores</em></td>
<td align="left" class="style4" style="width: 400px"><span id="CPUInfo"></span></td>
</tr>
<tr>
<td align="right" class="Header1" style="width: 76px">
</td>
<td align="right" class="Header1"><em id="DiskFSCaption">Filesystem info</em></td>
<td align="left" class="style2"><span id="HDDFS"></span></td>
<td align="right" class="Header2"><em id="CapableArchCaption">Architecture</em></td>
<td align="left" class="style4" style="width: 400px"><span id="CapableArchitecture"></span></td>
</tr>
<tr>
<td align="right" class="Header1" style="width: 76px">
</td>
<td align="right" class="Header1"><em id="BIOSVerCaption">BIOS version</em></td>
<td align="left" class="style2" ><span id="BIOSVERSION"></span></td>
<td align="right" class="Header2"><em id="BIOSDateCaption">BIOS Date</em></td>
<td align="left" class="style4" style="width: 400px"><span id="BIOSDate"></span></td>
</tr>
</table>
</span>
</div>
<div class="StatusBar">
<br />
<Span id="StatusBar">Loading...please wait.</Span>
</div> <br><br>
<div align="center">
<input type="button" name="btnStop" id="btnStop" value="Continue" onclick="Abort">
<input type="Button" value="Re-Scan Machine" name="button1" onClick="Window_Onload" class="button">
</div>
</body><!-- #endregion -->
</html> -
Java ME 8 Permission check failed when opening a serial port
I have a larger Jave ME8.1 application that was going well until I tried to add one last piece, reading and writing data from a serial port. This was left to last because it is trivial, at least in most programming languages. The is IDE NetBeans 8.0.2 running on a Windows 7 PC. The platform is a Raspberry Pi B or B+ (I have tried both) with the most current Raspbian (12/24/2014 I believe). To simplify the process I created a new app with just the open and close code and this generates the same error I am experiencing in the larger application. The program is as follows:
package javamecomapp;
import java.io.IOException;
import java.io.InputStream;
import java.io.OutputStream;
import java.util.logging.Level;
import java.util.logging.Logger;
import javax.microedition.io.CommConnection;
import javax.microedition.io.Connector;
import javax.microedition.midlet.MIDlet;
* @author ****
public class JavaMEcomApp extends MIDlet {
static int BAUD_RATE = 38400;
static String SERIAL_DEVICE = "ttyAMA0";
static CommConnection commConnection = null;
static OutputStream os = null;
static InputStream is = null;
static String connectorString;
private int rtnValue = -1;
@Override
public void startApp() {
java.lang.System.out.println("Opening comm port.");
try {
rtnValue = JavaMEcomApp.openComm();
} catch (IOException ex) {
Logger.getLogger(JavaMEcomApp.class.getName()).log(Level.SEVERE, null, ex);
@Override
public void destroyApp(boolean unconditional) {
java.lang.System.out.println("Closing comm port.");
try {
rtnValue = JavaMEcomApp.closeComm();
} catch (IOException ex) {
Logger.getLogger(JavaMEcomApp.class.getName()).log(Level.SEVERE, null, ex);
private static int openComm()throws IOException {
java.lang.System.out.println("Opening comm port.");
connectorString = "comm:" + SERIAL_DEVICE + ";baudrate=" + BAUD_RATE;
commConnection = (CommConnection)Connector.open(connectorString);
is = commConnection.openInputStream();
os = commConnection.openOutputStream();
return 0;
private static int closeComm()throws IOException {
java.lang.System.out.println("Closing comm port.");
is.close();
os.close();
commConnection.close();
return 0;
If I comment out the JavaMEcomApp.openComm and closeComm lines it runs fine. When they are included, the following error is dumped to the Raspberry Pi terminal:
Opening comm port.
Opening comm port.
[CRITICAL] [SECURITY] iso=2:Permission check failed: javax.microedition.io.CommProtocolPermission "comm:ttyAMA0;baudrate=38400" ""
TRACE: <at java.security.AccessControlException: >, startApp threw an Exception
java.security.AccessControlException:
- com/oracle/meep/security/AccessControllerInternal.checkPermission(), bci=118
- java/security/AccessController.checkPermission(), bci=1
- com/sun/midp/io/j2me/comm/Protocol.checkForPermission(), bci=16
- com/sun/midp/io/j2me/comm/Protocol.openPrim(), bci=31
- javax/microedition/io/Connector.open(), bci=77
- javax/microedition/io/Connector.open(), bci=6
- javax/microedition/io/Connector.open(), bci=3
- javamecomapp/JavaMEcomApp.openComm(), bci=46
- javamecomapp/JavaMEcomApp.startApp(), bci=9
- javax/microedition/midlet/MIDletTunnelImpl.callStartApp(), bci=1
- com/sun/midp/midlet/MIDletPeer.startApp(), bci=5
- com/sun/midp/midlet/MIDletStateHandler.startSuite(), bci=246
- com/sun/midp/main/AbstractMIDletSuiteLoader.startSuite(), bci=38
- com/sun/midp/main/CldcMIDletSuiteLoader.startSuite(), bci=5
- com/sun/midp/main/AbstractMIDletSuiteLoader.runMIDletSuite(), bci=130
- com/sun/midp/main/AppIsolateMIDletSuiteLoader.main(), bci=26
java.security.AccessControlException:
- com/oracle/meep/security/AccessControllerInternal.checkPermission(), bci=118
- java/security/AccessController.checkPermission(), bci=1
- com/sun/midp/io/j2me/comm/Protocol.checkForPermission(), bci=16
- com/sun/midp/io/j2me/comm/Protocol.openPrim(), bci=31
- javax/microedition/io/Connector.open(), bci=77
- javax/microedition/io/Connector.open(), bci=6
- javax/microedition/io/Connector.open(), bci=3
- javamecomapp/JavaMEcomApp.openComm(), bci=46
- javamecomapp/JavaMEcomApp.startApp(), bci=9
- javax/microedition/midlet/MIDletTunnelImpl.callStartApp(), bci=1
- com/sun/midp/midlet/MIDletPeer.startApp(), bci=5
- com/sun/midp/midlet/MIDletStateHandler.startSuite(), bci=246
- com/sun/midp/main/AbstractMIDletSuiteLoader.startSuite(), bci=38
- com/sun/midp/main/CldcMIDletSuiteLoader.startSuite(), bci=5
- com/sun/midp/main/AbstractMIDletSuiteLoader.runMIDletSuite(), bci=130
- com/sun/midp/main/AppIsolateMIDletSuiteLoader.main(), bci=26
Closing comm port.
