"Memory  Sizing" error on Sun Fire V65x

Hello.
I have some trouble with my old Sun Fire V65x and i hope that you guys can help me out.
I had 2,5GB RAM installed in my server, working flawless. 2 x 256MB and 2 x 1GB modules. 256-modules in Bank 1 and 1GB´s in Bank 2.
To get rid of the boot up warning of wrong memory configuration i moved the 2 1GB modules to bank 3 (as stated in the manual) but that was when the problem started.
In this configuration the server won't go to POST, i tried moving the 1GB modules around between bank 1, 2 & 3 without any result.
The server will not go to POST. No beeps, no nothing. When turning the server on line it starts up, the fans starts running on at maximum speed and that's all, no picture and no POST and the system warning LED turns to red. After a couple of minutes in this state the fans slow down for a couple of seconds and then back to 100% (repeating cycle)
The POST diagnostics LEDs at the back of the main board indicates POST code 13h, "Memory sizing". The main board does not report any defective DIMMs, also worth mentioning is that the 2 256MB DIMMs are working flawlessly in all banks.
I have tried:
Resetting the memory config in BIOS (using the 2x256 DIMMs and then installing the 2 1GB modules.
Moving the memory modules around between different banks, both alone and with the 2 256MB DIMMs present.
Clearing the CMOS settings.
Searching manuals and Google for hours without answer to my problem or what "memory sizing " means in this situation.
System:
Sun Fire V65x
1 CPU
If anyone know the answer to my dilemma and are willing to help me, i would be really grateful.
Sadly i do not have the possibility to test the memory modules in another system.
Best regards. Erik Järlestrand, Sweden.

Hardware. A reboot will probably not do anything. From what I can tell, it's a CPU cache problem. If you do anything, shut the system down completely, turn the power off for a minimum of 20 seconds to let any residual electricty go away, the turn it back on. If the problem returns, you'll most likely need to either get a new CPU module or a new V100. I don't know if the CPU can be removed from the V100 motherboard, but since there are jumper settings for the speed I would assume that you can.

Similar Messages

  • ISO image for Sun Fire v65x diagnostics CD...

    I'm looking for an ISO image of the Sun Fire v65x diagnostics CD referred to in section 4.10 of the manual (817-2023-11.pdf). An ISO image is posted for the Sun Fire V20z / V40z. Will this work with the v65x even though it's an Intel vs. AMD system?

    Hello,
    is this what you are looking for ?
    Sun Fire(tm) V60x, V65x Diagnostic CD 4.0
    This distribution offers the Diagnostic CD image (Sun Fire(tm) V60x, V65x Diagnostic CD Release 4.0) supporting Sun Fire V60z and V65z products.
    http://www.sun.com/download/products.xml?id=441f6709
    Michael

  • ISO image for Sun Fire v60x diagnostics CD

    The only thread I can find on this diagnostic CD is from 2006:
    Re: ISO image for Sun Fire v65x diagnostics CD...
    The link posted in the forum:
    "Sun Fire(tm) V60x, V65x Diagnostic CD 4.0
    This distribution offers the Diagnostic CD image (Sun Fire(tm) V60x, V65x Diagnostic CD Release 4.0) supporting Sun Fire V60z and V65z products.
    http://www.sun.com/download/products.xml?id=441f6709" (The download link on the page does not work).
    Does not work due to the shift from Sun to Oracle.
    Can anyone point me in the right direction for the file? I've been searching for months.
    Thank you.
    Edited by: user13455836 on Mar 21, 2011 12:46 PM

    Hello,
    it should be possible to locate these files via the migrated (Sun) System Handbook.
    This is a blog entry about the new location of the System Handbook (review the 3rd comment)
    http://blogs.sun.com/patch/entry/goodbye_sunsolve_helloooo_mos
    Maybe the user Nik (http://forums.oracle.com/forums/profile.jspa?userID=826741) can help to locate the download. He is very active on these forums and an Oracle employee.
    I don't have a MOS account, otherwise I would have been able to confirm if this download is still available. I guess due to the fact that Oracle contracts are more "fine grained", it's possible that downloads only for the systems covered by your service contract are visible.
    Michael

