Notification set in process again at defect recording

Hi all,
In customizing, my inspection type is defined as "one Q-notification by inspection lot".  The linked notification type is A1.
I created an inspection lot.  I created a notification of type B1 with QM01 link to this inspection lot (QMEL-PRUEFLOS).  This B1 notification is already closed.
When I record an defect in QE51N for this inspection lot, a new A1 notification is created BUT the closed B1 notification is set in process again.
Is there a way to avoid this kind of behavior ?  I just want to create a new A1 notification without reopening the closed one.  Eventually just reopen existing A1 which are already closed but not other type of notifications.
Thanks in advance

Hello Sebastien,
"one Q-notification by inspection lot" applies to Inspection lot only irrespective of Notification type and it will set other notifications in-process if you record new defects.
In your case i guess both A1 and B1 are customized notification types. And in B1 notification you have incorporated "inspection lot" field by using some Exit.
When you create manual notification B1 using QM01, you enter Inspection lot number and it hits Table QMEL. Now when you record defects and create notification A1 system gets another Notification with the same inspection lot number and puts it In-Process.
Now if you consider standard notification types F2, Q2; When you go for QM01, you can not maintain Inspection lot number in Q2 notification, but for F2 (Automatically) system copies inspection lot number into notification. And as it does not get any other entry in QMEL there is no effect on Q2 notification created earlier.
Experiment on user Exit QQMA0030  Check validity of status change; and see if you can restrict putting notification in-process if Notification type is Not Same. 
Amol.

Similar Messages

  • I would like to duplicate the folders and apps that I have set up on my iPhone to my iPad.  Is there a quick way of doing this without going through the whole process again manually?

    I would like to duplicate the folders and apps that I have set up on my iPhone to my iPad.  Is there a quick way of doing this without going through the whole process again manually?

    You can restore your iPad with your iPhone backup but items that are iPhone only will not transfer.  It should recreate all your folders.  It can't hurt anything to try.

  • IN PROCESS DEFECT RECORDING

    Hi
    How to do Result Recording , Defect Recording in the Repetative manufacturing.
    In our senerio their is no Operational Coding
    Once we put the material in the production line we get the finished product only two types of codes are their 1) raw material 2) Finished Goods 
    Now i want to put a inspection point in between the Production  Process and record the Defects after the 3 operation ...
    Regards
    ramanujam

    Hi!,
    You will have to use inspection type "13" as inspection type "03" will not work in case of repetitive manufacturing. Please note that you will have to trigger the inspection lot manually by using transaction MFPR. You can inspection lot with reference to material, plant and production version combination. There you have choice in version selection. Also there won't be any inventory posting in this inspection processing. While defining the rate routing you will have to maintain QM related data. for the intended operations and that routing is to be used while defining the production version. Inspection point related data is to be entered in rate routing header. Once the inspection lot is created manually, rest of the process of result recording etc is normal. I hope this helps in resolving your problem.
    Regards,
    Uday

  • PM - Collective in process again for Notification

    hi,
    i need to in process again(recomplete) for notification. but i have a many notification and is that possible to collective in process again for all of them?

    Its not possible to do "Put in Process again" for the closed notifications in mass.
    You have to try LSMW or SAP GUI script for that.

  • Deactivate Quality Notification During Defect Recording

    Hi,
    How will I deactivate the Quality Notification Tabs during Defect Recording? Because it is showing a red traffic light which user dont want to see and mis understood that there is something wrong.
    Thank you,
    Raymond

    Hi
    What you can do is remove the creation of automatic notification in the background.
    QCC3->inspection lot creation>Maintain Inspection type->select inspec type--->remove defualt " notification type".
    This will neither create notification nor give pop-up.
    Sujit

  • Defect recording

    hello guys,
    I have a requirement that if the part got failed at the incoming inspection,some thing should trigger the quality notification before they do the UD rejection.Normally, we will click the defect icon at the RR to process quality notification manually.
    But is there any way that if somebody forgot to click the defect at RR and if they directly trying to do the UD ,it should have some control to restrict him and say to process quality notification ?
    I agree even if we forget they can manually write the quality notification thru qm01 but they dnt like that and they need some cntrol on this.
    I saw some defect recording option at MIC control indicators .....is that helps on my rqmt ?
    Pls advice
    Akash

    Hi
    I hope youi have done following cofig:
    QCC0>Quality inspection>maintain Inspection type>select 01 inspection type>Notification type:F2
    Now
    QCC0>quality planning>Basic data>Define catlog  Class>select class -->Click on Active notification.
    If you set this indicator, the quality notification (already existing) is immediately activated, when the defect data record is created. This means, that the quality notification receives the status "Outstanding notification" (OSNO).
    That means Notification will automatically remain in OSNO even if user do not create it manually.
    even if user forget to trigger it it will be geenarted & remain open.
    This will solve your problem
    Regards
    Sujit

  • The KitKat upgrade has been a disaster. home wireless is no longer recognized, even going through the set-up process.  It does not connect to the car through Bluetooth seamlessly--I have to add my phone as a new device each time I get in the car.  In atte

    My home wireless is no longer recognized, even going through the set-up process.  It does not connect to the car through Bluetooth seamlessly--I have to add my phone as a new device each time I get in the car.  In attempting to solve these problems I have gone to settings-phone-upgrade and it states that the upgrade is available-select to continue-(which I do)- it checks -please wait and it then states that update not available - try later.