Closing comm port.
TRACE: <at java.lang.NullPointerException>, destroyApp threw an Exception
java.lang.NullPointerException
- javamecomapp/JavaMEcomApp.closeComm(), bci=11
- javamecomapp/JavaMEcomApp.destroyApp(), bci=9
- javax/microedition/midlet/MIDletTunnelImpl.callDestroyApp(), bci=2
- com/sun/midp/midlet/MIDletPeer.destroyApp(), bci=6
- com/sun/midp/midlet/MIDletStateHandler.startSuite(), bci=376
- com/sun/midp/main/AbstractMIDletSuiteLoader.startSuite(), bci=38
- com/sun/midp/main/CldcMIDletSuiteLoader.startSuite(), bci=5
- com/sun/midp/main/AbstractMIDletSuiteLoader.runMIDletSuite(), bci=130
- com/sun/midp/main/AppIsolateMIDletSuiteLoader.main(), bci=26
java.lang.NullPointerException
- javamecomapp/JavaMEcomApp.closeComm(), bci=11
- javamecomapp/JavaMEcomApp.destroyApp(), bci=9
- javax/microedition/midlet/MIDletTunnelImpl.callDestroyApp(), bci=2
- com/sun/midp/midlet/MIDletPeer.destroyApp(), bci=6
- com/sun/midp/midlet/MIDletStateHandler.startSuite(), bci=376
- com/sun/midp/main/AbstractMIDletSuiteLoader.startSuite(), bci=38
- com/sun/midp/main/CldcMIDletSuiteLoader.startSuite(), bci=5
- com/sun/midp/main/AbstractMIDletSuiteLoader.runMIDletSuite(), bci=130
com/sun/midp/main/AppIsolateMIDletSuiteLoader.main(), bci=26
I have tried this with three different serial ports, /dev/ttyAMA0 (yes I did disable the OS from using it), an arduino board /dev/ttyACM0, and a USB to RS485 adaptor /dev/ttyUSB0. All of these ports could be connected and use normally with both a C program and terminal program in the Pi. The API Permissions were set in the project properties / Application Descriptor / API Permissions to jdk.dio.DeviceMgmtPermission "/dev/ttyAMA0". This of course was changed as I tested different devices.
I found a reference suggesting adding the line "authentication.provider = com.oracle.meep.security.NullAuthenticationProvider" to the end of the jwc_properties.ini file. This had no effect. I found references that during development in eclipse and NetBeans, the app is already elevated to the top level so this should not be an issue until deployment. This does not appear to be the case.
I am out of time and need a solution quickly. Any suggestions are welcome.Terrence,
Thank you for responding and confirming the issues I'm having with static addressing. As far as the example above, I do have the standard LEDs working correctly, however, the example I'm referring to above is from the JavaME samples using the GPIO Port for the LEDS, according to the Device I/O Preconfigured List you referenced:
GPIO Ports
The following GPIO ports are preconfigured.
Devicel ID
Device Name
Mapped
Configuration
8
LEDS
PTB22
PTE26
PTB21
direction = 1 (Output only)
initValue = 0
GPIOPins:
controllerNumber = 1
pinNumber = 22
mode = 4 (Push-pull mode)
controllerNumber = 4
pinNumber = 26
mode = 4 (Push-pull mode)
controllerNumber = 1
pinNumber = 21
mode = 4 (Push-pull mode)
So is the assumption that using GPIOPort for accessing the GPIO port for Device ID 8 as listed in the Device I/O Preconfigured list not supported? -
Post install checks failed for DBC file - Oracle App11.5.10.2 Linux 5.3
Hi everybody,
I tried Installing Oracle E-Business Suite 11.5.10.2 on Red Hat Enterprise Linux Server release 5.3
The Post install checks failed for DBC file, HTTP, JSP and PHP. Apparently the DBC hadn’t been created. I had verified the log file, while executing adgendbc.sh, it throwing below error.
