Insane Object error while saving: Can i identify case from error message?

Hi,
I get the following message "Insane Object at BDHP+36C8c in "Data Logger.vi"{graphics}(0x80):Wire Segment (WIRE). I have seen errors like this in the past. It usually happens when the wire gets coiled like a snake or gets behind a place that cannot be viewed etc. The last time i had the problem, i had to delete the wire and rewire to have the problem solved. Is there any way for me to identify the case that has this wiring problem from the error description? I get this annoying dialog everytime i save my vi. Thanks for your time in advace.
Anand.

The message means there is a problem with an object on the block diagram (the BD of BDHP). Fixes include copying the diagram to a new VI, and randomly deleting objects and replacing them. You might also try pressing control-shift-run arrow on the VI to perform a binary recompile of the VI. It is a long shot but it is quick and easy do do. Ususally you will not see anything happen but occasionally LabVIEW can highlight the error or even correct it.

Similar Messages

  • Insane object error does not resolve upon re-load

    http://digital.ni.com/public.nsf/allkb/AFA28DCC3DE89839862566B200594E8C
    does not resolve this issue.  Even when I close the VI & re-open it, I get the following error message:
    I tried doing dozens of undo edits of the last 10 or 20 changes.  None of them work.  None of the suggested fixes work at all, either.
    Worse yet, I can tell that my code is not what is looks like. It is not running the code that is on the diagram, it is running some previous version of the code.
    Solved!
    Go to Solution.
    Attachments:
    insane object error.PNG ‏12 KB

    Hi Greg,
    Thanks for your reply.  It sounds like you've been on both ends of a serious error/crash resulting in code loss before.
    As Murphy's Law would have it, it happened right before quitting time.
    I decided to stick it out & make it a late night while I remembered most of my changes.
    I quit & restarted LabVIEW, pulled the VI from a backup done the day before, opened up the backup version of the VI, opened up the bad code, and tried pasting changes in.  However, I soon got oodles of "insane object" errors, and gave up on this route.
    I quit & restarted LV, opened up the backed up VI, opened the bad new VI on a 2nd monitor (after configuring the display etc.), and manually re-drew (i.e., "re-wrote") all my code just by inspection.
    This worked. (To play it safe, I also forced a system backup before going home, and saved lots of revs. along the way during my edits.)
    I rarely have experienced "insane object" errors in my 10+ years of LabVIEW programming.  Therefore, I have used little of other languages the past 10 years, and have developed so much re-usable code that I know well, I don't want to move away from it.  It is quite unsettling / scary when it happens, especially on a large program.  It makes me consider going back to text-based programming, where at least there's some inspection of all but the most messed up files (vim/binary mode, for example).
    Anyway, I am on my way now, but will be even more diligent about "Save As" to save interim versions during long code writing sessions.
    Also, I ran chkdsk per Apps Engr suggestion on a ticket I did later open after doing this post.
    Thanks, Matt

  • Insane object error(The string control not getting any values)

    In LabVIEW 8.2 i am using the string control to get the text from the users, and initially there was no problem at the time of development it works perfectly, after building the installer,
    these string controls are not getting any string input, it seems like a disabled one, but actually it was not disabled, when we try to click over that through the mouse,
     that text inputting cursor was not blinking over there,I screen looks as below, some error messages are thrown from the LabVIEW like insane object error, even
    now there was the same problem in the source code itself, what to do rectify this. Only this part generates error all other remaining screen panels are working perfectly.

    This kind of problem can be a pain to locate. This often occurs when the wiring to or from a control or indicator is bery long, convoluted and hidden inside of structures or behind things. So first, you need to identify which VI specifically is generating the error by individually saving VIs and subVIs until you find the one that is generating the error. Now try and remember the last time that VI saved without a problem and what edits you made since then. Places where I have had this occur was when I drag-copied a control and a couple VIs into a small structure. Sometimes the wires would seem to conect up properly, but when I tried to save the VI I got this error. The solution was to disconnect all the wires associated with the VIs I had copied and rewire them.
    Also, can you post the VI that is doing it? Shouldn't need the subVIs for this...
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • How do I fix an "Insane Object" Error ?