  • Sun Fire V250 Error while booting

    Dear all,
    I have one Sun Fire V250 which was down for fews days and when I booted now it gives the following messages after booting. Is it the problem with the memory modules. It has 2 DIMM with each of 1 GB.
    Thanks in Advance
    sc>+
    sc> poweron+
    SC Alert: Host System has Reset+
    sc> con+
    Invalid command.  Type 'help' for list of commands.+
    sc> console+
    Enter #. to return to ALOM.+
    *1>Init CPU*
    +*1>     UltraSPARC[TM] IIIi, Version 2.4*+
    *1>DMMU*
    *1>DMMU TLB DATA RAM Access*
    *1>DMMU TLB TAGS Access*
    *1>IMMU Registers Access*
    *1>IMMU TLB DATA RAM Access*
    *1>IMMU TLB TAGS Access*
    *1>Init mmu regs*
    *1>Setup L2 Cache*
    *1>L2 Cache Control = 00000000.00f04400*
    *1>     Size = 00000000.00100000...*
    *1>Scrub and Setup L2 Cache*
    *1>Setup and Enable DMMU*
    *1>Setup DMMU Miss Handler*
    *1>Test and Init Temp Mailbox*
    *1>CPU Tick and Tick Compare Registers Test*
    *1>CPU Stick and Stick Compare Registers Test*
    *1>Setup Int Handlers*
    *0>Setup Int Handlers*
    *0>Send Int CPU 1*
    *1>Send Int to Master CPU*
    *0>Initialize I2C Controller*
    *0>MB:     Part-Dash-Rev#:  3753130-02-50     Serial#:  020322*
    *0>Set CPU/System Speed*
    *0>MCR Timing index = 00000000.00000002*
    *0>..*
    *0>Send MC Timing CPU 1*
    *0>Probe Dimms*
    *1>Probe Dimms*
    *1>Init Mem Controller Regs*
    *0>Init Mem Controller Regs*
    *1>Set JBUS config reg*
    *0>Set JBUS config reg*
    *0>IO-Bridge unit 0 init test*
    *0>IO-Bridge unit 1 init test*
    *0>Do PLL reset*
    *0>Setting timing to 8:1 10:1, system frequency 160 MHz, CPU frequency 1280 MHz*
    *0>Soft Power-on RST thru SW*
    *0>CPUs present in system: 0 1*
    +*0>*+
    *0>Resume selftest...*
    *0>Init SB*
    *0>Init CPU*
    *0>Init mmu regs*
    *0>Setup L2 Cache*
    *0>L2 Cache Control = 00000000.00f04400*
    *0>     Size = 00000000.00100000...*
    *0>Setup and Enable DMMU*
    *0>Setup DMMU Miss Handler*
    *0>Timing is 8:1 10:1, sys 159 MHz, CPU 1279 MHz, mem 127 MHz.*
    +*0>     UltraSPARC[TM] IIIi, Version 2.4*+
    *1>Init CPU*
    +*1>     UltraSPARC[TM] IIIi, Version 2.4*+
    *1>Init mmu regs*
    *1>Setup L2 Cache*
    *1>L2 Cache Control = 00000000.00f04400*
    *1>     Size = 00000000.00100000...*
    *1>Setup and Enable DMMU*
    *1>Setup DMMU Miss Handler*
    *1>Timing is 8:1 10:1, sys 159 MHz, CPU 1279 MHz, mem 127 MHz.*
    *0>Initialize I2C Controller*
    *1>Init Mem Controller Sequence*
    *0>Init Mem Controller Sequence*
    *0>IO-Bridge unit 0 init test*
    *0>IO-Bridge unit 1 init test*
    *0>Select Bank Config*
    *0>Probe and Setup Memory*
    *0>INFO:     1024MB Bank 0, Dimm Type X4*
    *0>INFO:     1024MB Bank 1, Dimm Type X4*
    *0>INFO:     No memory detected in Bank 2*
    *0>INFO:     No memory detected in Bank 3*
    +*0>*+
    *0>Data Bitwalk on Master*
    *0>     Test Bank 0.*
    +*0>*+
    *0>ERROR: TEST = Data Bitwalk on Master*
    *0>H/W under test = CPU0: Bank0 DIMM0, Motherboard*
    *0>Repair Instructions: Replace items in order listed by 'H/W under test' above*
    *0>MSG = Pin 79 failed on CPU0: Bank0 DIMM0, Motherboard*
    *0>END_ERROR*
    *0>     Test Bank 1.*
    +*0>*+
    *0>ERROR: TEST = Data Bitwalk on Master*
    *0>H/W under test = CPU0: Bank1 DIMM0, Motherboard*
    *0>Repair Instructions: Replace items in order listed by 'H/W under test' above*
    *0>MSG = Pin 79 failed on CPU0: Bank1 DIMM0, Motherboard*
    *0>END_ERROR*
    +*0>*+
    *0>ERROR: TEST = Data Bitwalk on Master*
    *0>H/W under test = CPU, Memory, Motherboard*
    *0>Repair Instructions: Replace items in order listed by 'H/W under test' above*
    *0>MSG =*
    *      *** Test Failed!! ****
    *0>END_ERROR*
    +*0>*+
    *0>ERROR: TEST = Data Bitwalk on Master*
    *0>H/W under test = CPU, Memory, Motherboard*
    *0>Repair Instructions: Replace items in order listed by 'H/W under test' above*
    *0>MSG = No good memory available on master CPU 0, rolling over to new Master.*
    *0>END_ERROR*
    *1>Soft Power-on RST thru SW*