Generating /jith/d01/oracle/appl/visappl/fnd/11.5.0/secure/prithvi.bangalore.bedford.local_vis.dbc
DBC generation failed with exit code 127
Generating /jith/d01/oracle/appl/visappl/fnd/11.5.0/secure/prithvi_vis.dbc
DBC generation failed with exit code 127
Updating Server Security Authentication
Updating Server Security Authentication failed with exit code 127
adgendbc.sh exiting with status 127
ERRORCODE = 127 ERRORCODE_END
.end std out.
touch: error while loading shared libraries: librt.so.1: cannot open shared object file: No such file or directory
sqlplus: error while loading shared libraries: libdl.so.2: cannot open shared object file: No such file or directory
mkdir: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
grep: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
sed: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
/jith/d01/oracle/appl/viscomn/util/java/1.4/j2sdk1.4.2_04/bin/java: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory
cp: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
/jith/d01/oracle/appl/viscomn/util/java/1.4/j2sdk1.4.2_04/bin/java: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory
cp: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
/jith/d01/oracle/appl/viscomn/util/java/1.4/j2sdk1.4.2_04/bin/java: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory
cp: error while loading shared libraries: libc.so.6: cannot open shared object file: No such file or directory
/jith/d01/oracle/appl/viscomn/util/java/1.4/j2sdk1.4.2_04/bin/java: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory
/jith/d01/oracle/appl/viscomn/util/java/1.4/j2sdk1.4.2_04/bin/java: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory
.end err out.
Thanks in advance.
sreejithWelcome to the forums !
Pl post EBS related question in the EBS forums at http://forums.oracle.com/forums/category.jspa?categoryID=3
HTH
Srini -
System architecture check failed while adding a New Node in RAC
Hi Friends,
Environment:SUN Solris 10
Cluster Version:10.2.0.3
database Version:10.2.0.3.0
Due to H/W failure one of our RAC node(prod1) got formatted.
We have deleted the node(prod1) from RAC successfully.
But When i am again trying to add the node and checking prerequistes i am facing the below issue.
$ cd /software/oracle/product/crs/bin
$ ./cluvfy stage -pre crsinst -n prod1,prod2
Check: System architecture
Node Name Available Required Comment
prod2 unknown 64-bit failed
prod1 64-bit 64-bit passed
Result: System architecture check failed.But issue is that prod2 is my active(running node), so how to resolve this issue?
please suggest..
Regards
UmeshResolved..
Thanks... -
Exchange 2013 SP1 readiness check failing
Trying to install our first Exchange 2013 SP1 server on Windows 2012 R2 in our datacentre, the readiness check fails with:
Error:
The Active Directory schema isn't up-to-date, and this user account isn't a member of the 'Schema Admins' and/or 'Enterprise Admins' groups.
For more information, visit: http://technet.microsoft.com/library(EXCHG.150)/ms.exch.setupreadiness.SchemaUpdateRequired.aspx
There are many more errors relating to Enterprise admin rights etc.
Please note that:
My account is Domain admin, Schema admin and Enterprise admin member, it always has been.
I tried the built-in AD Administrator which of course is part of the groups as well, no difference.
Active Directory is at 2008 R2 for domain and forest functional levels.
I tried rejoining the new Exchange designated server to the domain
I've installed RSAT-ADDS, the Managed API 4.0 and all the other windows roles via powershell
There is a local domain controller that is a global catalog server on the new Exchange server subnet
I tried running the Exchange Setup on a different server on the same subnet as where the active 2010 Exchange server resides as well as the FSMO AD role holder resides, this works fine. I even did the AD prep from there no problem, that made no difference
on the datacentre server
AD replicates fine between the FSMO role holder and the Datacentre (no errors in dcdiag or repadmin /showrepl)
This error is in the event log:
The description for Event ID 4027 from source MSExchange ADAccess cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.
If the event originated on another computer, the display information had to be saved with the event.
The following information was included with the event:
ExSetupUI.exe
6724
Get Servers for domain.local
TopologyClientTcpEndpoint (localhost)
3
System.ServiceModel.EndpointNotFoundException: Could not connect to net.tcp://localhost:890/Microsoft.Exchange.Directory.TopologyService. The connection attempt lasted for a time span of 00:00:02.0475315. TCP error code 10061: No connection could be made because the target machine actively refused it 127.0.0.1:890. ---> System.Net.Sockets.SocketException: No connection could be made because the target machine actively refused it 127.0.0.1:890
at System.Net.Sockets.Socket.DoConnect(EndPoint endPointSnapshot, SocketAddress socketAddress)
at System.Net.Sockets.Socket.Connect(EndPoint remoteEP)
at System.ServiceModel.Channels.SocketConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
--- End of inner exception stack trace ---
Server stack trace:
at System.ServiceModel.Channels.SocketConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
at System.ServiceModel.Channels.BufferedConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
at System.ServiceModel.Channels.ConnectionPoolHelper.EstablishConnection(TimeSpan timeout)
at System.ServiceModel.Channels.ClientFramingDuplexSessionChannel.OnOpen(TimeSpan timeout)
at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
at System.ServiceModel.Channels.ServiceChannel.OnOpen(TimeSpan timeout)
at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
Exception rethrown at [0]:
at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
at System.ServiceModel.ICommunicationObject.Open()
at Microsoft.Exchange.Net.ServiceProxyPool`1.GetClient(Boolean useCache)
at Microsoft.Exchange.Net.ServiceProxyPool`1.TryCallServiceWithRetry(Action`1 action, String debugMessage, WCFConnectionStateTuple proxyToUse, Int32 numberOfRetries, Boolean doNotReturnProxyOnSuccess, Exception& exception)
the message resource is present but the message is not found in the string/message tableSo I decided to re-install the OS, worked perfectly now. Only difference from before would be:
SCCM hasn't pushed SCEP 2012 to the new build of the same server yet
The original server was installed in a different AD site and then it was physically mode and reassigned to an new AD site and subnet
I might have installed the pre-reqs in a slightly different order (RSAT-ADDS, all the IIS etc things via powershell
and then the UCM API 4.0. (saw few comments that the order of how you install them matters in other forums).