    I am receiving an "Insane Object" error when I load one partuclar VI. Is there any way to "copy" the diagram to a new file to fix the corrupted Object ? I am using Win N/T 4.0 and LabView 6i. The module was originally designed using LabView 5.X and the Module appears to work OK after accepting the Error Messages.

    I think the most complete discussion of this situation can be found in the NI KnowledgeBase. Just go to the main ni.com site, search for "insane object" and follow the first hit.
    That KnowledgeBase entry was created with a lot of input from some of the LabVIEW developers, so it's a pretty good guide.
    Regards,
    John Lum
    National Instruments

  • The eig() instruction in my matlab script is causing an insane object error

    I have matlab script in a vi that I want to use to calculate eigenvectors and eigenvalues of a large array. I started with a small array (3x3)and it calculated them incorrectly. However when i ran the same script in Matlab the correct values are returned. On top of that when I try and save the vi after running it I get an insane object error at FPHP+DC. I tried rewriting the vi without copying and pasting etc. but it wont go away. I then simplified the vi to simple integer addition and removed the eig()instruction and error doesn't appear anymore, so it seems that the eig() instruction is causing all of this and it isn't even giving the correct answers! Where does this leave me? I can't get the e
    igenvectors using the Labview vi because the array i will using eventually is (944x944) and the labview vi gives me an error saying I have exceeded maximum iterations. This is why I am using Matlab in the first place.
    Thanking you in advance!!
    Marion

    I had a similar error message come up in the jump from LV 7.1 to LV 8.0.  It would cause a couple of hard crashes of Labview whenever I worked with one particular VI.  I found it was related to a wizard lock control that I had created in LV7.1 using the HMI Wizard options of my DSC module.  I actually had two such loops in my original program, one behaved, the other caused problems in the upgrade of the VI to LV 8.0.
    I discovered this by creating multiple copies of the VI in LV 7.1 and deleting different block diagram elements from each and seeing which opened without error in 8.0 and which caused the problem until I finally discovered the problem piece of code.  It was really a divide and conquer technique.
    I liked how LV 7.1 HMI wizard automatically created code that I could unlock and modify as I needed.  It seems that the HMI wizard was eliminated from the DSC module of LV 8.0 and 8.2. There were several other major changes in the behavior of the DSC module from 7.1 to 8.0 which I am still trying to learn.
    If you can discover which control or what piece of code (hopefully it is only one) is causing the problem, perhaps you can delete it in the older file version, upgrade the VI, then recreate it in the newer version VI.

  • Insane Object Error - Image.cpp

    Is any other LV8.2 user having problems with customizing controls?
    I have only needed to do this today since the upgrade to 8.2, and am having a hard time.  I have yet to come up with an exact method to reproduce this, but it's getting to be a big problem, as LV crashes about 60% of the time when I'm editing controls.
    Is this a known issue?  I did some digging but didn't find anything specific to my problem.  I never had this problem with 7.1 (same hardware in my PC).
    Message Edited by Day on 10-10-2006 04:04 PM
    Attachments:
    Insane Object Error - image.jpg ‏16 KB

    I had a similar error message come up in the jump from LV 7.1 to LV 8.0.  It would cause a couple of hard crashes of Labview whenever I worked with one particular VI.  I found it was related to a wizard lock control that I had created in LV7.1 using the HMI Wizard options of my DSC module.  I actually had two such loops in my original program, one behaved, the other caused problems in the upgrade of the VI to LV 8.0.
    I discovered this by creating multiple copies of the VI in LV 7.1 and deleting different block diagram elements from each and seeing which opened without error in 8.0 and which caused the problem until I finally discovered the problem piece of code.  It was really a divide and conquer technique.
    I liked how LV 7.1 HMI wizard automatically created code that I could unlock and modify as I needed.  It seems that the HMI wizard was eliminated from the DSC module of LV 8.0 and 8.2. There were several other major changes in the behavior of the DSC module from 7.1 to 8.0 which I am still trying to learn.
    If you can discover which control or what piece of code (hopefully it is only one) is causing the problem, perhaps you can delete it in the older file version, upgrade the VI, then recreate it in the newer version VI.