    *1>CPUs present in system: 0 1*
    *1>OBP->POST Call with %o0=00000000.05002000.*
    *1>Diag level set to MIN.*
    *1>MFG scrpt mode set to NONE*
    *1>I/O port set to TTYA.*
    +*1>*+
    *1>Start selftest...*
    *1>Init SB*
    *1>Init CPU*
    *1>DMMU*
    *1>DMMU TLB DATA RAM Access*
    *1>DMMU TLB TAGS Access*
    *1>IMMU Registers Access*
    *1>IMMU TLB DATA RAM Access*
    *1>IMMU TLB TAGS Access*
    *1>Init mmu regs*
    *1>Setup L2 Cache*
    *1>L2 Cache Control = 00000000.00f04400*
    *1>     Size = 00000000.00100000...*
    *1>Scrub and Setup L2 Cache*
    *1>Setup and Enable DMMU*
    *1>Setup DMMU Miss Handler*
    *1>Test and Init Temp Mailbox*
    *1>CPU Tick and Tick Compare Registers Test*
    *1>CPU Stick and Stick Compare Registers Test*
    *1>Set Timing*
    +*1>     UltraSPARC[TM] IIIi, Version 2.4*+
    *0>Init CPU*
    +*0>     UltraSPARC[TM] IIIi, Version 2.4*+
    *0>DMMU*
    *0>DMMU TLB DATA RAM Access*
    *0>DMMU TLB TAGS Access*
    *0>IMMU Registers Access*
    *0>IMMU TLB DATA RAM Access*
    *0>IMMU TLB TAGS Access*
    *0>Init mmu regs*
    *0>Setup L2 Cache*
    *0>L2 Cache Control = 00000000.00f04400*
    *0>     Size = 00000000.00100000...*
    *0>Scrub and Setup L2 Cache*
    *0>Setup and Enable DMMU*
    *0>Setup DMMU Miss Handler*
    *0>Test and Init Temp Mailbox*
    *0>CPU Tick and Tick Compare Registers Test*
    *0>CPU Stick and Stick Compare Registers Test*
    *0>Setup Int Handlers*
    *1>Setup Int Handlers*
    *1>Send Int CPU 0*
    *0>Send Int to Master CPU*
    *1>Initialize I2C Controller*
    *1>MB:     Part-Dash-Rev#:  3753130-02-50     Serial#:  020322*
    *1>Set CPU/System Speed*
    *1>MCR Timing index = 00000000.00000002*
    *1>..*
    *1>Send MC Timing CPU 0*
    *1>Probe Dimms*
    *0>Probe Dimms*
    *0>Init Mem Controller Regs*
    *1>Init Mem Controller Regs*
    *0>Set JBUS config reg*
    *1>Set JBUS config reg*
    *1>IO-Bridge unit 0 init test*
    *1>IO-Bridge unit 1 init test*
    *1>Do PLL reset*
    *1>Setting timing to 8:1 10:1, system frequency 160 MHz, CPU frequency 1280 MHz*
    *1>Soft Power-on RST thru SW*
    *1>CPUs present in system: 0 1*
    +*1>*+
    *1>Resume selftest...*
    *1>Init SB*
    *1>Init CPU*
    *1>Init mmu regs*
    *1>Setup L2 Cache*
    *1>L2 Cache Control = 00000000.00f04400*
    *1>     Size = 00000000.00100000...*
    *1>Setup and Enable DMMU*
    *1>Setup DMMU Miss Handler*
    *1>Timing is 8:1 10:1, sys 159 MHz, CPU 1279 MHz, mem 127 MHz.*
    +*1>     UltraSPARC[TM] IIIi, Version 2.4*+
    *0>Init CPU*
    +*0>     UltraSPARC[TM] IIIi, Version 2.4*+
    *0>Init mmu regs*
    *0>Setup L2 Cache*
    *0>L2 Cache Control = 00000000.00f04400*
    *0>     Size = 00000000.00100000...*
    *0>Setup and Enable DMMU*
    *0>Setup DMMU Miss Handler*
    *0>Timing is 8:1 10:1, sys 159 MHz, CPU 1279 MHz, mem 127 MHz.*
    *1>Initialize I2C Controller*
    *0>Init Mem Controller Sequence*
    *1>Init Mem Controller Sequence*
    *1>IO-Bridge unit 0 init test*
    *1>IO-Bridge unit 1 init test*
    *1>Select Bank Config*
    *1>Probe and Setup Memory*
    *1>INFO: No memory on cpu 1*
    +*1>*+
    *1>ERROR: TEST = Probe and Setup Memory*
    *1>H/W under test = CPU1 Memory*
    *1>Repair Instructions: Replace items in order listed by 'H/W under test' above*
    *1>MSG = No good memory available on master CPU 1, rolling over to new Master.*
    *1>END_ERROR*
    *1>ERROR:*
    *1>     POST toplevel status has the following failures:*
    *1>          CPU0: Bank0 DIMM0, Motherboard*
    *1>          CPU0: Bank1 DIMM0, Motherboard*
    *1>END_ERROR*
    +*1>*+
    *1>ERROR:     No good CPUs OR CPUs with good memory left.  Calling debug menu.*
    *1>     0     Peek/Poke interface*
    *1>     1     Dump CPU Regs*
    *1>     2     Dump Mem Controller Regs*
    *1>     3     Dump Valid DMMU entries*
    *1>     4     Dump IMMU entries*
    *1>     5     Dump Mailbox*
    *1>     6     Dump IO-Bridge regs unit 0*
    *1>     7     Dump IO-Bridge regs unit 1*
    *1>     8     Allow other CPUs to print*
    *1>     9     Do soft reset*
    *1>     ?     Help*