10 or so Microsoft Windows updates haven't installed on the new OS build yet.
Other than that, its identical. But if its not broken don't fix it, perhaps the above can help someone else though. -
I have tried everything I have found online to get my DigiCert to work.
I have exported the cert and imported it into my child domains and they look perfect.
It is just my parent domain having issues.
netsh winhttp show proxy
does show my correct proxy server for http and https and port 8080
I have tried name, FQDN and IP address.
In the Bypass-list I have tried none, *.domain.com, and a list of all domains and child domains in my forest.
I have flushed the cache
certutil -urlcache crl delete
certutil -urlcache ocsp delete
and rebooted the Exchange 2010 (Windows 2008 R2) server
No matter what, I still see in my Server Configuration for the parent domain's DigiCert cert the message
The certificate status could not be determined because the revocation check failed.
with a red X on the left hand icon. Again, Child domains all say "The certificate is valid for Exchange Server usage."
Note: In spite of having the red X, I was able to assign via EMS the services.
Webmail works fine. Outlook Anywhere fails... I suspect it is due to my red X problem.
Suggestions?
Thanks in Advance
Jim.
Jim.I have contacted DigiCert and they said the cert is working per their utility, hence the problem is outside the scope of their support.
I have followed, several times, http://support.microsoft.com/kb/979694
http://www.digicert.com/help/ reports all is well.
The DigiCertUtil.exe reports all is well and happy.
I have run
netsh winhttp set proxy proxy-server="http=myproxy:8080;https=myproxy:8080" bypass-list="*.mydomain.com"
Current WinHTTP proxy settings:
Proxy Server(s) : http=myproxy:8080;https=myproxy:8080
Bypass List : *.mydomain.com
I have flushed the cache using the commands
certutil -urlcache crl delete
certutil -urlcache ocsp delete
I still see in my Server Configuration for the parent domain's DigiCert cert the message
"The certificate status could not be determined because the revocation check failed."
with a red X on the left hand certificate icon.
To verify the cert via command line:
certutil -verify -urlfetch c:\mail_domain_com.cer
LoadCert(Cert) returned ASN1 bad tag value met. 0x8009310b (ASN: 267)
CertUtil: -verify command FAILED: 0x8009310b (ASN: 267)
CertUtil: ASN1 bad tag value met.
I suspect this is why I cannot get Outlook Anywhere to connect.
Child domains show a happy certificate icon. Parent domain does not.
Still scratching my head.
Thanks all!
Jim. -
EMC - Certificate status could not be determined because revocation check failed.
I've exhausted my resources on this issue and am reaching out for some assistance. I have setup Server 2008 R2 Enterprise SP1, running Exchange 2010 SP1. In EMC I have successfully imported a GoDaddy SSL certificate. Although I am receiving the message -
"The certificate status could not be determined because the revocation check failed."
Here are the steps I've taken to troubleshoot this so far:
[PS] C:\Users\Administrator\Desktop>netsh winhttp show proxy
Current WinHTTP proxy settings:
Direct access (no proxy server).
As you can see, direct access. Which is true, no proxy's on this network.
For good measure, I'll dump the urlcache.
certutil -urlcache ocsp delete
certutil -urlcache crl delete
Both return 0, reboot server.
Comes back up, same message in EMC.
From PS, I test exactly what its getting from GoDaddy.
[PS] C:\Users\Administrator\Desktop>certutil -f -urlfetch -verify mail.fluxlabs.net.crt
Issuer:
SERIALNUMBER=07969287
CN=Go Daddy Secure Certification Authority
OU=http://certificates.godaddy.com/repository
O=GoDaddy.com, Inc.