  • Insane Object errors

    I'm suddenly getting a lot of insane object errors on my program, I've tried everything listed in the Knowledgebase topic. They're only wire and sgnl graphical errors, but they aren't resolving themselves. When I change constants in the program, more insane objects pop up.
    It's a little bit frightening, please help.
    -Capuchin

    Hi Capuchin,
    As you probably are aware from reading through that KB, insane objects mean your VI has become corrupt and you may need to rewrite your code.
    I have some debugging tools I can use to try and debug this for you. Could you post your code please?
    I also have the email you sent to UKSupport so I can contact you directly by email if you would prefer.
    Kind regards,
    Sarah
    Applications Engineer | National Instruments | UK & Ireland

  • Insane object error causes LabVIEW 6.0.2 to quit (crash)

    When I made a small modification of the wiring diagram and try to save the vi, the insane object error comes up and trashed all the modification. If I restart LabVIEW and apply the same modification, I can usually save the vi without problem. But next time when a new modification is made, LabVIEW would crash again when I try to save the vi. I am running LabVIEW 6.0.2 under Windows 2000.

    I have seen the same error as well. It has occured during edit sessions (attempts) on very large (complicated) diagrams when my video settings were at 1600x1200. I have discovered that the errors seem to be related to the video resolution settings AND the size of the block diagram. I have a Gateway twin-cpu workstation with a 1x AGP video card with 16MB of RAM; however, the problem only occurs at high resolution settings. If I set the video to 1024x768, the errors stop occuring. For those applications that require high-res settings, I code at low resolution, close the diagram, change to high resolution, and can work on the front panel with no problems.
    PS...
    I was able to freeze the screen during one of the failures and found that all of the objects were literal
    ly extruded to the same heigth as the wires -- it was really bizarre! The computer was "locked up" so that a screen shot was not possible. I called NI tech support and was told it was a "most likely" a video card problem.

  • Expected a dict object error message

    When attempting to open a PDF file in Reader sometimes get the "Expected a dict object" error message.

    Did you ever find the answer to this problem??  I am having the same problem with
    my Acrobat 9 Pro document.  When trying to insert a page to the document (300 pages long) I get the error message "expected a dict object
    Would appreciate any tips you can give me.

  • I can't save photos from text messages and cannot access keyboard

    does anyone know why i can't save pictures from text messages received and why i am unable to access my keyboard to type out messages?

    When you press and hold on the picture...it does not give you an option to save the image?  Also for the keyboard issue...go into settings/application manager(it may also say apps/manage apps).  At the top scroll over and select all.  Scroll down and find messaging and tap on it.  If you have an option to clear data and force stop then select them(it wont delete anything).  Once done go back in the list and see if you also have anything that says keyboard or android keyboard and do the clear data/force stop on that also.

  • I can't fix my insane object error!

    Hi all,
    I'm getting the following error messages when I try to save my VI after running it:
    Insane object at FPHP+208BC in "backup.vi":{sub}(0x10): Scale (DDO)
    " " FPHP+20634 " " Waveform Chart (DDO)
    " " FPHP+20E78 " " Scale (DDO)
    " " FPHP+20CB0 " " Waveform Chart (DDO)
    I read all of the info on insane objects available on the web site, and followed the instructions to fix the problem when it first appeared last week. I deleted and recreated the last charts and scales that I made, and eventually I recreated every chart and scale. This seemed to fix the problem, as I had no more error messages...until this morning.
    I'd like to avoid having to recreate everything all over
    again if possible. It's probably best that I send the VI to someone to take a look at and try to fix. We're using an opto22 interface for our readings, if that helps at all. Hopefully someone can help me fix this problem....
    Thanks,
    Andrew Poyton
    McMaster University
    Hamilton, Ont.