    I have just experienced this issue while patching Solaris 10 on a V240 system using Live Upgrade.
    The issue was resolved by performing a failsafe boot from the console ("boot -F failsafe"), splitting the (new/alt) root mirror, mounting the primary half, performing fsck several times (as filesystem issues were apparrent), then mounting the slice and installing the new bootblock using the version of installboot from the new root and rebuilding the boot archive manually:
    # mount /dev/dsk/c1t0d0s4 /a
    #  /a/usr/sbin/installboot /a/usr/platform/`uname -i`/lib/fs/ufs/bootblk /dev/rdsk/c1t0d0s4
    # bootadm update-archive -R /aI note that the OpenSolaris bug linked to above lists four criteria for reproducing this problem:
    1. Install u6 ( SUNWCreq ( no mkisofs so we build ufs boot archive )
    2. Limit /tmp to 512M ( so forcing the ufs build to happen in /var/run
    3. Have seperate /var ( bootadm.c only lofs nosub mounts / when creating the alt root for DAP patching build of boot archive )
    4. Install 139555-08
    The system I was patching met the last three of these, but not the first one (pkginfo does not show SUNWCreq as being installed). However, this was not an OpenSolaris system, which may make a difference.
    Rob

  • About Sun Fire E25K I2c read time out error

    Hi,
    Can anybody give me a breif explaination about the following errors
    which capatured by Sun Fire E25K System Controller:
    Nov 7 08:16:36 2006 E25K-ORADR-sc0 hwad[11914]: [1123
    20621355893934396 ERR I2cComm.cc 410] I2c read time out - bus: 10,
    address: 21
    Nov 7 08:16:36 2006 E25K-ORADR-sc0 hwad[11914]: [1128
    20621356152372741 ERR SelectPll.cc 292] Reading bus failed in address
    0, ecode=1123
    Nov 7 18:45:40 2006 E25K-ORADR-sc0 hwad[11914]: [1123
    20659099583593289 ERR I2cComm.cc 410] I2c read time out - bus: 10,
    address: 21
    Nov 7 18:45:40 2006 E25K-ORADR-sc0 hwad[11914]: [1128
    20659099584735868 ERR SelectPll.cc 138] Reading bus failed in address
    0, ecode=1123
    Nov 8 02:15:01 2006 E25K-ORADR-sc0 hwad[11914]: [1124
    20686060070434628 ERR I2cComm.cc 1095] I2c write time out - bus: 10,
    address: 21
    Nov 8 02:15:01 2006 E25K-ORADR-sc0 hwad[11914]: [1129
    20686060083304777 ERR SelectPll.cc 181] Writing bus failed in address
    0, ecode=1124
    What is the reason to cause "I2c read time out" ?
    TIA.
    Rgds,
    Simon

    Hello Simon,
    these forums are user-to-user. The Fire E25K is definetely beyond the scope of these forums (too expensive, too critical for your business, too complex).
    This system should be under Spectrum coverage (Platinum/Gold).
    Open a service case !
    Let's if you get any response to your posting on the Sun Managers mailing list.
    Michael
    Message was edited by:
    MAALATFT

  • Sun Fire T2000 boot from RAID

    hi,
    Sun Fire T2000, firmware 6.1.12
    LSI 1064E firmware 1.0.40
    hardware RAID for internal disks
    sometimes server boots with trap, if :
    it boots from raid and you tring to break and boot from cdrom:
    {0} ok boot cdrom
    Boot device: /pci@7c0/pci@0/pci@1/pci@0/ide@8/cdrom@0,0:f File and args:
    Loading ufs-file-system package 1.4 04 Aug 1995 13:02:54.
    FCode UFS Reader 1.12 00/07/17 15:48:16.
    Redirected to slice: 1
    Loading: /platform/SUNW,Sun-Fire-T200/ufsboot
    Loading: /platform/sun4u/ufsboot
    ERROR: /pci@780/pci@0/pci@9/scsi@0: Last Trap: Fast Instruction Access MMU Miss
    [Exception handlers interrupted, please file a bug]
    [type 'resume' to attempt a normal recovery]
    {0} ok boot cdrom
    SC Alert: Host System has Reset
    SC Alert: Host system has shut down.

    Worked for me .
    ( T2000 trying to boot from the net )
    {0} ok boot net -s
    Boot device: /pci@780/pci@0/pci@1/network@0 File and args: -s
    100 Mbps full duplex Link up
    Requesting Internet Address for 0:3:ba:d9:39:2c
    Requesting Internet Address for 0:3:ba:d9:39:2c
    ERROR: /pci@780/pci@0/pci@9/scsi@0: Last Trap: Fast Instruction Access MMU Miss
    [Exception handlers interrupted, please file a bug]
    [type 'resume' to attempt a normal recovery]
    {0} ok printenv auto-boot? false
    {0} ok reset-all
    SC Alert: Host System has Reset
    SC Alert: Host system has shut down.
    Sun Fire T200, No Keyboard
    Copyright 2006 Sun Microsystems, Inc. All rights reserved.
    OpenBoot 4.20.4, 32760 MB memory available, Serial #64567596.
    Ethernet address 0:3:ba:d9:39:2c, Host ID: 83d9392c.
    {0} ok boot net -s
    Boot device: /pci@780/pci@0/pci@1/network@0 File and args: -s
    100 Mbps full duplex Link up
    Requesting Internet Address for 0:3:ba:d9:39:2c
    Requesting Internet Address for 0:3:ba:d9:39:2c
    100 Mbps full duplex Link up
    SunOS Release 5.10 Version Generic_118822-25 64-bit
    Then came up ok .
    Thanks