L=Scottsdale
S=Arizona
C=US
Subject:
CN=mail.fluxlabs.net
OU=Domain Control Validated
O=mail.fluxlabs.net
Cert Serial Number: 27b60918638e0d
dwFlags = CA_VERIFY_FLAGS_ALLOW_UNTRUSTED_ROOT (0x1)
dwFlags = CA_VERIFY_FLAGS_IGNORE_OFFLINE (0x2)
dwFlags = CA_VERIFY_FLAGS_FULL_CHAIN_REVOCATION (0x8)
dwFlags = CA_VERIFY_FLAGS_CONSOLE_TRACE (0x20000000)
dwFlags = CA_VERIFY_FLAGS_DUMP_CHAIN (0x40000000)
ChainFlags = CERT_CHAIN_REVOCATION_CHECK_CHAIN (0x20000000)
HCCE_LOCAL_MACHINE
CERT_CHAIN_POLICY_BASE
-------- CERT_CHAIN_CONTEXT --------
ChainContext.dwInfoStatus = CERT_TRUST_HAS_PREFERRED_ISSUER (0x100)
ChainContext.dwErrorStatus = CERT_TRUST_REVOCATION_STATUS_UNKNOWN (0x40)
ChainContext.dwErrorStatus = CERT_TRUST_IS_OFFLINE_REVOCATION (0x1000000)
SimpleChain.dwInfoStatus = CERT_TRUST_HAS_PREFERRED_ISSUER (0x100)
SimpleChain.dwErrorStatus = CERT_TRUST_REVOCATION_STATUS_UNKNOWN (0x40)
SimpleChain.dwErrorStatus = CERT_TRUST_IS_OFFLINE_REVOCATION (0x1000000)
CertContext[0][0]: dwInfoStatus=102 dwErrorStatus=1000040
Issuer: SERIALNUMBER=07969287, CN=Go Daddy Secure Certification Authority, OU=http://certificates.godaddy.com/repository, O="GoDaddy.com, Inc.", L=S
cottsdale, S=Arizona, C=US
NotBefore: 8/20/2011 7:49 PM
NotAfter: 8/20/2012 7:16 PM
Subject: CN=mail.fluxlabs.net, OU=Domain Control Validated, O=mail.fluxlabs.net
Serial: 27b60918638e0d
SubjectAltName: DNS Name=mail.fluxlabs.net, DNS Name=www.mail.fluxlabs.net
33 49 57 5d 6e d8 6b aa b9 61 73 95 44 07 c9 2e 55 6e 47 10
Element.dwInfoStatus = CERT_TRUST_HAS_KEY_MATCH_ISSUER (0x2)
Element.dwInfoStatus = CERT_TRUST_HAS_PREFERRED_ISSUER (0x100)
Element.dwErrorStatus = CERT_TRUST_REVOCATION_STATUS_UNKNOWN (0x40)
Element.dwErrorStatus = CERT_TRUST_IS_OFFLINE_REVOCATION (0x1000000)
---------------- Certificate AIA ----------------
Verified "Certificate (0)" Time: 4
[0.0] http://certificates.godaddy.com/repository/gd_intermediate.crt
---------------- Certificate CDP ----------------
Expired "Base CRL (05)" Time: 4
[0.0] http://crl.godaddy.com/gds1-55.crl
---------------- Base CRL CDP ----------------
No URLs "None" Time: 0
---------------- Certificate OCSP ----------------
Expired "OCSP" Time: 4
[0.0] http://ocsp.godaddy.com/
CRL (null):
Issuer: CN=Go Daddy Validation Authority, OU=http://certs.godaddy.com/repository/, O="GoDaddy.com, Inc.", L=Scottsdale, S=Arizona, C=US
e5 53 19 6c 54 87 8c 62 23 1b b9 11 e1 d8 3d 3f b2 04 77 3f
Issuance[0] = 2.16.840.1.114413.1.7.23.1
Application[0] = 1.3.6.1.5.5.7.3.1 Server Authentication
Application[1] = 1.3.6.1.5.5.7.3.2 Client Authentication
CertContext[0][1]: dwInfoStatus=102 dwErrorStatus=0
Issuer: OU=Go Daddy Class 2 Certification Authority, O="The Go Daddy Group, Inc.", C=US
NotBefore: 11/15/2006 8:54 PM
NotAfter: 11/15/2026 8:54 PM
Subject: SERIALNUMBER=07969287, CN=Go Daddy Secure Certification Authority, OU=http://certificates.godaddy.com/repository, O="GoDaddy.com, Inc.", L=
Scottsdale, S=Arizona, C=US
Serial: 0301
7c 46 56 c3 06 1f 7f 4c 0d 67 b3 19 a8 55 f6 0e bc 11 fc 44
Element.dwInfoStatus = CERT_TRUST_HAS_KEY_MATCH_ISSUER (0x2)
Element.dwInfoStatus = CERT_TRUST_HAS_PREFERRED_ISSUER (0x100)
---------------- Certificate AIA ----------------
No URLs "None" Time: 0
---------------- Certificate CDP ----------------
Verified "Base CRL" Time: 4
[0.0] http://certificates.godaddy.com/repository/gdroot.crl
---------------- Base CRL CDP ----------------
No URLs "None" Time: 0
---------------- Certificate OCSP ----------------
Expired "OCSP" Time: 4
[0.0] http://ocsp.godaddy.com
CRL (null):
Issuer: OU=Go Daddy Class 2 Certification Authority, O="The Go Daddy Group, Inc.", C=US
da 1e d5 63 5c 05 58 50 4e db d2 4e e8 9d 28 9d c4 36 b3 1e
Application[0] = 1.3.6.1.5.5.7.3.1 Server Authentication
Application[1] = 1.3.6.1.5.5.7.3.2 Client Authentication
Application[2] = 1.3.6.1.5.5.7.3.4 Secure Email
Application[3] = 1.3.6.1.5.5.7.3.3 Code Signing
CertContext[0][2]: dwInfoStatus=109 dwErrorStatus=0
Issuer: OU=Go Daddy Class 2 Certification Authority, O="The Go Daddy Group, Inc.", C=US
NotBefore: 6/29/2004 12:06 PM
NotAfter: 6/29/2034 12:06 PM
Subject: OU=Go Daddy Class 2 Certification Authority, O="The Go Daddy Group, Inc.", C=US
Serial: 00
27 96 ba e6 3f 18 01 e2 77 26 1b a0 d7 77 70 02 8f 20 ee e4
Element.dwInfoStatus = CERT_TRUST_HAS_EXACT_MATCH_ISSUER (0x1)
Element.dwInfoStatus = CERT_TRUST_IS_SELF_SIGNED (0x8)
Element.dwInfoStatus = CERT_TRUST_HAS_PREFERRED_ISSUER (0x100)
---------------- Certificate AIA ----------------
No URLs "None" Time: 0
---------------- Certificate CDP ----------------
No URLs "None" Time: 0
---------------- Certificate OCSP ----------------
No URLs "None" Time: 0
Application[0] = 1.3.6.1.5.5.7.3.1 Server Authentication
Application[1] = 1.3.6.1.5.5.7.3.2 Client Authentication
Application[2] = 1.3.6.1.5.5.7.3.4 Secure Email
Application[3] = 1.3.6.1.5.5.7.3.3 Code Signing
Exclude leaf cert:
b1 04 4b 90 a1 d3 48 de 46 bd d7 50 20 e3 44 b8 3f 68 39 f7
Full chain:
68 36 4d 37 2e 96 bd d2 aa 77 3f d0 e8 78 a9 e6 68 bd 7d 71
Verified Issuance Policies:
2.16.840.1.114413.1.7.23.1
Verified Application Policies:
1.3.6.1.5.5.7.3.1 Server Authentication
1.3.6.1.5.5.7.3.2 Client Authentication
Cert is an End Entity certificate
ERROR: Verifying leaf certificate revocation status returned The revocation function was unable to check revocation because the revocation server was
offline. 0x80092013 (-2146885613)
CertUtil: The revocation function was unable to check revocation because the revocation server was offline.
