Mass change in Inspection lote, when assigning UD Code.

Dear all,
curently we are facing an issue of having to mass change inspection lotes when assigning UD code.
The senario is as follows:
using the tcode QA16 I can mass assign UD code for various inspection lotes using the option "in background". The requisition of the client is, however, to enter also a description text, for all the lotes treated. I an use the tcode QA16 and run a UD manual option, that lets me enter a long text for each inspection lote, along with assigning UD code. That is not acceptable, since there are daily hundrets of lots, we are talking about. That makes the manual option very time consuming.
Anyone had a similar issue? What I am looking for here is some exit, or other type of solution that allows me basically replicate the long text (the same for all treated lots) for various lots automatically. I was thinkig of QA16, making some necessary adjustments, but I not sure if it will serve for this purpose.
Any suggestions will be highly appreciated,
best regards,
Anna

Hi,
I think you would need to go for BDC to achieve this. Since this is required on daily basis, you should run BDC to enter the long text against the UD for each batch. This should work.
ntn

Similar Messages

  • Update inspection lot when MIC changes

    Hello Gurus,
    Is there a way to update existing inspection lot when master characterstic changes?
    Any help would be really appreciated!
    Regards,
    Owais

    Hi
    You can change the Existing Inspection plans by doing setting at Cleint level as Replace MIC
    When you cahnge MIC it will give popup of where used.You can change the task lists.
    But this changes will not automatically reflect in an inspection lot.
    for this you have to
    Go to Qa02
    Enter Inspection lot
    Click on reset
    save
    check status of lot CRTD in QA32
    now go to QA02
    enter
    click on Inspection Specification
    selct sample
    save
    check status in QA32 as REL
    Regards
    Sujit

  • Want to do mass processing for inspection lots with status SPRQ

    Hello,
    My company using early lot creation for 04 inspection type. We have thousands of inspection lots with status "UD   ICCO SPRQ PRII PRSI STUP". Now due to SPRQ status, system is not closing process orders associated with thousands of inspection lots.
    Is there any transaction where I can do mass processing of inspection lots to change the status "SPCO" from "SPRQ"?
    Thanks
    Bhavesh

    Dear Bhavesh
    You may have to modify the standard program to do so. Modify this program RQEVAI30.
    This can help you
    Regards
    gajesh

  • Change of Inspection Lot Specifications at the time of lot creation

    Hi,
    We are using In-process inspeciton.
    At the time of Production Order release an Inspection Lot is created automatically.
    We want the Lot Specification values to be changed based up on the Configuration of the Sales Order.
    Is there any User Exit or BADI  that can be used for this purpose?
    Ramakanth

    Hii,
    Lot specifcation values cannot be changed once inspection lot is created. If u know specification only after creation of inspection lot then u include unplanned inspection charcteristics. Here u can define spec after lot creation also.
    with regards,
    K.Lokesh.

  • FM to change an inspection lot

    Hi folks,
    when inspection lot is created i have no information about the batch. so SAP creates the inspection lot without the batch information and sets the state CHER. unfortunately you can't fill in results to an inspection lot with state CHER.
    Now i need some functionality to tell the inspection lot the batch it concerns before using "BAPI_INSPCHAR_SETRESULT".
    Any ideas?
    thx martin

    Hi Martin,
    Check FM CO_QM_INSPECTION_LOT_UPDATE
    Thanks
    Lakshman

  • Linkage of inspection lot when the stock is posted to new material in UD.

    Dear QM Gurus,
        My client has the following requirement.
       The stock is sometimes posted to the new material whle Usage decision(Partially or completely)
        In this case the target  material has no linkage with the inspection lot of the material for which the Usage decision is done.
       The user has to manually create the inspection lot for the target material and record the same results once again for the record purpose.
       The requirement is to establish a link between the inspection lot original material and the target material  so that the additional step of creating the manual inspection lot and result recording  can be avoided.
      Is there any standard functionality through which I can link the inspection lot/result recorded to the target material or can it be acieved through some enhance ments.
      Please help.
      Regards
      Ankush

    Hi Ankush,
    I am not aware about the standard functionality for this link. But following work around may work for you. Possibly you may have to develop the ABAP report for this linkage. Try this if works.
    1.     When you do material to material transfer in QA11 it generates a movement in background with material document generation.
    2.     Pass the inspection lot through QAMB table and fetch all material documents
    3.     Pass these material documents in MSEG table and get the material
    4.     You may put several conditions for fetching these details.
    Best Regards,
    Anand Rao