  • On Sun fire v490 - Solaris 10 with Oracle 8.1.7.4 & Sybase 12.0

    Hi,
    We are going to upgrade our server with this configuration -
    Sun Fire V490     2 x 1.05 GHz UltraSPARC IV CPU
    8096MB RAM     2 x73GB local disk
    2x FC 2GB Sun/QLogic HBAs
    DAT72
    On one machine we will have Sun Solaris v10 with
    Oracle DB v8.1.7.4 & Second one will be Sun Solaris v10 with Sybase DB v12.0.0.6.
    Now our question is - Sun fire have Hyper-thread CPUs ��� will the O/S and databases (Oracle and Sybase) view the proposed system as a true 4 CPU platform? Will parameters used to tune the database such as Sybase max online engines still operate in the same manner as before?
    Our old machine configuration was - Sun E450     4x400MHz CPU     1024MB RAM     2 x18; 8x36GB disks

    Questions on Oracle and Sybase should be directed to a database forum, this forum is for Sun hardware support.
    Here is a link to a DB forum I look at from time to time:
    http://www.dbforums.com/index.php
    The topic of tuning Oracle or Solaris is way beyond the scope of this forum, I have attempted to go into it before but didn't get any feedback and I would only like to spend lots of time on it if I was being paid!!! On the memory side, keep in mind that Oracle 9i 64-bit can address a maximum of 2 ^ 64 ( 16777216 TB ) memory, prior to that the DBA had to define memory parameters in init.ora. To be honest the last time I worked with a Oracle 8 database I shut a HP K class server down permanently that had been migrated to Oracle 9i on Solaris by an Oracle consultant and I can't remember all the tuning trick etc.

  • Up-gradation of Sun Fire 6800 to Sun Fire E6900 UltraSPARC IV+ Processors

    We wanted to upgrade our exisiting two Sun Fire 6800 Servers to Sun FIre E6900 with Ultra SPARC IV+ processors boards and memory only. This, we want to do through Sun UAP uniboard promotion.
    So we want to know the compatibility and additional requirement before going a head for this activity ....
    Tech specs details mentioned below ....
    Existing Sun FIre 6800 Servers Specs ...
    Processor : sparcv9 UltraSPARC-III+
    Model : Sun Fire 6800
    Processor Speed : 900 MHz
    RAM : 48 GB
    Processor Count : 24
    Will be upgraded to Sun FIre E6900 ........
    Upgrade to E6900, 12 x 1.8Ghz US IV+ CPU, 96GB Memory.
    I want to confirm below queries before placing order with Sun Micro sysytems...
    1) Is there requirement for Box change ( Chassis ) or Sun Microsystems will provide it free of cost with this promotional programme ?
    2) Is there any need to add more Power supply due to this up-gradation or additional PS will be a part of this kit ?
    3) Is there anything left out in our discussion or planning which needs to be added or upgraded to make the solution compatible ?
    Please add your valuable inputs for this up-gradation . Quick response will be highly appreciated.
    Thanks in advance ...
    Rajeev Kumar
    email : [email protected]

    Considering the domain name in your email address...
    This is far from the first SF6800 your company administers, that's been upgraded.
    Having said that, you need to keep in mind that these forums are NOT a venue for techsupport from Sun. They are hosted so that the user community can have general conversations, swap stories, and more.
    So, as for your questions:
    (1) Contact Sun and ask them for an accurate answer ( and no, the outer chassis does not get swapped ).
    (2) Contact Sun and ask them for an accurate answer ( I seem to remember that you must buy whatever PSU's, system controllers, and whatever else may be necessary, in addition to the uniboards ).
    (3) I suggest you discuss this plan with your peers in other EDS sites that have already done this. This promotion is not anything new. It seems to be offered every few months or so, since the E6900's first arrived in 2004.
    Expect to do a ton of firmware and OS upgrades so that the system can handle the US-IV+ architecture of the new hardware. That will need to be done before the new hardware is inserted to the chassis.

  • How Can I shutdown SUN FIRE 4800 Machine?