    Andrew,
    I was having a very similar error this morning. It turns out that the source of my problem was the range on the y-axis on one of my waveform charts was messed up. I had it set to autoscale and had been running the program and it plotted some really huge numbers because of a calculation error in one of my formulas. In any case, it seemed to run fine despite plotting bogus information, but when I went in to make changes and then tried to save I received the error messages similar to your situation and could not save. I fixed it as follows: I simply changed the values on the upper and lower end of the y-axis to something reasonable like +10 and -10. Then I tried to save and it worked just fine.
    So you might take a good look at your waveform plots and check
    the values on all of the ranges. I hope that helps you.
    tony

  • Cannot insert duplicate key row in object Error Message

    Morning All,
    I noticed today that the DW has not been updated with some of my CI's based off my custom class.
    The event log is showing these error messages.
    An error countered while attempting to execute ETL Module:
     ETL process type: Transform
     Batch ID: 5601
     Module name: TransformPeripheralDim
     Message: ErrorNumber="2601" Message="Cannot insert duplicate key row in object 'dbo.PeripheralDim' with unique index 'UniqueIndex'." Severity="14" State="1" ProcedureName="TransformPeripheralDimProc" LineNumber="163" Task="Inserting into Dimension"
     Stack:    at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
       at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
       at System.Data.SqlClient.SqlDataReader.ConsumeMetaData()
       at System.Data.SqlClient.SqlDataReader.get_MetaData()
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method)
       at System.Data.SqlClient.SqlCommand.ExecuteReader(CommandBehavior behavior, String method)
       at System.Data.SqlClient.SqlCommand.ExecuteReader()
       at Microsoft.SystemCenter.Warehouse.Utility.SqlHelper.ExecuteReader(SqlConnection sqlCon, CommandType cmdType, String cmdText, SqlParameter[] parameters)
       at Microsoft.SystemCenter.Warehouse.Etl.StoredProcedure.Execute(IXPathNavigable config, Watermark wm, DomainUser sourceConnectionUser, DomainUser destinationConnectionUser)
       at Microsoft.SystemCenter.Warehouse.Etl.TransformModule.Execute(IXPathNavigable config, Watermark wm, DomainUser sourceConnectionUser, DomainUser destinationConnectionUser)
       at Microsoft.SystemCenter.Etl.ETLModule.OnDataItem(DataItemBase dataItem, DataItemAcknowledgementCallback acknowledgedCallback, Object acknowledgedState, DataItemProcessingCompleteCallback completionCallback, Object completionState)
    ETL Module Execution failed:
     ETL process type: Transform
     Batch ID: 5601
     Module name: TransformPeripheralDim
     Message: ErrorNumber="2601" Message="Cannot insert duplicate key row in object 'dbo.PeripheralDim' with unique index 'UniqueIndex'." Severity="14" State="1" ProcedureName="TransformPeripheralDimProc" LineNumber="163" Task="Inserting into Dimension"
     Stack:    at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
       at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
       at System.Data.SqlClient.SqlDataReader.ConsumeMetaData()
       at System.Data.SqlClient.SqlDataReader.get_MetaData()
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method)
       at System.Data.SqlClient.SqlCommand.ExecuteReader(CommandBehavior behavior, String method)
       at System.Data.SqlClient.SqlCommand.ExecuteReader()
       at Microsoft.SystemCenter.Warehouse.Utility.SqlHelper.ExecuteReader(SqlConnection sqlCon, CommandType cmdType, String cmdText, SqlParameter[] parameters)
       at Microsoft.SystemCenter.Warehouse.Etl.StoredProcedure.Execute(IXPathNavigable config, Watermark wm, DomainUser sourceConnectionUser, DomainUser destinationConnectionUser)
       at Microsoft.SystemCenter.Warehouse.Etl.TransformModule.Execute(IXPathNavigable config, Watermark wm, DomainUser sourceConnectionUser, DomainUser destinationConnectionUser)
       at Microsoft.SystemCenter.Etl.ETLModule.OnDataItem(DataItemBase dataItem, DataItemAcknowledgementCallback acknowledgedCallback, Object acknowledgedState, DataItemProcessingCompleteCallback completionCallback, Object completionState)
    It was working fine so I'm not sure what's caused it to stop or where I can start looking to see what's causing it.
    Any ideas?
    Cheers,
    SB
    My System Center Blog