    Maybe not too late to help you.
    For specifically fixing the Bluetooth, un-pair your phone with the car, and go through the process of repairing the two.
    In general, the KK update requires many of us (different phones) to perform a Factory Data Reset after we back up our personal content (pictures, music, movies, or other downloaded files) to a PC or MAC. This will result in you having to do a bit of work to setup icons for the programs you use, and maybe putting in the specifics again for email accounts and other specialized apps. So if you are going to do this sort of thing... copy important information/settings down on paper.
    HTH.

  • In setting up ICloud on my new Iphone 4s, I lost most of my calendar events in my Outlook 7 calendar.  I used to have MobileMe but in the set-up process was told to turn that off which I did but now most of my calendar events have disappeared

    In setting up ICloud on my new Iphone 4s, I lost most of my calendar events in my Outlook 7 calendar in my Vista PC.  I used to have MobileMe but in the set-up process was told to turn that off, which I did but now most of my calendar events have disappeared after syncing with ICloud.  How can I get my missing calendar events back?  They are still on my 3Gs Iphone which I have not yet updated to IOS5.
    Thanks for any help.
    marybpod

    Plug your phone into the wall charger for at least 30 minutes...make sure you have a sim card in the phone...then:
    Leave the USB cable connected to your computer, but NOT your phone, iTunes running, press & hold the home button while connecting the USB cable to your dock connector, continue holding the home button until you see “Connect to iTunes” on the screen. You may now release the home button. iTunes should now display that it has detected your phone in recovery mode, if not quit and reopen iTunes. If you still don’t see the recovery message repeat these steps again. iTunes will give you the option to restore from a backup or set up as new.
    Make sure you have no anti-virus software running or any firewalls...turn all of that stuff off.

  • Can we set "IN PROCESS" Status to more than one User

    Hi,
    As per my client current scenario every work item will be sent to 3 useru2019s (One is the supervisor of the other two users). If any one of the user executes the work item it will automatically call a Ztransaction and displays the screen. When any one of the user executes the workitem, then the workitems will dissappears from rest of the users inboxes; Setting "IN PROCESS" status for the person who executed the workitem. The workitem will be in "IN PROCESS" Status untill the User Press "SAVE" button in the transaction.
    If the person whose executed the workitem (IN PROCESS) status, has gone on unplanned leave; then the supervisor wants to forward the workitem of the current user to other user. How can he forward?
    Is there any option to set "In Process" status to more than one User? [Supervisor and Person who executed the workitem]
    Please provide me any advice to the above requirement.
    Thanks in advance,
    Ajay Kumar

    Can you ask your workflow administrator to forward the workitem to the user you want to be sent it to.
    I tried a small case wherein I had forwarded a workitem to myself and another user.
    As I executed it , it went into status IN process and at the same time it got removed from other users inbox .
    Now I went to T Code SWI1 and forwarded iut to another user say USABC.
    As a result the workitem again went into status "Ready" and into the inbox of the user ABC.
    So , you can try this in your case with the help of your workflow administrator.
    Another way is to create the other user as a substitue of the user who is currently executing the workitem.

  • Mapping with Scd operator set to type 2 reading source records two times

    Mapping with Scd operator set to type 2 reading source records two times.Records selected count being displayed at the end of execution is double the source record count.This possibly is affecting the performance of the mapping.
    Is this a bug in scd type 2 operagtor in OWB 11gR2.How to rectify this umwamted double loop through the source data selectiom?

    Hi Roelant,
    I think it is important to be aware that although Paris - 10gR2 - is not actually buggy (in this respect!), it is really quite idiosyncratic in exactly how it processes SCDs.
    I followed up on your and Mark's comments, and did an in depth analysis of this topic. It is at http://www.donnapkelly.pwp.blueyonder.co.uk/documents/OWB_10gR2_SCD.pdf
    My conclusions are perhaps of interest to anyone considering doing SCD processing with Paris.
    I'll be doing a follow-up this weekend, and publishing a sort of 'how-to-do-it' guide.
    Cheers,
    Donna
    Message was edited to add the words: "in this respect"

  • Error: Max processing time or Max records limit reached

    Hi All,
    While I run the report in Infoview, I get the below error:
    Unable to retrieve object:
    Max processing time or Max records limit reached
    Kindly suggest me.
    Thanks,
    Meena

    There is a default limit on the number of records returned and on the time out of an 'idle' connection..These could be set in the CMC , however first try to check the query for that report and see if it is applying your record selection criteria at the database level  ( use the Show Sql option and see if all your selection criteria have been turned into WHERE clauses)
    - this will drastically reduces both the number of records returned to the Crystal and the time it takes for...
    You can find setting here:
    CMC>servers>page server>properties
    Its always not recommended to set it to unlimited as page server is not a robust server, you need to schedule such reports that uses job server which is more robust.
    Regards,
    Parsa.