    Dear IT Experts,
    I maintain a SUN Server. It is SUN Fire F4800. To login , I must use HyperTerminal, serial cable , and Laptop.
    I have a plan to shutdown this machine for about 30 minutes for hardware maintenance checking.
    But, I can not shutdown it using command "power-off" at "OK" prompt.(before, I use "init 0" to "OK" prompt)
    I got this message :
    {13} ok power-off
    ERROR: do_interpret: no such symbol "power-off"
    ERROR: undefined word
    Could any body tell me what step can I do to shutdown this machine properly,please?
    Here is the machine description :
    - F4800 Server Base � Factory Rack
    - CPU / MEM BD BNDL � 2CPU @750/6GMEM
    - Red. Kit for Sun Fire 4800
    - PCI GIGABIT Ethernet 2.0 Card
    - PCI I/O Assy for F4800-6800
    - Media Tray HD2, DVD1, TP1
    - OPT INT PCI 10/100 Base NIC
    - Continental Europe PWR CRD KIT
    - 15 m Fiber Cable (multi-mode) and connector
    - JNI 64 Bit PCI adapter Non � OFC
    - Sun Fire Cabinet
    - Solaris 8 Std English - Only
    - OPT PWR Cord for ENTERPR. (INT)
    - SUN Trunking Software v 1.2.1
    - WS SB_100PGX64 128/15GB/CDROM
    - NORTHAMERICAN COUNTRY KIT
    Please help this newbie person.
    Thanks for any response
    Regards,
    Ferianto

    Dear All,
    Sorry, if I ask this question to this forum again. Yesterday, I tried to shutdown SUN Fire 4800 machine. It is the same machine which I asked to all of you before.
    At "OK" prompt, I typed *#.* in order to go to SC (System Controller) to shutdown the Machine. (As I know that "OK" prompt just shutdown the OS level)
    But, I got the Error message.. These are commands that I have typed, but still did not work
    {12} ok ~#
    ERROR: do_interpret: no such symbol "~#"
    ERROR: undefined word
    {12} ok ~.
    ERROR: do_interpret: no such symbol "~."
    ERROR: undefined word
    {12} ok #.
    ERROR: do_interpret: no such symbol "#."
    ERROR: undefined word
    {12} ok ~#
    ERROR: do_interpret: no such symbol "~#"
    ERROR: undefined word
    {12} ok #
    ERROR:
    I also tried to type command :(This comamand I got from SUN Firev4800 manual reference)
    OK ctrl - ]
    I connect to SUN Fire 4800 using serial cable (DB25) to USB port at my laptop, using either "Hyperterminal" or "TeraTerm"
    -Bit persecond : 9600
    -Data Bit : 8
    -Parity : None
    -Stop Bits : 1
    -Flow Control : None
    I can see the screen and typed "init 0" to go to "OK" prompt.But it still does not work. What happen? What should I do? For this case, is there any influence from "keyboard" layout (because I use my laptop keyboard) ?
    Note : I also tried typed *"init 5"* to shutdown the server, but it still go to "OK" prompt
    Please suggest...
    Thanks for any help
    Regards,
    Ferianto
    Edited by: Ferianto on Mar 10, 2008 9:05 PM

  • Installation of Solaris 8 in Sun Fire V215

    Hello.
    I'm trying to install Solaris 8 on a Sun Fire V215 which comes with Solaris 10 pre-installed. I'm doing so because some of the software we developed seems to have problems onSolaris other than version 8.
    Is Sun Fire V215 compatible with solaris 8??
    I get the following error when trying to install SOlaris 8 update 2/04 from a CD:
    Invalid install CD-ROM for karch "sun4u"
    I've been looking all over the documentation of SUn Fire V215 to see whether it was possible or not to install such an old version of Solaris, but unluckily I never found anything. Can anyone help me?
    Thank you very much
    Jorge

    That is not ever going to work.
    Solaris 8 is a discontinued product.
    That hardware will only work with SOlaris 10 and one specific release of Solaris 9.
    http://sunsolve.sun.com/handbook_pub/Systems/SunFireV215/SunFireV215.html
    If you want a more complete explanation,
    go back to your Sun sales representative, else open a support case with Sun.

  • Session problem on clustered sun fire with SP6.1

    Hi All,
    I am having a problem with a webapplication on a clustered system.
    In the following I describe the current system setup.
    I will then describe the setup of the web application.
    Following this, I explain the trouble I'm having with sharing sessions in this environment.
    Finally, I pose the key question.
    SYSTEM SETUP:
    Our group has a clustered server setup. I believe the two machines are Sun Fire systems running Solaris 9. Let me know if you need more information concerning the HW.
    To manage the cluster, we use Sun Cluster software. Let me know if you need to know the version number. I do not have it handy. We just recently setup the system (in the past 6 months).
    Also, we have the newest Sun Web Server installed 6.1. We used the default installation. The only thing we changed was the dynamicreloadinterval variable from "-1" to "60".
    WEB APPLICATION:
    We have a fairly simple MVC web application setup, which works well on a single-server system. Essentially, the web application (1) asks for a certain input via a webform, (2) takes this input, and uses it to get information from a database, (3) puts this information into a httpsession attribute, (4) redirects the response to a JSP. The JSP gets the httpsession attribute (populated in step 3) and prints it out.
    So, HTML with form posts to Servlet, Servlet gets data from database and populates a session attribute, JSP gets that session attribute and prints it out.
    Between each transition from HTML, Servlet and JSP, the currently processing server may switch. I.e. the HTML may be served, for instance, by ClusterServer1, the Servlet may be handled, for instance, by ClusterServer2, and the JSP may be served at random by either.
    THE TROUBLE I'M HAVING
    Sometimes, my JSP is able to find the session attribute and print out whatever I put into the session during the Servlet step. However, sometimes, the JSP will print out "null" (the session attribute isn't available to the JSP).
    For the HTML and the JSP, I have the page print out what server it is being served from. Thus, I can tell that the HTML is served from, for instance, ClusterServer1 while JSP is served from, for instance, ClusterServer2. Sometimes, the same server serves both.
    KEY QUESTIONS:
    Why would this be happening?
    How can I have a session stick to the user and be shared across both servers?
    What other information would you need to provide an answer concerning this issue?
    I appreciate your efforts very much!
    Matthias Edrich
    dailysun