    Just in case it helps, this is the MP I'm using to bring the data across to the DW.
    If I removed the MP from Service Manager, would that drop the tables in the DW and allow me to start again?
    <ManagementPack
    ContentReadable="true"
    SchemaVersion="1.1"
    OriginalSchemaVersion="1.1">
    <Manifest>
    <Identity>
     <ID>AssetManagementReports</ID>
     <Version>1.0.0.6</Version>
     </Identity>
     <Name>AssetManagementReports</Name>
    <References>
    <Reference
    Alias="AssetManagemetListsRef">
     <ID>AssetManagementLists</ID>
     <Version>1.0.1.1</Version>
     <PublicKeyToken>0a39b272096917b0</PublicKeyToken>
     </Reference>
    <Reference
    Alias="AssetManagementMP">
     <ID>AssetManagement</ID>
     <Version>1.0.0.21</Version>
     <PublicKeyToken>0a39b272096917b0</PublicKeyToken>
     </Reference>
    <Reference
    Alias="DWBase">
     <ID>Microsoft.SystemCenter.Datawarehouse.Base</ID>
     <Version>7.0.5826.0</Version>
     <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
     </Reference>
    <Reference
    Alias="System">
     <ID>System.Library</ID>
     <Version>7.0.5826.0</Version>
     <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
     </Reference>
     </References>
     </Manifest>
    <Warehouse>
    <Outriggers>
    <Outrigger
    ID="EquipmentTypeList"
    Accessibility="Public">
     <Attribute
    ID="EquipmentType"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/EquipmentType$"/>
     </Outrigger>
    <Outrigger
    ID="ManufacturerList"
    Accessibility="Public">
     <Attribute
    ID="Manufacturer"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Manufacturer$"/>
     </Outrigger>
    <Outrigger
    ID="ModelList"
    Accessibility="Public">
     <Attribute
    ID="Model"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Model$"/>
     </Outrigger>
    <Outrigger
    ID="SupplierList"
    Accessibility="Public">
     <Attribute
    ID="Supplier"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Supplier$"/>
     </Outrigger>
    <Outrigger
    ID="DirectorateList"
    Accessibility="Public">
     <Attribute
    ID="Directorate"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Directorate$"/>
     </Outrigger>
    <Outrigger
    ID="DepartmentList"
    Accessibility="Public">
     <Attribute
    ID="Department"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Department$"/>
     </Outrigger>
    <Outrigger
    ID="SectionList"
    Accessibility="Public">
     <Attribute
    ID="Section"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Section$"/>
     </Outrigger>
    <Outrigger
    ID="LocationList"
    Accessibility="Public">
     <Attribute
    ID="Location"
    PropertyPath="$Context/Property[Type='AssetManagementMP!AssetManagementBaseClass']/Location$"/>
     </Outrigger>
    <Outrigger
    ID="MobileTariffList"
    Accessibility="Public">
     <Attribute
    ID="MobileTariff"
    PropertyPath="$Context/Property[Type='AssetManagementMP!MobilePhoneNumberAsset']/MobileTariff$"/>
     </Outrigger>
     </Outriggers>
    <Dimensions>
     <Dimension