  • Tables for Defect type and its description while defect recording for a MIC

    Dear Experts,
    Kindly suggest the tables name  in  system by which we can get Defect type and its description that we have used while  performing defect recording for a MIC in system at the time of result reording for an inspection lot.
    Thanks in advance for your inputs ...
    Best regards ,
    Nitishj

    hii,
    Check
    QPAC - Inspection catalog codes for selected sets
    QPAM - Inspection catalog selected sets
    QPMK-CODEQUAL- Defect code grp for rejection at MIC level
    Link above table field name with QAVE for UD code & QAMR for Results recording
    Edited by: Lokesh K on Sep 29, 2010 10:43 AM
    Edited by: Lokesh K on Sep 29, 2010 10:45 AM

  • I have a PowerBook G4 17" and need Apple discs to set it up again. Mine lost during move. Screen seems damaged, has vertical lines.  Can anyone help. I can call as I have unlimited calling on my iPhone 6  anywhere in North America.

    I have a PowerBook G4 17" and need Apple discs to set it up again. Mine lost during move. Screen seems damaged, has vertical lines.  Can anyone help. I can call as I have unlimited calling on my iPhone 6  anywhere in North America.

    king,
    If your Powerbook's serial number (do not post it here) starts with "W8" then the vertical lines are mostly likely due to a defect in the display itself. W8 is a factory code and, during the iMac G5 and PowerBook G4 timespan, that factory shipped thousands of units with the same defect. It cannot be fixed via software.
    As all PowerBooks are now classed as "obsolete," an Apple Store will not work on it. They will look at it ands tell you it has vertical lines and that they cannot fix it. This Apple article shows Apple devices they curently considered obsolete:
    Vintage and obsolete products - Apple Support
    It is possible that some Apple Authorized Service Providers (AASP) will still work on older computes but they cannot get neededparts from Apple. As this issue was so pervassive, it wil be hard for you or an AASP to find a used/pulled display that is not effected with the "W8 Curse."
    Although I love the old PowerBooks, I would not even spent the money for disks, much less the US$150-400 it would cost to replace the display, even should one be available.
    If you give us a rough idea of where you are in the world, we can suggest repair shops specializing in fixing older Mac notebooks, but be aware those resources may be rather scare outside North America.

  • Max processing time or Max records limit reached (Crystal Reports Server)

    Although my report runs fine from with Crystal Reports (designer), I get an error when I try to run it from the Crystal Reports Server portal.
    I get an error u201CMax processing time or Max records limit reachedu201D.
    How can I solve this problem?
    Iu2019m accessing a DB2 database on an iSeries Server thru ODBC. I know that the report uses a lot of data. Therefore I have set u201Callow query timeout yesu201D within the ODBC data source. The data connection itself is not the problem, I have no problem running other reports on the same connection.
    PS. A do not know whether or not this is the right forum for my post. I first posted within "Java Development - BusinessObjects Enterprise, BusinessObjects Edge, Crystal Reports Server" but I did not get any response.

    I found the answer to my problem:
    1) Log onto the CMC
    2) Goto "Servers" in the dropdown menu
    3) Expand "Service Categories"
    4) Select "Crystal Reports Services
    5) In the right window will be listed the currently running services.  The 2 services that Dell mentioned are in there under "Description":  CrystalReportsProcessingServer and CrystalReports2013ProcessingServer
    Hope this helps somebody else.

  • Set up process for iphone on continuous loop

    I have an iPhone 4 and just updated to the latest operating software.
    When I plug my iPhone in it goes through the set up screen asking me to carry out the series of steps - select language country etc and then I get to the "Set up Iphone" with options to:
    - Set up as new iphone
    - Restore from ICLoud back up
    - Restore from Itunes back up
    I select the third option and then when connected to itunes select to "Restore backup". The process kicks off and ofr an instant I see all the apps on the screen I have before switching to a "Restore in Progress" screen. This continues until complete and then reboots at which time it goes to the initial set up screen again and then it starts all over again. It is getting incredibly frustrating.
    Is there anything that I am doing wrong in the set up? Am I selecting the correct option?
    Any help would be appreciated!
    Thank you
    BA

    Try setting it up as a new phone and see if it completes the setup process.
    If it does not, there is very likely a hardware issue with your phone and you need to bring it to an Apple store for evaluation.
    ~Lyssa

Maybe you are looking for