CertUtil: -verify command completed successfully.
As you can see, the "revocation server is offline."
So I run the same test from another server on the LAN.
Verified Issuance Policies:
2.16.840.1.114413.1.7.23.1
Verified Application Policies:
1.3.6.1.5.5.7.3.1 Server Authentication
1.3.6.1.5.5.7.3.2 Client Authentication
Cert is an End Entity certificate
Leaf certificate revocation check passed
CertUtil: -verify command completed successfully.
It passes. The server's firewall has been disabled. DNS cache has been cleared. I have verified everything I can, and still failing to verify.[PS] C:\Users\Administrator\Desktop>Get-ExchangeCertificate |fl
AccessRules : {System.Security.AccessControl.CryptoKeyAccessRule, System.Security.AccessControl.CryptoKeyAccessRule, System.Security.Acces
trol.CryptoKeyAccessRule}
CertificateDomains : {mail.fluxlabs.net, www.mail.fluxlabs.net}
HasPrivateKey : True
IsSelfSigned : False
Issuer : SERIALNUMBER=07969287, CN=Go Daddy Secure Certification Authority, OU=http://certificates.godaddy.com/repository, O="GoDaddy
, Inc.", L=Scottsdale, S=Arizona, C=US
NotAfter : 8/20/2012 7:16:57 PM
NotBefore : 8/20/2011 7:49:30 PM
PublicKeySize : 2048
RootCAType : ThirdParty
SerialNumber : 27B60918638E0D
Services : IMAP, POP, IIS, SMTP
Status : RevocationCheckFailure
Subject : CN=mail.fluxlabs.net, OU=Domain Control Validated, O=mail.fluxlabs.net
Thumbprint : 3349575D6ED86BAAB96173954407C92E556E4710
[PS] C:\Users\Administrator\Desktop>Enable-ExchangeCertificate -Thumbprint 3349575D6ED86BAAB96173954407C92E556E4710 -Services POP,IMAP,SMTP,IIS
The command has already been executed. Yes, I have seen those sites. Neither have worked. Like I said, it is directly connected; and no proxies are set.
-- Jeremy MCSpadden Flux Labs -
Free diskspace check failed foe ecah node
Hi all
I am tring to install oracle RAC in Windows 2003 srver.I have creared 2 virtual pc.I follwed every step correctly coz the clusterware software installs upto vipca.After that i sudelny see a blue screen stating that the hardware failure .Now i am trng eith 2 virtual pcs.when i run runcluvfy.bat stage -pre crsinst -n RAC1,RAC2 -verbose
The error is
Free disk space in
Check: Free disk space in "C:\DOCUME~1\ADMINI~1.RAC\LOCALS~1\Temp" dir
Node Name Available Required Comment
RAC2 unknown 400MB (409600KB) failed
RAC1 10.79GB (11313436KB) 400MB (409600KB) passed
Result: Free disk space check failed.
System requirement failed for 'crs'.
what should i do.Thanks
Edited by: user12119634(bobs) on Dec 13, 2009 9:02 PMDefine virtual PCs. Provide full description of the technology, vendor, and version number. If this is another attempt to use unsupported technology like VMWare then you are going against what Oracle recommends and you are on your own.
Since you do not have a valid clusterware installation as indicated by the cluster verify tool this is a really good time to stop the installation and think through these two questions:
1. What is your shared storage solution? With Windows you only have a couple of possible choices none of which you have mentioned.
2. What is your cache fusion interconnect strategy?
If you don't get these right you are wasting your time.
SB ... I have no idea why you think this question is in the wrong forum. Can you explain? -
Hi all
I am tring to install oracle RAC in Windows 2003 srver.I have creared 2 virtual pc.I follwed every step correctly coz the clusterware software installs upto vipca.After that i sudelny see a blue screen stating that the hardware failure .Now i am trng eith 2 virtual pcs.when i run runcluvfy.bat stage -pre crsinst -n RAC1,RAC2 -verbose
The error is
Free disk space in
Check: Free disk space in "C:\DOCUME~1\ADMINI~1.RAC\LOCALS~1\Temp" dir
Node Name Available Required Comment
RAC2 unknown 400MB (409600KB) failed
RAC1 10.79GB (11313436KB) 400MB (409600KB) passed
Result: Free disk space check failed.