    Hi All,
    Hi Elving,
    I read through the documentation and have the following questions:
    (1) It seems that I can share sessions amongst both servers if I
    configure the web server to store sessions in a persistant manner such as in a file or in a database. Is this correct?
    (2) To enable this persistent storage of a session, I would need to change the Session Manager used. Is this correct?
    (3) If yes, I have the choice between the following managers. Please correct me if I have misunderstood the options.
    - PersistentManager: Instead of securing session information
    in memory, this manager saves session information within
    a file on the server in a directory, which I specify within
    sun-web.xml
    - IWSSessionManager: With this manager, I can store sessions
    in a defined database or file on the server.
    - MMapSessionManager: This manager also stores sessions in
    a file on the server
    (4) What is the difference between PersistentManager and
    MMapSessionManager if my web server is running in
    single-process mode?
    (5) If MMapSessionManager is a file-based manager, where do I
    specify to what directory the related file is stored to as I
    do in PersistentManager?
    (6) What are the advantages and disadvantages of
    Persistent/IWS/MMap managers?
    (7) In looking at SessionManagers, am I even barking up
    the right tree? It seems like these would help me share
    sessions across clustered servers.
    (8) Finally, I guess my plan of action would be the following:
    -> Identify what session manager to use
    -> Include a sun-web.xml file in /WEB-INF containing
    the manager-specific info
    -> Reload my web application
    -> done...
    Is this correct?
    Elving, I appreciate your help. Thanks!
    dailysun

  • Sun Fire V490-Internal FC Drives missing in Solaris 10 installation program

    Hi,
    We have a V490 server that we are attempting to configure, but the internal FC drives are not available to the Solaris 10 installation program.
    The OpenBoot SCSI test fails:
    {3} ok test-scsi
    Testing /pci@9,600000/SUNW,qlc@2
    ERROR : ISP2200 RISC engine did not generate expected interrupt.
    DEVICE : /pci@9,600000/SUNW,qlc@2
    SUBTEST : selftest:loop-tests:inquiry-test:disk-test
    CALLERS : (f010f69c)
    MACHINE : Sun Fire V490
    SERIAL# : 66233440
    DATE : 03/27/2012 14:27:32 GMT
    CONTR0LS: diag-level=max test-args=
    /pci@9,600000/SUNW,qlc@2 selftest failed, return code = 1
    but the probe of the SCSI bus does not and displays the drives:
    {3} ok probe-scsi
    This command may hang the system if a Stop-A or halt command
    has been executed. Please type reset-all to reset the system
    before executing this command.
    Do you wish to continue? (y/n) y
    LiD HA LUN --- Port WWN --- ----- Disk description -----
    0 0 0 500000e010192d11 FUJITSU MAP3147FC 0110
    1 1 0 21000014c320ff73 SEAGATE ST314670FSUN146G055A
    How can we fix this problem?
    Thanks.
    S Kayal
    Edited by: 923748 on Mar 27, 2012 10:59 AM
    Edited by: 923748 on Mar 27, 2012 11:00 AM

    I don't think the test-scsi command is viable for that platform.
    The FC disks are "viewed" by the system as external to the SCSI controller, almost as if they were in a multi-pack.
    They are FC drives addressed by the chipset as SCSI disks.
    Try:
    <pre>probe-scsi-all</pre>
    Edit:
    Which release of Solaris 10 are you trying to install?
    Older releases that might be fine for V480's won't work on V490's.
    Edited by: rukbat on Mar 27, 2012 2:35 PM

  • Re: Sun Fire v490 / Solaris 9 booting from CD, Network problems

    Hi Folks,
    Apologies in advance for the length of this post.
    For the purposes of disaster recovery I have built a custom CD based on the Solaris 9 installation disk with our third party backup / restore software included on it.
    After the rcS script has setup networking it runs a bash shell so that I can label / partition / format the hard disks as necessary then use the third party software to recover the system.
    This works fine on almost all the machines we've tested (Ultra 10s, Ultra 30s, FS Prime Power 400)
    On one Sun Fire v490 however I seem to have problems with networking...
    Part of the customised rcS script makes the following call
    ifconfig ce0 10.4.20.20 netmask 255.255.0.0 upto configure the NIC. However when the rcS script leaves me at the shell I'm unable to ping anything.
    The output from ifconfig - a looks like...
    lo0 flag=..
        inet 127.0.0.1
    ce0: flags=1000823<UP BROADCAST,NOTRAILER,MULTICAST,IPv4>
        mtu 1500 index 2 inet 10.4.20.20 netmask ffff0000 broadcast 10.255.255.255 ether 0:14:4f:0:be:beThe only thing that looks odd to me is that there's no "RUNNING" entry for ce0 that I get if I boot from the same CD on my other machines (Ultra 30s & Ultra 10s)
    The broadcast address looks wrong, but again it's the same when I boot from th CD on my other test machines and they all seem to work.
    I'm pretty sure that ce0 is "plumbed", 'cos if I "unplumb" it from the shell prompt then it doesn't even appear in the output from ifconfig.
    Someone has suggested that it's a connectivity issue, but if I boot normally rather than from my custom CD then the networking is fine.
    As a test I tried removing the drivers for hme from the CD then booting one of my Ultra30s but in this case the entry for hme0 was completely absent from the output of ifconfig.
    So I've concluded that the driver for ce0 is at least there on the v490.
    So for the moment I'm confused as to why the ce0 appears on the output for ifconfig, but has no RUNNING 'flag'
    Anyone got any ideas
    Many thanks in advance
    Regards
    Kevin