    ID="PeripheralDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!Peripheral"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="MobilePhonesDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!MobilePhones"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="MobileSIMCardAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!MobileSIMCardAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="MobilePhoneNumberAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!MobilePhoneNumberAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="RemoteAccessTokenAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!RemoteAccessTokenAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="CiscoIPTelephonyAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!CiscoIPTelephonyAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="NetworkInfrastructureAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!NetworkInfrastructureAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     <Dimension
    ID="ServerInfrastructureAssetDim"
    Accessibility="Public"
    InferredDimension="true"
    Target="AssetManagementMP!ServerInfrastructureAsset"
    HierarchySupport="IncludeDerivedClassProperties"
    Reconcile="true"/>
     </Dimensions>
    <Facts>
    <RelationshipFact
    ID="MobiletoSIMCardFact"
    Accessibility="Public"
    Domain="DWBase!Domain.ConfigurationManagement"
    TimeGrain="Daily"
    SourceType="AssetManagementMP!MobilePhones"
    SourceDimension="MobilePhonesDim">
     <Relationships
    RelationshipType="AssetManagementMP!MobiletoSIMCard"
    TargetDimension="MobileSIMCardAssetDim"/>
     </RelationshipFact>
    <RelationshipFact
    ID="MobiletoPhoneNumberFact"
    Accessibility="Public"
    Domain="DWBase!Domain.ConfigurationManagement"
    TimeGrain="Daily"
    SourceType="AssetManagementMP!MobilePhones"
    SourceDimension="MobilePhonesDim">
     <Relationships
    RelationshipType="AssetManagementMP!MobiletoPhoneNumber"
    TargetDimension="MobilePhoneNumberAssetDim"/>
     </RelationshipFact>
    <RelationshipFact
    ID="MobilePhoneNumberToSIMCardFact"
    Accessibility="Public"
    Domain="DWBase!Domain.ConfigurationManagement"
    TimeGrain="Daily"
    SourceType="AssetManagementMP!MobilePhoneNumberAsset"
    SourceDimension="MobilePhoneNumberAssetDim">
     <Relationships
    RelationshipType="AssetManagementMP!MobilePhoneNumberToSIMCard"
    TargetDimension="MobileSIMCardAssetDim"/>
     </RelationshipFact>
    <RelationshipFact
    ID="PeripheralOwnedByUserFact"
    Accessibility="Public"
    Domain="DWBase!Domain.ConfigurationManagement"
    TimeGrain="Daily"
    SourceType="AssetManagementMP!Peripheral"
    SourceDimension="PeripheralDim">
     <Relationships
    RelationshipType="System!System.ConfigItemOwnedByUser"
    TargetDimension="DWBase!UserDim"/>
     </RelationshipFact>
     </Facts>
     </Warehouse>
    <LanguagePacks>
    <LanguagePack
    ID="ENG"
    IsDefault="true">
    <DisplayStrings>
    <DisplayString
    ElementID="AssetManagementReports">
     <Name>Asset
    Management Reports</Name>
     <Description>This
    management pack adds an Asset Management dimension to the Data Warehouse and other items related to reporting.</Description>
     </DisplayString>
     </DisplayStrings>
     </LanguagePack>
    <LanguagePack
    ID="ENU"
    IsDefault="false">
    <DisplayStrings>
    <DisplayString
    ElementID="AssetManagementReports">
     <Name>Asset
    Management Reports</Name>
     <Description>This
    management pack adds an Asset Management dimension to the Data Warehouse and other items related to reporting.</Description>
     </DisplayString>
     </DisplayStrings>
     </LanguagePack>
     </LanguagePacks>
     </ManagementPack>
    My System Center Blog