  • Update of Order Changes in Inspection Lots

    Hi all,
    Is it possible to update production order changes in an inspection lot automaticaly with inspection lot origin 04?
    I know this is possible with inspection lot origin 03, but we use 04 in our company.
    Thanks in advance,
    B.
    Edited by: Brian O'N on Jul 21, 2010 2:06 AM

    Did you ever find a solution for this?  We have a similar requirement where we need to see the change history for our batch master characteristics.

  • QM qusetion realted to limit change in Inspection lot

    Dear All,
    I have question, In the result recording screen (Transaction is QE51N,QE11,etc) there are some option that are not available, I mean they are found disable that I can't click & check the functionality of it. E.g. In RR screen Goto>Change unit to be insp.>All four function for this node are not available. Can any one make me clear why it's so this and what should I do to to use/activate it.
    I have came across this functionality because of an online query.
    In one in process inspection lot the user has rectified the pH limit was wrong and I had and extreme urgent requirement to correct it.
    I have suggested them to use unplanned MIC in place of this wrong MIC and force close the wrong one or reverse the entire process.
    With Best Regards,
    Shyamal Joshi

    Hello all mentors,
    I think i will not get any relpy for this thread hence closing it to contribute for new announcement for "Question Limit of 10"
    Regards,
    Shyamal

  • Mass Cancellation of Inspection lots

    Dear Experts,
    How to cancel  the inspection lots collectively . Is there is any standard transaction for this ?
    Regards,
    Ram

    hi
    there is no standard programme or t-code to perform collectively
    you need to go woth LSMW or wrirting BDC for cancellations of lots.
    -ashok

  • Cancel inspection lot when results already recorded

    Hi,
    I have an inspection lot created via the release of a process order, since the lot has been created the process order has been canceled and now there is a requirement to cancel the associated inspection lot also. However there are results recorded and confirmed against the inspection lot and the option in QA02 Functions ->Inspection lot -> cancel is no longer available? Any suggestions on how to cancel this inspection lot would be greatly appreciated.
    Regards,
    Gary

    Dear,
    You need to use transaction QA12. In the intial screen enter the Inspection lot number and enter. From menu bar "Usage Decision" ->Functions->Cancel Lot and then save the lot.
    Please refer this link,
    [ Cancel Inspection Lot |Re: cancel QM inspection lot]
    Regards,
    R.Brahmankar

  • User status change in inspection lot

    sir,
    when i am doing  ud in qa11 that there is compulsary a USER STAUS must be QAA Aprroval by QA manager if user staus is QCNA not approvewd by QA manager then it gives error for user status changes must be compulsary.
        so where we can change that user status of .I have a one option in qa02 is there any another options.
    Please guide me

    Dear Prakash
    If you want to manualy change the status in QA11, you can change there itself. Near to the user status there is a change where you can change the user status ( Set status button - tick and change button)
    Regards
    Gajesh

  • Inspection lot sample Qty change manual

    Dear Friends ,
    Is there any T Code or procedure to change inspeciton lot sample size in inspection lot
    like how we change the Inspection lot Qty
    Thanks & Regards
    Raj

    Hi
    You can only reset the sample Quantity using qa02>enter inspection lot>click on sample ->save>This will reset the sample(remove task list)
    Now you can change the task list an attach modified sample
    Or
    Assign manual sapme calculation in Inspection type (without inspection task list)
    This will allow you to maintain/enter the manual sample size during lot creation.
    try this

  • Generate Inspection lot operation when needed

    Hi
    We are using inspection lots to record supplier results for certain raw materials.
    We now need to include our own test results to these inspection lots.
    To accomplish this we’re thinking of using the same inspection plan with a 2nd operation.
    This will enable us to generate one inspection lot per GR while recording two types of results (i.e. Op1 = Supplier, Op2 = Own).
    The inspection lot will always have results from Supplier, but we might only internally test every 10th delivery (GR).
    Is it possible to generate the 2nd operation (i.e. Own results) when needed?
    Or any other elegant approach/process?
    Thanks

    Hi Werner
    Not is possible add more results in a inspection lot when you made the usage decision.
    For this case, you can use the inspection class 89 (Other Inspection) for manually generation inspection lot when you need to register your own results.
    For this inspection class 89 you need an inspection plan with another usage (Usage 3). In this inspection plan you can to use your own test.
    Regards.
    Henry.