System requirement failed for 'crs'.
what should i do.ThanksHi,
Firstly is node RAC2 is reachable?
Secondly is check the C: drive space, how much space left?
Cheers
FZheng -
Hi
We have a Windows 2012 server with Exchange 2013, all is working fine except now i am getting issues with the backup.
'Exchange - The application will not be available for recovery from this backup. the consistency check failed for the component Microsoft Exchange Server'
I have checked the database all is fine, i have created a new db and move all mailbox;s over and then removed the old db, i have enabled circular logging and then disabled it, it seems no matter what i do i cannot get a full backup!
i did have to restore the server once and the backups still worked for about 4 days after that and then stopped, i have also tried to remove and re add the backup role!
i am stumped, any advice would be great!Hi
Ok, i created a test db and tried to back it up right away, it failed, i did not add any mailbox's to it either. i got quite a few events in the windows logs, as well as the same event above i got the following:
Log Name: Application
Source: MSExchangeRepl
Date: 21/01/2013 10:16:30
Event ID: 2038
Task Category: Exchange VSS Writer
Level: Warning
Keywords: Classic
User: N/A
Computer: NERDS-DC01.nerds.local
Description:
Microsoft Exchange VSS Writer backup failed. No log files were truncated. Instance 75754d0d-8dfe-4909-8beb-5a4f824254a9. Database 4843b37c-7b3c-42b2-8b57-1393615c2c15.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="MSExchangeRepl" />
<EventID Qualifiers="32772">2038</EventID>
<Level>3</Level>
<Task>2</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-01-21T10:16:30.000000000Z" />
<EventRecordID>261645</EventRecordID>
<Channel>Application</Channel>
<Computer>NERDS-DC01.nerds.local</Computer>
<Security />
</System>
<EventData>
<Data>75754d0d-8dfe-4909-8beb-5a4f824254a9</Data>
<Data>4843b37c-7b3c-42b2-8b57-1393615c2c15</Data>
</EventData>
</Event>
AND
Log Name: Application
Source: MSExchangeRepl
Date: 21/01/2013 10:16:30
Event ID: 2038
Task Category: Exchange VSS Writer
Level: Warning
Keywords: Classic
User: N/A
Computer: NERDS-DC01.nerds.local
Description:
Microsoft Exchange VSS Writer backup failed. No log files were truncated. Instance 75754d0d-8dfe-4909-8beb-5a4f824254a9. Database db5826f3-1029-4219-ad80-441a0e94537a.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="MSExchangeRepl" />
<EventID Qualifiers="32772">2038</EventID>
<Level>3</Level>
<Task>2</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-01-21T10:16:30.000000000Z" />
<EventRecordID>261646</EventRecordID>
<Channel>Application</Channel>
<Computer>NERDS-DC01.nerds.local</Computer>
<Security />
</System>
<EventData>
<Data>75754d0d-8dfe-4909-8beb-5a4f824254a9</Data>
<Data>db5826f3-1029-4219-ad80-441a0e94537a</Data>
</EventData>
</Event>
and
Log Name: Application
Source: MSExchangeRepl
Date: 21/01/2013 10:16:30
Event ID: 2034
Task Category: Exchange VSS Writer
Level: Error
Keywords: Classic
User: N/A
Computer: NERDS-DC01.nerds.local
Description:
The Microsoft Exchange Replication service VSS Writer (Instance 75754d0d-8dfe-4909-8beb-5a4f824254a9) failed with error FFFFFFFC when processing the backup completion event.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="MSExchangeRepl" />
<EventID Qualifiers="49156">2034</EventID>
<Level>2</Level>
<Task>2</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-01-21T10:16:30.000000000Z" />
<EventRecordID>261649</EventRecordID>
<Channel>Application</Channel>
<Computer>NERDS-DC01.nerds.local</Computer>
<Security />
</System>
<EventData>
<Data>75754d0d-8dfe-4909-8beb-5a4f824254a9</Data>
<Data>FFFFFFFC</Data>
</EventData>
</Event>
and
Log Name: Application
Source: SPP
Date: 21/01/2013 10:16:30
Event ID: 16389
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: NERDS-DC01.nerds.local
Description:
Writer Microsoft Exchange Writer experienced retryable error during shadow copy creation. Retrying... More info: .
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="SPP" />
<EventID Qualifiers="0">16389</EventID>
<Level>2</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-01-21T10:16:30.000000000Z" />
<EventRecordID>261650</EventRecordID>
<Channel>Application</Channel>
<Computer>NERDS-DC01.nerds.local</Computer>
<Security />
</System>
<EventData>
<Data>Microsoft Exchange Writer</Data>
<Data>
</Data>
<Data>The writer experienced a transient error. If the backup process is retried, the error may not reoccur. (0x800423F3)</Data>
<Data>
</Data>
<Binary>00000000A5120000981200000000000042BEB7C511CAC619E59C92030000000000000000</Binary>
</EventData>
</Event> -
Seagate external drive: Partition map check failed because no slices were found
I have a 3TB Seagate Expansion external backup drive connected to my Retina Macbook Pro via USB. The disk will not eject from a regular Finder window - it will only eject from Disk Utility. Backups seem to otherwise be running fine. I tried to verify/repair the disk in Disk Utility, and I got the following error: "Partition map check failed because no slices were found." I am able to verify/repair the partition without any problem, and no errors are found.