    hello
    you have an error in your interface configuration
    you should have
    you are using a class A ip adress but with a class B netmask
    ip 10.4.20.20
    netmask 255.255.0.0
    broadcast should be 10.4.255.255
    Message was edited by:
    jerem81

  • Login problem in sun fire V490 through Hyper terminal

    I am a new user of sun Solaris 10 . In my sun fire v490 server every thing is configured fine there is no fault in booting .But when I configured the file /etc/inet/hosts in solaris 10 and missed to configure the file /etc/inet/netmask and /etc/inet/ipnodes, due to which server is not allow me to login there is an error occur " unable to login" . Now what is the other way to login into server console. I am entering in the console using normal mode, should I try to login in using diagnostic mode., or is there any other way to login into and modify the file. I also need training videos of solaris configuration .
    Help in this regard will be highly appreciable.

    I don't think the test-scsi command is viable for that platform.
    The FC disks are "viewed" by the system as external to the SCSI controller, almost as if they were in a multi-pack.
    They are FC drives addressed by the chipset as SCSI disks.
    Try:
    <pre>probe-scsi-all</pre>
    Edit:
    Which release of Solaris 10 are you trying to install?
    Older releases that might be fine for V480's won't work on V490's.
    Edited by: rukbat on Mar 27, 2012 2:35 PM

  • Sun Fire V490 dropping network connnections

    Hi
    We are having some issues on v490.
    Network connections are getting drop and users are getting given below error
    remote host : Connection reset by peer
    aocdbs02a:root# fmdump -v -u 5b137743-2acf-ceb5-bfde-f4604e3f6d4f
    TIME UUID SUNW-MSG-ID
    Nov 02 18:22:23.4500 5b137743-2acf-ceb5-bfde-f4604e3f6d4f PCIEX-8000-5Y
    50% fault.io.pci.device-invreq
    Problem in: hc://:product-id=SUNW,Sun-Fire-V490:server-id=aocdbs02a/motherboard=0/hostbridge=1/pcibus=0/pcidev=1/pcifn=0
    Affects: dev:////pci@9,600000/network@1
    FRU: hc://:product-id=SUNW,Sun-Fire-V490:server-id=aocdbs02a/motherboard=0
    Location: MB
    50% fault.io.pci.device-invreq
    Problem in: hc://:product-id=SUNW,Sun-Fire-V490:server-id=aocdbs02a/motherboard=0/hostbridge=1/pcibus=0/pcidev=2/pcifn=0
    Affects: dev:////pci@9,600000/SUNW,qlc@2
    FRU: hc://:product-id=SUNW,Sun-Fire-V490:server-id=aocdbs02a/motherboard=0
    Location: MB
    Please let me know if any patch I have to install..
    Thanks
    Sukrut s

    Lack of running for an interface normally means network connectivity issue.
    Check the network cable is plugged in securely.
    Check for light on ethernet card and switch connectivity light.
    Try a different switch port or switch and a different ethernet cable.

Maybe you are looking for

  • Requirment to add new field in kna1 and maintiane using XD02

    hi i have a requirment need suggestion on that 1) the requirmen is to add a new field email id on kna1 standard table ( it can be done by append structure pls give me full steps to do it and complication involved in it) 2) now is it possible that use

  • PSE 8 will not install on new imac OSX Snow Leopard

    28. Feb 26, 2010 4:16 PM in response to: docmark86 Re: PSE8 will not install on Mac Snow Leopard 10.6.1 I have a new iMac 21.5 screen with OSX Snow Leopard.  I installed IWork and turbo tax with no problem.  Nothing else. PSE 8 installation fails aft

  • Music on my curve

    Hey  everybody I need your help, this may be simple for some, but I'm new at this.....ok, my previous phone had a media  card with a lot of my favorite music, when I upgraded to the curve 8330 I simple moved the card to the BB and everything is fine.

  • Require a function to recognize keystroke in Dev. 6i form...!

    I need a function, which can return ASCII value of any key pressed by the keyboard directly. For example, if I pressed 'ENTER' key, the function recognize the keystroke and return me a value 13, which is the ASCII value of ENTER key. Another example

  • IDOC Adapter on receiver side- Third party non-SAP

    Hi, I have never worked on IDOC scenario.can we use idoc at receiver end to send data to receiver third party which is non SAP Plz answer quickly Regards, Sriparna