  • Can we create 2 inspection lots at the time of goods receipt.

    Hi experts,
         Can we create two inspection lots at the time of goods receipt from vendor.I will assign two inspection types in material master
    suppose 01,02.Both are releated to goods receipt.For one inspection lot when we take usage decision stock should not post into usage decision.for other inspection lot stock has to be posted.Is this possible?if possible how to do configuration?

    I think I made this recommendation in a previous post concerning this but this is exactly what reference operation sets are created for.
    Create the reference operation set for the characteristics that are used for all the materials.  You create this once.
    When you create the sepcific plan for the individual materials, you include the reference operation as one of the operations, (probably the first one in your case).  You don't have to add characteristics, modify or change it.  All the characeristics and settings come from the reference operation.  If you need to make a change you edit the reference operation and make the change once.   The change is immediately seen in all newly created inspection lots.
    In a second operation of the plan, you add the characteristics specific to the material.
    You can add different workcenters to the operations if you want.  That way you can set up security on the workcenters and control who can record results against which operations.
    Aside from creating lots manually, you can't create two lots at the same time from the same GR.
    Craig

  • QM- HOW TO RELEASE INSPECTION LOT

    HI GURUS.
    I HAVE A PROBLEM,PLEASE HELP ME OUT;
    GURUS, I WANT TO KNOW THAT HOW CAN I RELEASE THE INSPECTION LOT; SO THAT I CAN TRANSFER THAT QUANTITY FROM  QA TO UNRESTRICTED USED;
    PIYUSH SINGH

    First things first.
    The inspection lot when created takes the default values from the material master setting like whether the inspection is to be triggered.
    Once the inspection lot is created and after you change the material master or info records then it will not be refected in the inspection lot.
    So important thing is to get the state of quality system when the inspection lot was created to solve the problem.
    Go the transaction code [QA02] and see the requirements in the inspection specifications tab whether the Task List/ Specification button is enabled or not. If it is enabled means characteristics are not yet assigned. Press the button. If it dosnt work by pressing, it means no corresponding task list or material characteristic as specified in the materail master - Quality management Screen - Corresponding inspection type values. Even if you make changes now it wont be reflected in the lot. So get the settings at the time of creation of the inspection lot. And create the required task list [QP01] or material specification [QS61]. If already the task list / material specification button in disabled means the characteristics are picked.
    Now goto transaction [QE51N] and specify your plant and material and generate the list of open lots
    Select your lot and record the characteristics
    Not you need to valuate and close each characteristic.
    Save the data and come out of the trasaction after all the characteristics are recorded.
    Proceed to TCODE QA11
    Take a usage decision, save the data and quit the transaction.
    Now check whether the lot status is changed or not
    Please tell me if it dosnt work

Maybe you are looking for

  • How can I copy/paste text from one page to another?

    I feel like I am taking crazy pills... is there really no way to copy a text box (or group) from one page to another while creating books in Aperture 3?  Lets say I have my entire book laid out and I want to add one paragraph at the end on one page w

  • Collect multiple type of idocs in one target message

    Hi, I want to collect several idocs (WP_PLU, WP_EAN) on one target message (FILE), group by partner. I known it's possible to to that using BPM but, because of performance reason, i can't use this option. There is another way to do it? Thanks, Carme.

  • Creating stickers using Avery labels

    I recently switched from a PC to a fabulous G5 iMac. I used to create cute stickers for my students' papers with my PC using Print Artist and Avery address labels (#8160), but cannot figure out a way to do this with my Mac. I am looking for a way to

  • Open TIF files in ACR 4.5

    I have a number of images in TIF format that I wish to open in ACR 4.5. I can see how to open JPG images but not the TIF images. How might I do this? I am using Windows XP Pro SP2, Photoshop CS3, ACR 4.5. Thanks, Tom

  • Applet serial port

    Hello All, I need to write an Applet that talks to a serial port and sends some information back to the server. Is it possible for an applet to talk to a serial port? If yes, how can I approach it? Has anyone done these before? Please give me some hi