I'm concerned about relying on a backup drive that may be heading south. Here is the output from diskutil info:
diskutil info disk3
Device Identifier: disk3
Device Node: /dev/disk3
Part of Whole: disk3
Device / Media Name: Seagate Expansion Desk Media
Volume Name: Not applicable (no file system)
Mounted: Not applicable (no file system)
File System: None
Content (IOContent): GUID_partition_scheme
OS Can Be Installed: No
Media Type: Generic
Protocol: USB
SMART Status: Not Supported
Total Size: 3.0 TB (3000592977920 Bytes) (exactly 5860533160 512-Byte-Units)
Volume Free Space: Not applicable (no file system)
Device Block Size: 4096 Bytes
Read-Only Media: No
Read-Only Volume: Not applicable (no file system)
Ejectable: Yes
Whole: Yes
Internal: No
OS 9 Drivers: No
Low Level Format: Not supported@ Allan Eckert: Unfortunately, reformatting is out of the question, I have 5 years of work on this!
@ Loner T: Yes, the firmware did successfully upgrade after router reboot and a bit of troubleshoot.
Thanks for the quick replies. Keep 'em coming! -
PLEASE HELP
Hi,I am trying to do factory recovery of my HP DV6 laptop using original HP recovery disc.My laptop has Windows 7 (64Bit) OS. I am doing below steps
By pressing F10,entering BIOS mode, changed the BOOT ORDER to take from CD ROM and saved the setting with F10 option and then forced shutdown the laptop and inserted the 1st recovery disc
Restarted the laptop and it started to boot and it asked for all 3 recovery disc + Supplement driver disc. All were successfully copied and installed. Laptop was restared multple times as it was being displayed on screen. I could see there were Softwares being installed, Service setting,registry setting being applied to computer and after around 1 to 1.5 hours laptop gets shut down, so i beleive all installations have been [performed.
Now when i start my laptop, it says
Windows was not shut down properly choose an option and when i seelct either of the 4 options like Satrt normally or Start with command prompt or Start with Networking...everytime it takes me to screen giving belwow message:
SAVE LOGS DETAILS RETRY
In Details logs, i see below as the message
P2PP BURNBOOT Check failed
Possible causes:
1. Yellow-Bang occured at device manager
2. Some silent-install failure of applications
3. Found failed at PININST_BBV
4. Found failed at PININST_BBV2
5. Found memory Dump file
Suggestion:
1. Checking REGDEV_BB.log for drivers
2. Checking BBApps.log for applications
3. Checking MEMDUMP_BBV.log for memory dump file
1. After reading forums queries, I tried to set BIOS default by pressing F9 andf then pressing F10 ,saving and exit and then tried to reinstall everything but i get the same error.
2.I tried changing the system date from March 18th 2015 to March 18th 2012 and then do recovery , but still getting same error
3. I pressed F2 and did all Memory and Hard disk test and it all passed.
So Can anyone please help me whats the issue. ThanksHi there @VKD1
Welcome to the HP Support Forums! It is a great place to find the help you need, both from other users, HP experts and other support personnel.
I understand that your notebook is not starting after a system recovery, with a "Windows was not shutdown properly" error message.
See if you can run the startup repair:
How to Run a Startup Repair in Windows 7 - sevenforums.com
Malygris1
I work on behalf of HP
Please click Accept as Solution if you feel my post solved your issue, it will help others find the solution.
Click Kudos Thumbs Up on the right to say “Thanks” for helping! -
Partition map check failed because no slices were found for WD My Book 1140 media
Have been using a WD My Book 3TB HD which was partitioned into three 1TB partitions for almost a year. Now when I try to access it via my MacBook Pro I am getting the following error message "Problems were found with the partition map which might prevent booting; Error: Partition map check failed because no slices were found". Does anybody have any suggestions on how to repair this problem and salvage information stored on it?
I am also experiencing this problem.
4TB Hitachi Deskstar. Internal. Disk not readable error on boot.
"Partition map check failed becuase no slices were found" error when I attempt to verify or repair with Disk Utility.
Maybe you are looking for
-
How to set up presentation service group based on groups defined in LDAP
Hello guys we have successfully implemented LDAP authentication, and we imported 5 groups from LDAP to BI server. However, these 5 groups and their members are not displaying on presentation server under presentation catalog group, it still only has
-
I have an ipad&iPhone but used the same iCloud account for both during setup.i now have ran out of iCloud storage! If I delete the account from iPhone will I lose the apps from my ipad? And will new account that i set up on iPhone give me 5gb storage
-
Why does a digital signature with a CA certificate not validate in adobe reader
My client has adobe reader and can not validate a digitally signed document which has a CA certificate which normally appears in the adobe root store. it comes up that one of the signatures have problems when he signs. when i email him a document t
-
Editing a Project Version (CN72 / CN41)
Hi, I have a requirement where a department build a project in CJ20N, then take a snapshot of that project using CN72 capturing the WBS structure and any Networks / Activities within the structure. They store this as an 'approved' snapshot. Later the
-
Error when calling Get-AzureBiztalkService from Windows Azure BizTalk Services Management Sample