  • Undefined is not an object error message

    Hi there.
      I'm just new to scripting in illustrator.  actually, i'm new to illustrator too!
    but i do have a programming background.  right now, i'm just trying to familiarize myself with scripting for illustrator files.
    i have an svg file that was created by our artist.  i've opened that file in illustrator.  i've also opened a sample javascript from adobe called "makelineargradient" and i'm trying to run this script against the svg file.
    it worked fine the first time. but on subsequent compiles / runs, i'm getting the error message "undefined is not an object"
    the line it's failing on is line 1:
    if (app.documents.length > 0)
    can someone point me in the right direction?  I'm using the extendscripts tool to open and run the javascript file.

    Be sure that you are targeting Illustrator, and not the Extendscript application (there is a dropdown menu at the top left.). I'll bet that yours is still set to Extendscript (it will default to this when opened.)
    Also, you can add the line:
    #target illustrator
    at the beginning of the code to set Illustrator as the target.

  • Updated Solution Center, get cannot create DIHPAiOFax​Manger object error message on 'Send a Fax'

    The printer is an OfficeJet J4540 All-In-One, running on Vista Home Premium x64. The orginal Solution Center faxed without any problems. I upgraded to new Solution Center and when I click on 'Send A Fax' I get this error message:   "cannot create DIHPAiOFaxManger object". My OfficeJet can and does send faxes manually, but I would like to use the Solution Center. Please, help!!!
    neptune49

    This might have been a quirk of the installation. So let's try to perform a complete and clean uninstallation and reinstallation. First if you use a USB cord, make sure to remove it. Do not plug it back in until the software directs you to. Then go through the Devices and Printers, Programs and Features and Device Manager folders and insure that all copies, files, and programs related to the printer are removed. Then as directed, restart the computer. 
    In the START menu type "%temp%" and press ENTER. Here I want you to press Ctrl+A and hit DELETE. Some of the files will not allow you to delete them, skip those files and delete the majority that allows it. 
    Then follow this link to download the full feature software and drivers for the printer: 
    http://h10025.www1.hp.com/ewfrf/wc/softwareDownloa​dIndex?softwareitem=mp-58704-2&cc=us&dlc=en&lc=en&​...
    Install that and let me know the result! 
    As an additional side note, you should also be able to use Windows Fax and Scan to fax from your PC as well. 
    Have a great day!

  • Need help with Object error message

    Hello, Forum.
    In DW CS5 I'm getting an error message, "This page contains object tags that may not work properly in the most recent versions of Internet Explorer. DreamWeaver cannot convert these object tags.". Anytime I previously encountered this message, it ended with, "To correct this problem you can covert these tags to browser safe scripts. Do you want Dreamweaver to convert these tags for you?". Why does DW now say it can't convert the tags, and what can I do?
    Thanks much.
    Cayce

    Is your code valid?
    CSS - http://jigsaw.w3.org/css-validator/
    HTML - http://validator.w3.org/
    Nancy O.
    Alt-Web Design & Publishing
    Web | Graphics | Print | Media  Specialists 
    http://alt-web.com/

Maybe you are looking for

  • Cannot edit track info in itunes

    I just downloaded iTunes v. 10.6.3.25 I connected my iPhone to my computer and let iTunes see that it's there. If I try to go in under devices to my music library that is on the phone NOT in the library on the computer and try to right click, get inf

  • Use the MBP as a display

    Two questions: 1. Is there a way to use a MBP (or even a iMac or just a PC monitor) as a display for an XBox 360 using some sort of cables and converters. 2. I have an old iMac G5 running Panther and is there a way to just use that as an additional d

  • ISE EAP SSL/TLS Tunneling Certificates

    Hi, I am working on an ISE implementation that is going to perform authentcation accross several domains using LDAP. The domains that I have in my environment are a production and pre-production/testing domains. Currently my ISE appliances are joined

  • Vendor Creation from external system

    Hi there, I have a requirement from the user: An external system is used for vendor registration. The current process is where users need to create the vendor manually in SAP as there is no integration between the systems. We can not make amendments

  • Can i transfer music i already have stored on my laptop to my ipad?

    can i transfer music i already have stored on my laptop to my ipad?